You are on page 1of 12

Eaton’s Electrical

Services & Systems

Technical Training
Safety Training
2 EATON CORPORATION Eaton’s Electrical Services & Systems
Technical Training
Safety Training
Eaton conducts technical This training has benefited • Safety
more than 19,000 people
training and electrical and our reach is international.
• Power quality
safety training at its Power For additional information • Power system engineering
Systems Experience Center or for a quotation of price,
call 724-779-5921, or contact
• Maintenance and operation
in Warrendale, PA, and can your local Eaton distributor or of Eaton and other brands
also deliver training on site sales office. For a schedule of
open-enrollment training, visit
for you and those people the customer courses link Eaton’s Electrical Services &
of your organization who at www.eaton.com/learning. Systems has been approved
maintain and manage your as an Authorized Provider by
the International Association
electrical power distribu- for Continuing Education and
tion systems. Because our Training (IACET), 1760 Old
Meadow Road, Suite 500,
training is conducted by McLean, VA 22102.
the same engineers who
We are Authorized Provider
perform power systems, number 1000921.
power quality and arc-flash
analysis, you gain the most
up-to-date information and
learn the latest techniques.

EATON CORPORATION Eaton’s Electrical Services & Systems 3


Power Quality
Monitoring
Program overview Program content
The Power Quality Monitoring Power quality fundamentals:
program is designed for engi- disturbances, harmonics,
neers and technicians who need example waveforms, equip-
to know how to identify power ment tolerances, IEEET 519
quality problems or perform and IEC standards.
measurements of sags, swells,
voltage transients, harmonic Practice sessions
distortion and voltage flicker. • Build your own equipment IACET CEUs: 1.6
More than 50 percent of the
tolerance diagram
time in this training program Duration: 2.5 days
is dedicated to hands-on • Monitoring transients,
This training is conducted at
practice using a variety of subcycle disturbances
our Power Quality Experience
popular models of portable and flicker
Center in Warrendale, PA.
and panel-mount power • Monitoring harmonics For tuition amounts and
monitors. Students are also
for our schedule, visit the
encouraged to bring their own • Evaluating power quality
customer courses link at
analyzers to learn new uses problems using power
www.eaton.com/learning.
for them in our Power Systems monitoring data
Experience Center. Each training For additional information,
program participant receives
• Special considerations
call 724-779-5921.
a comprehensive classroom for making measurements
reference manual. in high-resistance grounded To locate your nearest Eaton
distribution systems and distributor or sales office, visit
delta-wye power transformer www.eaton.com/electrical.
circuits

4 EATON CORPORATION Eaton’s Electrical Services & Systems


Industrial Power
Systems Analysis I
Program overview Program content
Upon completion of the • Introduction to Power Systems
Industrial Power Systems Analysis: basic unit relation-
Analysis I training program, ships (voltage/current/power);
you will be able to recognize ANSI device/function numbers
the several forms of power • Three-phase power
system single-line diagrams,
fundamentals: power triangle,
calculate short-circuit current,
power factor, phasor diagrams;
and evaluate the application IACET CEUs: 3.2
the per-unit system
of power circuit breakers and
power fuses. Using classroom • Distribution equipment: trans- Duration: 4.5 days
exercises and demonstrations, formers, induction machines, This training is conducted at
this training program reviews synchronous machines our Power Quality Experience
the fundamental techniques Center in Warrendale, PA and
of power systems analysis.
• Short-circuit analysis: sources
of fault current, symmetrical at other locations. For tuition
Although this training program amounts and for our schedule,
is not intended to teach the short circuits, modeling
a power system, making visit the customer courses link
use of power systems analysis at www.eaton.com/learning.
software, the instructors will impedance diagrams
use laptop computers in the • Unbalanced fault currents: For additional information
classroom and review examples derivation of non-symmetrical and pricing for on-site training,
created with SKM Power*ToolsT phasors from their symmetri- call 724-779-5921.
for WindowsT to help explain cal components, positive/ To locate your nearest Eaton
the construction of system negative/zero sequence distributor or sales office, visit
single-line diagrams and the networks, three-phase vs. www.eaton.com/electrical.
calculation of short-circuit single-line-to-ground and
current. This training program line-to-line faults
is recommended for electrical
engineers.
• Data collection, short-circuit
calculations, protective device
ratings, device evaluations,
main-tie-main closed-transition
applications, capacitive
switching
• Course examination

EATON CORPORATION Eaton’s Electrical Services & Systems 5


Industrial Power
Systems Analysis II
Program overview
Upon completion of the
Industrial Power Systems
Analysis II program, the partic-
ipant will be able to use SKM
Power*ToolsT for WindowsT
to calculate short-circuit current
and evaluate the application
of power circuit breakers and IACET CEUs: 3.2
power fuses. This program
is a follow-up to the Industrial Duration: 4.5 days
Power Systems Analysis I This training is conducted at
training. You will learn to use our Power Quality Experience
computer software to perform Center in Warrendale, PA and
the tasks that are described and at other locations. For tuition
explained in the Industrial Power amounts and for our schedule,
Systems Analysis I training. visit the customer courses link
at www.eaton.com/learning.
For additional information
and pricing of on-site training,
call 724-779-5921.
To locate your nearest Eaton
distributor or sales office, visit
www.eaton.com/electrical.

6 EATON CORPORATION Eaton’s Electrical Services & Systems


Electrical and
Arc-Flash Safety
Program overview Program content
Each new edition of the NFPAT • Electrical hazards
Standard 70E contains revised • Preparing to work safely
recommendations for protecting
workers from the hazards of • Using live line tools and
arc flash. IEEET 1584 sets the voltage detectors
industry standard for evaluating
the hazards in a power distribu-
• Lockout/tagout
tion system and its equipment. • Temporary grounding IACET CEUs: 0.8
29CFR1910 subparts R and S
tie these standards and govern-
• Flash protection boundary Duration: 1 day
mental regulations for electrical and limits of approach
(NFPA 70E) This training can be conducted
safety together. The Electrical at your location.
and Arc-Flash Safety training • Methods for selecting
program from Eaton provides protective clothing and For additional information
electricians, technicians, personal protective equipment and pricing, call 724-779-5921.
maintenance managers, safety To locate your nearest Eaton
managers and engineers with • Practical methods for
reducing arc-flash hazard distributor or sales office, visit
the information they need to www.eaton.com/electrical.
follow the standard industry
practices of government and
industry. Programs presented
in Canada include a review
of provincial regulations. Each
training program participant Some material that appears or to which reference is made
receives a comprehensive in this training program is the intellectual property of the
classroom reference manual. National Fire Protection Association. Material is reproduced,
A half-day training program, with permission, from NFPA Standard 70E-2009 Edition,
Arc-Flash Safety, is also Standard for Electrical Safety in the Workplace, Copyright
available. Especially suitable for 2008, National Fire Protection Association, Quincy, MA
electricians and maintenance 02269. This material is not the complete and official position
technicians, you can earn 0.4 CEU. of the NFPA on the referenced subject, which is represented
only by the Standard in its entirety.

EATON CORPORATION Eaton’s Electrical Services & Systems 7


Power Xpert, PowerNet
and Foreseer Basics
Program overview Program content
The Power XpertT, PowerNetE • Configuration of devices that
and ForeseerT Basics training are able to communicate using
program focuses on connec- the Eaton Power Xpert Server
tivity. Attendee will receive Core through PowerNet Soft-
hands-on practice and tools ware. These include early
for configuring Power Xpert models of meters and
Software using components protective relays
of PowerNet and Foreseer IACET CEUs: 3.2
• Configuration of devices that
Software. It is designed for
are able to communicate using Duration: 4 days
engineers and technicians
the Eaton Power Xpert Server
who design, install and operate This training is conducted at
Core via Foreseer Software.
power management systems our Power Quality Experience
This includes UPSs and PDUs
using Power Xpert communi- Center in Warrendale, PA.
cations capabilities. It provides • Alarming and trending For tuition amounts and
a basic understanding of the for our schedule, visit the
architecture and configuration
• Configuration of Power Xpert
devices directly to the Power customer courses link at
of Power Xpert Software www.eaton.com/learning.
and its associated hardware Xpert Server Core: Power
components. Xpert Meters, Power Xpert For additional information
Gateways and UPSs and pricing of on-site training,
• Setup and configuration call 724-779-5921.
of INCOME, ModbusT and To locate your nearest Eaton
Ethernet communications distributor or sales office, visit
interface devices such as www.eaton.com/electrical.
NetLink, E-MINT, PXG600
Gateway or Power Xpert
Meters
• Configuration of Power Xpert
devices using Power Xpert
Server Core Software

8 EATON CORPORATION Eaton’s Electrical Services & Systems


Protective Relay
Testing, Basic
Program overview Program content Hands-on exercises
The Protective Relay Testing, Classroom sessions • Setup and configuration
Basic training program is for of a Doble 6150 advanced
• Power triangle calculations
maintenance technicians, relay test set
electricians, engineers or any • Phasor diagrams • Testing overcurrent relays
others who are responsible for
• CT and VT construction and (IEEET 50/51) using ABB
maintaining a safe and reliable
connections as they apply to type CO and GE type IAC
electrical power distribution
relaying and metering circuits electromechanical relays
system in an industrial or IACET CEUs: 3.2
as an example
commercial facility. • ABB and GE style relay cases
and test plugs • Setup and testing of micro- Duration: 4 days
processor overcurrent relays This training is conducted at
• How to simulate VT and CT (IEEE 50/51) using the Eaton
circuits with a relay test set our Power Quality Experience
DT3000 as an example Center in Warrendale, PA.
• Testing overvoltage (IEEE 59) For tuition amounts and
and undervoltage (IEEE 27) for our schedule, visit the
relays using ABB type CV and customer courses link at
GE type IAV electromechanical www.eaton.com/learning.
relays as an example For additional information
• Testing directional overcurrent and pricing of on-site training,
relays (IEEE 67) using an ABB call 724-779-5921.
type CR electromechanical To locate your nearest Eaton
relay as an example distributor or sales office, visit
• Testing transformer differential www.eaton.com/electrical.
relays (IEEE 87T) using an
ABB circuit shield type 87T
solid-state relay as an example
• Testing the overfrequency
(IEEE 81O) and under-
frequency (IEEE 81U)
functions of a micro-
processor feeder protection
relay using the Eaton
FP-5000 as an example
• Testing the sync-check
(IEEE 25) function of an
FP-5000 microprocessor
feeder protection relay

EATON CORPORATION Eaton’s Electrical Services & Systems 9


Smart Grid

Program overview Product content


Upon completion of the Smart • Smart Grid technology over-
Grid training program, you will view: driving factors, today’s
recognize the components of grid, grid of the future
a Smart Grid, understand the • Renewable energy: wind,
capabilities of a Smart Grid, and
geothermal, photovoltaic,
recognize the various definitions
integration of renewable
of a Smart Grid as they are given
energy sources
by the Department of Energy, Duration: 3.5 days
power generation and power • Transmission and distribution
distribution companies and by systems: energy storage and This training is conducted at
industrial users of electrical system security our Power Quality Experience
power. This training program is Center in Warrendale, PA and
recommended for technicians,
• Smart Grid technology: auto- at other locations. For tuition
engineers or anyone who is mation and control, hardware amounts and for our schedule,
interested in learning renew- implementation, choice of visit the customer courses link
able generation, integration protocol, system configuration at www.eaton.com/learning.
of renewable energy, types and testing, cyber security
For additional information
of energy storage, and tradi- • Customer empowerment: and pricing of on-site training,
tional or advanced automation demand response, smart call 724-779-5921.
and control. meters, smart appliances,
plug-in vehicles To locate your nearest Eaton
distributor or sales office, visit
www.eaton.com/electrical.

10 EATON CORPORATION Eaton’s Electrical Services & Systems


The Industrial Training Laboratory
in Warrendale, PA
Overview
Using the equipment of our • AMPGARD medium voltage
industrial training laboratory, motor control, type SJ
Eaton provides real-life, • VCP-T medium voltage
hands-on operational and
power circuit breaker, MVS
maintenance training for techni-
load-interrupter switch and
cians, electricians, equipment
EDR-3000 feeder protection
operators, engineers and safety
system in an MSB assembly
managers. We can train on Duration: 0.5 to 4.5 days
these fully functional assemblies • Liquid-immersed, unit depending upon your specific
and components: substation transformer requirement.
class KNAN/KNAF having
• A MagnumE DS low Technical and safety training
active fan controls and
voltage power circuit breaker in our industrial training lab-
a fault pressure relay
assembly having ELC-directed oratory and our Power Quality
main-tie-main transfer; • SVX9000 adjustable Experience Center is provided
zone interlocking; DigitripE frequency, adjustable on a quoted-price basis.
RMS 520, 520M, 1150+; speed motor controllers
breaker lifter; hinged For additional information
compartments; Arcflash
• Accusine active harmonic filter or for a quotation of price,
Reduction Maintenance call 724-779-5921.
• Type DS II low voltage power
SystemE; Power XpertT circuit breakers
metering devices; under-
voltage and loss-of-phase
• Freedom 2100 motor
protective relays control center

• A VCP-W medium voltage • Advantage communicating


switchgear assembly having motor control center
a 15 kV vacuum interrupter • IT. communicating motor
circuit breaker, CPT drawout control center
compartment, VTs drawout
compartment and capacitive • FlashGardT motor
trip module control center
• AMPGARDT medium voltage
motor control, type SL
contactor, reduced voltage
autotransformer type under
control of an MP-3000
motor-protection system

EATON CORPORATION Eaton’s Electrical Services & Systems 11


Eaton Corporation
Electrical Sector
1111 Superior Ave.
Cleveland, OH 44114
United States
877-ETN-CARE (877-386-2273)
Eaton.com

© 2011 Eaton Corporation Eaton is a registered trademark


All Rights Reserved of Eaton Corporation.
Printed in USA
Publication No. SA02705001E / Z11183 All other trademarks are property
June 2011 of their respective owners.

You might also like