You are on page 1of 6

Project: PROPOSED DEVELOPMENT AT

SKYCITY SITE A2 L894,


PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 12

* Check for deflection

Max. deflection, d = 5 x w x L^4 / (384 x E x Ixx)


= 5 x 1.27 x 965.0^4 / (384 x 70000 x 55827.8)
= 3.67 mm

Limiting deflection, = L / 180


= 965.0 / 180
= 5.36 mm > d = 3.67 mm OK

* Check for lateral torsional buckling

Ie. Since bending is about minor axis, lateral torsional buckling can be ingored.

* Check for M6 stud bolt (@200c/c)

Non-factored tensile force per bolt, Ft1a = 2.59 kPa x 1.4 x 0.35 x 0.2 m x 1000
= 253.8 N

Stress area, A= 20.1 mm2

Proof stress, pf = 95.0 MPa

Tension capacity, Ftc = At x pf / 3 (FOS = 3)


= 20.1 x 95.0 / 3
= 636.5 N > Ft1a = 253.8 N OK
Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 13

2.3.1 Check for connection between aluminium stiffener and cladding


(Refer to drawing no. AD-04, detail 1)

Non-factored reaction, Fv = Fv / 1.4 (Refer to section 2.3)


= 857.3 / 1.4
= 612.3 N

* Check for class 70, 2 nos. M5 S.S. bolt (Bolt A)(-c/c)

Stress area, A= 14.2 mm2

Factored shear force per bolt, Fv1a = 1.4 x Fv / 2 nos. / 2 sides


= 1.4 x 612.3 / 2 nos. / 2 sides
= 214.3 N

Shear capacity, Fv1cc = 311.0 x A


= 311.0 x 14.2
= 4416.2 N > Fv1a = 214.3 N OK

Bearing capacity, Fbec = c x d x t x pa / 1.2


= 2.0 x 5.0 x 3.0 x 130.0 / 1.2
= 3250.0 N > Fv1a = 214.3 N OK
Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 14

* Check for 3 mm thk. 6063-T5 angle section (L = 20)(section A-A)

x x
Area = 60.0 mm2
Zxx = 30.0 mm3
Zyy = 200.0 mm3

Factored bending moment, Mx = 0 Nmm

Bending moment capacity, Mxc = po x Zxx / 1.2


= 110 x 30.0 / 1.2
= 2750.0 Nmm > Mx = 0 Nmm OK

Factored bending moment, My = 1.4 x Fv x 22.5 / 2 sides


= 1.4 x 612.3 x 22.5 / 2 sides
= 9644.4 Nmm

Bending moment capacity, Myc = po x Zyy / 1.2


= 110 x 200.0 / 1.2
= 18333.3 Nmm > My = 9644.4 Nmm OK

Factored tensile force, Ft = 0 N

Tension capacity, Ftc = pa x Area / 1.2


= 130 x 60.0 / 1.2
= 6500.0 N > Ft = 0 N OK

Combine stress, = Mx / Mxc + My / Myc + Ft / Ftc


= 0 / 2750.0 + 9644.4 / 18333.3 + 0 / 6500.0
= 0.53 < 1 OK

Factored shear force, Fv = 1.4 x Fv / 2 sides


= 1.4 x 612.3 / 2 sides
= 428.6 N

Shear capacity, Fvc = pv x Area / 1.2


= 65 x 60.0 / 1.2
= 3250.0 N > Fv = 428.6 N OK
Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 15

* Check for class 70, 1 nos. M5 S.S. bolt (Bolt B)(-c/c)

Stress area, A= 14.2 mm2

Factored shear force per bolt, Fv2a = 1.4 x Fv / 1 nos. / 2 sides


= 1.4 x 612.3 / 1 nos. / 2 sides
= 428.6 N

Shear capacity, Fv2cc = 311.0 x A


= 311.0 x 14.2
= 4416.2 N > Fv2a = 428.6 N OK

Factored tesnile force per bolt, Ft2a = 1.4 x Fv x 22.5 / 10 / 1 nos. / 2 sides
= 1.4 x 612.3 x 22.5 / 10 / 1 nos. / 2 sides
= 964.4 N

Tension capacity, Ft2cc = 0.8 x 450.0 x A


= 0.8 x 450.0 x 14.2
= 5112.0 N > Ft2a = 964.4 N OK

Combine shear and tension, = Fv2a / Fv2cc + Ft2a / Ft2cc


= 428.6 / 4416.2 + 964.4 / 5112.0
= 0.29 < 1.4 OK

Bearing capacity, Fbec = c x d x t x pa / 1.2


= 2.0 x 5.0 x 3.0 x 130.0 / 1.2
= 3250.0 N > Fv2a = 428.6 N OK
Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 16

* Check for screw embedment


(Refer to drawing no. -)
5H/8
P/8
P
P/8

P/4

H/8

Diameter of screw, d= 5.00 mm

Pitch of screw, p= 0.80 mm

H = 3^0.5 x p / 2
= 3^0.5 x 0.8 / 2
= 0.69 mm

Thickness of base material, T= 3.00 mm 6063-T5

No. of pitch, n=T/p


= 3.0 / 0.8
= 3.75 nos.

D1 = d - 2 x 5 x H / 8
= 5.0 - 2 x 5 x 0.69 / 8
= 4.13 mm

Shear area, Av = n x p x D1 x (H / 8 + 5 x H / 8) x tan 30 x 2


= 3.75 x 3.142 x 4.13 x (0.69 / 8 + 5 x 0.69 / 8) x tan 30 x 2
= 29.2 mm2

Shear capacity, Fv = 65.0 / 1.2 x 29.2


= 1582.8 N > Ft1a = 964.4 N OK
Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 17

2.4 Computer analysis of 40 x 40 x 3 mm thk. aluminium stiffener (@320c/c) (Refer to Appendix A)


(Refer to drawing no. AD-05, detail 1)

Load case - WIND

Wind udl, wx = 2.59 kPa x 1.4 x 0.32 m


= 1.16 N/mm

Wind udl, wy = 2.59 kPa x 2 x 0.32 m


= 1.66 N/mm

You might also like