You are on page 1of 29

Automatic intermittent

gear pump
AMO-II-150S
Automatic intermittent gear pump without
controller. Capable of working with a wide
range of oil viscosities.
[1.8ℓ] [3ℓ]

Model Reference Model

AMO 150S Model Part Number

Reservoir Mounting AMO-II -150S-1 202067


Voltage Poition AMO-II-150S-1-3 202069
1 AC100Vφ1 Blank Resin AMO-II-150S-1-P 202071
2 AC200Vφ1 F Foot Mount AMO-II-150S-1-P-3 202073
B Wall Mount AMO-II-150S-2 202068
Pressure Switch *Metal reservoir only AMO-II-150S-2-3 202070
Blank Without Pressure Switch AMO-II-150S-2-P 202072
Reservoir capacity
P With Pressure Switch AMO-II-150S-2-P-3 202074
Blank 1.8ℓ Resin reservoirs
3 3ℓ Resin reservoirs
30 3ℓ Metal reservoirs
40 4ℓ Metal reservoirs Specifications
80 8ℓ Metal reservoirs
*Pump is installed on the Discharge 150mℓ/ min (50Hz), 180mℓ/ min
right side, if a metal volume (60Hz)
reservoir is selected. Pump
Discharge 2.0Mpa (20kgf/cm2) 284psi
pressure
Directions for use
AC100Vφ1/0.83A, AC200Vφ1/0.41A
Voltage/ (50Hz)
This pump unit requires a separate control circuit to operate.
ƒƒ current AC100Vφ1/0.64A, AC200Vφ1/0.33A
Motor
Do not remove the oil fill strainer in order to keep the pump clear of
ƒƒ (60Hz)
foregn matter.
Output 20W (50Hz/ 60Hz) Condenser Motor
Replace the suction filter at least once a year.
ƒƒ
Oil viscosity varies with oil temperature. Be sure to use oil within the
ƒƒ Contact type (NO) ON at low level
Oil level
working viscosity range. Refer to the viscosity table. (P.237) switch Contact capacity 0.5A AC
Do not use any special additive-contained oil, water soluble oil,
ƒƒ DC200V/30W smaller
or solvent. Emergency
detection Contact type (NC)
ƒƒPeriodically check the oil in the reservoir for impurities. Pressure Operating pressure: 1.7MPa OFF
Replace it, if necessary, with fresh oil immediately. switch Reset pressure: 0.9MPa ON
Be sure to clean the reservoir before replacing oil. Contact capacity AC DC250V/3A
ƒƒMake sure that proper voltage is applied.
ƒƒDo not over tighten the discharge joint. Discharge Max. Discharge time:99sec
time Min. Interval time:1min
ƒƒ Refer to the torque table. (P. 251)
ƒƒ Low-oil viscosity versions are available. Contact LUBE for information. Working vis- 68-1800mm2/S (50Hz)
cosity range
* Should the pump malfunction, contact LUBE for consultation.
Reservoir 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
capacity
Weight 1.8ℓ Reservoirs: 3.2kg 3ℓ Reservoirs: 4kg (plastic)

Related parts
For MO2(C) Valve For MO Valve For MOS Valve

MO2(C) Metering JVPA Junction MO Metering valve: PV Junction MOS Metering valve PVS Junction MB Metering valve MIX-S Metering valve
valve: P.115 : P.116 P.117 : P.118 : P.119 : P.121 : P.123 : P.127

F-3D Filter Pressure gauge Tubing Compression parts Adapters Reservoirs


: P.181 : P.184 : P.203 : P.201 : P.207 : P.171

109
Dimensional drawing

Large Machines
Injector (PDI) System for
Positive Displacement
275 Wiring port
190 Wiring port
88.5

89
143.5
124

Discharge port
Discharge port
RC1/8
RC1/8

Pressure gauge installation port Oil fill cap Oil fill cap
Pressure gauge installation port
RC1/8 167 Part Number RC1/8 Part Number
529409 529409

Option / Pressure gauge Option / Pressure gauge


PB-50B PB-50B
234
170

Installation hole
2-φ9
Installation hole
2-φ6.5
2 3
LUBE
2 3 1 4
Strainer
Discharge port
LUBE
1 4 0 MPa 5

Strainer
0
Part Number
0 MPa 5
RC1/8
Discharge port 521037
264

Part Number
RC1/8 521037
261

174
172

Suction filter set Suction filter set


Part Number 489011 Part Number 489011
[1.8ℓ] [3ℓ]

Parts for connecting to the discharge port

or
CB-6 CS-6 SA6-20 EA6-22

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

Hydraulic circuit drawing Wiring diagram

PG

Emergency output
Power E OL COM P/SW
RV

M
1 2 3 4 5 6

110
Automatic intermittent gear
AMO--III DS
Capable of operating over a wide viscosity range.
Digital display gives on sight visual indication.
Interval can be a function of time or count.

[1.8ℓ] [3ℓ]

Model Reference Specifications

Dis-
charge 150mℓ/min (50Hz), 180mℓ/min (60Hz)
volume
Voltage Reservoir Mounting Poition Pump
1 AC100Vφ1 Blank Resin Dis-
charge 2.0MPa/284psi (safety valve setting)
2 AC200Vφ1 F Foot Mount pressure
B Wall Mount AC100Vφ1/0.83A, AC200Vφ10.41A (50Hz)
*Metal reservoir only
Power AC100Vφ1/0.64A, AC200Vφ1/0.33A (60Hz)
Motor
Reservoir capacity Output 20W (50Hz/ 60Hz) Capacitor motor
Blank 1.8ℓ Resin reservoirs Discharge time adjustable range: 1-99 seconds
Timer
3 3ℓ Resin reservoirs Counter Interval time adjustable range: 1 to 9999 minutes
30 3ℓ Metal reservoirs 1 to 9999 counts
40 4ℓ Metal reservoirs Emergency Contact type (NO)
80 8ℓ Metal reservoirs output Contact capacity AC250V 1.5A
*Pump is installed on the right Oil level Contact type (NO) ON at low level
side, if a metal reservoir is Emer- switch
selected. Con- gency
Model troller Contact type (NC)
detection Prerssure Operating pressure: 1.7MPa OFF
switch Reset pressure: 0.9MPa ON
Model Part Number
INTER-
AMO-III DS-1 285301 display: 'INT'
Liquid VAL
AMO-III DS-1-3 285303 crystal DISCHARGE display: 'DIS'
AMO-III DS-2 285302 display Low oil level: 'OILLEVEL ERR'
ALARM
AMO-III DS-2-3 285304 Low pressure: 'PRESSURE ERR'
Working
Low viscosity oil pump (On the page of AMO-IIIDSL) viscosity 68-1800mm2/S (50Hz)
range
Part No. Voltage Tank Working vis­
No Model Reservoir 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
capacity cosity range
capacity
1 AMO-IIIDSL-1 285331 100V 1.8L 10 ~ 1800mm2/S
2 AMO-IIIDSL-2 285332 200V 1.8L 10 ~ 1800mm2/S Weight 1.8ℓ Reservoirs: 3.2kg 3ℓ Reservoirs: 4kg
3 AMO-IIIDSL-2 285333 100V 3.0L 10 ~ 1800mm2/S
4 AMO-IIIDSL-2 285334 200V 3.0L 10 ~ 1800mm2/S

Directions for use


Do not remove the oil fill strainer in order to keep the pump clear of
ƒƒ Periodically check the oil in the reservoir for impurities. Replace it,
ƒƒ
foreign matter. if necessary, with fresh oil immediately. Be sure to clean the reservoir
ƒƒReplace the suction filter at least once a year. before replacing oil.
ƒƒOil viscosity varies with oil temperature. Be sure to use oil within the ƒƒMake sure that proper voltage is applied.
working viscosity range. Refer to the viscosity table. (P.237) ƒƒDo not over tighten the discharge joint.
ƒƒDo not use any special additive-contained oil, water soluble oil, ƒƒ Refer to the torque table. (P. 251)
or solvent. ƒƒ Low-oil viscosity versions are available. Contact us for information.
* Should the pump malfunction, contact LUBE for consultation.

Related parts
For MO2(C) Valve For MO Valve For MOS Valve

MO2(C) Metering JVPA Junction MO Metering valve: PV Junction MOS Metering valve PVS Junction MB Metering valve MIX-S Metering valve
valve: P.115 : P.116 P.117 : P.118 : P.119 : P.121 : P.123 : P.127

F-3D Filter Pressure gauge Tubing Compression parts Adapters Reservoirs


: P.181 : P.184 : P.203 : P.201 : P.207 : P.171

107
Exterior features of the controller Hydraulic circuit drawing

Large Machines
Injector (PDI) System for
Positive Displacement
LCD RV

M
“RESET & FEED”
“UP” key key

“DOWN” key “Enter” key

Wiring diagram
Operation panel of the controller

LCD shows the below: Power E Emergency Count in


output (Only count in model)
INTERVAL → INT
DISCHARGE → DIS
ALARM → Low oil level OILLEVEL ERR
Low pressure PRESSURE ERR

Dimensional drawing

275
190 234
170
89
88.5

143.5

Oil fill cap Oil fill cap


124

Part Number with Part Number


with 529409 P/S 529409
Discharge port P/S Discharge port
Rc1/8 Rc1/8

Pressure gauge installation port 167 Pressure gauge installation port


Rc1/8 Rc1/8

Installation
hole
Installation hole 2-φ9
2-φ6.5

Strainer Strainer
279
271

Part Number Part Number


521037 521037
174
172

Suction filter set Suction filter set


Part Number 489011 Part Number 489011
[1.8ℓ] [3ℓ]

Parts for connecting to the discharge port

or
CB-6 CS-6 SA6-20 EA6-22

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

108
Automatic intermittent piston pump
MMXL-III
Automatic intermittent pump incorporating a small energy-­
saving motor. Interval is controlled by the RPM of the motor
so no external controllers or timers are needed. Widely used
for small machines in many different industries.

[CE]

Model Reference Specifications

MMXL CE Discharge 0.2-1.0mℓ/stroke


volume 1.5-2.5mℓ/stroke
Pump 2.5-5.5mℓ/stroke
Discharge volume
Reservoir Mounting Poition Discharge 0.3MPa
1 1mℓ
Blank Resin pressure
2 2.5mℓ
F Foot Mount AC100Vφ1/50mA, AC200Vφ1/25mA (50Hz)
5 5.5mℓ Motor Power
B Wall Mount (Other voltages AC100Vφ1/42mA, AC200Vφ1/18mA (60Hz)
Interval (50Hz/60Hz) *Metal reservoir only available.) Output 3W Synchronous Motor
A 3min/2min24sec Pump Position
B 6min/4min48sec Contact type A contact (NO) ON at low level
L Pump position-Left Emergency Oil level Contact capacity 0.5A, AC DC200V/30W
C 15min/12min R Pump position-Right detection switch smaller
D 30min/24min Voltage *Metal reservoir only
Operation rating Continuous
E 60min/48min 1 AC100V φ1 Reservoir capacity
F 120min/96min 2 AC200V φ1 Blank 1.8ℓ Resin reservoirs Working
viscosity 32-1300mm2/s
Oil level switch 3 3ℓ Resin reservoirs range
Blank Without 30 3ℓ Metal reservoirs
Reservoir
L With 40 4ℓ Metal reservoirs 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
capacity
80 8ℓ Metal reservoirs
Weight 1.8kg (With 1.8ℓ Reservoirs )
Protection class IP54 (CE Approved type)

Model

Model Part Number Model Part Number Model Part Number


MMXL-III CE-1A-1 367001 MMXL-III CE-1D-1L 367058 MMXL-III CE-2A-2 367025
MMXL-III CE-1A-1L 367055 MMXL-III CE-1D-2 367010 MMXL-III CE-2A-2L 367079
MMXL-III CE-1A-2 367007 MMXL-III CE-1D-2L 367064 MMXL-III CE-2B-1 367020
MMXL-III CE-1A-2L 367061 MMXL-III CE-1E-1 367005 MMXL-III CE-2B-1L 367074
MMXL-III CE-1B-1 367002 MMXL-III CE-1E-1L 367059 MMXL-III CE-2B-2 367026
MMXL-III CE-1B-1L 367056 MMXL-III CE-1E-2 367011 MMXL-III CE-2B-2L 367080
MMXL-III CE-1B-2 367008 MMXL-III CE-1E-2L 367065 MMXL-III CE-2C-1 367021
MMXL-III CE-1B-2L 367062 MMXL-III CE-1F-1 367006 MMXL-III CE-2C-1L 367075
MMXL-III CE-1C-1 367003 MMXL-III CE-1F-1L 367060 MMXL-III CE-2C-2 367027
MMXL-III CE-1C-1L 367057 MMXL-III CE-1F-2 367012 MMXL-III CE-2C-2L 367081
MMXL-III CE-1C-2 367009 MMXL-III CE-1F-2L 367066 MMXL-III CE-2D-1 367022
MMXL-III CE-1C-2L 367063 MMXL-III CE-2A-1 367019 MMXL-III CE-2D-1L 367076
MMXL-III CE-1D-1 367004 MMXL-III CE-2A-1L 367073 MMXL-IIICE-2D-2 367028

Related parts

Flow unit PJ junction Tubing Pressure gauge Filter FX1 Filter FY20 Pressure switch Compression parts
: P.149 : P.164 : P.203 : P.184 : P.181 : P.181 : P.185 : P.201

Adapters Reservoir
: P.207 : P.168

135
Model Dimensional drawing

Model Part Number


Discharge port M8×1
MMXL-III CE-2D-2L 367082
(φ4Tubing)
MMXL-III CE-2E-1 367023 16
166
MMXL-III CE-2E-1L 367077
MMXL-III CE-2E-2 367029 Ground terminal

56
Ground mark
MMXL-III CE-2E-2L 367083

chines with intermittent delivery


compact system for small ma-
(SLR) Single Line Resistance
Wiring port
MMXL-III CE-2F-1 367024
MMXL-III CE-2F-1L 367078

124
MMXL-III CE-2F-2 367030
MMXL-III CE-2F-2L 367084
MMXL-III CE-5A-1 367037
Oil fill cap Instant feed button
MMXL-III CE-5A-1L 367091 Part Number
MMXL-III CE-5A-2 367043 529409

MMXL-III CE-5A-2L 367097 Terminal box


(with cover)
MMXL-III CE-5B-1 367038 72.5 72.5
MMXL-III CE-5B-1L 367092
3-φ6.5
MMXL-III CE-5B-2 367044 Installation Packing
hole G1/2
MMXL-III CE-5B-2L 367098
MMXL-III CE-5C-1 367039

28
MMXL-III CE-5C-1L 367093
MMXL-III CE-5C-2 367045

218
MMXL-III CE-5C-2L 367099
MMXL-III CE-5D-1 367040
145

MMXL-III CE-5D-1L 367094


MMXL-III CE-5D-2 367046
MMXL-III CE-5D-2L 367100
MMXL-III CE-5E-1 367041
MMXL-III CE-5E-1L 367095 Suction filter set
MMXL-III CE-5E-2 367047 Part Number 489010
Strainer
MMXL-III CE-5E-2L 367101 Part Number 521037
MMXL-III CE-5F-1 367042
MMXL-III CE-5F-1L 367096
MMXL-III CE-5F-2 367048 [CE]
MMXL-III CE-5F-2L 367102

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

Directions for use Replacement Motor Model


Oil viscosity varies with oil temperature. Be
ƒƒ
sure to use oil within the working viscosity Interval 3min 6min 15min 30min 60min 120min
range. Refer to the viscosity table. (P.237) Motor RPM (50Hz) 20 10 4 2 1 1/2
Do not use any oil containing special
ƒƒ
­additives, water soluble oil, or solvent. Model M-A1 M-B1 M-C1 M-D1 M-E1 M-F1
ƒƒPeriodically check the oil in the reservoir for 100V Part
impurities. Replace with fresh oil immediately, Number
521210 521194 521193 520062 520061 520060
if necessary. Be sure to clean the reservoir Replacement
before oil adding new oil. Motor Model Model M-A2 M-B2 M-C2 M-D2 M-E2 M-F2
ƒƒMake sure that proper voltage is applied. 200V Part
ƒƒDo not over tighten the discharge joint. Refer 521328 521196 521195 520067 520066 520065
to the tightening torque table. (P.251) Number
ƒƒDo not press the discharge volume adjusting
knob down by force.
ƒƒAdjust discharge volume only when the Hydraulic circuit Wiring diagram
­piston is fully relaxed (The knob is at the
lowest position.). drawing
ƒƒ Replace the suction filter at least once a year. M E
M
ƒƒ Do not remove the oil fill strainer in order to
keep the pump clear of foreign matter.
U V OL OL U V OL OL

* Should the pump malfunction, contact LUBE for consultation.

Power Connection Power Connection


input output input output

[Normal type] [CE type]

136
Discharge Volume Adjustment

1. Loosen lock-nut by turning it counter-clockwise.


Decrease Increase 2. After loosening lock-nut, turn and adjust the connecting rod
to the desired discharge volume and tighten lock-nut.
3. Turn clockwise to increase discharge and turn
Piston rod counter-clockwise to decrease discharge.
4. Adjusting scale is shown below.
Lock nut

Connecting rod

Reference position Reference position Reference position


1.0mℓ 2.5mℓ 5.5mℓ
0.8mℓ 2.0mℓ 4.5mℓ
0.6mℓ 1.5mℓ 3.5mℓ
0.4mℓ 2.5mℓ
0.2mℓ

[Oil volume adjustment knob]

Automatic intermittent piston pump


MMX-II
Highly reliable pump with a long history of service. Discontinued
Now Discontinued. product

* Refer to MMXL-III for replacement

Directions for use Specifications


Oil viscosity varies with oil temperature. Be sure to use oil
ƒƒ
within the working viscosity range. Refer to the viscosity Discharge 1.5 - 2.5cc/stroke
table. (P.237) volume 2.5 - 5.5cc/stroke
Pump
Do not use any oil containing special additives, water
ƒƒ Discharge
soluble oil, or solvent. 0.4MPa
pressure
Periodically check the oil in the reservoir for impurities.
ƒƒ
Replace with fresh oil immediately, if necessary. Be sure to Motor Working voltage/ AC100Vφ1/0.23A AC200Vφ3/0.11A (50Hz)
clean the reservoir before oil adding new oil. (Capable of Working current AC100Vφ1/0.23A AC200Vφ3/0.10A (60Hz)
Make sure that proper voltage is applied.
ƒƒ coping with
a different 5W Direction of rotation:
Do not over tighten the discharge joint. Refer to the tight-
ƒƒ Output
voltage) CW Induction generator E-class
ening torque table. (P.251)
Do not press the discharge volume adjusting knob down
ƒƒ Anomaly Oil level Contact type: NO
by force. detection switch Contact capacity 0.5A,AC DC200V/30W Smaller one
Adjust discharge volume only when the piston is fully
ƒƒ
relaxed (The knob is at the lowest position.). Operation rate Continuous
Replace the suction filter at least once a year.
ƒƒ Working vis- 32 - 1300cSt
Do not remove the oil fill strainer in order to keep the pump
ƒƒ cosity range
clear of foreign matter.
Check the direction of motor rotation. Change U and W Reservoir
ƒƒ 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
of the three-phase connection to change the direction of capacity
rotation. Weight 3kg (1.8ℓ plastic reservoirs)
Do not place the pump sideways or upside down.
ƒƒ
2μF condenser is built into the terminal box at 100V
Others motor

Replacement Hydraulic circuit


motor drawing

Model Working voltage


N-02 AC100Vφ1 5W
N-10 AC200Vφ3 5W
N-08 AC200Vφ1 5W

137
Discharge Volume Adjustment

1. Loosen lock-nut by turning it counter-clockwise.


Decrease Increase 2. After loosening lock-nut, turn and adjust the connecting rod
to the desired discharge volume and tighten lock-nut.
3. Turn clockwise to increase discharge and turn
Piston rod counter-clockwise to decrease discharge.
4. Adjusting scale is shown below.
Lock nut

Connecting rod

Reference position Reference position Reference position


1.0mℓ 2.5mℓ 5.5mℓ
0.8mℓ 2.0mℓ 4.5mℓ
0.6mℓ 1.5mℓ 3.5mℓ
0.4mℓ 2.5mℓ
0.2mℓ

[Oil volume adjustment knob]

Automatic intermittent piston pump


MMX-II
Highly reliable pump with a long history of service. Discontinued
Now Discontinued. product

* Refer to MMXL-III for replacement

Directions for use Specifications


Oil viscosity varies with oil temperature. Be sure to use oil
ƒƒ
within the working viscosity range. Refer to the viscosity Discharge 1.5 - 2.5cc/stroke
table. (P.237) volume 2.5 - 5.5cc/stroke
Pump
Do not use any oil containing special additives, water
ƒƒ Discharge
soluble oil, or solvent. 0.4MPa
pressure
Periodically check the oil in the reservoir for impurities.
ƒƒ
Replace with fresh oil immediately, if necessary. Be sure to Motor Working voltage/ AC100Vφ1/0.23A AC200Vφ3/0.11A (50Hz)
clean the reservoir before oil adding new oil. (Capable of Working current AC100Vφ1/0.23A AC200Vφ3/0.10A (60Hz)
Make sure that proper voltage is applied.
ƒƒ coping with
a different 5W Direction of rotation:
Do not over tighten the discharge joint. Refer to the tight-
ƒƒ Output
voltage) CW Induction generator E-class
ening torque table. (P.251)
Do not press the discharge volume adjusting knob down
ƒƒ Anomaly Oil level Contact type: NO
by force. detection switch Contact capacity 0.5A,AC DC200V/30W Smaller one
Adjust discharge volume only when the piston is fully
ƒƒ
relaxed (The knob is at the lowest position.). Operation rate Continuous
Replace the suction filter at least once a year.
ƒƒ Working vis- 32 - 1300cSt
Do not remove the oil fill strainer in order to keep the pump
ƒƒ cosity range
clear of foreign matter.
Check the direction of motor rotation. Change U and W Reservoir
ƒƒ 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
of the three-phase connection to change the direction of capacity
rotation. Weight 3kg (1.8ℓ plastic reservoirs)
Do not place the pump sideways or upside down.
ƒƒ
2μF condenser is built into the terminal box at 100V
Others motor

Replacement Hydraulic circuit


motor drawing

Model Working voltage


N-02 AC100Vφ1 5W
N-10 AC200Vφ3 5W
N-08 AC200Vφ1 5W

137
Dimensional drawing

18
205
166 39
72.5 72.5

Motor Terminal box

chines with intermittent delivery


compact system for small ma-
(SLR) Single Line Resistance
32

Discharge port
M8×1
(φ4 tubing) Direction of rotation

124
Manual feeding button

Oil fill cap


Part Number 529409

Installation hole 3-φ6.5


28

Strainer for filling oil

240
Wire pull-out opening
Part Number 521037
143

Suction filter set SF-13

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

Discharge Volume Adjustment Wiring diagram

1. Loosen lock-nut by turning it counter-clockwise.


Oil level switch OL OL
Decrease Increase
2. After loosening lock-nut, turn and adjust the
Motor U V W
Piston rod connecting rod to the desired discharge volume
and tighten lock-nut. Power input V V W
Lock nut 3. Turn clockwise to increase discharge and turn Oil level switch OL OL
connection output
counter-clockwise to decrease discharge.
4. Adjusting scale is shown below.
Three phase Single phase
power supply power supply

U V W U V W
Connecting
C
rod
2μF
Reference position Reference position
5.5mℓ 2.5mℓ
4.5mℓ 2.0mℓ Power input Power input
[Oil volume adjustment knob] 3.5mℓ 1.5mℓ 200 VAC φ3 100 VAC φ1
2.5mℓ

138
Automatic intermittent
piston pump
MLZ

Compact version of MMXL-III. Ideal for small


machines with limited installation space.

[CE]

Model Reference Specifications

MLZ CE Discharge
volume 1.5-2.5mℓ/stroke
Pump
Discharge 0.3MPa
pressure
Interval (50Hz/60Hz) Oil level switch
A 6min/4min48sec Blank Without Voltage/ AC100Vφ1/50mA, AC200Vφ1/25mA (50Hz)
Motor current AC100Vφ1/42mA, AC200Vφ1/18mA (60Hz)
B 15min/12min L With
C 30min/24min Voltage
Output 3W Synchronous
D 60min/48min 1 AC100V φ1 Emergency Oil level Contact type A contact (NO) ON at low level
E 120min/96min 2 AC200V φ1 detection switch Contact capacity 0.5A, AC DC200V/30W smaller
Operation Continuous
rating
Working vis-
Model cosity range 30-1300mm2/s

Reservoir 0.8ℓ
Model Part Number Model Part Number capacity
MLZ-CE-A-1 367201 MLZ-CE-C-2 367208 Weight 1.2kg
MLZ-CE-A-1L 367216 MLZ-CE-C-2L 367223 Protection IP54 (CE Approved type)
MLZ-CE-A-2 367206 MLZ-CE-D-1 367204 class
MLZ-CE-A-2L 367221 MLZ-CE-D-1L 367219
MLZ-CE-B-1 367202 MLZ-CE-D-2 367209
MLZ-CE-B-1L 367217 MLZ-CE-D-2L 367224 Directions for use
MLZ-CE-B-2 367207 MLZ-CE-E-1 367205
MLZ-CE-B-2L 367222 MLZ-CE-E-1L 367220 Oil viscosity varies with oil temperature. Be sure to use oil within the
ƒƒ
MLZ-CE-C-1 367203 MLZ-CE-E-2 367210 working viscosity range. Refer to the viscosity table. (P.237)
Do not use any oil containing special additives, water soluble oil, or
ƒƒ
MLZ-CE-C-1L 367218 MLZ-CE-E-2L 367225 solvent.
Periodically check the oil in the reservoir for impurities. Replace with
ƒƒ
fresh oil immediately, if necessary. Be sure to clean the reservoir
before oil adding new oil.
Make sure that proper voltage is applied.
ƒƒ
Do not over tighten the discharge joint. Refer to the tightening torque
ƒƒ
table. (P.251)
Do not press the discharge volume adjusting knob down by force.
ƒƒ
Adjust discharge volume only when the piston is fully relaxed
ƒƒ
(The knob is at the lowest position.).
Replace the suction filter at least once a year. Do not remove the oil fill
ƒƒ
strainer in order to keep the pump clear of foreign matter.
* Should the pump malfunction, contact LUBE for consultation.

Related parts

Flow unit PJ junction Tubing Pressure gauge Filter FX1 Filter FY20 Pressure switch Compression parts
: P.149 : P.164 : P.203 : P.184 : P.181 : P.181 : P.185 : P.201

Adapters Reservoir
: P.207 : P.168

133
Replacement Motor Model Dimensional drawing

Interval 6min 15min 30min 60min 120min


Motor RPM (50Hz) 10 4 2 1 1/2
Model M-B1 M-C1 M-D1 M-E1 M-F1
12.5
Replace- 100V Part 521194 521193 520062 520061 520060 125
ment Number 35 65 Ground terminal (M3)
Motor Model M-B2 M-C2 M-D2 M-E2 M-F2 Ground mark

chines with intermittent delivery


compact system for small ma-
(SLR) Single Line Resistance
Model 200V Part
521196 521195 520067 520066 520065
Number

41

47
89.5
Discharge port
M8×1
Replacement Motor Model (φ4Tubing) Wiring port
(G1/2)

Oil fill cap


Part Number Instant feed button
529432

Installation hole
3 - φ6.5
Packing

17
190.5
126
Suction filter set
Part Number 489007
[CE]

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

Discharge Volume Adjustment Wiring diagram

1. Loosen lock-nut by turning it counter-clockwise.


M
Decrease Increase 2. After loosening lock-nut, turn and adjust the connecting rod
to the desired discharge volume and tighten lock-nut. U V OL OL
Piston rod 3. Turn clockwise to increase discharge and turn
counter-clockwise to decrease discharge.
4. Adjusting scale is shown below.
Lock nut
Power input Contact output
Connecting rod [Standard]

M E
Reference position
2.5mℓ
2.0mℓ
1.5mℓ
U V OL OL
0

[Oil volume adjustment knob]


Power input Contact output
[CE]

134
Electric Pump for LHL
P-102/107/202/207
Small, low cost pump, exclusively for our LHL
original cartridge grease.

[P-107F-BK]

Model Reference Specifications


Feed button Power DC24V
With F2(5MPa)
Power Consumption 24W
With F(8MPa)
Black Without
Discharging pressure 5MPa/8MPa

Color
Discharging time No restriction
(BK) Black Minimum interval time 10 seconds

P- 0
(B) Blue Wiring method Terminal connection
(G) Green Manual override switch Yes (Optional)
Cartridge
2 200cc Grease level switch Yes
7 700cc Cover Non combustible plastic (UL94-V0)
Discharging pressure NEMA rating IP54
1 5MPa CE approval Yes
2 8MPa Pump air bleeding valve Yes
Weight P-102:1.2kg, 107:1.6kg, 202:1.2kg,
207:1.6kg

Model Directions for use


Use LUBE original LHL cartridge only.
ƒƒ
Model Part Number Model Part Number When the cartridge is changed, take care that foreign
ƒƒ
P-102(BK) 101002 P-202(BK) 101032 particles are not getting inside.
P-102(B) 101006 P-202(B) 101036 Do not discharge continuously.
ƒƒ
After changing the cartridge, bleed the air inside the
ƒƒ
P-102(G) 101008 P-202(G) 101038 pump by opening the air bleeding valve.
P-102F2(BK) 101082 P-207(BK) 101033
P-102F2(B) 101086 P-207(B) 101037
P-102F2(G) 101088 P-207(G) 101039
P-107(BK) 101003 P-202F(BK) 101042
Hydraulic circuit diagram
P-107(B) 101007 P-202F(B) 101046
P-107(G) 101009 P-202F(G) 101048
P-107F2(BK) 101083 P-207F(BK) 101043
P-107F2(B) 101087 P-207F(B) 101047
Cartridge grease
P-107F2(G) 101089 P-207F(G) 101049

Air bleeding valve Discharge port

Related parts

MU valve MUJ junction MDP valve GPL Pressure Switch Pressure gauge Main tubing Adapter assemblies LHL-X100
: P.57 : P.58 : P.59 : P.66 : P.95 : P.203 : P.217 : P.90

37
Dimensional drawing

Sticker

Small-Medium Machines
Injector (PDI) System for
Positive Displacement
Installation hole 3-φ7
LHL
245

Sticker
Operation Lump

Specifications
Sticker
Terminal
100

Cover fixing screw

97 8
7.5

45
20 21
122
204

Air bleeding plug

Discharge port Rc1/8


63

38

Wiring diagram P-107 Pump motion control flowchart

Pump stopping
signal output
COM Output
Level switch
output P-Pump Motion Control Flowchart Turn on the power

Is there grease Yes Is there pump Yes


Change the grease cartridge
level signal? stopping signal?
GND(–)
Input
No No
DC24V(+)
Is there pump Yes
stopping signal? Pump trouble
Ground
No
Without feed button
Start the pump No

With pump stopping signal


Stop Pump pressurisation Observing pump Is there grease Yes Is there pump Yes
Pump stop Signal trouble pressurising time stopping signal? Change the grease cartridge
level signal?
Signal
COM Output No
Observe the pump
working time Without pump stopping signal
Manual Level Yes
Output Is there pump
Switch Level Switch stopping signal? Turn off the pump, and take interval time
Switch Manual
Switch
No
GND Pump observing time depends on size of the system.
Input Pump pressurising time depends on size of the system. Pump trouble
DC24V

M3×0.5
With feed button

38
Dual-function motorized pump
EGM-T
Designed to operate both PDI and series progressive
systems by use of its built-in solenoid valve.

[EGM-10T-4-4C] [EGM-10T-4-7C]

Model Reference Model

Model Part Number


EGM 10T 4 C Cartridge type EGM-10T-4-4C 103834
C Cartridge type EGM-10T-4-7C 103835
Cartridge
4 400mℓ
7 700mℓ Specifications

Discharge volume 10mℓ/min


Pump Discharge 10MPa (safety valve
Wiring diagram pressure set pressure)
Motor 20W/0.8A
PDI Network wiring Progressive Network wiring Power Pressure relief 26W/1.1A
Solenoid (Black) (White)
Motor DC24V solenoid
(White) (Black)
M Total 46W/1.9A
(Thermal
protector)
Pressurization Max. ON time: 7.5 min. (PDI Port)
Power distribution Max.25% (20°C)
rate
DC24V Input DC24V Input Working Viscosity Cartridge Grease No.000,00,0,1
Recommended MP0, FS2, MT1
grease
Cartridge size 200mℓ, 400mℓ, 700mℓ
Weight 1.78kg (2C), 1.83kg (4C), 1.8kg (7C)
Hydraulic circuit drawing Pressure relief Built-in solenoid

Directions for use


Cartridge grease
Relief valve
Use recommended grease only.
ƒƒ
Solenoid Never use greases containing molybdenum disulfide.
ƒƒ
Use lithium grease. (Contact LUBE for consultation when non-lithium
ƒƒ
PDI discharge port Rc 1/8 greases must be used.)
M
Do not use any greases containing substances that attack brass or rubber.
ƒƒ
Avoid continuous operation.
ƒƒ
Series progressive system port Rc 1/8
Air bleeding valve Normal operation or when filling grease into the (PDI) main tubing, please re-
ƒƒ
member to adhere to the 3 to 1 ratio for off time to running time not exceed-
ing 7.5 minutes. Failure to follow this could result in permanent damage to
the solenoid not allowing the pump to ever build pressure.
When filling grease into the (progressive) main tubing there is no lim-
ƒƒ
itation of time which will damage the pump. Be cautious not to over
Related parts lubricate your bearing surfaces.

MG2 metering valve MG2C metering valve JVPA Junction MG2I metering valve MGLA metering valve GPL pressure switch Pressure gauge Main tubing
: P.61 : P.61 : P.62 : P.63 : P.65 : P.66 : P.95 : P.203

Adapter assemblies LUBE original grease Controller Power box SP series progressive valve AP series progressive valve
: P.217 : P.89 : P.93 : P.93 : P.77 : P.77

81
Dimensional drawing

104 (Sticker)

4-φ9
Installation
25

4-φ9

251
228

hole

25
Installation
hole

25
109

Air bleeding

25
109
valve (Sticker) Air bleeding

59
valve

59
176
127 16
141 104
Series progressive valve port PDI Discharge port 179
Rc1/8 Rc1/8 Series progressive valve port PDI Discharge port
Rc1/8 Rc1/8

Parts for connecting to the Parts for connecting to the


discharge port discharge port

S81-SC S81-SC

[EGM-10T-4-2C] [EGM-10T-4-7C]

Parts for connecting to the


discharge port

S81-SC

System for Small-Medium Machine


Series Progressive Metering Valve
Compatible with Both PDI and
400

25

4-φ9
Installation
hole
25
109

Air bleeding valve


59

104 13
(127) 176

Series progressive valve port Rc1/8 PDI Discharge port Rc1/8

[EGM-10T-4-4C]

82
Dual-function motorized pump
EGME-T
Operates both PDI and series progressive systems by use of its
built-in-solinoid valve. EGME pumps utilize an internal solenoid
protection circuit which eliminates the 7.5 minute maximum
running time of other EGM pumps.
[EGME-10T-4-2C]

Model Reference Model

EGME 10T 4 C Cartridge type


Model Part Number
EGME-10T-4-2C 103902
C Cartridge type
EGME-10T-4-7C 103911
Cartridge
2 200mℓ
4 400mℓ
7 700mℓ Specifications

Discharge volume 10mℓ/min


Pump Discharge pressure 10MPa (safety
Wiring diagram valve set pressure)
Motor 20W/0.8A
DC24V Input Power Pressure relief solenoid 10W/0.4A
Motor Solenoid DC24V
(+) - (+) Total 30W/1.2A
Working Viscosity Cartridge Grease No.000,00,0,1
Recommended MP0, FS2, MT1
grease
1 2 3 4
Terminal box Cartridge size 200mℓ, 400mℓ, 700mℓ
Weight 1.8kg (4C), 2.8kg (7C)
Pressure relief Built-in solenoid
Hydraulic circuit drawing

Directions for use


Use recommended grease only.
ƒƒ
Cartridge grease Never use greases containing molybdenum disulfide.
ƒƒ
Relief valve Use lithium grease. (Contact LUBE for consultation when non-lithium
ƒƒ
greases must be used.)
Solenoid
Do not use any greases containing substances that attack brass
ƒƒ
and rubber.
PDI discharge port Rc 1/8
Avoid continuous operation.
ƒƒ
M

Series progressive system port Rc 1/8


Air bleeding valve

Related parts

MG2 metering valve MG2C metering valve JVPA Junction MG2I metering valve MGLA metering valve GPL pressure switch Pressure gauge Main tubing
: P.61 : P.61 : P.62 : P.63 : P.65 : P.66 : P.95 : P.203

Adapter assemblies LUBE original grease Controller Power box SP series progressive valve AP series progressive valve
: P.217 : P.89 : P.93 : P.93 : P.77 : P.77

83
Dimensional drawing

(Sticker)

4-φ9 Installation hole

4-φ9 Installation hole

25 25 25
228

25 25 25
228
27
59
70

Air bleeding
valve

27
87

59
70
127 104 13 Air bleeding
213
Wiring port 87 valve
127 104 13
φ21 213
Series progressive valve port Rc1/8 PDI Discharge port Rc1/8 Wiring port
φ21
Series progressive valve port Rc1/8 PDI Discharge port Rc1/8

Parts for connecting to the Parts for connecting to the


discharge port discharge port

S81-SC S81-SC

[EGME-10T-4-2C] [EGME-10T-4-7C]

System for Small-Medium Machine


Series Progressive Metering Valve
Compatible with Both PDI and
4-φ9 Installation hole
400
25
25
25
27

59
70

Air bleeding valve


87
104 13
127
213

Wiring port
Series progressive valve port Rc1/8 PDI Discharge port Rc1/8
φ21

Parts for connecting to the


discharge port

S81-SC

[EGME-10T-4-4C]

84
Positive Displacement Injector Electric Pump with solenoid protection
PDI plus Progressive Twin Electric Pump (for "T" series pumps)
EGME II
Small, low cost pump for use with our original cartridge
grease. EGME-II pumps have a built in solenoid protection
circuit which eliminates the 7.5 minute maximum running time
of other EGM pumps.
[EGME II]

Model Reference Model


Feed button
Model Part Number
With FB EGMEII-10S-4-7CL 103922
Without Without EGMEII-10S-4-7CLFB 103923
* If it is T-type, it hasn’t got EGMEII-10T-4-7CL 103932
manual override switch.
EGMEII-8S-4-7CLFB-LHL 103921
EGME 4 7CL (LHL) EGMEII-8S-4-7CL-LHL 103920
*2: Only if it’s 8MPa.

S Positive Displacement Injector(PDI) System


T Positive Displacement Injector(PDI) System and Progressive System
Specifications
*If it’s 8MPa, it must be only Positive Displacement Injector(PDI) System Power DC24V
8 8MPa (Only for LHL System) Power Consumption 28.8W
10 10MPa Discharge pressure 8MPa (Only for LHL System)
10MPa
Maximum discharging No restriction
time
Minimum interval time 10 seconds
Hydraulic circuit diagram
Wiring method Terminal connection
T-type Manual override switch Yes (Optional: Only PDI system) *
Grease level switch Yes
Cartridge grease
Solenoid cover Non combustible plastic (UL94-V0)
Relief Valve
Protection class IP54
Solenoid Valve
CE approval Yes
Main tube discharging port (PDI)
Rc:1/8
Pump air bleeding valve Yes
M Weight 2.0kg (With manual operating
Pressure progressive discharging port Air bleeding valve switch: 2.1kg)
Rc:1/8
* Although the Manual Override Switch provides a dry contact to activate the pump, its capacity
is not sufficient to sustain the power required to operate the pump. Therefore, the power needs
S-type to be provided directly to the pump from the machine control panel. See wiring diagram P.42.

Cartridge grease

Relief Valve
Directions for use
Solenoid Valve
Use recommended grease only.
ƒƒ
Never use greases containing molybdenum disulfide.
ƒƒ
Main tube discharging port (PDI)
Use lithium grease. (Contact LUBE for consultation when
ƒƒ
Rc:1/8 non-lithium greases must be used.)
Air bleeding valve
Do not use any greases containing substances that attack
ƒƒ
brass or rubber.
When the cartridge is changed, take care that foreign particles
ƒƒ
are not introduced to pump.
Do not discharge continuously.
ƒƒ
After changing the cartridge, bleed the air inside the pump by
ƒƒ
opening the air bleeding valve.
Related parts

MG2 metering valve MG2C metering JVPA Junction MG2I metering valve MGLA metering GPL pressure switch Pressure gauge Main tubing
: P.61 valve : P.61 : P.62 : P.63 valve : P.65 : P.66 : P.95 : P.203

Adapter assemblies Hand grease gun LUBE original grease LHL-X100 Controller Power box
: P.217 : P.96 : P.89 : P.90 : P.93 : P.93

41
Dimensional drawing
[EGME II-10S-4-7CLFB]

Small-Medium Machines
Injector (PDI) System for
Positive Displacement
241
Installation Hole 4-φ9

25
25
25
27
Air bleeding valve

22
80 22 104 13 3

126 218
141 234

Disable Main tube discharging port (PDI) Rc:1/8

[EGME II-10T-4-7CL]

241
Installation Hole 4-φ9
25
25
25
27

Air bleeding valve


22

80 22 104 13 3

126 218
141 234

Progressive discharging port Rc:1/8 Disable Main tube discharging port (PDI) Rc:1/8

Wiring diagram Grease level switch

EGME II-S FB
Grease level switch
7 8

Manual Override Switch


GL
GL Output
FB

1 2 3 4 5 6 1 2 3 4 5 6

24VDC Level Switch 24VDC Level Switch


Input Output Input Output

Without feed button With feed button

GL
EGME II-T M
SV

1 2 3 4 5 6

24VDC Level Switch


Input Output

Without feed button

42
Positive Displacement Injector
(PDI) System
EGM

Motor driven piston pump for cartridge grease


[EGM-10S-4-4C] [EGM-10S-4-7C]

Model Reference Specifications

EGM 10S 4 C Type of reservoir


Pump
Discharge volume
Discharge pressure
10mℓ/min
10MPa
C Cartridge type Motor 20W/0.8A
Cartridge Pressure relief
Power DC24V 26W/1.1A
2 200mℓ solenoid
4 400mℓ Total 46W/1.9A
7 700mℓ Maximum run time 7.5 min.
Power distribution rate Max.25% (20°C)
Model
Working consistency NLGI No.000,00,0,1

Model Part Number Recommended grease MP0, FS2, MT1

EGM-10S-4-2C 103809 Cartridge size 200mℓ , 400mℓ , 700mℓ


EGM-10S-4-4C 103810 Weight 1.8kg (4C) , 2.8kg (7C)
EGM-10S-4-7C 103811 Pressure relief Built-in solenoid

Directions for use Wiring diagram


Motor
Use recommended grease only.
ƒƒ (White) (Black)
M
Never use greases containing molybdenum disulfide.
ƒƒ
Use lithium greases. (Contact LUBE for consultation when non-lithium
ƒƒ Solenoid
greases must be used.) (White) (Black)
Do not use any greases which may contain substances that attack
ƒƒ (Thermal
brass or rubber. protector)

When refilling, take care not let foreign matter in the grease.
ƒƒ
Avoid continuous operation.
ƒƒ
For normal operation or when filling grease into the main tubing,
ƒƒ DC24V Input
please remember to adhere to the 3 to 1 ratio for off time to running
time not exceeding 7.5 minutes. Failure to follow this could result in
permanent damage to the solenoid not allowing the pump to ever
build pressure.
Hydraulic circuit drawing

Cartridge
Relief valve
Solenoid

Discharge port Rc1/8


Air bleeding valve
Related parts

MG2 metering valve


: P.61 MG2C metering valve JVPA Junction MG2I metering valve MGLA metering valve GPL pressure switch Pressure gauge Main tubing
: P.61 : P.62 : P.63 : P.65 : P.66 : P.95 : P.203

Adapter assemblies LUBE original grease LHL-X100 Controller Power box


: P.217 : P.89 : P.90 : P.93 : P.93

51
Dimensional drawing
Parts for connecting to the
discharge port

S81-SC

400

25
Installation hole 4-φ9

25
109

Small-Medium Machines
Injector (PDI) System for
Positive Displacement
Air bleeding valve

59
104 13
(127) 176
Discharge port Rc1/8

[EGM-10S-4-4C]

(Sticker)
104

(Sticker)

4-φ9
Installation 4-φ9
25

251

25
222

hole Installation
hole
25

25
109

109

Air bleeding (Sticker) Air bleeding


valve
valve
59

59

176
127 141 104 16
Discharge port Rc1/8 179
Motor wiring Discharge port Rc1/8
(L=300)
Solenoid wiring
(L=230)

Parts for connecting to the Parts for connecting to the


discharge port discharge port

[EGM-10S-4-2C] S81-SC [EGM-10S-4-7C] S81-SC

52
Positive Displacement Injector
(PDI) System
EGH

Compact, low-cost manually operated pump

Model Reference Reservoir type Cartridge type Cartridge type


[EGH-3P] [EGH-2C] [EGH-4C]

EGH
Specifications
Type of reservoir (effective capacity)
3P Reservoir type (260mℓ)
2C Cartridge type (200mℓ) EGH-3P
4C Cartridge type (400mℓ) Discharge volume 1mℓ/stroke
Pump
Discharge pressure 10MPa (safety valve set pressure)

Model Working consistency NLGI No.000, 00, 0, 1 (lithium grease)


Recommended grease MP0, FS2, MT1
Model Part Number Reservoir Size 260mℓ
EGH-2C 103780
Weight 1.4kg
EGH-3P 103783
Pressure relief Manual pressure relief lever
EGH-4C 103782
EGH-2C / EGH-4C
Discharge volume 1mℓ/stroke
Pump Max Discharge
Directions for use pressure 10MPa (safety valve set pressure)
Cartridge grease No.000, 00, 0, 1
Use recommended cartridge grease only.
ƒƒ Working consistency (lithium grease)
Never use greases containing molybdenum disulfide.
ƒƒ
Use lithium greases. (Contact LUBE for consultation when non-lithi-
ƒƒ Recommended grease MP0, FS2, MT1
um greases must be used.) Cartridge size 200mℓ, 400mℓ Cartridge
Do not use any greases containing substances that attack brass or
ƒƒ
rubber. Weight 1.4kg
When refilling reservoir or replacing cartridge, take care not to let
ƒƒ
foreign matter into the grease or pump. Pressure relief Manual pressure relief lever
After refilling reservoir or replacing cartridge, bleed air from the
ƒƒ
pump by opening the air bleeding valve.
Always return operating lever to locked position to relieve system
ƒƒ
pressure. Hydraulic circuit drawing

Reservior
Relief valve Refilling port

Manual depressurizing
valve
Discharge Port
Air bleeding valve

Related parts

MG2 metering valve MG2C metering valve JVPA Junction MG2I metering valve Pressure gauge Main tubing Adapter assemblies Pneumatic pump for pail
: P.61 : P.61 : P.62 : P.63 : P.95 : P.203 : P.217 : P.96

Hand grease gun LUBE original grease


: P.96 : P.89

53
Dimensional drawing (310)
(9.5°)

)

7.
(4

Sticker
336

253

3-φ9 Installation hole

Filling port

Handle lock
75

Small-Medium Machines
Injector (PDI) System for
Positive Displacement
Air bleeding
valve

Parts for connecting to the 9


70
discharge port
(150)

Discharge port (Rc1/8)


Reservoir type
[EGH-3P] S81-SC

(9.5 ) (310)

(9.5°)
(310)

.5 )
(47
)
.5°
Sticker Sticker (47
394
(336)

3-φ9 Installation hole


3-φ9 Installation hole
75

75

Handle lock Air Air


bleeding bleeding
valve Handle lock
valve
70 (150) 70 (150)
Discharge port (Rc1/8) Discharge port (Rc1/8)

Parts for connecting to the Parts for connecting to the


discharge port discharge port

Cartridge type Cartridge type


[EGH-2C] S81-SC [EGH-4C] S81-SC

54
Automatic intermittent gear pump
AMZ- III [CE]
Lightweight and compact pump unit without controller.
Conforms to European Safety Standard. Oil level and
pressure switches are standard equipment.

Model Reference

AMZ [1.8ℓ] [3ℓ]


Reservoir Mounting Poition
Voltage
1 AC100Vφ1
Blank Resin Specifications
F Foot Mount
2 AC200Vφ1
B Wall Mount
23 AC230Vφ1 Pump Discharge 90mℓ/min (50Hz), 110mℓ/min (60Hz)
*Metal reservoir only volume
Reservoir capacity Discharge 1.5MPa/217.5psi
pressure (safety valve set pressure)
Blank 1.8ℓResin reservoirs
3 3ℓResin reservoirs Motor Voltage / AC100Vφ1/1.5A, AC200Vφ1/0.8A (50Hz)
current AC100Vφ1/1.3A, AC200Vφ1/0.7A (60Hz)
30 3ℓMetal reservoirs
Output 19W (50Hz), 18W (60Hz) Shading motor
40 4ℓMetal reservoirs
80 8ℓMetal reservoirs Emergency Oil level Contact type (NO) ON at low level
detection switch Contact capacity 0.5A, AC DC200V/30W smaller
*Pump is installed on the right
side, if a metal reservoir is Pressure Contact type (NO)
Model selected. switch Operating pressure: 1.3M ON
Reset pressure: 0.9MPa OFF
Model Part Number Contact capacity AC DC250V/2A
Operation Max. discharge time: 1 min.
AMZ-III -1 285017 Min.interval time: 3 min.
AMZ-III -1-3 285024 Working vis-
2
50-1300mm /S (50Hz)
AMZ-III -2 285016 cosity range
AMZ-III -2-3 285023 Reservoir 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
capacity
AMZ-III -23 285433
Weight 1.8ℓ: 2.7kg 3ℓ: 3.6kg
Low viscosity oil pump (On the page of AMZ-III) External fuse 100V/2.0A, 200V/1.0A
Part No. Voltage Tank Working vis­
No Model capacity cosity range * Should the pump malfunction, contact LUBE for consultation.

1 AMZ-3-100SL-18LP 285224 100V 1.8L 22 ~ 800mm2/S


2 AMZ-3-100SL-18LP 285426 200V 1.8L 22 ~ 800mm2/S

Directions for use


This pump unit requires a separate control circuit to operate.
ƒƒ Periodically check the oil in the reservoir for impurities.
ƒƒ
Do not remove the oil fill strainer in order to keep the pump
ƒƒ Replace it, if necessary, with fresh oil immediately.
clear of foregn matter. Be sure to clean the reservoir before replacing oil.
Replace the suction filter at least once a year.
ƒƒ Make sure that proper voltage is applied.
ƒƒ
Oil viscosity varies with oil temperature. Be sure to use oil within
ƒƒ Do not over tighten the discharge joint.
ƒƒ
the working viscosity range. Refer to the viscosity table. (P.237) Refer to the torque table. (P. 251)
ƒƒ
Do not use any special additive-contained oil, water soluble oil,
ƒƒ ƒƒLow-oil viscosity versions are available. Contact us for information.
or solvent.

Related parts

For MO2(C) Valve For MO Valve For MOS Valve

MO2(C) Metering JVPA Junction MO Metering valve: PV Junction MOS Metering valve PVS Junction MB Metering valve MIX-S Metering valve
valve: P.115 : P.116 P.117 : P.118 : P.119 : P.121 : P.123 : P.127

F-3D Filter Pressure gauge Tubing Compression parts Adapters Reservoirs Flexible pipe nozzle with
: P.181 : P.186 : P.203 : P.201 : P.207 : P.171 metering valve: P.195

103
Dimensional drawing

Large Machines
Injector (PDI) System for
Positive Displacement
270
35

166
17

Discharge port

63
Discharge port M10×1
M10×1

135
54
Oil fill cap
120

Part Number
529409

Oil fill cap


Wiring port
Wiring port Part Number
529409
234
147

Part Number
521037 2×M6
2×M6 Installation hole
Installation hole
Strainer
Part Number
521037

(262)
(256)

177
171

Suction filter set Suction filter set


Part Number 489011 Part Number 489011

Parts for connecting to the discharge port


[1.8ℓ] [3ℓ]

CB-6 CS-6 TI-6

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

Hydraulic circuit drawing Wiring diagram

PRESS. SW
P
EMG. OUT
C
OIL LEVEL. SW
RV
O
POWER Y
M
X
E Thermal protector

104
Automatic small discharge
volume gear pump
AMS
Motor driven gear pump for continuous micro-volume lubrication
used with a resistance type centralized lubrication equipment

Model Reference Specifications

AMS AMS-1, AMS-3


AMS-1: 1.25mℓ/min (50Hz), 1.5mℓ/min (60Hz)
Discharge AMS-3 : 2.5mℓ/min (50Hz), 3mℓ/min (60Hz)
Pump volume
Discharge volume (50Hz / 60Hz) Reservoir Mounting Position AMS-6 : 5mℓ/min (50Hz), 6mℓ/min (60Hz)
1 1.25/1.5mℓ/min Blank Resin reservoirs Discharge 0.8MPa (safety valve setting)
3 2.5/3mℓ/min F Foot Mount pressure
6 5/6mℓ/min B Wall Mount AC100Vφ1/50mA AC200Vφ1/25mA
(50Hz)
15 15/18mℓ/min *Metal reservoir only
Motor AC100Vφ1/42mA AC200Vφ1/18mA
Pump Position (Other Power (60Hz)
Voltage L Pump position-Left voltages AC100Vφ1/25mA (50Hz)
available.) AC200Vφ1/18mA (60Hz)
1 AC100V φ1 R Pump Position-Right
2 AC200V φ1 *Except 1.8ℓ Resin reservoir Output 3W Synchronous Motor
Reservoir capacity
Contact type A contact (NO) ON at
Oil level switch Emergency Oil level low level
Blank Without Blank 1.8ℓ Resin reservoirs detection switch Contact capacity 0.5A,
L With 3 3ℓ Resin reservoirs AC DC200V/30W smaller
30 3ℓ Metal reservoirs Operation rate Continuous
40 4ℓ Metal reservoirs
80 8ℓ Metal reservoirs Working vis- 32-1300mm2/s
cosity range
Reservoir 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
capacity
Model
Weight 1.8kg

Model Part Number Model Part Number


AMS-1-1 102401 AMS-3-1 102405
Directions for use
AMS-1-1L 102403 AMS-3-1L 102407
AMS-1-2 102402 AMS-3-2 102406 Oil viscosity varies with oil temperature. Be sure to use oil within
ƒƒ
AMS-1-2L 102404 AMS-3-2L 102408 the working viscosity range. Refer to the viscosity table. (P.237)
Do not use any oil containing special additives, water soluble
ƒƒ
AMS-15-1 102416 AMS-6-1 102489 oil, or solvent.
AMS-15-1L 102418 AMS-6-1L 112094 Periodically check the oil in the reservoir for impurities. Replace
ƒƒ
AMS-15-2 102417 AMS-6-2 102490 with fresh oil immediately, if necessary. Be sure to clean the
reservoir before oil adding new oil.
AMS-15-2L 102419 AMS-6-2L 112095 Do not over tighten the discharge joint. Refer to the tightening
ƒƒ
* Should the pump malfunction, contact LUBE for consultation. torque table. (P.251)
Make sure that proper voltage and pressure are proper.
ƒƒ
Replace the suction filter at least once a year.
ƒƒ

Related parts

control unit PJ junction Tubing Pressure gauge Filter Filter Pressure switch Compression parts
: P.161 : P.164 : P.203 : P.184 FX1: P.181 FY20: P.181 : P.185 : P.201

Adapters Reservoir
: P.207 : P.174

153
Specifications Replacement Motor Model

AMS-15 Replacement
Pump Part Number Voltage Motor Model
Discharge 15mℓ/min (50Hz) 18mℓ/min
volume (60Hz) 521194 100V M-B1
Pump AMS-1
Discharge 521196 200V M-B2
0.8MPa (safety valve setting)
pressure 521194 100V M-B1
AC100Vφ1/0.25A (50Hz/60Hz) AMS-3
Motor Power 521196 200V M-B2
200Vφ1
(Other voltages 521210 100V M-A1
available.) 5.0W Accessory - Condesor AMS-6
Output 521328 200V M-A2
3.0μF
Gear Head Speed Reduction Ratio: 1/25
Working viscosity 32-1300mm2/s
range
Reservoir capacity 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
Weight 2.3kg

with continuous (recirculation) delivery


tem for small machines to lage machines
(SLR) Single Line Resistance compact sys-
Dimensional drawing 160
25

30
25
160

Discharge port
8 ×1)
(M 8×1)
30

120
Discharge φ4 Tubing
port (M8×1) Wiring port
Oil volume
(φ4 Tubing) adjusting screw
120

Oil volume
adjusting screw
Oil fill cap
Oil fill cap Part Number
Part Number 549005
549005 72.5 72.5

Installation hole 72.5 72.5


3-φ6.5
3-φ6.5
Wiring port
35
25

10

267
203
148

173

Suction filter
Part Number 500324
Suction filter
Part Number 500324
[AMS-1, 3] [AMS-15]

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

Hydraulic circuit drawing Wiring diagram

M
RV 1 2 3
U V OL OL
C
Option
M
OL SW Power input

Power input Contact output

[AMS-1, 3, 6] [AMS-15]

154
Automatic intermittent
gear pump
AMR-III DS
Capable of operating over a wide viscosity range.
Digital display gives on sight visual indication.
Interval can be a function of time or count.
[1.8ℓ Reservoir type] [3ℓReservoir type]

Model Reference Specifications

AMR DS Discharge 150mℓ/min (50Hz) 180mℓ/min (60Hz)


volume
Voltage Reservoir Mounting Poition Pump
Blank Resin Discharge 0.8MPa (safety valve set pressure)
1 AC100Vφ1 pressure
2 AC200Vφ1 F Foot Mount
B Wall Mount AC100Vφ1/0.83A, AC200Vφ1/0.41A (50Hz)
Power AC100Vφ1/0.64A, AC200Vφ1/0.33A (60Hz)
*Metal reservoir only Motor
Output 20W (50Hz/60Hz) Capacitor motor
Reservoir capacity
Blank 1.8ℓ Resin reservoirs Discharge time adjustable range: 1-99 seconds
(2.5-247.5mℓ) 50Hz, (3-297mℓ) 60Hz
3 3ℓ Resin reservoirs Timer Interval time adjustable range:
counter
30 3ℓ Metal reservoirs 1 to 9999 minutes
40 4ℓ Metal reservoirs 1 to 9999 counts
80 8ℓ Metal reservoirs Emergency Contact type A contact (NO)
*Pump is installed on the output Contact capacity AC250V 1.5A
right side, if a metal
reservoir is selected. Oil level Contact type A contact (NO)
Model
Controller Emergency switch ON at low level
detection Prerssure Contact type A contact (NO)
Model Part Number switch ON at low pressure
AMR-III DS-1 112141 INTERVAL display 'INT'
AMR-III DS-1-3 112143
DISCHARGE display 'DIS'
AMR-III DS-2 112142 Liquid
crystal When oil side decreases,
AMR-III DS-2-3 112144 display display 'OILLEVEL ERR'
ALARM When pressure is abnormal,
display 'PRESSURE ERR'
Working
Directions for use viscosity 68-1300mm2/s (50Hz)
range
Oil viscosity varies with oil temperature. Be sure to use oil within the
ƒƒ Reservoir 1.8ℓ, 3ℓ (plastic) 3ℓ, 4ℓ, 8ℓ (sheet metal)
working viscosity range. Refer to the viscosity table. (P.237) capacity
Do not use any oil containing special additives, water soluble oil, or
ƒƒ
solvent. Weight 1.8ℓ Reservoirs: 3.2kg, 3ℓ Reservoirs: 4kg
Periodically check the oil in the reservoir for impurities. Replace with
ƒƒ
fresh oil immediately, if necessary. Be sure to clean the reservoir * Should the pump malfunction, contact LUBE for consultation.
before oil adding new oil.
Do not over tighten the discharge joint. Refer to the tightening
ƒƒ
torque table. (P.251)
Make sure that proper voltage and pressure are proper.
ƒƒ
Replace the suction filter at least once a year.
ƒƒ
Do not remove the oil fill strainer in order to keep the pump clear of
ƒƒ
foreign matter.

Related parts

Flow unit PJ junction Tubing Pressure gauge Filter FX1 Filter FY20 Pressure switch Compression parts
: P.149 : P.164 : P.203 : P.184 : P.181 : P.181 : P.185 : P.201

Adapters
: P.207

141
Exterior features of the controller Hydraulic circuit drawing

LCD

RV

chines with intermittent delivery


compact system for small ma-
(SLR) Single Line Resistance
“RESET & FEED”
key
“UP” key
M
“DOWN” key “Enter” key

Operation panel of the controller

LCD shows the below: Wiring diagram


INTERVAL → INT
DISCHARGE → DIS
ALARM → Low oil level OILLEVEL ERR Power E Emergency Count in
Low pressure PRESSURE ERR output (Only count in model)

Dimensional drawing

275
190 234
170
89
88.5

143.5

Oil fill cap Oil fill cap


124

Part Number with Part Number


with 529409 P/S 529409
Discharge port P/S Discharge port
Rc1/8 Rc1/8

Pressure gauge installation port 167 Pressure gauge installation port


Rc1/8 Rc1/8

Installation
hole
Installation hole 2-φ9
2-φ6.5

Strainer Strainer
279
271

Part Number Part Number


521037 521037
174
172

Suction filter set Suction filter set


Part Number 489011 Part Number 489011

[1.8ℓ reservoir type] [3ℓ reservoir type]

Parts for connecting to the discharge port

or
CB-6 CS-6 SA6-20 EA6-22

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

142

You might also like