You are on page 1of 2

The AK 96 machine

Efficient version
Developed to deliver outstanding and consistent HD treatments, the Efficient
version of the AK 96 machine with its selected features raises the quality and
level of treatments, operational efficiency, control and ease of use. Selected
features include a complete integration with Gambro water treatment systems
and a heparin Heparin pump.
The Efficient version of the AK 96 machine was developed to rise to the
challenge. Any challenge.

BiCart

Essential component of a system

designed to avoid treatment related


inflammation

Battery back-up

For safe treatments in all


environments

Variable dialysate fluid flow


For added treatment flexibility
and economy

Arterial blood line clamp

For enhanced treatment safety


and flexibility, part of the overall
surveillance of the vascular access
of the patient.

Consistently high treatment quality

Technical specifications

Conductivity-based and flow-rate


controlled concentrate dosing

Disinfection log

BiCart cartridge holder

Heparin pump

Alarm pole

Option

pH probe

Option

Operational efficiency
Automatic self-test

Stand-by mode

Profiling modules

Assisted priming

Variable dialysate fluid flow

Automated heat disinfection


processes

Concentrate standby mode

Ease of use and staff satisfaction


Single needle mode

Automatic heparin bolus

Auto rinse back

Automatic switch from isolated UF


to diffusion
Decalcification and cleaning with
CleanCart cartridges
Pre-settable for different
disinfectants
Pre-configuration options (start-up
values, limits, limitations)

Battery back-up

Prepared for Softpac concentrate

Safety
The AK 96 machine complies with the following standards:
IEC 60601-1 General requirements for safety, Class I, type B
IEC 60601-2-16 Particular requirements for safety of hemodialysis,
hemodiafiltration and hemofiltration equipment
IEC 60601-1-1 Safety requirements for medical electrical systems
IEC 60601-1-2 Electromagnetic compatibility, class B
IEC 60601-2-30 Particular requirements for the safety of automatic
cycling indirect blood pressure monitoring equipment
EN 1060-1 Non-invasive sphygmomanometers Part 1: General
requirements
EN 1060-3 Non-invasive sphygmomanometers Part 3: Supplementary
requirements for electromechanical blood pressure measuring systems
Gambro is a registered trademark of Gambro Lundia AB
AK 96, CleanCart, BiCart and SoftPac are trade marks belonging to Gambro
Specifications subject to change without notice. For further information
and operating instructions, please refer to the operator manual

*An event of venous needle disconnection is not guaranteed to be


detected by most dialysis machines. International standards recommend
additional venous access monitoring is used to safeguard patient safety.

Gambro Lundia AB
PO Box 10101, SE-22010 Lund, Sweden
Phone + 46 46 16 90 00
partner@gambro.com, www.gambro.com

Blood flow control


Flow rate, double needle: 0 and 20 to 500 ml/min
Flow rate, single needle: 0 and 20 to 500 ml/min, pressure-controlled
Blood circuit pressure supervision
Arterial pressure: 700 to +750 mmHg
Venous pressure*: 700 to +750 mmHg
Air detection
Method: Ultrasonic detector
Drip chamber size: 22 mm diameter
Heparin administration
Flow rate: 0 to 10 ml/h
Programmable stop time, accumulated volume read-out and bolus
Water supply
Inlet pressure: 0.12 to 0.6 MPa (1.2 to 6 bar)
Inlet temperature: 5 to 30C
Quality: Fluid must comply with appropriate regulations and as minimum
ISO 13959
Dialysis fluid preparation and monitoring
Flow rate: 300700 ml/min (by step of 20 ml/min)
Acetate Mode: Na+ 130 to 160 mmol/l
Bicarbonate Mode: Na+ 130 to 160 mmol/l
HCO3- 20 to 40 mmol/l
pH meter option: range 1.0 to 9.9
Profiling (Na+, HCO3-, UF)
Concentrate standby mode
Ultrafiltration control
UF volume: Adjustable, 0 to 10.00 l
Accuracy: 50 ml/h or 1%
UF rate: 0 to 4 l/h
Blood leakage detection
Method: Infrared light
Disinfection and cleaning
Automated disinfection process with Gambro water treatment systems
Heat, liquid citric acid or CleanCart disinfectant
Chemical: Peracetic acid, hypochlorite or formaldehyde
Disinfection log
Power supply
Mains voltage: 115, 230 V
Frequency: 50 to 60 Hz
Power consumption: Max 2025 W at 230 V, 1575 W at 115 V
Connection of external equipment
Connector: 25 pin D-sub with RS232C or RS-422/current loop
Dimensions and weight
Width: Machine 345 mm, stand 585 mm
Depth: Machine 600 mm, stand 620 mm
Height: 1305 mm
Weight: Approx. 60 kg (without options)
Operating environment
Ambient temperature: 18 to 35C
Relative humidity: 15 to 85%
Air pressure: Up to approx. 2500 meters above sea level (70 to 106 kpa)

HCEN4965_3 2010.04. Gambro Lundia AB

The AK 96 machine, Efficient version