AIM:
OBJECTIVE:
To calculate overall heat transfer coefficient, logarithmic mean temperature difference
and effectiveness of finned tube heat exchanger.
APPARATUS REQUIRED:
1.Circulating pump
2.Rotameter
3.Electrical Heater
4.Thermocouple
PROCEDURE:
a) Clean the apparatus and make water bath free from dust.
b) Close all the drain valves provided.
c) Fill water bath ¾ with clean water and ensure that no foreign particles are there.
d) Ensure that all ON/OFF switches given on the panel a read OFF position.
e) Now switch on the main power supply(220 V AC, 50 Hz).
f) Switch on heater by operating switch given on the panel.
g) Set temperature of the water bath with the help of digital temperature
controller.
h) Open flow control valve for hot water supply.
i) Switch on magnetic pump for hot water supply.
j) Adjust hot water flow rate with the help of flow control valve provided
before rotameter.
k) Record the hot water flow rate with the help of rotameter
l) Recordthetemperaturesofhotandcoldfluidinlet&outletwhensteadystateis
achieved.
m) Take readings at different flow rates of hot water and cold air.
OBSERVATIONS:
Data:
SS tube outside dia , do = mm
SS tube inner dia, di = mm
Tube length ,L = mm
Fin height, Y = mm
Fin thickness, X = mm
No. of fins, Nf =
ID of outer shell, Ds = mm
OBSERVATIONS TABLE:
S.no T1(hi) T2(ho) T3(ci) T4(co)
MODEL CALCULATIONS:
Af = 2L(do+2NfY)
= m²
* The heat transfer rate
Qavg = Qh + Qc /2
LMTD = ∆T2-∆T1/ln(T2/T1)
Q= U /A*LMTD
Cs = Wc * Cpc
CT= Wh * Cph
CR = Cmin /Cmax
By NTU method
NTU = UA /C min
RESULT: