You are on page 1of 17

Product Release Letter

AVEVA Everything3D™ 2.1.0 Fix.3


Partial Fix Release 52486
Windows 7 / Windows 8.1
This letter introduces and describes this release, which is supported on the indicated platform(s).

This Release Contains


A partial release of AVEVA Everything3D™, which upgrades the full release 52421 AVEVA Everything3D™
2.1.0.
The separately licensed products or product components installable from or upgraded by this release are
as follows:
Product Core
Product Code Product Name
Version Version
V00FN201 AVEVA Everything3D™ 2.1.0 1.2.2
V00FN232 AVEVA Catalogue™ 2.1.0 1.2.2

Prerequisite for this Release (Operating System)


A 64 bit operating system is required for the installation of AVEVA Everything3D™ 2.1.0 and for the
visualisation and use of laser data in the application.

 Windows® 7 Professional or Enterprise + Service Pack 1*1.


 Windows Server 2008 R2 + Service Pack 1.
Required Operating System  Windows® 8.1*2.
 Windows Server 2012 R2.
 Microsoft .NET Framework 4.0 (supplied)*3.

Build Operating System  Windows Server 2008 R2 + Service Pack 1.

*1 Please note that a Windows Platform Update (Windows 7 SP1 and Windows Server 2008 R2 SP1) is a pre-requisite for accurate 2D rendering (for
example Text graphics) in the 3D canvas (http://support.microsoft.com/kb/2670838 ).
*2 AVEVA does not support the installation of AVEVA E3D 2.1 software and\or Projects on to disk volumes with Short\8.3 file name format disabled.
Please ensure that Short\8.3 file name format is enabled on all relevant volumes before installation. Please refer to Knowledge Base item 5702 for
further details.
*3 AVEVA E3D 2.1.0 has been tested with Microsoft .NET Framework 4.0 with the following fix: http://www.microsoft.com/en-
us/download/details.aspx?id=3556. This fix is mandatory for the use of the Design in Context Feature.
Microsoft .NET Framework 4.5 Fix 2 has been tested with AVEVA E3D 2.1.0. The fix release is required to ensure the correct visualisation of the
AVEVA E3D Draw 2.1.0 print dialog.

For further information please contact your local AVEVA support office, which can be found at support.aveva.com

This document has been prepared and approved by the following:


Job Title Name
Product Manager Stephen Burrows
Test Manager Vaseem Jameel
Head of Product Neale Morris
TPS Manager Semra Hamitogullari

File: d52486
Last saved: 4-May-2016  Copyright 2016 AVEVA Solutions Limited Page 1 of 17
Product Release Letter
Please note that recommended/supported hardware and software configurations are constantly subject
to review; please consult the AVEVA support web pages for the latest recommendations.

Prerequisite for this Release (Products)


AVEVA Licensing™
 AVEVA Licensing 2.0.0 or later and an appropriate License File.
Notes:
1. AVEVA Everything3D™ does NOT work with AVEVA Flexman.
2. If upgrading from AVEVA Licensing System 1.1.1, please install Fix release 1.1.1.3 in order to correct
an uninstall defect in that release. Once this has been done version 1.1.1.3 can be uninstalled and
replaced with later versions.

AVEVA Client Cache Service™


 To ensure the performance benefits presented by the AVEVA Cache Service, which is installed with
AVEVA Everything3D™, Microsoft Message Queuing (MSMQ) must be enabled. This is achieved using
the Windows Components feature of Windows Control Panel > Add or Remove Programs.
For full details, please refer to the AVEVA Everything3D™ 2.1.0 Installation Guide.

Microsoft® Software
 AVEVA E3D 2.1.0 has been verified with Microsoft® Office 365.
 Microsoft Office 2010 (and later) is required for some functions:
1. Optimum operation of the AVEVA Design Platform GUI requires Arial Unicode MS font, supplied
with Microsoft Office and also with Microsoft Office Visio.
2. Microsoft Office Excel import requires “.NET Programmability Support” enabled when Office is
installed. This can be found under “Advanced customization of applications” and installs the
Microsoft.Office.Interop.Excel.dll; without this, Excel import will not work.
 Microsoft Office Visio 2010 (Standard edition, 32-bit) is required for AVEVA Schematic Model Viewer.

Compatibility

For full compatibility details, and for information about AVEVA E3D 2.1.0 compatibility with any later
versions, please refer to the compatibility matrix.

A full and up to date compatibility matrix can be found at compatibility.aveva.com/matrix.

The following AVEVA products are compatible with AVEVA Everything3D™ 2.1.0.

 AVEVA Administration™ 1.4.0.


Note: This release supersedes all previous AVEVA Administration versions delivered with other AVEVA
products.
 AVEVA Applications Service™ 2.1.0.
Note: For customers who use AVEVA E3D Insight™ 2.1.0: AVEVA Applications Service 2.1.0 or higher
must be used. Earlier versions are incompatible.
 AVEVA Bocad™ 2.2.1 & 2.3.0.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 2 of 17


Product Release Letter
 AVEVA Catalogue™ 2.1.0.
 AVEVA Client Cache Service™ 1.0.5.
 AVEVA Clash Manager™ 14.1.0.
Note: This is a planned compatibility on the release of the forthcoming AVEVA Clash Manager product.
 AVEVA Design Checker™ 1.1.0.
 AVEVA Diagrams™ 14.1.0 (Fix Release 4).
 AVEVA E3D Documentation™ 2.1.0.
 AVEVA Electrical™ 12.1.3 (Fix Release 8).
 AVEVA Engineering™ 14.1.1 (Fix Release 4).
 AVEVA Global Server™ 3.2.1.
Note: Includes separately licensed products AVEVA Global Hub and AVEVA Global Satellite.
 AVEVA Hull & Outfitting™ 12.1.4 & associated products (Fix Release 28).
 AVEVA Instrumentation™ 12.1.3 (Fix Release 6).
 AVEVA Integration Service 1.3.0.
Note: This is the primary route for compatibility with AVEVA P&ID™ 12.1.2 (Fix Release 9). The service
also supports compatibility with AVEVA Electrical™ 12.1.3 and AVEVA Instrumentation™ 12.1.3.
 AVEVA NET Workhub & Dashboard™ 5.0.1.
 AVEVA PDMS™ 12.1.4 & associated products (Fix Release 28).
 AVEVA PDMS-VPRM Gateway™ 5.6.0.
 AVEVA Plot Utilities™ 12.1.5.
 AVEVA Pipe Stress Interface™ 2.1.0.
 AVEVA PML Publisher™ 2.2.0
 AVEVA Review™ 12.2.0 (Fix Release 10).
 AVEVA Shared Services™ 3.3.0.
 AVEVA Structural Analysis Interface - SP™ 3.1.0

The following LFM products are compatible with AVEVA Everything3D™ 2.1.0:
 LFM Server™ 4.4.0.

Supersedes
This release supersedes Release 52472– AVEVA Everything3D™ 2.1.0.2.

Install
Please download the release (52486.zip) and run the product install (Folder E3D2103, E3D2.1.0.3.exe)
following the instructions.

Sample Data
Sample projects are available here: AVEVA Everything3D™ - Projects.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 3 of 17


Product Release Letter
The AVEVA sample projects are regularly revised. Please check the AVEVA Support Site (AVEVA
Everything3D™ Fix Release History) frequently for updates.
AVEVA Laser Sample Data 1.1 is available for use with AVEVA E3D 2.1.0 for the purpose of familiarisation
with the extensive laser functionality available, including the new AVEVA HyperBubble™ technology. The
data may be downloaded here: AVEVA Laser Sample Data.

Documentation
The AVEVA E3D 2.1 documentation includes the AVEVA Administration, AVEVA Catalogue and AVEVA
Global product user guides.
Documentation is available online so that it may be continually updated and remain current for any new
functionality introduced through the life of the product. AVEVA Documentation 2.1 may also be
downloaded separately for local installation here: AVEVA Documentation 2.1.

First Release
This product release is first available on the AVEVA support website support.aveva.com as AVEVA
Everything3D™ 2.1.0.3, release number 52486.

List of Enhancements
AVEVA Everything3D™ (E3D™) is the primary 3D design product from AVEVA covering the needs of Plant
industries. The release also introduces the capability to interact with Hull models produced in AVEVA
Marine.

AVEVA E3D 2.1.0 provides a platform to enable lean construction principles to be adopted, increasing
quality and speed of execution throughout the entire project. This is achieved through advanced usability
for all design tasks, improving productivity by utilising latest technologies and best in class User Experience
to enable innovative and ever more efficient project execution processes.

The product includes optimal integration with AVEVA Engineering & Schematics and new innovation with
Laser data, utilising the Living Point Cloud capability of AVEVA HyperBubble™. Powerful 2D drafting also
allows the inclusion of Laser data, driving down the need to remodel existing Digital Assets.

The AVEVA E3D 2.1.0 release includes the following general functional enhancements:

 General Model Interactions e.g. the PowerWheel, PowerCompass and Properties Grid.

 A new Structural application (Sections and Plates).

 A new Supports application.

 Improved integration of Laser Data, including the introduction of the HyperBubble™


technology and the ability to included Laser data in Drawings.

 Integration with AVEVA NET™ through the Design in Context feature.

 Visualisation of Hull Data in Model and Draw modules.

 General Draw Improvements (incl. Hull Symbolic Views).

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 4 of 17


Product Release Letter
 Integration with AVEVA E3D Insight™ and the ability to Comment a design.

 Piping Improvements (incl. Integrator & Sloping Pipes).

 Please refer to the AVEVA Everything3D™ 2.1.0 User Bulletin for extensive information on features
introduced at AVEVA E3D 2.1.0.

 Where migrating to AVEVA E3D 2.1 from AVEVA PDMS or Hull & Outfitting 12.1.SP4 please consult the
AVEVA Everything3D™ 2.1.0 Migration & Interoperability Guide for guidance on specific data
considerations.

This fix release includes the following functional enhancements:


Multiport Valves.

The IsoDraft module is now able to produce isometrics containing multiport valves and instruments. Such
valves are typically used in the dairy and food industries.

Users should note the generic type is INST to allow multi-connection


reference array.

Multiport Valves are either single, double or triple bodied in a tier of varying
orientation.

As an addition to ACP project MASTER/PIPECATA database a new CATA


/EXAMPLE-GEA-TUCHENHAGEN-CATA has been included with examples of
GEA Tuchenhagen multi-port dairy and food industry valves

To use these or other manufacturer valves/instruments of a similar design,


users should refer to the Isodraft reference manual.

There are 18 SKEY variations available – the below illustrates an example of a Three-Level Multiport Valve.

In regards to P-Points the following should be noted:


 Instrument dials can have a P3 with an unset bore for orienting the dial. This p-point will normally
be positioned perpendicular to the dial face, on the dial axis. A message will be output near the
component showing the orientation of P3.
 P-Point 11 is the Spindle attachment point and its PURP attribute should be set to ‘SPIN’.
 Multiport Valves may have up to 2 flushing/draining connections:
o These must be P-Point 9 and P-Point 10.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 5 of 17


Product Release Letter
o The isometric will only show a symbolic line and a note CONT TO ”name” for each
connection.
o There will be no materials or isometric representation of the branch connection to these
points.

 For further information please refer to the IsoDraft Reference Manual: INST Symbol Keys and Symbol
Key Reference Index.

Consolidated from previous fix releases:

AVEVA Everything3D 2.1.0.2, Release No. 52472.


AVEVA Bocad Steel Interface.

The AVEVA Bocad Steel Interface is an integral part of AVEVA E3D 2.1. The interface facilitates the transfer
of structural steel data between AVEVA E3D 2.1.0 and AVEVA Bocad Steel (2.1.1 onwards). The interface
makes allowance for the introduction of the new Structural Catalogues at AVEVA E3D 2.1.0 and the use of
GENSEC elements.

The AVEVA Bocad Steel Import and Export tools are located within the Import and Export groups in the
TOOLS tab.

New mapping files have been made available; one for each standard of the new AVEVA E3D 2.1 Structural
Catalogue, to be used with the most recent AVEVA Bocad Catalogue (2.2.1 and 2.3 onwards). These
mapping files are required to be customised where the AVEVA Bocad Catalogue has been altered or a
differing standard has been used in a project.

To aid the mapping process a new tool is available to


create or customise mapping files. The AVEVA
Structural Map File Converter is available from the
AVEVA Bocad Steel Import and Export forms via the
Control menu option Map Converter.

The standard P-lines that exist for the profiles within the new AVEVA E3D 2.1 Structural Catalogue are
sufficient to use the AVEVA Bocad Steel Interface - additional P-lines previously used are no longer
required. It should be noted that within the new Structural Catalogue ANGLE profiles have a new

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 6 of 17


Product Release Letter
orientation convention in line with other products in the market. This is managed by an internal
orientation mapping file.

 It is important to note that the AVEVA Bocad Steel Interface provided within AVEVA E3D 2.1 is
compatible with the ‘old’ Profile catalogue and P-lines as long as the specific P-lines have been
installed.

In regards to the import process, it should be noted that only GENSECs will be created at import due to
SCTN elements being no longer used by the AVEVA E3D 2.1 Structural application.

 Please refer to the AVEVA E3D 2.1 User Documentation for further information regarding the
administration and use of the AVEVA Bocad Steel Interface in AVEVA E3D 2.1.

AVEVA SDNF Interface.

The AVEVA SDNF interface facilitates the transfer of structural steel data between structural applications
using the SDNF neutral format file. The interface makes allowance for the introduction of the new
Structural Catalogues at AVEVA E3D 2.1 and the use of GENSEC elements for linear structural elements.

This SDNF interface is available in the Import and Export group of the TOOLS Ribbon tab.

A new mapping file format has been introduced (BLOCK). This will increase the speed of search within the
mapping file. As seen with AVEVA Bocad Steel Interface, a new tool is available to create or customise
mapping files with this new format – the AVEVA Structural Map File Converter. The tool is available from
the SDNF Import and Export forms via the Control menu option Map Converter.

 Existing customised mapping files will be required to be updated where the intent is to use the new
AVEVA E3D 2.1 Structural Catalogue. Sample mapping files are provided with the installation.

The standard P-lines existing for profiles in the new AVEVA E3D 2.1 Structural Catalogue are sufficient to
use the SDNF interface. It should be noted that within the new catalogue ANGLE profiles have a new
orientation convention in line with other products in the market. This is managed by the orientation
mapping file.

In regards to the import process it should be noted that only GENSECs will be created at import due to
SCTN elements being no longer used by the AVEVA E3D 2.1 Structural application.

 Please refer to the AVEVA E3D 2.1 User Documentation for further information regarding the
administration and use of the AVEVA SDNF Interface in AVEVA E3D 2.1.

AVEVA Everything3D 2.1.0.1, Release No. 52435.


Supports: Creation of Branch Reinforcement Supports (Support Type BR).
This fix release incorporates Branch Reinforcement Supports into the new AVEVA E3D 2.1 Supports
application. The Branch Reinforcement creation workflow has been aligned with the Supports application
interface and element hierarchy.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 7 of 17


Product Release Letter

List of Fault Corrections


This release includes the following fault corrections:
Incident Defect Product /
Description
number number Module
Title: View limits button should be activated when a view is selected in canvas or
using the Explorer.
Symptoms: The View limits button only activated on making a view the Current
86790 185142 Draw
Element. In canvas selection did not cause the button to activate.
Previous/Known workaround: Utilise Current Element.
Solution: The current selection is now used to activate button and populate the form.

Title: Error on exporting Sheet with an incorrect dimension to DWG.


Symptoms: If a Sheet has at least one dimension with an invalid direction, e.g.
direction that is equal to direction of view, an error is presented “Severe serialization
87267 186131 Draw error occurred, operation aborted” on exporting to DWG.
Previous / Known workaround: Correction to dimension direction.
Solution: Fixed – LDIMs with incorrect direction are considered and handled in the
export.

Title: Label Grip invisible when leader line is set to off.


Symptoms: Grip becomes invisible where leader line is off (attribute Lleader eq false)
88357 190039 Draw on General and Symbolic labels.
Previous / Known workaround: None.
Solution: Fixed – grips are no longer invisible for identified scenario.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 8 of 17


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Enhancement - Customisation support for Revision Control Snapshot Capability.
Solution: The PmlRevisionControl object provides access to creating snapshots for
revisions and graphically displaying or comparing revisions. Like with the DRAW
Graphical User Interface, the snapshots are created and stored as an ARCHIV element
beneath the REVI.

Note that the PmlRevisionControl object only operates on the Sheet that is currently
active and displayed in the canvas.

import 'Aveva.Pdms.SDInteraction.UI'
using namespace 'Aveva.Pdms.SDInteraction.UI.Gui.RevisionControl'
!revisions = object PmlRevisionControl()
- 190229 Draw
Methods:
COMPAREREVISIONS(STRING, STRING)'
COMPAREREVISIONS(ANY, ANY)'
CREATESNAPSHOT(STRING)'
CREATESNAPSHOT(ANY)'
DISPLAYREVISION(STRING)'
DISPLAYREVISION(ANY)'
HASSNAPSHOT(STRING)'
HASSNAPSHOT(ANY)'

Please see the Draw Reference Manual for more information.

Title: Fatal Error opening sheet when 'units numeric dist' used.
Symptoms: Fatal Error opening sheet when 'units numeric dist' used.
88820 190466 Draw
Previous / Known workaround: None.
Solution: Fixed – error is no longer presented for given scenario.

Title: Changing Rotation angle to 90 degrees causes problems with limits volume box
& Section plane Grips.
Symptoms: The 3D View in Draw does not currently respect an applied View rotation
angle.
83826 178445 Draw
Previous / Known workaround: The Edit in 3D View button is disabled where a View
Rotation angle is not equal to zero.
Solution: Fixed – 3D View can now be used for Views where the View Rotation angle
is not equal to zero.

Title: Enhancement - PML access to element selection using the Draw browser.
Symptoms: It was not possible to use the Draw browser from PML to return a
selected element.
Solution: There is a new PML object PmlItemOpen which has several methods that
81449 179250 Draw can be used to show the Draw browser for different element types. The methods can
take an argument providing an initial location for the browser, such as a library. The
name of the selected element will be returned to the PML as a String.

Please see the Draw Reference Manual for more information.

Title: Equipment- Selecting view direction with PowerCompass exits primitive creation
command.
Symptoms: While creating the primitive, selecting a view direction using the
87269 186147 Everything3D
PowerCompass will exit the command.
Previous / Known workaround: Set view direction by alternative methods.
Solution: Fixed – PowerCompass may be used to set view direction.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 9 of 17


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Enhancement - Provide PML access to the entities selected in the 2D canvas
Symptoms: Currently there is no PML access to the 2D canvas selection as the existing
Selection object only operates on the 3D view.
Known workaround: Use of the ID syntax.
Solution: The new CanvasSelection object has been provided that is more generic
than the Selection object and allows the user to interact with the graphical selections
set for the current document in both 2D and 3D. For example it provides PML access
to the selection in both the 2D Draw canvas and the 3D canvas in Model and Draw.
Note that it only operates in graphical mode, not in TTY mode.

Unlike the Selection object, the CanvasSelection object allows PML access to the 2D
canvas. This does not replace the Selection object for 3D which continues to provide
more specialist and powerful access to the selection set in the 3D canvas.

70001 140179 Draw import 'aveva.interaction.generic'


using namespace 'Aveva.Interaction.Generic.Tools.Selection'
!canvas = object canvasselection()

Methods:
.canvasselection()
Creates an empty CanvasSelection object
.getselection()
Returns all the elements currently selected in the canvas as an ARRAY of DBREFs
.add(DBREF)
Selects the passed element if it corresponds to an entity
.remove(DBREF)
Deselects the passed element if it corresponds to an entity selected in the canvas
.clear()
Deselects all entities selected in the canvas

Title: Graphics Performance while manipulating Laser Data and creating Assemblies
with Laser Data in View.
Symptoms: Reduced graphical performance on manipulating laser data.
90314 193680 Everything3D
Previous / Known workaround: Remove laser data from 3D view.
Solution: Fixed - improved performance of graphical rendering with laser data in the
View.

Title: 3D view appears stretched across multiple monitors.


Symptoms: Distorted 3D view when stretched across multiple screens.
89529 191699 Everything3D Previous/Known workaround: None.
Solution: Fixed - Multiple monitors taken into account when setting maximum 3D
view size.

Title: Forms slower to show when laser data used.


Symptoms: Forms slower to show when laser data used.
90527 194068 Everything3D
Previous/Known workaround: Loading faster on second prompting of form.
Solution: Fixed – laser data no longer rendered for form ‘mini views’.

Title: GENPRI positions displayed in an incorrect location.


Symptoms: The position of imported Equipment (in AVEVA PDMS 12.1.4) is visually
92717 198673 Everything3D incorrect in position when viewed in AVEVA E3D2.1.
Previous / Known workaround: None.
Solution: Fixed – transformations are applied correctly.

Title: Enhancement - Unfill HVAC function.


Previous / Known workaround: Manual operation.
- 158241 HVAC
Solution: Provision of a new Unfill button within the HVAC user interface (and the
original Apply button has been renamed Fill).

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 10 of 17


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Stairs with Pitch Validation Value default - problem with configurations.
Symptoms: When a Stair Flight is modelled using a default where the pitch validation
value is used to calculate the optimum stair rather than the pitch angle, configurations
Stairs, Ladders
86848 185242 which meet the required default validation value are highlighted amber (with a
& Handrails
warning that they DO NOT meet the optimum pitch validation value).
Previous / Known workaround: None.
Solution: Fixed.

Title: Stairs using validation value show acceptable configurations as unavailable.


Stairs, Ladders Symptoms: Acceptable configurations shown as unavailable.
87606 186888
& Handrails Previous / Known workaround: None.
Solution: Fixed – all required configurations are now available.

Title: Walls & Floors - Setting elevation by selecting ref grid.


Symptoms: Clicking the elevation labels in Reference Grids does not set the elevation.
81154 172871 Structures
Previous / Known workaround: The user must click the grid plane lines of the grid.
Solution: Fixed – now able to select grid labels to set the elevation.

Title: Walls & Floors - Connections > Tidy > Joints form deletes JLDATUs
Symptoms: Connections > Tidy > Joints form deletes JLDATUs.
91773 197206 Structures
Previous / Known workaround: -
Solution: Fixed – tidy function applies to only Joint of Walls e.g. STWALL

Title: E3D Insight crashes/loops.


Symptoms: When trying to display a panel containing profiles with endcut type 104,
91093 195439
E3D Insight the system stops responding.
91095 195447
Previous/Known workaround: None.
Solution: Fixed.

Title: Piping component editor - Branch Name does not fit


Symptoms: Long branch names can overlap onto two lines if the name length is
around 30 characters but the overlap is overwritten by the spec gadget.
Previous/Known workaround: None.
90259 193493 Piping
Solution: The branch name field width has been increased to handle approximately 36
characters on a single line. It will accommodate the maximum of 50 characters on two
lines with no overlap. The spec name field width has been increased by a similar
amount.

Title: Piping - Presentation of the Surface Treatment Report


Symptoms: Currently the user has to manually drag each column to make the entries
87042 185650 Piping visible.
Previous / Known workaround: Manually drag each column to desired position.
Solution: Fixed – default width increased.

Title: Enhancement - Filter on the Field List


83450 178315 Reports Previous / Known workaround: None.
Solution: Now able to apply a filter on the Field List and Parameter.

Title: Define Route - Pick the entry and exit points.


Symptoms: When creating a cable and using the define route option, application
currently attempts to select the two closest cableways for entry and exit points. This
does not work as expected because this does not consider the interference class of
86057 183586 Cable
the cableways with respect to the cable.
Previous / Known workaround: -
Solution: Fixed – user is able to pick the entry and exit points to populate the cable
branch entry form

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 11 of 17


Product Release Letter
Consolidated from previous fix releases:

AVEVA Everything3D 2.1.0.2, Release No. 52472.


Incident Defect Product /
Description
number number Module
Title: Cannot enter AVEVA E3D 2.1.
Symptoms: Error presented on failure to find the product executables within the
C:\Program\ file path.
88503 189490 Everything3D
Previous / Known workaround: Install AVEVA E3D 2.1 to a location without a space in
the file path.
Solution: Fixed.

Title: Insufficient brackets for expressions.


Symptoms: The textural form of expressions containing a mix of /, * do not always
have sufficient brackets to maintain the meaning of the expression.
190964 Everything3D
Previous / Known workaround: It is only the textural output which is affected,
internally the expression will evaluate correctly.
Solution: Fixed.

Title: System & Session Data.


Symptoms: For a ‘general’ E3D user, the Databases in an MDB are re-ordered so that
RW Databases are placed first in the list of current Databases in the MDB.
88515 189666 Everything3D Previous / Known workaround: Manipulate the MDB order to suit the current user
session requirements.
Solution: Databases defined dynamically in a dbset will be in reference number order.
Databases in the MDB retain the order they were assigned in Admin.

Title: Migration - Text and Symbol mirror on applying a negative Scale.


Symptoms: When applying a -1 to the XSCALE, the Symbol and inclusive Text
elements mirrors.
190054 Draw
Previous / Known workaround: None for described workflow.
Solution: On applying a negative scale the symbol will mirror but the text will remain
correctly orientated.

Title: Vertex Editor – Database Element Name cannot be modified.


Symptoms: Changing the DDNM for a DPPT in the Vertices Editor is not saved.
190189 Draw
Previous / Known workaround: Use canvas selection workflow.
Solution: Fixed.

Title: New labels inherit LAYE justification and alignment overriding template.
Symptoms: When creating new labels from PML (or auto-tagging), the default tends
to be incorrectly JUST LEFT and ALIGN BBODY.
Previous / Known workaround: Manual modification.
189224 Draw
Solution: Default values for Alignment and Justification attributes on LAYE and SLAB
elements are set to ‘By Template’. Note: that when creating new LAYE elements from
the Autotagging form values are overwritten by the default file PDMSUI\dflts\dra-gen-
taglay. This file is customisable by the user.

Title: New pseudo attribute required to determine if a GENSEC is a tapered profile.


Symptoms: Missing attribute.
89705 192120 Catalogue
Previous / Known workaround: None.
Solution: LTAPER attribute added.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 12 of 17


Product Release Letter
Incident Defect Product /
Description
number number Module

Title: Length of GENSEC doesn't include the cut when a negative is inside.
Symptoms: The length of GENSEC doesn't include the cut when a negative is inside.
184280 Structures
Previous / Known workaround: None.
Solution: TCTL now accounts for negative primitives for straight GENSECS.

Title: Split command will not split GENSECs where not created in plane of member.
Symptoms: When attempting to split a GENSEC with another GENSEC when the
GENSECs have not been created in the plane in which they lay, the split does not
88572 189582 Structures work.
Previous / Known workaround: None.
Solution: Fixed.

Title: Error in Bracing Gap functionality.


Symptoms: When attempting to modify bracing gaps in the instance there are no gap
88361 189165 Structures reference elements an error is displayed.
Previous / Known workaround: None.
Solution: Fixed.

Title: Require current radius to be displayed when changing a curved GENSEC radius.
Symptoms: Current radius feedback is not shown.
86764 185072 Structures
Previous / Known workaround: Reference to Properties Grid.
Solution: Fixed – feedback provided.

Title: Curved GENSECS – no feedback when inputting an invalid radius


Symptoms: When using the grips to enter a radius for a curved GENSEC, if an
excessive radius to fit the GENSEC is entered, no warning is presented to the user
86765 185073 Structures
informing the user the entered value is invalid.
Previous / Known workaround: -
Solution: Fixed – invalid values can no longer be input.

Title: Require a Repeat option for the Mitre command.


Symptoms: Enhancement request.
162030 Structures Previous / Known workaround: -
Solution: Repeat mode now available via the Context Editor menu for the Mitre
command.

Title: Mitre operation - option to connect mitred ends.


Symptoms: Enhancement request.
174697 Structures Previous / Known workaround: -
Solution: Connection option added to Mitre command and may be selected by the
user (not default mode).

Title: Detail mode initial rise stairs have incorrect length extension / landing panels.
Symptoms: When an initial rise configuration stair flight is created which has an
Stairs, Ladders extension and/or a landing, the panels on the extension and landing are not allowing
87415 186456
& Handrails for a tread overlap.
Previous / Known workaround: -
Solution: Fixed.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 13 of 17


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Stair Flight - Rise position altered while modifying Detail Mode Stair flight with
Initial Rise configuration.
Stairs, Ladders Symptoms: It has been observed that Rise Above\Below tread alters while modifying
186751
& Handrails Stair flight.
Previous / Known workaround: None.
Solution: Fixed – check has been added.

Title: Stair Flight using default with pitch validation presents warning.
Symptoms: When modelling a stair flight which is using a Default where the pitch
validation rather than angle is used to calculate the stair, a warning message is
Stairs, Ladders
87605 186886 displayed when picking the required configurations.
& Handrails
Previous / Known workaround: Issue reproducible for the pitch Validation Value in
the range of 600 to 660.
Solution: Fixed.

Title: Initial Rise Stair Flights - pitch value incorrectly rounded


Stairs, Ladders Symptoms: None.
81224 173027
& Handrails Previous / Known workaround: None.
Solution: Fixed.

AVEVA Everything3D 2.1.0.1, Release No. 52435.


Incident Defect Product /
Description
number number Module
Title: Search Performance when applying a PML expression.
Symptoms: A search under the World element with element Type set to [ALL] and the
free filter expression set to not(unset(description) has a negative performance impact.
- 176965 Everything3D
Previous / Known workaround: Recommended that such searches are avoided.
Solution: Fixed - improved performance of message window when receiving errors
from search.

Title: Open item browser dialog is slow to appear with large projects.
Symptoms: Open item browser dialog is slow to appear.
Previous / Known workaround: None.
Solution: The open and admin hierarchy browse dialogs, as well as all 'create element'
dialogs, now start up faster as the database is read as and when the hierarchy is
- 178093 Draw expanded. To support this development element name searches in the browser are
based upon a database name search. Note that the search finds any elements of the
appropriate type with a name containing the search fragment anywhere in the name,
as before. However, searching for elements with a name beginning with a search
fragment is faster and can be performed by prefixing the search text with a forward
slash '/' to indicate this is the start of the name.

Title: Element Selection browser dialogs should hide empty libraries.


Symptoms: Certain browser dialogs targeted at element selection display empty
directories and allow element creation which is inappropriate to the workflow.
Previous / Known workaround: None.
- 185795 Draw Solution: Browser dialogs targeted at element selection (as opposed to 'create' or
'picture file open'), now disallow the 'New' option either via the top left hand button
or via right click. In addition, these dialogs will only show hierarchy containing existing
elements of the required search types (this improves performance and allows
elements to be found more easily).

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 14 of 17


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Error presented when using check support in Clasher where the Supports
application is not loaded
- 185520 Supports Symptoms: Error: Aborted !!findSupports.addPickedElement(!this.re turn[1], FALSE)
Previous / Known workaround: Open Support application prior to clashing.
Solution: Fixed.

Title: Exception when setting an ENDATU POSL attribute using the Properties Grid.
Symptoms: Exception experienced on the system attempting to find the plines for the
187619 Everything3D ENDATU.
Previous / Known workaround: Set attribute via the command window.
Solution: Fixed – system checks ENDATU owner for a list of allowed Plines.

Title: Incorrect Isometric for a Pipe containing a PIPCA connection at a TEE where
Hyper Plant is on and weld numbers from Database.
- 186032 IsoDraft Symptoms: Incorrect Isometric for described scenario.
Known workaround: None.
Solution: Fixed.
Title: The default bend selection form does not reload available bending machines.
Symptoms: Available bending machines are not reloaded on opening the default bend
radius form and an error occurs when a wall thickness cannot be obtained.
Previous / Known workaround: Restart E3D to reload the bending machines but no
- 187009 Piping workaround for described wall thickness error.
Solution: Fixed - the form now reloads the available bending machines each time the
form is opened. The form also handles the case where a wall thickness cannot be
obtained.

Title: Updated Samples.zip omitted from E3D 2.1 install.


Symptoms: As described.
- 187013 Everything3D
Previous / Known workaround: None.
Solution: Fixed – updated Sample.zip delivered with fix release.
Title: Creating a SYTM under a VSI Template causes an Error Message.
Symptoms: The error only occurs if the VSI Library is created using the right-click
83881 178524 Draw menu option rather than clicking the 'create' button.
Previous / Known workaround: Utilise the ‘create’ button to create the VSI Library.
Solution: Fixed – no error received.

Title: Intelligent Text - unable to open a bracket directly after a closing bracket.
Symptoms: Unable to open a bracket directly after a closing bracket
61674 112168 Draw Previous / Known workaround: Insert and then remove a <space> between bracket
characters.
Solution: Fixed.

Title: Compound joints (SCTN > SNOD > SCOJ > SUBJ) are omitted during SCTN to
GENSEC conversion
- 181832 Structures Symptoms: As described above.
Previous / Known workaround: -
Solution: Fixed.

Title: Location of a View on a RSO cannot be changed.


Symptoms: After creating a view in an RSO plane, if the view is copied, the location in
86862 185278 Draw the Properties Grid cannot be changed to another RSO location.
Previous / Known workaround: None.
Solution: Fixed - it is now possible to change Location definition.

Title: Revision Form - unable to expand Text Column.


Symptoms: Unable to expand the Rev By Text field.
- 190049 Draw
Previous / Known workaround: None.
Solution: Fixed - all columns can now be resized as required.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 15 of 17


Product Release Letter
PRODUCT QUALITY STATEMENT
The development, maintenance and testing of AVEVA Solutions’ software products is carried out in
accordance with the AVEVA Quality Management System lifecycle processes and this document includes a
summary of the testing carried out on this release and a list of significant defects known to exist at the
time of release.

Development Testing
Developers have carried out unit testing of each enhancement and/or fix in the development environment
to verify that any new functionalities have been correctly implemented and identified defects have been
corrected.
Regression tests have been run in the development environment to verify that enhancements and/or fixes
have not adversely affected the integrity of the product.

System Testing
Independent system testing has been carried out on this product, as released, to verify that it installs
correctly in all supported configurations that any new functionalities have been correctly implemented
and identified defects have been corrected.

Acceptance Testing
AVEVA’s Training and Product Support group is satisfied that the System Testing for this release is
sufficient to assure product quality.
Any exceptions found during Acceptance Testing or after release will be reported in the Product Release
Latest Update Note on AVEVA's support web site http://downloads.aveva.com/52486/w52486.pdf.

Exceptions – Significant Defects and Recommended Workarounds


AVEVA intends to fix the defects listed below in a fix release or service pack as soon as reasonably possible.

 AVEVA Bocad Steel Interface (TFS-196401). Substitute symbols (question mark) are visible in AVEVA
Bocad where Unicode characters are used in the project header or user data. In order to exchange
Unicode characters in AVEVA Bocad Steel files, a user may edit the BocadUni.map file to replace
ENCODING:ASCII to ENCODING:UTF8BOM.

 AVEVA Bocad Steel Interface (TFS-196700). GENSECs with a Spec Ref including special UTF8 Characters
are not mapped (import or export). The issue principally concerns the provided Russian Standard where
the mapping file requires further amendment.

 AVEVA Bocad Steel Interface (TFS-196909). The Chinese mapping file requires further amendment to
correct profiles with CatRef CH_WT_S3_WG and to address the incorrectly mapped diameter for Bocad
profiles in the following series: CH_ST_S1_WG, CH_ST_S2_WG, CH_ST_S3_WG, CH_WT_S1_WG and
CH_WT_S3_WG.

 Pipe Fabrication utilities are not included in the first release of AVEVA E3D 2.1.0. Functions linked to
Pipe Fabrication are displayed in the user interface but are greyed out.

 Laser. The Box and Cylinder primitives (only) are fully compatible with the Highlight and Mask laser data
features. The Box primitive (only) is fully compatible with the forming of a Demolition package volume.

 Supports (TFS-183921). It is not currently possible to set the Support joint justification to a Pline of the
Column.

 3D View Selection (TFS-174778). Pipes with no component cannot be selected via a window selection in
the 3D View.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 16 of 17


Product Release Letter
 Install (TFS-186636). AVEVA E3D 2.1 currently does not support a Project installed on a Windows 8.1 D:\
partition where the file path contains spaces. The issue is linked to the install of AVEVA E3D 2.1 to a
volume with 8dot3naming disabled referencing projects installed to a volume with 8dot3naming
enabled. An installation error is presented on first running AVEVA E3D 2.1 and on subsequent occasions
the login form is presented but without Project tiles for selection.

Interoperability with AVEVA PDMS / Hull & Outfitting 12.1.SP4.


 Hull Projects. Spaces in Project pathnames should be avoided for AVEVA Marine (Hull) 12.1.SP4 data
being used within AVEVA E3D 2.1.

 AVEVA Global. All extract database FLUSH and ISSUE commands must be undertaken from within
AVEVA E3D 2.1 when accessing a globalised project with both AVEVA PDMS / Hull & Outfitting 12.1.SP4
and AVEVA E3D 2.1.

For the latest list of exceptions and other updates, please see the Product Release Latest Update Note on
AVEVA's support web site http://downloads.aveva.com/52486/w52486.pdf.

Please refer also to the Product Release Latest Update Note for the original full release,
http://downloads.aveva.com/52421/w52421.pdf.

d52486 4-May-16  Copyright 2016 AVEVA Solutions Limited Page 17 of 17