You are on page 1of 79

Circuit Breakers

Gerard John M. Mendoza, REE


Technical Sales Engineer
Life Solutions Group
Panasonic Manufacturing Philippines Corporation
Introduction

A circuit breaker is an automatically operated electrical switch designed to protect an


electrical circuit from damage caused by excess current from an overload or short circuit.
Its basic function is to interrupt current flow after a fault is detected.

Retailer List – as of Sept 27th


-- Wikipedia

2 PPH - Eco Solutions Team


Introduction

Circuit breaker is a mechanical switching device capable of making, carrying and breaking currents
under normal circuit conditions and also making, carrying for a specified duration and breaking currents
under specified abnormal circuit conditions such as those short circuit.

--
International Electrotechnical
Commission

3 PPH - Eco Solutions Team


IEC Standard

IEC 60898-1

This part of IEC 60898 applies to ac circuit breaker for operation at 50Hz, 60Hz, or 50/60Hz, having a
rated voltage not exceeding 440V, a rated current not exceeding 125A and a rated short-circuit
breaking capacity not exceeding 25000A or 25kA.

IEC 60947-2

This part of IEC 60947-2 series applies to circuit breakers, the main contacts of which are intended to
be connected to circuits, the rated voltage of which does not exceed 1000V ac or 1500V dc.

4 PPH - Eco Solutions Team


INTERPRETATIONS ON STANDARDS | IEC and PNS Relation
INTERPRETATIONS ON STANDARDS | Test Parameters

6 Panasonic Eco Solutions


FINDINGS and RECOMMENDATIONS|

7 Panasonic Eco Solutions


FINDINGS and RECOMMENDATIONS|

8 Panasonic Eco Solutions


IEC Standard

Pointers:

1. Devices mounted inside a panelboard where only skilled or instructed persons do have access the
short circuit values acc. IEC 60947-2 could be used.
2. Devices can be operated when the doors are closed and the panel is accessible by everyone the
short circuit values acc. IEC 60898-1 should be used.
3. The panel doors can be opened by anyone. (IEC 60898-1)
4. Only skilled or instructed person can operate the device. (IEC 60947-2)
5. Unskilled or untrained person can operate the device. (IEC 60898-1)

9 PPH - Eco Solutions Team


Risks of Electrical Currents

Electricity has a lot of advantages, but there are also a lot of risks,

a. Fire
- Injuries
- Damage to properties
- Death
b. Electric Shock
- Injuries/ Harm to human health
- Death
c. Malfunctions (e.g. Equipment, Machines)
- Accidents
- Interrupted Work
- Damage to Equipment

Strict installation rules have been set up by IEC.

10 PPH - Eco Solutions Team


Risks of Electrical Currents

Damage to Equipment

• Certain electrical equipment may be damaged or destroyed by high currents.


• Case for motors during prolonged operation above rated load and cables if too many devices
are connected.
• Overcurrent provokes excessive temperature rise to conductors and may lead to insulation
breakdown and the flow of an earth fault current.
• This may remain at a low level, difficult to detect or rapidly degenerate into short-circuit and
provoke major damage.

11 PPH - Eco Solutions Team


Risks of Electrical Currents

Electric Shocks

• Protection measures against electric shocks are described in


IEC 60364-4-41.
• The physiological reactions of the human body to current flow in amperage levels demonstrate in
IEC 60479-1.
• Given the current levels considered dangerous, a maximum permissible value of 30mA is
considered safe.

12 PPH - Eco Solutions Team


Risks of Electrical Currents

Fire Hazards

84% of fire incidents in the Philippines are because of electrical


faults.

1. Improper electrical installation


2. Old installations (wearing of insulations)
3. Substandard, low quality electrical products

13 PPH - Eco Solutions Team


Risks of Electrical Currents

Summary

Fire Electric Shock Damage to Equipment

Source of danger • Insulation faults • Absence of • Outdated insulation.


• Incorrectly designed protective • No proper/
protective/wiring devices measures. preventive
• Damaged cables and • Improper work maintenance
loose connections. practices.
• Insulation faults.

14 PPH - Eco Solutions Team


Protection Solution

15 PPH - Eco Solutions Team


Protection Solution

Product Lineup
Miniature Circuit Breaker (IEC 60898-1)
• Rated Current: 6 – 63A
• Rated Breaking Capacity: 4.5/6/10kA
• No. of poles: 1P, 2P, 3P, 4P

4.5k 6kA 10kA


A

In (A)
6 8 10 13 16 20 25 32 40 50 63

1P 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇

No. of 2P 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇
Poles 3P 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇

4P 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇

16
Protection Solution

Panasonic MCB

Product Overview:
① Load Terminal
1. Load Terminal
2. Terminal Plunger
3. Arc Chute Plates
④Handle
4. Arc Runner
⑤Terminal・
Plunger 5. Handle
6. Fixed Rivet

⑥fixed Rivet

②Arc Plate ③Arc Runner

17 Panasonic Eco Solutions


Protection Solution

Compared part Panasonic


Compatible both for Needle-Type
①Load Terminal and Fork-Type

needle-type fork-type

②Arc Plate Improved the reliability of Icu


by using 13 Arc chute plate

③Arc Runner
Improved the reliability of Icu
by curving shape

④Handle Clear visibility of ON/OFF display


for better function

⑤Terminal Conforming to RoHS


Plunger

⑥Fixed Rivet Fixed 6 points by Copper rivet.


Strong hardness and High quality

18 Panasonic Eco Solutions


Protection Solution

Product Lineup
Residual Current Circuit Breaker (IEC 61008-1)
• Rated Current: 25, 40, 50, 63A
• Rated Breaking Capacity: 10kA
• No. of poles: 1P+N, 3P+N

In (A)

25 40 50 63

2P 〇 〇 〇 〇

No. of Poles
4P 〇 〇 〇 〇

19
Protection Solution

Product Lineup
Residual Current Circuit Breaker with Overcurrent (IEC 61009-1)
• Rated Current: 6 – 63A
• Rated Breaking Capacity: 6kA
• No. of poles: 1P+N, 3P+N

In (A)

6 10 16 20 25 32 40 50 63

2P 〇 〇 〇 〇 〇 〇 〇 〇 〇

No. of Poles

4P 〇 〇 〇 〇 〇 〇 〇 〇 〇

20
Panasonic Fire Alarm System
2019

21

www.panasonic-fire-security.com
53 Years in the Fire Alarm Business with almost 15,000 Building Installed

22
Product Origin
Aspirating Systems in Norway
Control panels in Sweden

Detectors in Japan
Manual call points in UK

Bases in China

24

www.panasonic-fire-security.com
Complete Product Portfolio

Panasonic offers a complete and highly competitive product portfolio, fully EN 54 and
VdS approved
 Control Units for all sizes of installations
 State of the art addressable detectors
 Wireless System
 Aspirating System
 Explosion Proof / Intrinsically Safe System
 Waterproof (IP 67) Detectors
 Addressable COM loop units and accessories
Highest Performance
 Conventional units Requirements 26

www.panasonic-fire-security.com
HEALTHCARE FACILITIES EDUCATION TRANSPORTATION

27

INDUSTRIAL DATA CENTER LOGISTIC


Control and Indicating Equipment – EBL 512 G3

 4 COM loops
 1020 COM loop addresses, max 512 alarm points
 Up to 30 panels in a TLON network=> 15k alarm points
 Network in Multi-master configuration
 Redundant network communication for highest security
 Remote access via any internet connected terminal
 Wide Enclosures for Batteries
 Integration with conventional systems.
28

www.panasonic-fire-security.com
Control and Indicating Equipment – EBL 128

 One COM loop


 255 COM loop addresses
 Remote access via any internet connected terminal
 Wide Enclosures for Batteries
 Integration with conventional systems.

29

www.panasonic-fire-security.com
Display Unit
 Selectable Feature as:
 Presentation Unit
 Fire Brigade Panel
 Alert Annunciation Unit
 Color Touch Screen 10.1”
 Multi-Language Support
 Up to 30 units per Control Panel
 1200 m maximum farthers unit
30

www.panasonic-fire-security.com
Addressable Detectors
 State of the Art Detectors for highest Safety
 Advanced Mode for selected detectors capable of reducing nuisance alarm by 46%
 Automatic Service Signal to mimize maintenance Cost.
 Sensitivity Modes and Algorithms programmable via EBLWin

4401 3308 3309 4400 4402 3309


Analog Photoelectric Analog Heat Enclosed Analog Heat Analog Multidetector Analog Analog Mult Detector with
Smoke Detector Detector Detector Multidetector with Isolator 31

CO
www.panasonic-fire-security.com
Conventional Detectors

4375 4376 4318 4452


Heat Detector 60ºC Heat Detector 80ºC Combination Heat Detector Photoelectric Smoke Detector
Class A2S Class B S Class A1 R
32

www.panasonic-fire-security.com
33
False Alarm Proof – Reduction of Mesh from 0.5mm to 0.3mm
18 months long comprehensive investigation showed that 78 % of all nuisance alarms were caused by
dust or insects

Dust ø 0.5 mm String of Spider ø 0.5 mm Smallest Insect ø 0.5 mm

34

www.panasonic-fire-security.com
Advanced Mode – Self Diagnosis
To eliminate the need for redundant sensors the detectors perform self-diagnosis
and reports any deviation as a fault in the Control Unit.

• Data Flash in CPU


• IR – LED
• Smoke Detection IC
• Thermistor

35

www.panasonic-fire-security.com
Advanced Mode - Learning
A special learning function will automatically adapt to the Fire Alarm Algorithm suitable for the
conditions in the area where the detector is mounted. Smoke/Steam Mode

Clean Mode Normal Mode

Cooking/Welding Mode

36

www.panasonic-fire-security.com
Sensitivity compensation and Service signal

Week average
value

38

www.panasonic-fire-security.com
Analog Detectors – Outstanding Reliability

 Produced in a fully automated factory in Japan


 Every detector is tested twice with real smoke from fire
 No statistical test methods are accepted
 If No Pass, the detector is scraped and not repaired
 Each detector is individually calibrated for optimal
performance
Detector Testing

39

www.panasonic-fire-security.com
Addressable Wireless System
 Ideal in buildings where it is difficult to hide cables and where extensions are required.
 170m transmission Range | 868MHz – 869MHz | 10mWerp | TDMA/FSK | 6yrs Battery
 High Flexibility: Up to 4 Base Station per COM loop and up to 16 wireless units per station

4611 4614 4620 4613


Photoelectric Smoke Detector Manual Callpoint Base Station Sniffer Tool 40
with Sounder
www.panasonic-fire-security.com
Addressable Manual Activation / Deactivation Devices

4433 4439 4445


Addressable Manual Call point IP66, Enclosed addressable Manual Addressable Local Alarm
with isolator Call point with isolator Acknowledge Unit
41

www.panasonic-fire-security.com
Addressable Audio and Visual Notification Devices

4480 4481 4482 4487 2218


Addressable Wall VAD Addressable Ceiling VAD Addressable VAD with siren Addressable Siren External Indicator (LED)
with isolator with isolator and isolator With isolator

42

www.panasonic-fire-security.com
Interfacing | Monitoring | Expansion Modules

4461 4462 4464 4585


Multipurpose I/O Unit Dual Input Unit 2 Voltage Output Board COM-Loop Repeater
 Built-in isolator  Built-in Isolator  Board for external supply  350mA Loop

 1*Zone line input  2*Monitored inputs  Auto Addressing  Auto Addressing

 1*Monitored input  IP65 housing  2 Monitored Voltage Output  Up to 16 per CIE

 1*Opto coupler input  1 Special Voltage output for  Up 2km extra loop
fire door closing
 2*Relay outputs
 1 Relay Output
 IP65 housing 43

 1 input
www.panasonic-fire-security.com
Detector Bases

2324 3312 3379 4412F 4383


Conventional Base Analog Base Addressable Sounder Base Base for Isolator Type Light Indicator Base Filler

44

www.panasonic-fire-security.com
Addressable loop units – Power supply

• 230 V AC -> 24 V DC (2.1 A)


• 4 A at fire alarm
• Supervised from Control unit
• Mains
• Charging
• Battery
• 7.5 Ah batteries inside the box
• Up to 60 Ah in external box
3366
Addressable external power supply
230 V AC – 24 V DC
45

www.panasonic-fire-security.com
Explosion Proof and Intrinsically Safe (IS) Devices
 Analog and Conventional Type Detectors
 IS Barrier unit and Galvanic Isolator Modules for panel integration..
 EX Class: II 1G Ex ia IIC T5 Ga
 Up to IP 66/67

2840 2841 2842 2842 6295 to 6298


IS Analog Photoelectric Smoke IS Analog Heat Detector Conventional IS Manual IS Enclosed Heat Derector
IS Barrier Unit
Detector Call Point 46

www.panasonic-fire-security.com
Flame Detectors - Talentum

• Compliant with EN54-10 Class 1 (25 m)


• Certificates from VdS and LPCB
• 3 different models
• IR3
• UV/IR2
• IR3 – IS (Intrinsically Safe)

47

www.panasonic-fire-security.com
Aspirating Detectors - Elotec
 Ideal for Early detection of Smoke and Fire in:
 Heavy Industries
 Agriculture
 Clean rooms
 Server Rooms
 Modules for different types and classification of
detection.
 Software based programming and commissioning.
 Can be configured as control panel Fire Alarm.
48

www.panasonic-fire-security.com
Beam Detectors – Fireray 50R/100R
 Single Compact Housing
 Working Optical Path for Detector Alignment
 Two Models 50m and 100m version
 12 – 24VDC Operation
 Low Current Consumption
 Robust Construction
 Approved to EN54:12 and UL268

49

www.panasonic-fire-security.com
Commissioning
 User Friendly Interface
 Auto – Addressing Function
 New installation

 Extension

 Replacing detectors

 Generate SSD (Site Specific Data)


 Simulation of Wire Length Capacity
 Computation of Battery backup rating
based on standby requirements
52

www.panasonic-fire-security.com
EBL512 G3 system overview
Modbus

54

www.panasonic-fire-security.com
EBL Graphics

• Graphic presentation SW for EBL Fire Alarm


Systems
• Disable detectors or zones directly via the
graphic interface
• Automatic reenable
• View live camera feeds (onvif)
• Alarm texts and emergency instructions for
each alarm point
• Real time sensor values available
• Zoom and pan
55

www.panasonic-fire-security.com
EBL Web

 Connect remotely to an EBL System


 Secure log in with different user levels
 E-mail notifications at predefined events,
e.g. service, fault, alarm etc
 Presentation of:
 Fire Alarm
 Pre-warning
 Fault
 Disablement

56

www.panasonic-fire-security.com
EBLWeb Monitor

• Ideal for distributed installations


• Presents all information in one
browser window
• Map and list view available
• Simple configuration with
included tool
• Requires EBLnet license and
one extra WEB server 57

www.panasonic-fire-security.com
Linear Heat detection - Fiber Optics

DTS utilizes the Raman effect to measure temperature. An


optical laser pulse sent through the fiber results in
some scattered light reflecting back to the transmitting
end, where it is analyzed. The intensity of the Raman
scattering is a measure of the temperature along the
fiber.
The position of the temperature reading is determined by
measuring the arrival timing of the returning light pulse
similar to a radar echo. 59

www.panasonic-fire-security.com
Advantages
Safe to use in
hazardous zones

Immune to EMI

Maintenance free
Cable is immune to for decades
harsh environments

Deployable in Entire cable length


difficult access areas monitored in real time

Easy to install and Thousands of


integrate measurement points per zone

60

www.panasonic-fire-security.com
Zone Concept

Zone 2

Zone 3
Zone 4

Zone 5

Zone 6

Zone 7
Zone 1

320
zones

61

www.panasonic-fire-security.com
Compliant Configurations (EN54-22, VdS)

63

www.panasonic-fire-security.com
Wide area of applications

Traffic Tunnels Cable Trays Parking Garages Production Halls

Utility Tunnels Coal Storages Floating Roof Tanks Subway Station


Rail Tunnels
• Warehouses / Cold Storage • Mills
• Composting Facilities • Mining
• Paint / Chemical Production • Bus Duct Monitoring / Data
Conveyor Belts Center
• (Wooden) Roof Structures 64

• Suspended Ceilings
www.panasonic-fire-security.com
EBL Benefits
 Lower total cost of ownership
 Reduction on wiring cost
 Service Alarm Signal
 Auto – Addressing Function

 False Alarm Proof system


 Artificial Intelligence
 Unique Detector Mesh

 Integrated System for Alarm and Monitoring


 Security Management Systems
 CCTV Integration
 EBL Web
 EBL Graphics
 EBL App
65

www.panasonic-fire-security.com
Product Overview

66

www.panasonic-fire-security.com
LISTINGS

67

www.panasonic-fire-security.com
What we can offer:
• Full System Proposal (Supply + Install)
• Fire Alarm Design
• Full CAD Layout
• Spec-in Assistance
• Estimation for Aspirating Systems
• Installation supervision
• Training / Orientation (Pre/Post)
• Technical Support
68

www.panasonic-fire-security.com
PROJECT REFERENCE - LOCAL

69
70

www.panasonic-fire-security.com
71

www.panasonic-fire-security.com
JG Summit Petrochemical Corporation – Batangas

 Ongoing Installation:
 Chemical Area
 Warehouse 1 and 2
 Laboratory
 3 Control Panels EBL512
 Combination of Addressable and
Explosion proof system
 Integration with Security Management
System via Modbus 72

www.panasonic-fire-security.com
Bridgestone Factory - Cavite

 New Production Facility


 Installed Fully Addressable
EBL512 System
 Expolosion proof detectors on
hazardous areas.
 Phase 2 rehabilitation to old facilities
and production plant.

73

www.panasonic-fire-security.com
EMI-Yazaki Manufacturing Plant, Cavite

 Integration with OLD Conventional Type


Fire Alarm System
 6 Conventional Control Panels
converted into 1 Addressable Panel.
 70 Zones with ~ 500 Detectors.
 Phase 3 on going – Conversion to Fully
Addressable System and TLON
connection.
74

www.panasonic-fire-security.com
PEPSI-COLA Manufacturing Plant, Muntinlupa

 FDAS Installation to New Warehouse


and Building Expansion.
 EBL128 System Installed.
 ~ 100 Detectors and Accessories.
 High Ceiling installations using beam
detectors.

75

www.panasonic-fire-security.com
76

www.panasonic-fire-security.com
77

www.panasonic-fire-security.com
78

www.panasonic-fire-security.com
SM Legazpi Terminal – Bicol

 FDAS Installation to Transport terminal


and exterior area.
 EBL128 System Installed.
 3 days installation and turnover.
 Next phase integration to main building
conventional system.

79

www.panasonic-fire-security.com
OTHER SOLUTIONS

85
| Residences Switching Solutions

STANDARD SWITCHING SMART SWITCHING


| Choose among our | Achieve total Smart Home
different series that matches Solution with our fully
design requirements from automated system control
middle to high end projects. via Touch Panels or mobile
app.
| Hotel Devices Solutions
COLOR AVAILABILITY
INDICATOR CONTROL EL GUARD OUTLET (GFCI)

Also available in Black/Silver color.

DUAL VOLTAGE QUALITY AND SAFETY


SHAVERS
OUTLET

KEYCARD SWITCH

Full metal framing and Lever type wire release.

NAMING OPTIONS
ROOM
INDICATOR
MULTIPLE DEVICE PORT > |HOTEL
DOOR
CHIME
Optional change of Brand name to Hotel Name

Featuring:
| HOSPITALITY | Lighting
Spot Light
| Fixed or Adjustable type Low
glare spotlight for corners or near
wall installations.

Panel Light
| Ceiling or Wall
Mounted Surface Panel
Lights
Downlights
| Circular and Square type Low UV radiation
downlights for main room lights.

Soft Edge Downlights


| Circular seamless innovative design that
softly blends into ceilings.

Panel Lights
| Circular and Square type low height (~3cm)
Panel light with models capable of tri-color
changing for installations with low ceiling height
provisions.

Strip Lights
| Indoor and outdoor type strip lights
suited for room and lobby cove
lighting.

Ceiling Center Lights


| Ceiling mounted decorative center
lights featuring models with remote
control for color change and dimming..
| COMMERCIAL | Lighting

Full Color, High power Flood


Light
| Special design RGB triangle arrangement and
multi LED chip placement to ensure a beautiful
color mix with no unevenness.
Strip Lights
| Indoor and outdoor type strip
lights suited for room and lobby
cove lighting.

Base Light
Downlights | New deep type recess
| Circular and Square type Low UV mounting square LED
radiation downlights for main room luminaires, anti-glare diffuser
lights. and separate energy efficient
driver

iD Series Linear
Lighting
| Energy efficient Linear
lighting with 190lm/watt.

Downlights
| Recess mounting circular LED
luminaires with die-cast aluminum
housing in white powder coating finish,
Specially designed heat sink and
separate efficient electronic driver,
Track Light
| Aesthetically designed LED
track light luminaires. With
high CRI
| Ventilating Fans Bathroom
Series
Compact & Stylish

Residential Indoor Air Quality Solutions Excellent Exhaust in moisture & smell
Easy Maintenance

In-line Cabinet
High Capacity & Static pressure
Compact Size

Ceiling Mounted
Super Quiet
Easy Installation
Energy Saving

Air Curtain
2-speed selection (Hi/ Lo)
Hand Dryer
Cooling Retention Kitchen Series Quick Drying

Odor / Insect / Dust Proof Anti bacterial material


Easy Clean Coating
Super alleru buster
Oil Collecting – Environmental Friendly
Perforated Aluminum Filter - Durable
Solar The Power of Partnership

PROJECT REFERENCES

High Efficiency 135 Kw Chiyoda Factory

42 years in PV panels
Stability & Reliability 240
240watt
wattpeak
peak 325 watt peak
0.0035% failure rate out of
3.94 M modules sold 19.0 % Efficiency 19.4 % Efficiency
50Kw Seminary 28 Kw Zuellig Bldg
50 years in Philippines Weight 15 kg Weight 19 kg
Company Stability
100 years globally Area 1.26 sq mtr Area 1.68 sq mtr

Warranty 10 years Product Warranty


25 years Performance Warranty

High Quality
5

500 Kw Fiesta World Mall – Batangas


Thank You!

92

www.panasonic-fire-security.com