You are on page 1of 3

INPUT THE FOLLOWING REQUIRED PARAMETERS: Values: [Eng]

Ac (Area of the Concrete Section) 450


Ic (Inertia of the given section) 33750
Sb (Section Modulus @ e) 0
fpu (Ultimate Strength of Prestressing Tendons): 270000
fpy (Yield Strength of Prestressing Tendons): 0
Eps (Modulus of Elasticity of the Prestressing Tendons): 27000000
f'c (Specified Compressive Strength of the Concrete): 6000
f'ci (Initial Specified Compressive Strength of the Concrete): 4500
L (Span of the Prestressed beam): 50
Aps (Area of the Prestressing Tendons): 1.53
Wd (Dead Load): 468.75
Wsdl (Superimposed Dead Load): 375
Wll (Live Load): 0
Anchorage Seating Wd: 0
Change in Area: 0
e (Eccentricity of the Prestressing Force): 11
RH: 70
V/S at time t 2

ELASTIC SHORTENING (fpES) for PRETENSIONED MEMBERS


Pi (Initial Prestressing Force): 309825
Md (Moment due to Self-weight): 1757812.5
r (radius of gyration): 75
fcs (Stress at the centroid of the prestressing tendon): -1226.4
Ec (Initial Elasticity of Normalweight Concrete) 3823676.24152464
n (Initial Modular Ratio): 7.06
ES (Loss due to Elastic Shortening) -8659.94

ELASTIC SHORTENING (fpES) for POST-TENSIONED MEMBERS


n (No. of Jacking): 2
ES (Loss due to Elastic Shortening) -4329.97

CREEP LOSS (fpCR) using ACI-ASCE Method


Msdl (Moment due to Superimposed Dead Load) 1406250
fcsd (Stress at the centroid of the tendon due to Msdl) 458.3
Kcr for Normalweight Concrete: 2
Ec (Elasticity of Normalweight Concrete) 4415201.01467646
n (Modular Ratio): 6.12
CR (Loss due to Creep) 9401.0544

SHRINKAGE LOSS (fpSH) using KHS Method


Ksh value: 1
fpSH (Loss due to Shrinkage) 5844.96
Units Note:
Sq. inches Can be obtained from given or manual computation
Inches^(4) Can be obtained from given or manual computation
Inches^(3) Can be obtained from given or manual computation
psi Can be obtained from given or manual computation
psi Can be obtained from given or manual computation
psi Can be obtained from given or manual computation
psi Can be obtained from given or manual computation
psi Can be obtained from given or manual computation
ft Can be obtained from given or manual computation
Sq. inches Can be obtained from given or manual computation
lbs/ft Can be obtained from given or manual computation
lbs/ft Can be obtained from given or manual computation
lbs/ft Can be obtained from given or manual computation
Can be obtained from given or manual computation
Can be obtained from given or manual computation
in Can be obtained from given or manual computation
Can be obtained from given or manual computation
Can be obtained from given or manual computation

EMBERS
Can be obtained from given or manual computation
lbs x in
Inches
psi
psi
unitless
psi

EMBERS
unitless Can be obtained from given or manual computation
psi Can be obtained from given or manual computation

lbs x in
psi
2.00 (for pretensioned) and 1.60 (for post-tensioned)
psi
unitless
psi

1.00 (pretensioned) and use Table 3.6 (for post-tensioned)


psi