You are on page 1of 7

OTTV CALCULATION

(EXISTING)
A B C D E F
OTTV Solar Window Wall
COMPONENT Wall Wall Constant Absorption to Wall (1-WWR) Constr
Location Areas Factor Ratio U-Value
(m2) (a) (WWR) (Uv)
North Wall 1149 15 0.15 0.64 0.36 2.61
HEAT South Wall 1149 15 0.15 0.62 0.38 2.61
CONDUCTION East Wall 1322 15 0.15 0.61 0.39 2.61
THROUGH West Wall 1322 15 0.15 0.61 0.39 2.61
WALLS 4942 Equation for Heat Conduction Through Walls =
North Window 1149 6 N/A 0.64 N/A N/A
HEAT South Window 1149 6 N/A 0.62 N/A N/A
CONDUCTION East Window 1322 6 N/A 0.61 N/A N/A
THROUGH West Window 1322 6 N/A 0.61 N/A N/A
WINDOWS Equation for Heat Conduction Through Windows =
North Window 1149 194 N/A 0.64 N/A N/A
SOLAR HEAT South Window 1149 194 N/A 0.62 N/A N/A
GAIN East Window 1322 194 N/A 0.61 N/A N/A
THROUGH West Window 1322 194 N/A 0.61 N/A N/A
WINDOWS Equation for Solar Heat Gain Through Window =
LCULATION

G H I J K L
Glass Device Shading Wall OTTV
Glass Orientation Shading Shading Coefficient (in multiply all % of
U-Value Factor Coelf Coelf SC1 x SC2 shaded cells in the OTTV
(UF) (OF) (SC1) (SC2) (the column I x J) same row)
N/A N/A N/A N/A N/A 2429.10
N/A N/A N/A N/A N/A 2564.05
N/A N/A N/A N/A N/A 3027.74
N/A N/A N/A N/A N/A 3027.74
rough Walls = 15 x a x (1 -WWR) Uv 11048.64 2.65%
5.7 N/A N/A N/A N/A 25149.31
5.7 N/A N/A N/A N/A 24363.40
5.7 N/A N/A N/A N/A 27579.56
5.7 N/A N/A N/A N/A 27579.56
6 x WWR x Uf 104671.84 25.14%
N/A 0.9 0.51 1.00 0.51 65480.87
N/A 1.23 0.51 1.00 0.51 86693.94
N/A 0.92 0.51 1.00 0.51 73404.22
N/A 0.94 0.51 1.00 0.51 74999.96
194 x WWR x OF x SC 300578.99 72.20%
å WALL OTTV = 416299.46 100%
å WALL AREA = 4942
OTTV = 84.24
(PROPOSE EXTERNAL SHA
A B C D E
OTTV Solar Window
COMPONENT Wall Wall Constant Absorption to Wall (1-WWR)
Location Areas Factor Ratio
(m2) (a) (WWR)
North Wall 1149 15 0.15 0.64 0.36
HEAT South Wall 1149 15 0.15 0.62 0.38
CONDUCTION East Wall 1322 15 0.15 0.61 0.39
THROUGH West Wall 1322 15 0.15 0.61 0.39
WALLS 4942 Equation for Heat Conduction Through Walls =
North Window 1149 6 N/A 0.64 N/A
HEAT South Window 1149 6 N/A 0.62 N/A
CONDUCTION East Window 1322 6 N/A 0.61 N/A
THROUGH West Window 1322 6 N/A 0.61 N/A
WINDOWS Equation for Heat Conduction Through Windows =
North Window 1149 194 N/A 0.64 N/A
SOLAR HEAT South Window 1149 194 N/A 0.62 N/A
GAIN East Window 1322 194 N/A 0.61 N/A
THROUGH West Window 1322 194 N/A 0.61 N/A
WINDOWS Equation for Solar Heat Gain Through Window =
OTTV CALCULATION
(PROPOSE EXTERNAL SHADING DEVICE)
F G H I J K
Wall Glass Device Shading
Constr Glass Orientation Shading Shading Coefficient
U-Value U-Value Factor Coelf Coelf SC1 x SC2
(Uv) (UF) (OF) (SC1) (SC2) (the column I x J)
2.61 N/A N/A N/A N/A N/A
2.61 N/A N/A N/A N/A N/A
2.61 N/A N/A N/A N/A N/A
2.61 N/A N/A N/A N/A N/A
duction Through Walls = 15 x a x (1 -WWR) Uv
N/A 5.6 N/A N/A N/A N/A
N/A 5.6 N/A N/A N/A N/A
N/A 5.6 N/A N/A N/A N/A
N/A 5.6 N/A N/A N/A N/A
ugh Windows = 6 x WWR x Uf
N/A N/A 0.9 0.51 0.77 0.39
N/A N/A 0.92 0.51 0.77 0.39
N/A N/A 1.32 0.51 0.82 0.42
N/A N/A 0.94 0.51 0.81 0.41
gh Window = 194 x WWR x OF x SC
å WALL OTTV =
å WALL AREA =
OTTV =
L
Wall OTTV
(in multiply all % of
shaded cells in the OTTV
same row)
2429.10
2564.05
3027.74
3027.74
11048.64 3.05%
24708.10
23935.97
27095.71
27095.71
102835.49 28.89%
50420.27
49930.07
86361.66
60749.97
247461.97 68.14%
361346.09 100%
4942.00
73.12
OTTV CALCULATION
(PROPOSE GLASS SELECT
A B C D E F
OTTV Solar Window Wall
COMPONENT Wall Wall ConstantAbsorption to Wall (1-WWR) Constr
Location Areas Factor Ratio U-Value
(m2) (a) (WWR) (Uv)
North Wall 1149 15 0.15 0.64 0.36 2.61
HEAT South Wall 1149 15 0.15 0.62 0.38 2.61
CONDUCTION East Wall 1322 15 0.15 0.61 0.39 2.61
THROUGH West Wall 1322 15 0.15 0.61 0.39 2.61
WALLS 4942 Equation for Heat Conduction Through Walls =
North Window 1149 6 N/A 0.64 N/A N/A
HEAT South Window 1149 6 N/A 0.62 N/A N/A
CONDUCTION East Window 1322 6 N/A 0.61 N/A N/A
THROUGH West Window 1322 6 N/A 0.61 N/A N/A
WINDOWS Equation for Heat Conduction Through Windows =
North Window 1149 194 N/A 0.64 N/A N/A
SOLAR HEAT South Window 1149 194 N/A 0.62 N/A N/A
GAIN East Window 1322 194 N/A 0.61 N/A N/A
THROUGH West Window 1322 194 N/A 0.61 N/A N/A
WINDOWS Equation for Solar Heat Gain Through Window =
OTTV CALCULATION
POSE GLASS SELECTION)
G H I J K L
Glass Device Shading Wall OTTV
Glass Orientation Shading Shading Coefficient (in multiply all % of
U-Value Factor Coelf Coelf SC1 x SC2 shaded cells in the OTTV
(UF) (OF) (SC1) (SC2) (the column I x J) same row)
N/A N/A N/A N/A N/A 2429.10
N/A N/A N/A N/A N/A 2564.05
N/A N/A N/A N/A N/A 3027.74
N/A N/A N/A N/A N/A 3027.74
on Through Walls = 15 x a x (1 -WWR) Uv 11048.64 5.46%
3.7 N/A N/A N/A N/A 16324.99
3.7 N/A N/A N/A N/A 15814.84
3.7 N/A N/A N/A N/A 17902.52
3.7 N/A N/A N/A N/A 17902.52
h Windows = 6 x WWR x Uf 67944.88 34.83%
N/A 0.9 0.25 0.77 0.19 24715.82
N/A 0.92 0.25 0.77 0.19 24475.52
N/A 1.32 0.25 0.82 0.21 42334.15
N/A 0.94 0.25 0.81 0.20 29779.40
Window = 194 x WWR x OF x SC 121304.89 59.79%
å WALL OTTV = 200298.40 100%
å WALL AREA = 4942.00
OTTV = 40.53