You are on page 1of 44

http://www.midasuser.

com

RC FOOTIING LIST

Ly
TYPE "A"
E
E.Q E.Q

X1

D
Cy Y1
E.Q

Cx
Lx

TYPE "B"
G.L
Y1
E.Q

X1
X1
D

Y1

FOOTING COLUMN REBAR


SOIL
NAME TYP. CAPA. REMARK
THK
THK. Lx Ly Cx C
Cy X1 Y1 X2 2
Y2

P12 P12
BASE TYPE A. C8(80)
B 350 1000 1000 200 2
200 @100 @100 200 H=1600

P12 P12
BASE TYPE B. C9(81)
B 350 1300 1300 200 2
200 @100 @100 200 H=1600

P12 P12
BASE TYPE C. C10(69)
B 500 1900 1900 200 2
200 @100 @100 200 H=1600

P12 P12
BASE TYPE D. C11(54)
B 500 1800 1800 300 2
200 @100 @100 200 H=1600

P12 P12
BASE TYPE E. C12(65)
B 400 1500 1500 200 3
300 @100 @100 200 H=1600

P12 P12
BASE TYPE F. C13(84)
B 350 1000 1000 300 2
200 @100 @100 200 H=1600

P12 P12
BASE TYPE G. C14(53)
B 300 1000 1000 200 2
200 @100 @100 200 H=1600

P12 P12
BASE TYPE H. C15(7)
B 500 1900 1900 200 2
200 @100 @100 200 H=1600

P12 P12
BASE TYPE I. C16(15)
B 350 1000 1000 300 2
200 @100 @100 200 H=1600

P12 P12
BASE TYPE J. C17(6)
B 350 1000 1000 200 2
200 @100 @100 200 H=1600
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE A. C8(80)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
1,000
(3) γc : 1.500
500 500
(4) γs : 1.150
(5) αcc : 0.850
(6) δ : 1.000

500
2. Material

1,000
(1) fck : 20.00MPa
Y1
(2) fyk : 500MPa

500
3. Section X1

(1) Foundation
Depth : 350mm
Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 200x200mm
1,600

4. Rebar
(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)
350

5. Foundation
(1) Foundation Size
Lx : 1.000m
Ly : 1.000m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 2 143 0.000 0.000 SERV :1.0D + (1.0LL)
1 Yes COMB. 2 143 0.000 0.000 SERV :1.0D + (1.0LL)
2 Yes COMB. 4 119 0.000 0.000 SERV :1.0D + (0.3LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 198 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 198 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 177 qs,top-right = 177
qs,bot-left = 177 qs,bot-right = 177
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE A. C8(80)

qs,max = 177 fe = 200


qs,max / fe = 0.884 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 248 qu,top-right = 248
qu,bot-left = 248 qu,bot-right = 248
qu,max = 248 qu,min = 248

8. Calculate Moment Effective Depth


(1) Direction X = 294mm (for MEdy )
(2) Direction Y = 282mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0109
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 279mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 156mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 367mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 18.93kNꞏm MRdy = 137kNꞏm
MEdy / MRdy = 0.138 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0119
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 268mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 162mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 382mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 18.93kNꞏm MRdx = 132kNꞏm
MEdx / MRdx = 0.144 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE A. C8(80)

11. Calculate Shear Effective Depth


(1) Direction X = 294mm (for VEdx )
(2) Direction Y = 282mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.825
ρl = min[ Asl /bw d, 0.02 ] = 0.00385
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 127kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 113kN
VRdx = VRd,c = 127kN
VEdx = 21.81kN
VEdx / VRdx = 0.172 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.842
ρl = min[ Asl /bw d, 0.02 ] = 0.00401
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 125kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 110kN
VRdy = VRd,c = 125kN
VEdy = 24.78kN
VEdy / VRdy = 0.199 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 800mm
β = 1.000
β NEd
νEd = = 1.075MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.344 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.833
ρl = min[ ρly ρlz , 0.02 ] = 0.00393
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.437 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.389 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.437 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 2,610mm
β = 1.000
βVEd,red
νEd = = 0.155MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.875 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE A. C8(80)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.777 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.875 MPa
νEd / νRd = 0.177 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 367mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 156mm² → O.K
sx = 100mm < sreq = 309mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 382mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 162mm² → O.K
sy = 100mm < sreq = 309mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE B. C9(81)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
1,300
(3) γc : 1.500
650 650
(4) γs : 1.150
(5) αcc : 0.850
(6) δ : 1.000

650
2. Material
(1) fck : 20.00MPa

1,300
(2) fyk : 500MPa Y1

650
3. Section
X1
(1) Foundation
Depth : 350mm
Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 200x200mm

4. Rebar
1,600

(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)

5. Foundation
350

(1) Foundation Size


Lx : 1.300m
Ly : 1.300m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 2 274 0.000 0.000 SERV :1.0D + (1.0LL)
1 Yes COMB. 2 274 0.000 0.000 SERV :1.0D + (1.0LL)
2 Yes COMB. 4 217 0.000 0.000 SERV :1.0D + (0.3LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 381 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 381 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 196 qs,top-right = 196
qs,bot-left = 196 qs,bot-right = 196
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE B. C9(81)

qs,max = 196 fe = 200


qs,max / fe = 0.980 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 276 qu,top-right = 276
qu,bot-left = 276 qu,bot-right = 276
qu,max = 276 qu,min = 276

8. Calculate Moment Effective Depth


(1) Direction X = 294mm (for MEdy )
(2) Direction Y = 282mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0232
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 279mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 330mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 367mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 40.02kNꞏm MRdy = 137kNꞏm
MEdy / MRdy = 0.291 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0252
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 268mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 344mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 382mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 40.02kNꞏm MRdx = 132kNꞏm
MEdx / MRdx = 0.304 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE B. C9(81)

11. Calculate Shear Effective Depth


(1) Direction X = 294mm (for VEdx )
(2) Direction Y = 282mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.825
ρl = min[ Asl /bw d, 0.02 ] = 0.00385
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 165kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 147kN
VRdx = VRd,c = 165kN
VEdx = 83.82kN
VEdx / VRdx = 0.507 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.842
ρl = min[ Asl /bw d, 0.02 ] = 0.00401
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 162kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 143kN
VRdy = VRd,c = 162kN
VEdy = 88.12kN
VEdy / VRdy = 0.543 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 800mm
β = 1.000
β NEd
νEd = = 2.023MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.647 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.833
ρl = min[ ρly ρlz , 0.02 ] = 0.00393
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.437 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.389 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.437 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 2,610mm
β = 1.000
βVEd,red
νEd = = 0.425MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.875 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE B. C9(81)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.777 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.875 MPa
νEd / νRd = 0.486 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 367mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 330mm² → O.K
sx = 100mm < sreq = 309mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 382mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 344mm² → O.K
sy = 100mm < sreq = 309mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE C. C10(69)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
(3) γc : 1.500 1,900
(4) γs : 1.150 950 950
(5) αcc : 0.850
(6) δ : 1.000

2. Material

950
(1) fck : 20.00MPa

1,900
(2) fyk : 500MPa

3. Section Y1

950
(1) Foundation
Depth : 500mm X1

Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 200x200mm

4. Rebar
1,600

(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)
500

5. Foundation
(1) Foundation Size
Lx : 1.900m
Ly : 1.900m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 2 515 0.000 0.000 SERV :1.0D + (1.0LL)
1 Yes COMB. 2 515 0.000 0.000 SERV :1.0D + (1.0LL)
2 Yes COMB. 4 411 0.000 0.000 SERV :1.0D + (0.3LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 718 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 718 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 181 qs,top-right = 181
qs,bot-left = 181 qs,bot-right = 181
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE C. C10(69)

qs,max = 181 fe = 200


qs,max / fe = 0.904 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 254 qu,top-right = 254
qu,bot-left = 254 qu,bot-right = 254
qu,max = 254 qu,min = 254

8. Calculate Moment Effective Depth


(1) Direction X = 444mm (for MEdy )
(2) Direction Y = 432mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0218
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 422mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 469mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 562mm²
fyk
Asmax = 0.04 Ac = 20,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 86.07kNꞏm MRdy = 207kNꞏm
MEdy / MRdy = 0.415 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0231
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 410mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 482mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 577mm²
fyk
Asmax = 0.04 Ac = 20,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 86.07kNꞏm MRdx = 202kNꞏm
MEdx / MRdx = 0.426 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE C. C10(69)

11. Calculate Shear Effective Depth


(1) Direction X = 444mm (for VEdx )
(2) Direction Y = 432mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.671
ρl = min[ Asl /bw d, 0.02 ] = 0.00255
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 291kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 285kN
VRdx = VRd,c = 291kN
VEdx = 170kN
VEdx / VRdx = 0.585 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.680
ρl = min[ Asl /bw d, 0.02 ] = 0.00262
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 287kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 280kN
VRdy = VRd,c = 287kN
VEdy = 176kN
VEdy / VRdy = 0.613 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 800mm
β = 1.000
β NEd
νEd = = 2.618MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.837 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.676
ρl = min[ ρly ρlz , 0.02 ] = 0.00258
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.348 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.340 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.348 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 3,552mm
β = 1.000
βVEd,red
νEd = = 0.427MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.695 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE C. C10(69)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.679 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.695 MPa
νEd / νRd = 0.615 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 562mm²
As,max = 20,000mm²
As = 1,131 (P12@100) > As,req = 469mm² → O.K
sx = 100mm < sreq = 201mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 577mm²
As,max = 20,000mm²
As = 1,131 (P12@100) > As,req = 482mm² → O.K
sy = 100mm < sreq = 201mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE D. C11(54)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
(3) γc : 1.500 1,800

(4) γs : 1.150 900 900


(5) αcc : 0.850
(6) δ : 1.000

2. Material

900
(1) fck : 20.00MPa

1,800
(2) fyk : 500MPa
Y1
3. Section

900
(1) Foundation
X1
Depth : 500mm
Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 300x200mm

4. Rebar
1,600

(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)
500

5. Foundation
(1) Foundation Size
Lx : 1.800m
Ly : 1.800m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 2 465 0.000 0.000 SERV :1.0D + (1.0LL)
1 Yes COMB. 2 465 0.000 0.000 SERV :1.0D + (1.0LL)
2 Yes COMB. 4 382 0.000 0.000 SERV :1.0D + (0.3LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 646 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 646 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 181 qs,top-right = 181
qs,bot-left = 181 qs,bot-right = 181
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE D. C11(54)

qs,max = 181 fe = 200


qs,max / fe = 0.907 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 254 qu,top-right = 254
qu,bot-left = 254 qu,bot-right = 254
qu,max = 254 qu,min = 254

8. Calculate Moment Effective Depth


(1) Direction X = 444mm (for MEdy )
(2) Direction Y = 432mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0170
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 422mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 366mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 562mm²
fyk
Asmax = 0.04 Ac = 20,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 67.05kNꞏm MRdy = 207kNꞏm
MEdy / MRdy = 0.323 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0204
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 410mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 428mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 577mm²
fyk
Asmax = 0.04 Ac = 20,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 76.29kNꞏm MRdx = 202kNꞏm
MEdx / MRdx = 0.378 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE D. C11(54)

11. Calculate Shear Effective Depth


(1) Direction X = 444mm (for VEdx )
(2) Direction Y = 432mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.671
ρl = min[ Asl /bw d, 0.02 ] = 0.00255
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 276kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 270kN
VRdx = VRd,c = 276kN
VEdx = 119kN
VEdx / VRdx = 0.430 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.680
ρl = min[ Asl /bw d, 0.02 ] = 0.00262
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 272kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 265kN
VRdy = VRd,c = 272kN
VEdy = 146kN
VEdy / VRdy = 0.535 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 1,000mm
β = 1.000
β NEd
νEd = = 1.881MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.601 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.676
ρl = min[ ρly ρlz , 0.02 ] = 0.00258
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.348 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.340 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.348 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 3,752mm
β = 1.000
βVEd,red
νEd = = 0.331MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.695 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE D. C11(54)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.679 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.695 MPa
νEd / νRd = 0.476 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 562mm²
As,max = 20,000mm²
As = 1,131 (P12@100) > As,req = 366mm² → O.K
sx = 100mm < sreq = 201mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 577mm²
As,max = 20,000mm²
As = 1,131 (P12@100) > As,req = 428mm² → O.K
sy = 100mm < sreq = 201mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE E. C12(65)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
1,500
(3) γc : 1.500
(4) γs : 1.150 750 750

(5) αcc : 0.850


(6) δ : 1.000

750
2. Material
(1) fck : 20.00MPa

1,500
(2) fyk : 500MPa
Y1
3. Section

750
(1) Foundation X1
Depth : 400mm
Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 200x300mm

4. Rebar
1,600

(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)
400

5. Foundation
(1) Foundation Size
Lx : 1.500m
Ly : 1.500m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 2 330 0.000 0.000 SERV :1.0D + (1.0LL)
1 Yes COMB. 2 330 0.000 0.000 SERV :1.0D + (1.0LL)
2 Yes COMB. 4 267 0.000 0.000 SERV :1.0D + (0.3LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 459 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 459 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 182 qs,top-right = 182
qs,bot-left = 182 qs,bot-right = 182
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE E. C12(65)

qs,max = 182 fe = 200


qs,max / fe = 0.910 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 255 qu,top-right = 255
qu,bot-left = 255 qu,bot-right = 255
qu,max = 255 qu,min = 255

8. Calculate Moment Effective Depth


(1) Direction X = 344mm (for MEdy )
(2) Direction Y = 332mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0217
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 327mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 361mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 432mm²
fyk
Asmax = 0.04 Ac = 16,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 51.28kNꞏm MRdy = 161kNꞏm
MEdy / MRdy = 0.319 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0198
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 315mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 319mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 447mm²
fyk
Asmax = 0.04 Ac = 16,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 43.70kNꞏm MRdx = 155kNꞏm
MEdx / MRdx = 0.282 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE E. C12(65)

11. Calculate Shear Effective Depth


(1) Direction X = 344mm (for VEdx )
(2) Direction Y = 332mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.762
ρl = min[ Asl /bw d, 0.02 ] = 0.00329
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 204kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 189kN
VRdx = VRd,c = 204kN
VEdx = 105kN
VEdx / VRdx = 0.513 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.776
ρl = min[ Asl /bw d, 0.02 ] = 0.00341
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 201kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 185kN
VRdy = VRd,c = 201kN
VEdy = 91.26kN
VEdy / VRdy = 0.454 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 1,000mm
β = 1.000
β NEd
νEd = = 1.701MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.544 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.769
ρl = min[ ρly ρlz , 0.02 ] = 0.00335
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.400 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.368 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.400 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 3,124mm
β = 1.000
βVEd,red
νEd = = 0.361MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.800 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE E. C12(65)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.737 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.800 MPa
νEd / νRd = 0.451 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 432mm²
As,max = 16,000mm²
As = 1,131 (P12@100) > As,req = 361mm² → O.K
sx = 100mm < sreq = 262mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 447mm²
As,max = 16,000mm²
As = 1,131 (P12@100) > As,req = 319mm² → O.K
sy = 100mm < sreq = 262mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE F. C13(84)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
1,000
(3) γc : 1.500
500 500
(4) γs : 1.150
(5) αcc : 0.850
(6) δ : 1.000

500
2. Material

1,000
(1) fck : 20.00MPa
Y1
(2) fyk : 500MPa

500
3. Section X1

(1) Foundation
Depth : 350mm
Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 300x200mm
1,600

4. Rebar
(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)
350

5. Foundation
(1) Foundation Size
Lx : 1.000m
Ly : 1.000m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 2 63.98 0.000 0.000 SERV :1.0D + (1.0LL)
1 Yes COMB. 2 63.98 0.000 0.000 SERV :1.0D + (1.0LL)
2 Yes COMB. 4 60.15 0.000 0.000 SERV :1.0D + (0.3LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 87.20 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 87.20 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 97.19 qs,top-right = 97.19
qs,bot-left = 97.19 qs,bot-right = 97.19
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE F. C13(84)

qs,max = 97.19 fe = 200


qs,max / fe = 0.486 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 136 qu,top-right = 136
qu,bot-left = 136 qu,bot-right = 136
qu,max = 136 qu,min = 136

8. Calculate Moment Effective Depth


(1) Direction X = 294mm (for MEdy )
(2) Direction Y = 282mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.00442
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 279mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 62.87mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 367mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 7.635kNꞏm MRdy = 137kNꞏm
MEdy / MRdy = 0.0556 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.00627
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 268mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 85.61mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 382mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 9.972kNꞏm MRdx = 132kNꞏm
MEdx / MRdx = 0.0757 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE F. C13(84)

11. Calculate Shear Effective Depth


(1) Direction X = 294mm (for VEdx )
(2) Direction Y = 282mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.825
ρl = min[ Asl /bw d, 0.02 ] = 0.00385
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 127kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 113kN
VRdx = VRd,c = 127kN
VEdx = 3.711kN
VEdx / VRdx = 0.0292 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.842
ρl = min[ Asl /bw d, 0.02 ] = 0.00401
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 125kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 110kN
VRdy = VRd,c = 125kN
VEdy = 11.57kN
VEdy / VRdy = 0.0927 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 1,000mm
β = 1.000
β NEd
νEd = = 0.471MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.151 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.833
ρl = min[ ρly ρlz , 0.02 ] = 0.00393
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.437 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.389 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.437 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 2,810mm
β = 1.000
βVEd,red
νEd = = 0.0657MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.875 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE F. C13(84)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.777 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.875 MPa
νEd / νRd = 0.0751 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 367mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 62.87mm² → O.K
sx = 100mm < sreq = 309mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 382mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 85.61mm² → O.K
sy = 100mm < sreq = 309mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE G. C14(53)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
1,000
(3) γc : 1.500
500 500
(4) γs : 1.150
(5) αcc : 0.850
(6) δ : 1.000

500
2. Material

1,000
(1) fck : 20.00MPa
Y1
(2) fyk : 500MPa

500
3. Section X1
(1) Foundation
Depth : 300mm
Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 200x200mm
1,600

4. Rebar
(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)

5. Foundation
300

(1) Foundation Size


Lx : 1.000m
Ly : 1.000m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 4 14.61 0.000 0.000 SERV :1.0D + (0.3LL)
1 Yes COMB. 4 14.61 0.000 0.000 SERV :1.0D + (0.3LL)
2 Yes COMB. 2 10.29 0.000 0.000 SERV :1.0D + (1.0LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 12.97 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 12.97 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 47.17 qs,top-right = 47.17
qs,bot-left = 47.17 qs,bot-right = 47.17
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE G. C14(53)

qs,max = 47.17 fe = 200


qs,max / fe = 0.236 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 60.74 qu,top-right = 60.74
qu,bot-left = 60.74 qu,bot-right = 60.74
qu,max = 60.74 qu,min = 60.74

8. Calculate Moment Effective Depth


(1) Direction X = 244mm (for MEdy )
(2) Direction Y = 232mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.00344
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 232mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 40.65mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 302mm²
fyk
Asmax = 0.04 Ac = 12,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 4.097kNꞏm MRdy = 114kNꞏm
MEdy / MRdy = 0.0359 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.00381
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 220mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 42.75mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 317mm²
fyk
Asmax = 0.04 Ac = 12,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 4.097kNꞏm MRdx = 108kNꞏm
MEdx / MRdx = 0.0378 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE G. C14(53)

11. Calculate Shear Effective Depth


(1) Direction X = 244mm (for VEdx )
(2) Direction Y = 232mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.905
ρl = min[ Asl /bw d, 0.02 ] = 0.00464
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 117kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 100kN
VRdx = VRd,c = 117kN
VEdx = 5.663kN
VEdx / VRdx = 0.0483 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.928
ρl = min[ Asl /bw d, 0.02 ] = 0.00488
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 115kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 97.25kN
VRdy = VRd,c = 115kN
VEdy = 6.392kN
VEdy / VRdy = 0.0557 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 800mm
β = 1.000
β NEd
νEd = = 0.319MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.102 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.917
ρl = min[ ρly ρlz , 0.02 ] = 0.00475
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.487 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.415 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.487 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 2,295mm
β = 1.000
βVEd,red
νEd = = 0.0658MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.975 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE G. C14(53)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.831 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.975 MPa
νEd / νRd = 0.0675 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 302mm²
As,max = 12,000mm²
As = 1,131 (P12@100) > As,req = 40.65mm² → O.K
sx = 100mm < sreq = 375mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 317mm²
As,max = 12,000mm²
As = 1,131 (P12@100) > As,req = 42.75mm² → O.K
sy = 100mm < sreq = 375mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE H. C15(7)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
(3) γc : 1.500 1,900
(4) γs : 1.150 950 950
(5) αcc : 0.850
(6) δ : 1.000

2. Material

950
(1) fck : 20.00MPa

1,900
(2) fyk : 500MPa

3. Section Y1

950
(1) Foundation
Depth : 500mm X1

Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 200x200mm

4. Rebar
1,600

(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)
500

5. Foundation
(1) Foundation Size
Lx : 1.900m
Ly : 1.900m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 2 516 0.000 0.000 SERV :1.0D + (1.0LL)
1 Yes COMB. 2 516 0.000 0.000 SERV :1.0D + (1.0LL)
2 Yes COMB. 4 420 0.000 0.000 SERV :1.0D + (0.3LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 717 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 717 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 181 qs,top-right = 181
qs,bot-left = 181 qs,bot-right = 181
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE H. C15(7)

qs,max = 181 fe = 200


qs,max / fe = 0.905 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 254 qu,top-right = 254
qu,bot-left = 254 qu,bot-right = 254
qu,max = 254 qu,min = 254

8. Calculate Moment Effective Depth


(1) Direction X = 444mm (for MEdy )
(2) Direction Y = 432mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0218
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 422mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 469mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 562mm²
fyk
Asmax = 0.04 Ac = 20,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 85.97kNꞏm MRdy = 207kNꞏm
MEdy / MRdy = 0.414 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0230
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 410mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 482mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 577mm²
fyk
Asmax = 0.04 Ac = 20,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 85.97kNꞏm MRdx = 202kNꞏm
MEdx / MRdx = 0.426 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE H. C15(7)

11. Calculate Shear Effective Depth


(1) Direction X = 444mm (for VEdx )
(2) Direction Y = 432mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.671
ρl = min[ Asl /bw d, 0.02 ] = 0.00255
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 291kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 285kN
VRdx = VRd,c = 291kN
VEdx = 170kN
VEdx / VRdx = 0.585 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.680
ρl = min[ Asl /bw d, 0.02 ] = 0.00262
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 287kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 280kN
VRdy = VRd,c = 287kN
VEdy = 176kN
VEdy / VRdy = 0.612 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 800mm
β = 1.000
β NEd
νEd = = 2.616MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.836 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.676
ρl = min[ ρly ρlz , 0.02 ] = 0.00258
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.348 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.340 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.348 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 3,552mm
β = 1.000
βVEd,red
νEd = = 0.427MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.695 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE H. C15(7)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.679 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.695 MPa
νEd / νRd = 0.614 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 562mm²
As,max = 20,000mm²
As = 1,131 (P12@100) > As,req = 469mm² → O.K
sx = 100mm < sreq = 201mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 577mm²
As,max = 20,000mm²
As = 1,131 (P12@100) > As,req = 482mm² → O.K
sy = 100mm < sreq = 201mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE I. C16(15)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
1,000
(3) γc : 1.500
500 500
(4) γs : 1.150
(5) αcc : 0.850
(6) δ : 1.000

500
2. Material

1,000
(1) fck : 20.00MPa
Y1
(2) fyk : 500MPa

500
3. Section X1

(1) Foundation
Depth : 350mm
Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 300x200mm
1,600

4. Rebar
(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)
350

5. Foundation
(1) Foundation Size
Lx : 1.000m
Ly : 1.000m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 4 43.27 0.000 0.000 SERV :1.0D + (0.3LL)
1 Yes COMB. 4 43.27 0.000 0.000 SERV :1.0D + (0.3LL)
2 Yes COMB. 2 39.94 0.000 0.000 SERV :1.0D + (1.0LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 53.21 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 53.21 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 76.47 qs,top-right = 76.47
qs,bot-left = 76.47 qs,bot-right = 76.47
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE I. C16(15)

qs,max = 76.47 fe = 200


qs,max / fe = 0.382 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 102 qu,top-right = 102
qu,bot-left = 102 qu,bot-right = 102
qu,max = 102 qu,min = 102

8. Calculate Moment Effective Depth


(1) Direction X = 294mm (for MEdy )
(2) Direction Y = 282mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.00321
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 279mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 45.73mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 367mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 5.553kNꞏm MRdy = 137kNꞏm
MEdy / MRdy = 0.0404 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.00456
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 268mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 62.27mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 382mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 7.253kNꞏm MRdx = 132kNꞏm
MEdx / MRdx = 0.0551 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE I. C16(15)

11. Calculate Shear Effective Depth


(1) Direction X = 294mm (for VEdx )
(2) Direction Y = 282mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.825
ρl = min[ Asl /bw d, 0.02 ] = 0.00385
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 127kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 113kN
VRdx = VRd,c = 127kN
VEdx = 1.807kN
VEdx / VRdx = 0.0142 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.842
ρl = min[ Asl /bw d, 0.02 ] = 0.00401
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 125kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 110kN
VRdy = VRd,c = 125kN
VEdy = 7.562kN
VEdy / VRdy = 0.0606 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 1,000mm
β = 1.000
β NEd
νEd = = 0.353MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.113 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.833
ρl = min[ ρly ρlz , 0.02 ] = 0.00393
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.437 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.389 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.437 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 2,810mm
β = 1.000
βVEd,red
νEd = = 0.0492MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.875 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE I. C16(15)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.777 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.875 MPa
νEd / νRd = 0.0563 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 367mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 45.73mm² → O.K
sx = 100mm < sreq = 309mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 382mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 62.27mm² → O.K
sy = 100mm < sreq = 309mm → O.K

2020-09-04 4
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE J. C17(6)

1. General Information
(1) Design Code : Eurocode2:04
(2) Unit System : N, mm
1,000
(3) γc : 1.500
500 500
(4) γs : 1.150
(5) αcc : 0.850
(6) δ : 1.000

500
2. Material

1,000
(1) fck : 20.00MPa
Y1
(2) fyk : 500MPa

500
3. Section X1

(1) Foundation
Depth : 350mm
Cover : 50.00mm
(2) Column Section
Shape of Column : Rectangle
Section : 200x200mm
1,600

4. Rebar
(1) Direction Y
Layer 1 : P12@100 (As = 1,131mm²)
(2) Direction X
Layer 1 : P12@100 (As = 1,131mm²)
350

5. Foundation
(1) Foundation Size
Lx : 1.000m
Ly : 1.000m
fe : 200KPa

6. Design Forces
(1) Service Load ( by Load Combinations )
NEd,s MEd,sx MEd,sy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 2 146 0.000 0.000 SERV :1.0D + (1.0LL)
1 Yes COMB. 2 146 0.000 0.000 SERV :1.0D + (1.0LL)
2 Yes COMB. 4 120 0.000 0.000 SERV :1.0D + (0.3LL)

(2) Ultimate Load ( by Load Combinations )


NEd,u MEd,ux MEd,uy
No CHK Name Description
(kN) (kNꞏm) (kNꞏm)
- - COMB. 1 202 0.000 0.000 1.35D + 1.5(1.0LL)
1 Yes COMB. 1 202 0.000 0.000 1.35D + 1.5(1.0LL)

(3) Surcharge Load & Self Weight


Self Weight Surface Load Weight Density Soil Height
Considered - 16.60kN/m³ 1.600m

7. Check Soil Capacity


(1) Calculate service soil stress (KPa)
qs,top-left = 179 qs,top-right = 179
qs,bot-left = 179 qs,bot-right = 179
2020-09-04 1
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE J. C17(6)

qs,max = 179 fe = 200


qs,max / fe = 0.897 → O.K
(2) Calculate ultimate soil stress (KPa)
qu,top-left = 252 qu,top-right = 252
qu,bot-left = 252 qu,bot-right = 252
qu,max = 252 qu,min = 252

8. Calculate Moment Effective Depth


(1) Direction X = 294mm (for MEdy )
(2) Direction Y = 282mm (for MEdx )

9. Check Moment Capacity ( Direction X ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0111
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 279mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 159mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 367mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdy = 19.25kNꞏm MRdy = 137kNꞏm
MEdy / MRdy = 0.140 → O.K

10. Check Moment Capacity ( Direction Y ) - for the unit width


(1) Calculate required area of reinforcement
MEd
K= = 0.0121
bd2 fck
K' = 0.598δ - 0.18δ2 - 0.21 = 0.208
z = min[ d(0.5+0.5 1-3.53K ), 0.95d ] = 268mm
(Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
As,req = = 165mm²
fyd z
(2) Calculate limit of reinforcement area
fctm = 0.3 fck = 2.210MPa
2/3

0.26 fctm bd
Asmin = max[ , 0.0013bd ] = 382mm²
fyk
Asmax = 0.04 Ac = 14,000mm²
(3) Check area of tensile reinforcement
As > As,req → O.K
As,min < As < As,max → O.K
(4) Calculate moment capacity at the column face
MEdx = 19.25kNꞏm MRdx = 132kNꞏm
MEdx / MRdx = 0.146 → O.K

2020-09-04 2
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE J. C17(6)

11. Calculate Shear Effective Depth


(1) Direction X = 294mm (for VEdx )
(2) Direction Y = 282mm (for VEdy )

12. Check One-Way Shear ( Direction X ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.825
ρl = min[ Asl /bw d, 0.02 ] = 0.00385
CRd,c = 0.18 / γc = 0.120
VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 127kN
VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 113kN
VRdx = VRd,c = 127kN
VEdx = 22.23kN
VEdx / VRdx = 0.175 → O.K

13. Check One-Way Shear ( Direction Y ) - for the whole width


(1) Calculate ratio of shear capacity
k = min [ 1 + 200/d , 2.0] = 1.842
ρl = min[ Asl /bw d, 0.02 ] = 0.00401
CRd,c = 0.18 / γc = 0.120
VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 125kN
VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 110kN
VRdy = VRd,c = 125kN
VEdy = 25.26kN
VEdy / VRdy = 0.202 → O.K

14. Check Two-Way Shear


(1) Calculate Shear at Face of Column
U = 800mm
β = 1.000
β NEd
νEd = = 1.093MPa
Ud
fcd = αcc fck / γc = 11.33MPa
νRd,max = 0.5ν fcd = 3.128MPa
νEd / νRdmax = 0.349 → O.K
(2) Calculate Shear at Distance-2d
U = 0.000mm
β = 1.000
β VEd,red
νEd = = 0.000MPa
Ud
k = min [ 1 + 200/d , 2.0] = 1.833
ρl = min[ ρly ρlz , 0.02 ] = 0.00393
νRd,1 = CRd,c k (100 ρl fck ) 1/3 + k1 σcp = 0.437 MPa
νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.389 MPa
νRd = max[ νRd,1 , νRd,2 ] = 0.437 MPa
νEd / νRd = 0.000 → O.K
(3) Calculate Shear at Distance-d
U = 2,610mm
β = 1.000
βVEd,red
νEd = = 0.157MPa
Ud
νRd,1 = CRd,c k (100 ρl fck ) 1/3 x (2d/a) = 0.875 MPa
2020-09-04 3
CSEC [U] LTD. http://www.csecengltd.com
+256(0)292 947 199

MEMBER NAME : BASE TYPE J. C17(6)

νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.777 MPa


νRd = max[ νRd,1 , νRd,2 ] = 0.875 MPa
νEd / νRd = 0.180 → O.K

15. Check Rebar


(1) Calculate maximum rebar spacing limit (X Direction)
As,min = 367mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 159mm² → O.K
sx = 100mm < sreq = 309mm → O.K
(2) Calculate maximum rebar spacing limit (Y Direction)
As,min = 382mm²
As,max = 14,000mm²
As = 1,131 (P12@100) > As,req = 165mm² → O.K
sy = 100mm < sreq = 309mm → O.K

2020-09-04 4

You might also like