AK 200™ S and

AK 200 ULTRA S systems


®

Specifications
AK 200™ S
Features
Quick preparation
Automatic self-test
Pre-settable treatment parameters

Treatment flexibility
• Pre-settable acetate/bicarbonate
fluid composition
• Direct setting of Na + and HCO 3-
• Adjustable dialysis fluid flow
• Profiling of Na +, HCO 3- and UF
• Single needle/Single pump with low
recirculation
• Single needle/Double pump with low
recirculation Isolated UF
• Hemodiafiltration
• BiCart Select®
• Blood Volume Sensor

Hygiene Options
Chemical and heat disinfection— pH meter
automatic and integrated Ultrafiltered dialysis fluid
CleanCart® cleaning, decalcification, Battery backup
disinfection Electrical adjustable stand
Pre-settable disinfection options, One or two blood pumps
chemical disinfection memory Blood pressure meter
Automatic disinfection cycle verification Diascan®

Specifications
Blood flow control Dialysis fluid preparation Power consumption
Flow rate, double needle: and monitoring Max 2250 W at 230 V or 1650 W at 115 V
0 and 20 to 500 ml/min Temperature: Fully prepared for battery backup
Flow rate, single needle, single pump: Adjustable between 30 to 39 °C
0 and 20 to 500 ml/min, time or Flow rate: 300 to 700 ml/min Connection of external equipment
pressure-controlled Acetate mode: Connectors: RS 232 C or RS 422
Mean flow, single-needle, double pump: Na+ range 115 to 160 mmol/l
0 and 10 to 400 ml/min, stroke volume Bicarbonate mode:
controlled Dimensions and weight
Na+ range 130 to 150 mmol/l Weight: 81 to 88 kg
HCO 3- range 20 to 40 mmol/l Width: Machine 570 mm, stand 573 mm
Blood pressure supervision pH meter: Range 1.0 to 9.9
Arterial pressure: -700 to +750 mmHG Depth: Machine 610 mm, stand 753 mm
System pressure: -700 to +750 mmHG Height: 1152 to 1382 mm in 5 fi xed
Substitution fluid positions or 1175 to 1340 mm adjustable
Venous pressure: -700 to +750 mmHG Substitution flow rate: 1.0 to 2.0 l/h ± 10%
Operating environment
Air detection (Level detector) Ultrafiltration control Ambient temperature: 18 to 35 °C
Method: Ultrasonic detector UF volume: Adjustable, 0 to 30 l Relative humidity: 15 to 85%
Drip chamber size: 22 mm diameter Accuracy: ± 50 ml/h or ± 2.5% Approx. 2000 meters above sea level
UF rate: 0 to 4 l/h
Heparin administration
Safety
Flow rate: 0 to 10 ml/h, programmable Blood leakage detection
stop time, accumulated volume read-out The AK 200 S system complies with the
Infrared light following standards:
Water supply IEC 60601-1 General requirements for
Disinfection and cleaning safety, Class 1, type B
Inlet pressure: 100 to 800 kPa (1 to 8 bar)
Chemical: Peracetic acid, hypochlorite
Inlet temperature: 5 to 30°C or formaldehyde IEC 60601-2-16 Particular requirements
Quality: Fluid should comply with for safety of haemodialysis, haemodia -
Heat: Heat, liquid citric acid or CleanCart®
national & international standards, filtration and haemofiltration equipment
Rinse/drain/decalcification:
e.g. ANSI/AAMI IEC 60601-2-30 Particular requirements
Rinse, citric acid or CleanCart C®
for the safety of automatic cycling indirect
Optional modes blood pressure monitoring equipment
Power supply
Profiling: Sodium, bicarbonate and UF IEC 60601-1-2 Electromagnetic compatibility
Mains voltage: 115/230V AC (± 10%)
Hemodiafiltration: Single or double-needle
Frequency: 50 to 60 Hz (± 5Hz)
CE 0086 This product is CE-marked in accordance with
the requirements in EC Council Directive 93/42/EEC of
14 June, 1993, concerning medical devices

Specifi cations subject to change without notice. For further information and operating instructions, please refer to the operators manual.
AK 200 ULTRA® S
Features
Quick preparation Quic
Automatic self-test Auto
Pre-settable treatment parameters Pre-

Treatment flexibility Trea


• Online HDF with pre- or post-dilution • O
• Online HF with pre- or post-dilution • On
• All modes with ultra-pure dialysis fluid • Al
• Online preparation of substitution fluid • On
for HF and HDF fo
• Adjustable dialysis fluid flow • Ad
300-700 ml/min 30
• Profiling of Na +, HCO 3- and UF • P
• Designed for the BiCart® and • D
BiCart Select system B
• SN/SP and SN/DP with minimum • SN
recirculation re
• Blood Volume Sensor • B
• D
Hygiene Options
Chemical and heat disinfection— pH meter
automatic and integrated Battery backup
CleanCart® cleaning, decalcification, Electrical adjustable stand
disinfection Blood pressure meter
Chemical disinfection memory Diascan®

Specifications
Blood flow control Dialysis fluid preparation Power consumption:
Flow rate, double needle: and monitoring Max 2250 W at 230 V
0 and 20 to 500 ml/min (HD) Temperature: Fully prepared for battery backup
0 and 20 to 700 ml/min (HDF/HF) Adjustable between 30 to 39 °C
Flow rate, single needle, single pump: Flow rate: 300 to 700 ml/min Connection of external equipment
0 and 20 to 500 ml/min, time- or Acetate mode: Connectors: RS 232 C or RS 422
pressure-controlled Na+ range 115 to 160 mmol/l
Mean flow, single-needle, double pump: Bicarbonate mode: Dimensions and weight
0 and 10 to 400 ml/min, stroke volume Na+ range 130 to 150 mmol/l, Weight: 81 to 88 kg
controlled HCO 3- 20 to 40 mmol/l Width: Machine 570 mm, stand 573 mm
pH meter: Range 1.0 to 9.9 Depth: Machine 610 mm, stand 753 mm
Blood pressure supervision Height: 1152 to 1382 mm in 5 fi xed
Arterial pressure: -700 to +750 mmHG Substitution fluid positions or 1175 to 1340 mm adjustable
System pressure: -700 to +750 mmHG Substitution flow rate: 0.3 to 27 l/h
Venous pressure: -700 to +750 mmHG Substitution fluid volume: 0 to 150 litres Operating environment
Ambient temperature: 18 to 35 °C
Air detection (Level detector) Ultrafiltration control Relative humidity: 15 to 85%
Method: Ultrasonic detector UF volume: Adjustable, 0 to 30 l Approx. 2000 meters above sea level
Drip chamber size: 22 mm diameter Accuracy: ± 50ml/h or ± 2.5%
UF rate: 0 to 4 l/h Safety
Heparin administration The AK 200 ULTRA S system complies with
Blood leakage detection the following standards:
Flow rate: 0 to 10 ml/h, programmable
stop time, accumulated volume read-out Infrared light IEC 60601-1 General requirements for
safety, Class 1, type B
Disinfection and cleaning
Water supply IEC 60601-2-16 Particular requirements
Chemical: Peracetic acid, hypochlorite
Inlet pressure: 120 to 800 kPa (1 to 8 bar) for safety of hemodialysis, hemodiafiltration
or formaldehyde
Inlet temperature: 5 to 30°C and hemofiltration equipment
Heat: Heat, liquid citric acid or CleanCart®
Quality: Fluid should comply with Rinse/drain/decalcification: IEC 60601-2-30 Particular requirements
national & international standards, Rinse, citric acid or CleanCart C® for the safety of automatic cycling indirect
e.g. ANSI/AAMI blood pressure monitoring equipment
Power supply IEC 60601-1-2 Electromagnetic compatibility
Optional modes Mains voltage: 115/230V AC (± 10%)
Profiling: Sodium, bicarbonate and UF Frequency: 50 to 60 Hz (± 5Hz) CE 0086 This product is CE-marked in accordance with
Hemodiafiltration: Single or double-needle the requirements in EC Council Directive 93/42/EEC of
14 June, 1993, concerning medical devices

Specifi cations subject to change without notice. For further information and operating instructions, please refer to the operators manual.
HCEN2391_4 © 2009.04. Gambro Lundia AB
AK 200 ULTRA® S is a trademark of Gambro Lundia AB, registered in the European Union.

Gambro Lundia AB
Box 10101, 220 10 Lund
Sweden
Tel +46 46 16 90 00
Fax + 46 46 16 96 97
www.gambro.com