Ie. Since bending is about minor axis, lateral torsional buckling can be ingored.
Non-factored tensile force per bolt, Ft1a = 2.59 kPa x 1.4 x 0.35 x 0.2 m x 1000
= 253.8 N
x x
Area = 60.0 mm2
Zxx = 30.0 mm3
Zyy = 200.0 mm3
Factored tesnile force per bolt, Ft2a = 1.4 x Fv x 22.5 / 10 / 1 nos. / 2 sides
= 1.4 x 612.3 x 22.5 / 10 / 1 nos. / 2 sides
= 964.4 N
P/4
H/8
H = 3^0.5 x p / 2
= 3^0.5 x 0.8 / 2
= 0.69 mm
D1 = d - 2 x 5 x H / 8
= 5.0 - 2 x 5 x 0.69 / 8
= 4.13 mm