Displacement Assembly
Displacement 2
Assembly
$3&$35XQLWVDUHPRXQWHGRQDZDOO7KHXQLWLV¿WWHGWRWKH
wall by screwing through the back plate after having removed
the front panel and air distribution plate.
APO units are mounted in the same way to a wall with a
recessed plenum.
Assembly
ATC/ATR units are wall-mounted using mounting brackets only,
or in combination with a base. If ceiling-mounted, drop rods
or perforated bands should be used to attach the unit to the
ceiling.
$72XQLWVDUH¿[HGWRDSOHQXPZLWKVFUHZVWKURXJKWKHIUDPH
Assembly
The AWB terminal is wall mounted by removing the front plate
and screwing the back plate in place. If a base is used, it is to
EH¿WWHG¿UVWWRWKHERWWRPRIWKHWHUPLQDO
7KHGXFWFRYHULVPRXQWHGWRWKHZDOOXVLQJFRUQHUSUR¿OHV7KH
OHQJWKRIWKHGXFWFRYHULVPDGHWRWKHFXVWRPHU¶VVSHFL¿FDWLRQ
(maximum section length 1960mm). For longer ducts, several
sections can be selected, taking care to overlap them on the
join.
Assembly
The ARC terminal is installed by removing the front plate and
screwing the back plate onto the wall.
L Max
,IDEDVHLVXVHGLWQHHGVWREH¿WWHGWRWKHERWWRPRIWKH
WHUPLQDO¿UVW
7KHGXFWFRYHULVPRXQWHGWRWKHZDOOXVLQJFRUQHUSUR¿OHV7KH
OHQJWKRIWKHGXFWFRYHULVPDGHWRWKHFXVWRPHU¶VVSHFL¿FDWLRQ
See Dimensions (Page 20 in the Displacemen-catalogue) for
2m
maximum section length. For longer ducts, several sections can
be selected, taking care to overlap them on the join.
Assembly
The AVC terminal is installed by removing the front plate and
screwing the back plate onto the wall.
,IDEDVHLVXVHGLWQHHGVWREH¿WWHGWRWKHERWWRPRIWKH
WHUPLQDO¿UVW
L Max
7KHGXFWFRYHULVPRXQWHGWRWKHZDOOXVLQJFRUQHUSUR¿OHV7KH
2m
OHQJWKRIWKHGXFWFRYHULVPDGHWRWKHFXVWRPHU¶VVSHFL¿FDWLRQ
See Dimensions (Page 23 in the Displacemen-catalogue) for
maximum section length. For longer ducts, several sections can
be selected, taking care to overlap them on the join.
Assembly
Wall-mounting onto plenum
7KH(:2LV¿WWHGRQWRDSOHQXPUHFHVVHGLQDZDOOWKHIUDPH
of EWO is screwed onto the plenum box.
Ceiling Duct
7KH(:2LV¿WWHGRQWRDGXFW¿[LQJLVGRQHE\GULOOLQJVFUHZ
KROHVLQWKHPPIURQWÀDQJH
Circular Terminals
ABC
Assembly
$%&ZLWKEDVH7KHEDVHLV¿UVW¿[HGWRWKHÀRRUXVLQJVFUHZV
The terminal is secured to the base via pop-rivets. 2
$%&ZDOODVVHPEO\7KHXQLWVDUHPRXQWHGWRWKHZDOOXVLQJ
EUDFNHWVZKLFKDUHGHOLYHUHGSUH¿WWHGWRWKHWHUPLQDO7KH
ZDOOEUDFNHWVDUH¿UVWVFUHZHGLQWRWKHZDOOFRUQHUDOORZLQJ
the terminal to be bolted onto the brackets.
1
3
100-200
Auditorium Terminals
GWR
Assembly
GWR
GWR/O
Hygiene Terminals
HMO / HMC / HMR
Assembly
7KH+02LVGHVLJQHGWREHPRXQWHGÀXVKWRDZDOO7KH
plenum box (supplied by others) is recessed into the wall
and screwed to wooden battens or similar. The HMO unit is
screwed to the plenum box. Depending on application, the
plenum box can be made of stainless steel or galvanised
sheet steel.
The HMC / HMR terminals are designed to be wall-mounted.
Unless support legs are used, we recommend that the unit
EH¿[HGDSSUR[PPDERYHÀRRUOHYHO7KHEDFNSODWH
LVWREH¿[HGWRWKHZDOODQGWKHWHUPLQDODVVHPEO\WKHQ
¿WWHGRQWRWKHFDVHZRUN
Adjustment
$GMXVWPHQWWRWKHDLUÀRZLVFDUULHGRXWYLDDQH[WHUQDO
adjusting damper.
Maintenance
There are no parts in the unit that have to be replaced. 200
7RFOHDQWKH+02XQLWLW¿UVWQHHGVWREHUHPRYHGIURP
WKHSOHQXPER[8VHPLOGGHWHUJHQWVROXWLRQDQGÀXVKWKH
HMO with water.
HMC / HMR can be opened using the toggle latches.
Plenum box, front and air distribution plate can be cleaned
ZLWKDPLOGGHWHUJHQWVROXWLRQDQGÀXVKHGWKURXJKZLWK
water.