You are on page 1of 1

AHMEDABAD TEXTILE INDUSTRY'S RESEARCH ASSOCIATION

P .O. Ambawadi Vistar, Ahmedabad-38o 015. thdia.


Ph : (07e) 263o7e2E7i3i,'3,'d;?,i3.1;t'4"(Fli[,Iffi:"1f,].,:'x: (07e) 2oso4o7t

TEXTILE TESTING LABORATORY


ISO/IEC 1702s :2017 NABL ACCREDITED
(Linked to Ministry of Textile)
Cert"No.TC.S()!}7
EErflGnq Er€[ sqlrr w5iun fca,nq
?*. sfr. sri6rrqr€ RRR, sr€qqffi-3gg g1g. ERir.

Format No.:TT 10/01/00

ULR NUMBERTC 5097 20 2 OOOO3O74P


Test Report No: A/T/O474 ?OZO-2L I Date: 18.o7.2o2o
M ill/Company/Customer: Shri Sumit Mall
Times Fibrefil! Pvt. Ltd.
Module 28, 13th Floor
Address & Contact Details: Tower - 1, Bengal Eco-Intelligent park
Sector-V, Salt Lake,
Kolkatta - 700 064
Email : sumit. mall@timesfiberfill.com
Sample forwarding Letter No. & Date: Nil dated Nil
Date of receipt of Sample: L5.O7.2020
Lab Sample Code No. TT-9368

Number of Samplcs : 01
Date of Performance of test(s): 15.07.2O2O to 18.07.2020
Sample Description: Fabric Sample - Geo Touch - Geo Textile
Discipline / Group : Mechanical Testing / Textiles

Sr. Test Parameter Unit Test Method Average Test


No. Results
1 Fabric Weight 9/m2 ASTM D 5261 t82.4
2 Thickness mm ASTM D 5199 1.40
(Under 2koa)
3 Grab Tensile Strength N ASTM D 4632
Machine Direction 244.42
Cross Direction L96.34
4 Grab Tensile Elongation o/o
Machine' Direction t49.02
Cross Direction 161.20
5 Water Permeability (Flow) ASTM D 4491
normal to plane (Falling Head
s-1 Method)
4.058
6x Apparent Opening Size (AOS) Micron ASTM D 4751 L40

xNon-NABL accredited Test Parameter

Samoles are not drawn bv AITRA. Result relates to the samples tested. Thereoortshall not be Grey Scale Rating Pilling Rating
reprdOuceo except in fufi, without wriften approval of the laboratory. Tr6affilslstrictly 5. Excellent 4. Good 5. No Pilling 4. Slight Pilling
Fair
confidential and for technical information of client only. Not for Advertisement, Promotion, 3. 2.Poor 3. Moderate Pilling 2. Severe Pilinl
Publicity or Litigation, Please write Test Report number and date for all future conespondence. 1. VeryPoor 1. Very Severe Pilling
sample conditloned and tested dt tomp. ol27*2" (instead ot 20121t2110 c) and 65*2% RH wherever lso / ASTM'/ AATCC test methods adopted
l