Scania CV AB, Sweden, 2001-06:2
Important information
• Changes must not be made to the DEC2 control unit or sensors and wiring. Doing so
may affect the control unit safety system and cause injuries to the operator and
damage to the engine or driven equipment.
• Never splice a damaged cable. Renew the entire cable, otherwise the safety and
operation of the system could be impaired.
• Sensors for the DEC2 control system are intended only for use in the DEC2.
The following points must be observed to ensure that the DEC2 control
unit is not damaged:
• Check that cables to the battery and generator are properly connected before the
engine is started.
• Before disconnecting the cable to the control unit, switch off all power supply to the
unit.
• Disconnect the DEC2 control unit when rapid charging the battery.
• Disconnect the battery during electric welding and remove the control unit.
Contents
Start-up procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Tuning: single speed or all speed engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Changing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Explanation of the other parameters shown on the Tuning screen . . . . . . . . . 6
Explanation of the function keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Governor Configuration: All speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Changing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Explanation of the other parameters shown on the Configuration screen: . . . 8
Governor Configuration: Single speed engine . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Changing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Governor Calibration: All speed and single speed engines . . . . . . . . . . . . . . . . 10
Calibration procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Saving the calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Calibration has failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Final check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Possible error messages that can occur during calibration . . . . . . . . . . . . . . 18
2 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03
Start-up procedure
Note: The PC should only be connected to the control unit using a special cable marked
DEC at one end and PC at the other, after the cover over the COMM/DIAG PORT has
been removed. The cable part no. is 1434119 for length=4 m and 1413708 for
length=10 m. The program can only be started if the PC is connected to a powered
control unit. However, the program menu below can be reached without powering
the control unit.
All Dealer program versions with instructions are collected on a CD with part No.
1589210 with subscription and part No. 1588695 without subscription.
or
03:03-03 ©
Scania CV AB, Sweden, 2001-06:2 3
Governor
<T> Tuning
<K> Configuration
<C> Calibration
<I> Maintenance Information
- Under the heading PC Software, information - With Shift+Tab the cursor is moved backwards
can be stored about the specific OEM. between the modifiable parameter fields.
- When the space bar is pressed, the user is
prompted to enter a new value.
- Enter the new chosen value.
- Confirm by pressing Enter.
- Save by pressing F2. See page 7 for a
description of the use of the function keys.
4 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03
Tuning: single speed or all speed engine
03:03-03 ©
Scania CV AB, Sweden, 2001-06:2 5
Explanation of the other parameters shown on the Tuning screen
Speed Droop = Calculated speed reduction Boost Press = Absolute charge air pressure
depending on current speed droop. after the turbocharger
Velocity = Actual speed Atemp LOP = Shows the limit value (warning
level) for charge air temperature when operation
Starting Fuel = Maximum control rack travel
can be set to switch over to limited power level
during startup (starting cycle).
(POWER).
Actual Fuel = Current control rack travel
Etemp LOP = Shows the limit value (warning
Operating Mode = Shows current operating level) for coolant air temperature when operation
mode can be set to switch over to limited power level
Air Temp = Air temperature in inlet manifold (POWER).
Engine Temp = Coolant temperature in Eng. Shutdn = Shows limit value (shutdown
engine level) for coolant temperature when control unit
shuts down the engine (if DIPswitch 4 on the
Load = Shows actual load at current speed. control unit is set in the OFF position).
Speed Request = Requested speed signal OS Limit = Shows the overspeed value at
from throttle position sensor. which the engine will be shut down.
Torque Limit = Shows maximum control rack OS Time Limit = Shows the time delay
travel in the torque limiter map at current between the overspeed and engine
speed. shutdown.
Boost fuel = Shows maximum control rack Speed Accel = Shows the acceleration time
travel in the smoke limiter map at current required for the control rack to reach its
speed and boost pressure. programmed maximum travel.
Oil Pressure = Oil pressure in engine. Speed Decel = Same as Speed Accel but
Displays the same value as long as the from maximum to minimum control rack
engine is running. travel.
Atmospheric P = Shows the atmospheric The actual ramp time will be somewhat
pressure before the starting cycle. This value shorter than the value entered for Speed
is updated before each startup. Accel and Speed Decel.
6 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03
Explanation of the function keys
F1 - Update = All recorded parameter values F3 - File = When this key is pressed, the user
in the control unit are updated and displayed is prompted for a file name in order to store in
on the screen a separate file the parameters which can be
modified. This file can be printed and saved
F2 - Save = All the modifiable values shown
for reference or troubleshooting.
on the screen are saved and stored in the
permanent control unit memory. F5 - Continuous updating = The screen is
updated approximately once every second
Each value is now retrieved at every reset
when this key is pressed. The function is
(restart) until it is changed again. If a
cancelled if F5 is pressed again.
parameter value is not saved in this way after
a change, the last value saved will be shown F6 - Log = Shows the error log menu
at reset. ESC = This key will return the user to the
previous screen
03:03-03 ©
Scania CV AB, Sweden, 2001-06:2 7
Governor Configuration: All speed
8 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03
Governor Configuration: Single speed engine
Changing parameters
In the single speed version, two operating speeds This applies if speed droop has been selected. For
can be adjusted. further information on switching between
- The two most common speeds for generating isochronous and droop operation, see installation
instructions.
sets, 1500 or 1800 rpm can be preprogrammed
by Scania. The minimum and maximum speeds There is an option for externally switching
are programmed at the same level when between low idle and operating speed with an
delivered from Scania. extra switch connected to the control unit.
- If both 1500 and 1800 rpm are required, this When the Run/Idle input on the control unit is
must be specified separately when ordering the switched to Battery-, the engine runs at idle and
engine. when it is switched to Battery+ the engine will
run at the required operating speed. See
If the speed needs to be switched, DIPswitch no. 6 installation instructions.
underneath the round black rubber cap on the
control unit must be changed.
- Normally the speed is 1800 rpm with the
switch in the ON position and 1500 rpm in the
OFF position.
- Values of between 0-20 % are accepted for the
speed droop. When the engine is delivered
from Scania, Map 1 is used to set the speed
droop. The basic value is 4.0%
03:03-03 ©
Scania CV AB, Sweden, 2001-06:2 9
Governor Calibration: All speed and single speed engines
Calibration procedure
The menu for calibrating the governor (A) gives
an option to calibrate and match the injection
pump to the control unit.
This calibration must be carried out when the
control unit or injection pump have been replaced.
- Make sure that power to the control unit has
been switched off.
- Remove the round, black, rubber cap over the
DIPswitches in the control unit. Set DIP switch
3 in the OFF position. See illustrations on next
page.
- Remove the red warning (Caution) label on the
control unit carefully, so that the label is not
damaged, to expose the calibration hole. After
the calibration the label should be put back to
cover the hole.
- Remove the cover over the COMM/DIAG
PORT and connect the computer cable with the
DEC end to this port.
10 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03
DIP switch 3
DIP switch 3
03:03-03 ©
Scania CV AB, Sweden, 2001-06:2 11
V7.0:
- Connect a multimeter with + (plus) to the
measuring pin (1) in the control unit and with –
(minus) to the brown cable marked TPSR
(A7=pin 7 in row A, cable C36-11) in the main
connector. See illustration below.
2 1
A
1
7 3
12
12
12 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03
V8.1:
- Connect a multimeter with + (plus) to the
measuring pin (1) in the control unit and with –
(minus) to the yellow cable marked OPSR
(B7=pin 4 in row B, cable C44-2) in the main
connector. See illustration below.
2 1 2 1
B
B
1
1
1
3
4 4
12
12
12
12
Control unit for single speed engines, Control unit for all speed engines,
version V8.1 version V8.1
03:03-03 ©
Scania CV AB, Sweden, 2001-06:2 13
20.3
14 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03
Important! Turn on the power to the control - Adjustment to reach these values is carried out
unit. Check that DIP switch 3 is in with calibration screws 2 and 3.
the OFF position. If there is a
Run/Stop switch, it should be set in - Repeat the procedure and check that the correct
the Run position. values have been obtained.
In the first screen (page 11), the control unit will Note: The control unit may switch to
ask for a value for "control rack travel". Shutdown during the calibration. By
turning off power to the control unit
- First read off the voltage value on the
momentarily, the function is reset to
multimeter with control rack travel = 0. The
normal and the calibration
voltage should be 0.454 (0.450-0.458) volts
procedure can be resumed.
DC.
- Then insert the value 20.3 (maximum control Summary of calibration data:
rack travel) and press Enter. Refer to
illustration on page 11. Control rack Voltage value
travel mm Volts DC
- The control unit now moves the control rack
twice to maximum and back to zero. At the 0 0.454 ± 0.004
same time Sending fuel rack travel .... is
displayed on the screen. 20.3 4.54 ± 0.04
- Read off the highest voltage value when the
control rack reaches maximum travel (twice).
- The voltage should be 4.54 (4.50-4.58) volts
DC.
03:03-03 ©
Scania CV AB, Sweden, 2001-06:2 15
Saving the calibration
When the calibration procedure has been - Set DIPswitch 3 in the control unit to the ON
completed and accepted, the message Calibration position (standard position).
has passed appears.
- Press ESC twice and confirm by pressing Y to
Save the calibration as follows: Exit.
- Press the space bar so that the text Enter choice
appears. Note: If an non-approved calibration is
saved, the engine cannot be started
- Save the required Calibration by pressing F2. until an approved calibration is
- Check that a green text is flickering in the carried out and saved.
bottom left hand corner, which confirms that
the save function is working.
16 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03
Calibration has failed Final check
- If the calibration values are outside the Turn off the power to the control unit and then
approved range, the message Calibration has turn on the power again.
failed will appear.
- Open the Calibration window and check the
- If this happens, the calibration procedure must values for Act F/B Offset and Act F/B Range.
be repeated from the beginning.
- Act F/B Offset should be within 81-102
CNT (RV=0).
Note: The calibration may fail even if the
voltage values are correct. In this - Act F/B Range should be within 921-942
case it is also necessary to repeat CNT (RV=20.3).
the calibration procedure.
Note: If the voltage values are correct but
the CNT values are outside the limit
values, the voltage values must be
changed to obtain the correct CNT
values and an approved calibration.
03:03-03 ©
Scania CV AB, Sweden, 2001-06:2 17
Possible error messages that can occur during calibration
• If the calibration fails although both high and • If the following text appears on the screen:
low voltage values are correct and the CNT Press any key to continue (blue text) and
values are within the tolerance range, Sending fuel rack travel.......0 (green text):
proceed as follows: - Press the space bar.
- Exit the DEC2 calibration program.
• If the following text appears on the screen:
- Turn off the main switch for powering the Press any key to continue (blue text) and
control unit. Calibration has failed (green text):
- Put DIPswitch 3 back in the ON position. - Press the space bar.
- Resume the calibration procedure from the • If the following text appears on the screen:
start on page 11. Would you like to (R)etry, (D)isable, or
(Q)uit (blue text) and Comm Error while
• If Shutdown occurs and the LED lights up on reading byte/word, data (e.g.) CCEF,
the control unit, momentarily turn off power status = 10 (green text)
to the control unit and then resume the
- Press the Q key and restart the calibration
calibration procedure.
procedure from the start on page 11.
• If the following text appears on the screen:
Press any key to continue (blue text) and
Error communication failure, Status:
(e.g.) E000 (red text):
- Press the space bar.
18 ©
Scania CV AB, Sweden, 2001-06:2 03:03-03