You are on page 1of 1

PUMP SIZING CALCULATION

Chesheets.com Tag No. P-101


Chemical Engineering Spreadsheets Description Feed Pump
Date 08-May-2017
User Input By CheSheets

Pipe Diameter - ID2


Flowrate 22.7 m³/h Pipe Length - L2 P2
Density 1000 kg/m³
P1
Viscosity 1.00 cP
Vapor Pressure 1.0 bar abs h1

Differential DP 2.41 bar


Differential Head 24.6 m Pipe Diameter - ID1
Hydraulic power 1.52 kw
Pipe Length - L1
NPSH available 3.74 m

Suction Condition Discharge Condition


Pressure P1 1.7 bar abs Pressure P2 2.1
Static Head h1 1.5 m Static Head h2 3.0
Equipment DP 0.34 bar Equipment DP 0.00
Misc DP 0.00 bar Misc DP 0.00

Piping Piping
Length L1 36.6 m Length L2 609.6
Pipe Diameter 3 inch Pipe Diameter 3
Sch/ Thick 40 Sch/ Thick 40
Pipe ID ID1 77.93 mm Pipe ID ID2 77.93

Roughness 0.04572 mm Roughness 0.04572

Fittings No. K DP Fittings No.


Elbows, 90LR 1 0.27 0.002 Elbows, 90LR 1
Elbows, 45LR 1 0.20 0.002 Elbows, 45LR 1
Tees, Thru 1 0.66 0.006 Tees, Thru 1
Tees, Branch 1 1.07 0.009 Tees, Branch 1
Ball Valves 0.20 Ball Valves
Butterfly Valves 0.34 Butterfly Valves
Gate Valves 1 0.14 0.001 Gate Valves 1
Globe Valves 5.32 Globe Valves
Check Valves 1 2.00 0.018 Check Valves
Plug Valves 0.34 Plug Valves
Pipe Entrance 1 0.50 0.004 Pipe Exit 1
0.042