You are on page 1of 3

MEA @ KIA PENG

Design Calculation

Sizes Sizes

1 Swimming Pool & Bubble Pool 1 Wading Pool


Area : 367.00 m2 Area : 117.00 m2
Depth : 1.20 m Depth : 0.45 m
Volume : 440.40 m3 Volume : 52.65 m3

Turnover Period Turnover Period

1 Adult pool : 6.00 hours 1 Wading Pool : 4.00 hours

Flow Rate Flow Rate

1 Adult pool : 1,223.33 liters / min Wading Pool : 219.38 liters / min

Filter Sizing Filter Sizing

Filter flow rate : 750.00 liters / min / m2 Filter flow rate : 450.00 liters / min / m2
Filter area required : 1.63 m2 Filter area required : 0.49 m2
800mm dia. provide : 0.50 m2 500mm dia. provide : 0.27 m2
Required no. filter : 4 numbers Required no. filter : 2 numbers

Balancing Tank Size Required Balancing Tank Size Required

Initial pump running : 5.00 mins Initial pump running : 5.00 mins
: 6,116.67 liters : 1,096.88 liters
Pool area surge : 0.03 m Pool area surge : 0.03 m
: 11,010.00 liters : 3,510.00 liters
Evaporation : 0.01 m Evaporation : 0.01 m
3,670.00 liters 1,170.00 liters
10% safety factor : 2,079.67 liters 10% safety factor : 577.69 liters
Total volume : 22,876.33 liters Total volume : 6,354.56 liters
: 22.88 m3 : 6.35 m3
PROJECT : Kia Peng Residences
SUBJECT: Swimming Pool Circulation Pump

Design Information Required Flow Rate = 1223.00 l/min


= 20.38 l/s

Design Flow Rate, Q1 = 21.00 l/s


Total Linear Pipe, L1 = 140 m

Using Hazen William Formula, friction loss, f = = 10.666*((Q1/(1000*C))^(1.85))*((D/1000)^(-4.87))


= 0.016 m/m

Head Loss through Linear Pipe, = f x L1


= 2.21 m

Head Loss through Fitting Head Lost Through Bends, Valve and Fittings
Quantity Fitting k value / fitting Total k value = k1 x v2 / 2g
12 Bend 0.45 5.40 = 1.81 m head
14 Tee 0.30 4.20
6 Gate Valve 0.12 0.72
2 Taper 0.30 0.60
1 Strainer 6.30 6.30
2 Flexible 1.00 2.00
1 Check Valve 6.00 6.00
0 Ball Float Valve 6.00 0.00
0 Water Meter 7.00 0.00
Total, k1 25.22

Total Head Require By Pump


Head Lost Through Linear length of Pipe = 2.21 Meter Head
Head Lost Through Bends, Valve and Fittings = 1.81 Meter Head
Sub Total = 4.0 Meter Head
Add safety Factor 10% = 0.40 Meter Head
Static Head gain(-ve)/loss = 10.50 Meter Head
Sand Filter = 5.00 Meter Head
Required Pump Head = 19.9 Meter Head

Summary
Pump Flowrate = 21.00 l/s
Pump Head = 20 m
PROJECT : Kia Peng Residences
SUBJECT: Wadding Pool Circulation Pump

Design Information Required Flow Rate = 219.00 l/min


= 3.65 l/s

Design Flow Rate, Q1 = 4.00 l/s


Total Linear Pipe, L1 = 100 m

Using Hazen William Formula, friction loss, f = = 10.666*((Q1/(1000*C))^(1.85))*((D/1000)^(-4.87))


= 0.012 m/m

Head Loss through Linear Pipe, = f x L1


= 1.17 m

Head Loss through Fitting Head Lost Through Bends, Valve and Fittings
Quantity Fitting k value / fitting Total k value = k1 x v2 / 2g
12 Bend 0.54 6.48 = 0.72 m head
11 Tee 0.36 3.96
6 Gate Valve 0.14 0.84
2 Taper 0.30 0.60
1 Strainer 7.56 7.56
2 Flexible 1.00 2.00
1 Check Valve 7.20 7.20
0 Ball Float Valve 7.20 0.00
0 Water Meter 7.00 0.00
Total, k1 28.64

Total Head Require By Pump


Head Lost Through Linear length of Pipe = 1.17 Meter Head
Head Lost Through Bends, Valve and Fittings = 0.72 Meter Head
Sub Total = 1.9 Meter Head
Add safety Factor 10% = 0.19 Meter Head
Static Head gain(-ve)/loss = 10.50 Meter Head
Sand Filter = 5.00 Meter Head
Required Pump Head = 17.6 Meter Head

Summary
Pump Flowrate = 4.00 l/s
Pump Head = 18 m