RESEARCH ON LIGHTNING PROTECTION AND EARTHING


OF RADIO BASE STATION
Lin Yongshuang1 Liu Jike2 Meng Qi3 Wang Zhigang2
Email: linyongshuang@jm.gd.chinamobile.com, liujike@dimpt.com, mqi@emersonnetwork.com.cn,
wangzg200@chinaunicom.cn

was no trace of burning on the damaged circuit surface,.


ABSTRACT
The paralysis of the equipment caused by the lightning
This paper explains lightning protection and earthing strike lasted 27 hours.
issues of RBS (radio base station) and discusses people’s
cognitive process to RBS’s attack by lightning through 2 REVIEW OF RBS’S LIGHTNING
four processes of Jiangmen (Guangdong Province of PROTECTION AND EARTHING
China) RBS’s lightning protection and earthing
transformation. This paper proposes the key to solve RESEARCH
RBS’s lightning protection and earthing questions China is the country with the biggest RBS number in
qualitatively and quantitatively according to the lightning
the world; it also has the most extensive thunderstorm
protection and earthing research of RBS,and the paper
days. In Guangdong Province alone, the number of
clarifies some controversial views of IEC and ITU
standards.
thunderstorm days is more than 70 and even up to 120.
Key words: RBS, Lightning Strike, Lightning Guangdong Mobile alone has more than 30,000 RBSs,
Protection, Earthing, Research so its research on lightning protection and earthing
transformation is representative, which is reviewed
1 OVERVIEW below:
Phase 1 (from 2000 to 2002): The renovation
The lightning protection and earthing technologies of program of lightning protection and earthing was to
telecommunication bureau (station) cover protection install the Class I spark gap or combined spark gap
issues of up to megavolts of lightning, tens of thousands SPD(surge protective devices) on power distribution
of high-voltage power, several hundred volts of cabinet of RBS, although the SPDs of Germany top
distribution and tens of volts or even a few volts brand were employed and the earthing resistance of
microelectronic devices. It has been concerned widely RBS was reduced, the RBSs were still struck by
because it relates to the reliable transmission of lightning and the distribution cabinets equipped with
information. Jiangmen Mobile has been researching the spark gap SPD were often burnt out as the result of
lightning protection since the 1990s. Number of the arc discharge caused by lightning. Lightning strike
thunderstorm days in Jiangmen is more than 70 per year, caused serious losses of RBS equipments in this period.
and the thunderstorm has threatened the safety of Phase 2 (from 2003 to 2004): Both the application of
communication bureau (station) for many years, for the Class I spark gap SPD and the earthing resistance
example, on June 10, 1993, Dongpaotai reduction measures did not contribute to the
Communication Center of Guangdong Jiangmen Post improvement of RBS’s Lightning protection in the
Office, which has a fifty thousands lines of SPC(stored phase 1 period, which led the lightning protection
program control) exchanges, a relatively big station in technical director to a wrong understanding that the
the 1990s, was struck by lightning. The lightning strike SPD was dispensable for renovating the RBS’s
caused the breakdown or damage of AC power rectifier, lightning protection and earthing during the second
paging transmitter wireless transceiver, NEC rectifier phase of lightning protection and earthing renovation.
voltage monitoring circuit boards, computer interface Therefore, another plan was adopted, that is to say, the
circuit boards (control terminal of mobile lightning protection and earthing renovation program
telecommunication). The most seriously damaged involved only equipotential modification, reduction of
equipment was NEC-61 local telephone SPC exchanges, earthing resistance of RBS’s grounding grid and
the main failure components were the CPU and the application of underground cables replacing previous
interface boards and the bus controlled by the CPU overhead transmission lines. The frequency of lightning
control module as well as the module backboard, there

1006-1
strike and the equipment damage caused by lightning low potential introduction is provoked. To solve the
strikes did not decrease at all in a thunderstorm year. problem, we can install SPD on these ports so as to
Phase 3 (from 2004 to 2005): Concept of integrated achieve equipotential bonding. The power and the
lightning protection and earthing of RBS’s ground grid signal lines can not be connected to the ground directly
optimization design[1] was proposed. Lightning because of electricity and signal transmission.
protection measures were taken for the power ports, Therefore, the SPD can be used to connect the power
signal ports, ground ports and earth potential back and signal lines to the ground indirectly; this kind of
striking ports of RBS. Trials have proved that the equipotential bonding belongs to transient ground with
renovation of Guangdong mobile stations’ lightning the aim to discharge the lightning current into the earth
protection and earthing has achieved noticeable results. through the SPD when the lightning occurs. The normal
Therefore, there are new ideas about such issues as the equipotential bonding of RBS can only be used for the
reduction of earthing resistance value and the metal components suitable for direct earthing; for the
application of SPD for RBS. equipotential bonding of the power and the signal lines
SPD isn’t a dispensable device; instead, it must be and the antenna feed lines that can’t be connected
installed on each outer inlet port of RBS. Besides, the directly to the earth, SPDs connected to the wires in a
selection of SPD is very critical; in the past, one always parallel manner are the best way to achieve the transient
think high of famous brand, but the application proved ground and discharge the lightning current when
that spark gap or combined spark gap SPD is unsuitable lightning happens.
for the working environment of China’s RBS and
voltage limiting SPD should be adopted. 3 CONTENT OF THE RESEARCH
Phase 4 (from March 2006 to December 2006): If the lightning protection and earthing renovation
Although great results and remarkable success in terms still focuses on earthing resistance reduction or
of lightning protection and earthing had been achieved application of different SPDs, it is impossible to solve
in phase 3, we considered whether there were any other the lightning protection problems of the RBS. For
questions needed to be resolved? The answer is yes. solving the RBS’s lightning protection issues, this paper
People’s understanding on lightning becomes clearer as holds the following main contents:
a result of the in-depth practice, but so far lightning is
still a research subject. People are constantly exploring 1) Earth potential rise and waveform of the lightning
the formation of lightning and the channel of lightning when the RBSs are struck by the direct lightning
strikes. However, our knowledge about lightning keeps flash;
increasing; for example, we have been not sure about 2) Division of lightning protection zone and the
equipotential, in fact, the equipotential bonding can be equipment insulation;
classified into two categories: one is the steady-state 3) Relation between the maximum discharge current
equipotential formed through direct connection; the of SPD and the earthing;
other is obtained by connecting with SPD to make the
4) Handling principles for antenna feeder earthing
ground loop stay disconnected at other times; when
point.
over-voltage occurs due to lightning, earthing resistance
decreases sharply so as to discharge the lightning 5) Selection of SPDs.
current through the earthing system. In terms of the first
category, the equipotential concept is that no matter 4 RESEARCH ON RBS’S LIGHTNING
how high the potential is in the potential plain where PROTECTION AND EARTHING
the equipment room located (no matter it locates in the
4.1 Earth potential rise and waveform of
top or the bottom of the building), it is acceptable as
lightning while RBS is struck by direct
long as all the equipment and facilities inside the
lightning flash
equipment room are at the same potential or the
potential difference can not be high enough to cause First of all, when the direct lightning flash strikes the
equipment damage. The reference point is very lightning rod of the tower, lightning current flows
important; earthing connection may not be tapped from through the tower and discharges through the grounding
the downstairs; it is better to set the reference point on grid; the maximum current can be up to 200 kA, and
the floor where the equipment room is located; it is not creates tens of thousands or even millions of volts of
necessarily to follow the common view that the earthing earth potential rise in the RBS’s grounding grid.
electrode(s) buried in the earth should be used for the Suppose that the described direct lightning flash has a
reference points. As for the other category of current waveform of 10/350μS, and when it flows
equipotential: if there is no incoming power or signal through the tower, the 10/350μS waveform changes
line, potentials inside the equipment room are the same; because of the inductive impedance of the tower, and
if there are led-in power and signal lines, problem of when it flows into the earth, the waveform of lightning

1006-2
current changes again. be applicable for telecommunications bureaus (or
As the current flows into the earth, the 10/350μS stations); for example, voltage withstand level of high-
lightning current waveform of the original direct voltage equipment, lines and lightning protectors are
lighting changes due to the inductive impedance of the different, so the same lightning current level may not
tower and the inductance and capacitance of the have any impact on the switchgear of electric power
earthing electrodes. The changed lightning current and substation, but may be strong enough to damage the
the earthing resistance generate earth potential rise to supply system of communication equipment.
the infinity points, namely, earth potential back striking , Besides, in communication bureaus (stations), IEC
belonging to the quadratic effects of lightning. Whether insulation grade of the equipment is also not so
the outgoing high potential or the incoming low applicable, because electrical distribution equipment
potential, earth potential rise on the wire generated there may contain components with both 6 kV
while the lightning current flows through the tower withstand voltage and only 500 V or even a few volts of
create ultimately tens of thousands volts or even withstand voltage. In actual lightning disasters, it is, in
millions of volts of common voltage or differential many cases, the so-called bulky supply equipment at the
voltage. Earth potential rise of ground grid impacts on front of telecommunication power supply system that is
the RBS outgoing wires by means of resistive coupling, damaged. If lightning protection designers of
which has nothing to do with the lightning current telecommunication power supply system confine the
waveform that flows into the earth through tower while voltage step by step according to the protection level,
lightning strike, namely, irrelevant to the 10/350μS from 6 kV, 4 kV, 2.5 kV to 1 kV of the main protected
waveform that has been under endless discussion. equipment [3], lightning-striking damage may be
Therefore, the ground voltage or ground-to-line voltage directly caused to the telecommunication power supply
on the outgoing wire can be described by 1.2/50μS equipment.
simulated lightning voltage waves. The 1.2/50μS As the automatic control technology becomes
simulated lightning voltage waves are corresponding to increasingly popular, protection levels of 6 kV and 4 kV
8/20μS simulated lightning current waves in IEC are just in connection with the main components of the
standards. So the Class I SPD is acceptable as long as it equipment, such as the cutters and switches. Taking the
can withstand the 8/20μS current. diesel engine generator for example: nowadays, most of
In terms of the lightning current led in along the the diesel engine generator boxes control the switches
outgoing lines, no matter what form the lightning may automatically after sampling mains supply through the
be, no matter whether the direct lightning strikes on the sample loop. Undoubtedly, lightning protection level of
distribution lines or not, no matter whether the lightning the switch is relatively high; however, the sample loop
impacts on the RBS’s equipment by way of is often damaged by lightning strike because the low
electromagnetic fields or not, no matter whether the voltage circuits in the high voltage circuit are treated in
lightning current flows in along the incoming power the same way as the switches for lightning protection.
lines and optical fiber cables, the direct lightning can’t Therefore, we should regard automatic transfer switch
strike on the power distribution lines near the RBS with (ATS) as low voltage equipment and enhance the
iron towers (the most severe condition) as the result of protection of it, especially the protection level of the LC
the protection function of the tower, especially in the components (The similar devices include automatic
case of the shielded and buried cables adopted for the voltage regulator, etc.) in ATS. Therefore, insulation
RBS distribution lines; according to the lightning zone level of IEC can not be used for telecommunications
concept, it is in the LPZ0B~LPZ1 zone[2], so the power supply system directly.
lightning wave should be the 8/20μS waveform rather
than the so-called 10/350μS one. Therefore, at this 4.3 Relation between the Maximum Discharge
point, the 8/20μS waveform should be used to describe Current of SPD and the Earthing
the lightning wave on SPD. In addition, if the lightning Earthing resistance value of RBS is not as important
current amplitude of the first lightning is higher enough, as before in China because the updated standard
the overhead lines will flash over to the ground. Once requirements for earthing[4]. In spite of that, the RBS
the flash over occurs, the original 10/350μS waveform earthing system is still indispensable, and the optimum
can not keep unchanged. Moreover, the lightning area of grounding grid is indeed very important.
energy will degrade quickly while it discharges along No matter how large the area of a grounding grid is,
the distribution line. the surface of earthing electrode can be taken as
equipotential surface approximately in terms of power
4.2 Division of Lightning Protection Zone and
frequency; therefore, area of the ground grid can be
Equipment Insulation
fully utilized. However, the grounding grid consists of a
IEC Division of Lightning Protection Zone may not couple of earthing electrodes below the ground; under

1006-3
the surge current and the constant soil resistivity and zone concept, the direct lightning can’t strike the
permittivity, the impulse equivalent radius of the antenna feeder directly. In order to realize equipotential
grounding grid is a constant, while the impulse bonding and proximity earthing, tens of meters of
equivalent radius of the grounding grid is much smaller feeders and metal outer sheath of coaxial cables are
than the equivalent radius of the area of grounding grid, required to be connected to the ground at the antenna,
that is, under the surge current, a small area of ground the point just separating from the tower and the inlet to
grid are utilized. In terms of the power frequency, the the equipment room respectively; if the antenna feeder
reason why the earthing resistance is in inverse and other coaxial cables are longer than 60 m, it is
proportion to the square root of the ground grid area is advisable to add an extra earthing point at the middle
that the potential on ground grid is well-distributed and part of the tower; both ends of outdoor cabling racks
all earthing bodies play a role in discharging the current should be connected to the grounding grid as well.
and grounding grids are fully utilized. Nevertheless, the
situation is different under the lightning current. The Antenna Feeder
inductive effect of the earthing electrode makes the
potential of grounding grid uneven; the farther from the
lightning current injecting point, the lower the potential
Feeder earthing point
on earthing electrode is (even zero). The change follows
a exponential decrement curve, and only the grounding
grid close to the lightning current injecting point plays a Outdoor earthing RBS equipment room
role of discharging the current and the discharging bar
efficiency is in direct proportion to the potential
distribution in this area. Grounding grid
Lightning current flows into the earth through the Figure1.Tower besides RBS equipment room
earthing system, the grounding grid provides a current
discharge channel. As the earthing resistance increases, According to the principle of electromagnetic
earth potential back striking rises, and common voltage compatibility, the antenna feeder should be connected
or differential voltage on the power distribution lines to the ground bar at the outside of the inlet to the
imposed by ground potential increase. Strong electric equipment room, which is shows in Figure 1. As for the
field is formed near the earthing electrode because of tower built on the equipment room, under-tower
the large current amplitude, besides, the equivalent soil earthing point of the antenna feeder is also very
resistivity is affected by the electric field strength as important.
well: with the increase of the electric field strength, that Lightning rod
is, with the increase of current density, the spark over in Antenna tower

the soil may occur which will lead to the decrease of the
soil resistivity. When the electric field strength near the
earthing electrode reaches a certain value, the
Lightning
relationship between voltage and current isn’t linear but wire
nonlinear, equivalent to the decrease of earthing
resistance. Earthing resistance is in inverse proportion
to the lightning protection level of the outgoing lines, so
reducing the earthing resistance of RBS is the
prerequisite for improving the lightning protection level
Figure2.Lightning current distribution model
of lines. Under the situation of high resistivity,
optimized design of grounding grid should be adopted; It can be seen from the distribution model of the
it seems that the requirements for the earthing resistance lightning current that if the lightning striking at the
are ignored, but in fact the earthing resistance is still lightning rod, 95% of the lightning surge current flows
relatively high, leading to the rise of the ground through the columns and walls of the building, as
potential of the grounding grid, thus it is necessary to shown in Figure 2. Moreover, nearly all lightning
improve the maximum discharge current of SPD due to current that strikes the building is concentrated on the
high earth potential back striking. external walls; the current through the middle columns
only accounts for several percentage. Nearly all the
4.4 Handling Principles for Antenna Feeder lightning current inside the building flows along the
Earthing Point vertical columns with little current flows horizontally
except for the roof. For the RBS with nearby tower, the
Antenna feeders of RBS are under the protection of lightning current through the down conductor accounts
lightning rods; according to the lightning protection for just a small percentage, the electromagnetic field

1006-4
induced current of antenna feeder system protected by 4.5 DC Protectors Are Indispensable in
the tower is even smaller. Lightning-Prone Areas
Calculation demonstrates that in the case the
As for the ground ports of equipment under the
lightning current of the direct lightning is 100 kA, if
impact of instantaneous potential rise, DC power supply
lightning current that flows through 4 square-tower
of equipment in RBS equipment room generally
steel structures is distributed well, current value of each
includes two types: 24 V (DC negative earthing) and -
tower leg is 25 kA; therefore, the current on the antenna
48 V (DC positive earthing), and these two types of
feeder induced by the lightning electromagnetic field is
power supply need to connect to the ground. When
no more than 1 kA. Through the calculation for tubular
lightning discharges through the ground grid, potential
towers, triangular towers and square-towers mentioned
will rise sharply in a short time and thus the transient
in Section 4.5, we know that the transverse voltage
potential difference between the positive and the
scope of feeder cable is just in the range 0.006~0.050
negative electrodes of the DC power supply becomes
kV. very large and may damages the sensitive components
In terms of the tower erected on the RBS room, if the of the equipment (such as rectifier modules and
under-tower earthing point of the antenna feeder is not transceivers). As the rise of ground potential sometimes
directly on the grounding grid, but on one corner of the will damage the equipment from the DC output port of
tower body, the distribution of lightning current can be switching power supply, or from the DC input port of
quite different. Lightning current that originally flows telecom equipment such as GSM, the DC SPDs should
through the tower body and columns of the building be installed on both ends to form transient equipotential
into the earth with the value of 25 kA per tower is between the positive and negative electrodes of DC
divided into two channels: one is to the earth through power supply and the earth. Prevent the earth potential
the columns of the building, and the other is to the earth back striking from damaging the equipment. In the past,
in the form of current that is no more than 1 kA in terms of resistive coupling, people have emphasized
induced by the lightning electromagnetic field on the on the theoretical analysis on the impacts of the rise of
feeder and lightning current that flows into the earth ground potential; through statistics on the practical
through the tower body, tower corners to feeder, application, we found little literature on damaged DC
equipment enclosures and earthing lines; in this case, SPDs of switching power supply of RBS. The Figure 4
the current will change into thousands of amperes (even shows one case of the damaged DC SPDs on the
higher than 10 kA), that is, the channels and levels that switching power supply by lightning. It can be seen
the lightning current flows into the equipment room is from the picture that the energy created by the rise of
increased. For Jiangmen Mobile, towers on equipment the ground potential is considerable. Therefore, to
rooms of RBS are dominant. In the lightning protection protect the equipment, the switching power supply DC
and earthing renovation, antenna feeder earthing lines SPD is indispensable in areas with intensive
formerly connected to the tower corners are thunderstorm days and strong lightning density,
reconnected to the ground grids directly, as shown especially those RBSs with iron towers.
Figure3.

Feeder Feeder Tower


Connected
Tower to the tower
corner

Feeder window Feeder window


Outdoor earthing bar Column
RBS equipment room
RBS equipment room Figure 4 . The damaged DC SPD
Grounding grid
Ground grid
5 CONCLUSION
The data on the implementation of the four phases of
lightning protection and earthing renovation from 2000
Figure 3 . Tower built on RBS

1006-5
to 2009 in Jiangmen (Guangdong Province, China) are
very persuasive. From 2005 to 2009, Jiangmen has
conducted lightning protection and earthing renovation
involving 600 RBSs for pilots. As a result, the RBSs
underwent the comprehensive lightning protection and
earthing transformation have report not one case of
equipment or Class I voltage limiting SPD box damage
by the lightning after the operation trial from 2006 to
2009, although the RBSs are also still frequently struck
by lightning. Most of these RBSs were damaged by
lightning once a year or several times a year in the past,
so they are especially representative and are singled out
for the pilots and their renovation results are persuasive.

6 REFERENCES
[1] Liu Jike, Zhanle, “ Earthing for Mobile Communication
Base Station ”, Supplement of Designing Techniques of
Posts and Telecommunications, Lightning and
Electrostatic Ablum pp.48 – 53, June 2002.
[2] IEC 62305-1,Protection Against Lightning ,Part 1:
General principles.
[3] IEC 60664-1: 2007.4 Insulation Coordination for
Equipment within Low-voltage Systems. Part 1:Principles,
Requirements and Tests,
[4] YD/T5098-2005 Specifications for Engineering Design
for Lightning Protection and Earthing Design for
Telecommunication Bureaus (Station)