1. INTRODUCTION
This ESYD Guidance presents the main points of the Directive 95/16/EC, with an emphasis
on the obligations of the manufacturer and the notified body, in order to identify the critical
points in the conformity assessment procedure and to facilitate the accreditation procedure
of bodies to be notified.
In any case, the involved parties shall be informed fully with the provisions of this Directive,
the applicable standards, as well as with the relevant Guidelines issued by the European
Commission and being available on the web page www.newapproach.org.
This Guidance supplements Guidance Document EA-2/17, regarding the requirements for
the assessment of organizations with the purpose of notification.
In addition, this ESYD Guidance is applicable to periodic inspections of lifts, contains both
application guidelines for certification and inspection bodies in the process of being
accredited or having been accredited by ESYD, but also for ESYD assessors and refers inter
alia to:
2. DEFINITIONS
Lift inspection means the process of carrying out standard inspections and tests on the
lift, intended to verify its conformity with safety specifications (regulations and standards).
Existing lift is characterized each lift that has been in operation and is in use, regardless of
the year of installation.
Initial inspection of lift means the inspection of a new lift by an accredited/notified body,
before it is placed on the market and is put into use.
Scope
For the purposes of this Guidance, ‘lift’ shall mean a lifting appliance serving specific levels,
having a carrier moving along guides which are rigid and inclined at an angle of more than
15 degrees to the horizontal, intended for the transport of:
— persons,
— persons and goods,
— goods alone if the carrier is accessible, that is to say a person may enter it without
difficulty, and fitted with controls situated inside the carrier or within reach of a person
inside the carrier.
(PD 57 GG 97/2010 “Adaptation of Greek legislation to the Directive 2006/42/EC of the
European Parliament and of the Council on machinery, and amending Directive 95/16/EC”)
Lifting appliances moving along a fixed course even where they do not move along guides
which are rigid shall be considered as lifts falling within the scope of the Lifts Directive (e.g.
the lifts with ribbed guides).
ANNEX V
EC type-examination (module B)
a. EC type-examination of safety components
b. EC type-examination of lifts
ANNEX VI
Final inspection
ANNEX VIII
Product quality assurance (module E) of safety components
ANNEX IX
Full quality assurance (module H) of safety components
ANNEX XI
Conformity to type with random checking (module C) of safety components
ANNEX X
Unit verification (module G) of lifts
ANNEX XII
Product quality assurance for lifts (module E)
ANNEX XIII
Full quality assurance for lifts (module H)
ANNEX XIV
Production quality assurance for lifts (module D)
A. the manufacturer selects the module/annex to be applied for the conformity assessment
of safety components as shown below:
B. The installer selects the module/annex to be applied for the conformity assessment
relating to lifts as shown below:
C. Since the full quality assurance procedure as set out in annex XIII can be applied both in
the design and installation phase and only in the design phase, it is possible for the person
who performs only the design and construction and not the installation to have the full
quality assurance system approval.
Therefore the installer selects the module/annex (production phase) to be applied for the
conformity assessment relating to lifts as shown below:
Full quality assurance * Product quality assurance XIII (module H) & XII (module E)
Full quality assurance * Production quality assurance XIII (module H) & XIV (module
D)
In this case, the designer of the lift (design phase) shall provide all documentation to the
installer to ensure the correctness and completeness of the final inspection of the
installation, including the documentation of design inspection, in accordance with paragraph
3.3 of annex XIII.
The manufacturer or the person responsible for installation, respectively, in each case draws
up the declaration of conformity.
* supplemented by an examination of the design, if the latter is not wholly in accordance with the
harmonized standards.
In annex 1 of this Guidance, the main points of essential safety requirements are set out.
The preparation of the technical dossier for a lift and its safety components is one of the
most critical points in the conformity assessment procedure by a third party and applies to
annexes V (module B), X (module G), and practically in XIII (module H), in the sense that
the quality management system of the manufacturer must include the information
contained in the technical dossier.
The technical dossier should include the following:
- A general description of the representative model of the lift (all possible extensions should
be clearly indicated) / of the safety components (including the area of use and conditions)
- Essential requirement(s) taken into consideration and the means adopted to satisfy it
(them) (e.g. a harmonized standard)
- A copy of the lift instruction manual / a copy of the assembly instructions for the safety
components
- Steps taken at the installation stage to ensure that the series-produced lift conforms to
the provisions of the Directive / at the manufacturing stage to ensure that series-produced
safety components conform to the safety component examined.
4.2.1. Lodges an application for assessment of his quality assurance system with a
notified body. The application must include:
a. all relevant information on the lifts, in particular information which makes for an
understanding of the relationship between the design and operation of the lift and
enables conformity with the requirements of the Directive to be assessed,
b. the documentation on the quality assurance system.
4.2.2. Maintains a quality assurance system that ensures conformity of the lifts with the
requirements of the Directive that apply to them.
4.2.3. Documents all the elements, requirements and provisions adopted, in a systematic
and orderly manner in the form of written measures, procedures and instructions.
not be applied in full, the means that will be used to ensure that the
requirements of the Directive that apply to the lifts will be met.
Note 3: the requirement for the competence to design a lift does not preclude the
possibility of supply of components.
Note 5: choosing the right type of machinery requires both knowledge of its
application as well as knowledge related to friction, way of connection of
ropes, etc.
d. The examinations and tests that will be carried out on acceptance of the
supplies of materials, components and sub-assemblies.
f. The examinations and tests that will be carried out before (inspection of
installation conditions: shaft, housing of machinery, etc.), during and after
installation (including at the very least the tests laid down in Annex VI,
Section 4 (b)).
g. The quality records, such as inspection reports and test data (including
internal audit reports, covering all activities of the Quality Management
System), calibration data, reports on the qualifications of the personnel
concerned, etc.
4.2.4. Undertakes to discharge the obligations arising from the quality assurance
system as approved and to ensure that it is maintained in an appropriate and
efficient manner.
4.2.5. Keeps the notified body that has approved the quality assurance system
informed of any intended updating of the quality assurance system.
4.2.6. Allows the notified body access for inspection purposes to the design,
manufacture, assembly, installation, inspection and testing and storage
locations, and must provide it with all necessary information, in particular:
b. The quality records provided for in the design part of the quality assurance
system, such as results of analyses, calculations, tests, etc.
c. The quality records provided for in the part of the quality assurance system
concerning acceptance of supplies and installation, such as inspection reports
and test data, calibration data, reports on the qualifications of the personnel
concerned, etc.
4.2.7. Retains for a period of 10 years after the lift has been placed on the market,
keeping at the disposal of the national authorities
b. The updating referred to in the second paragraph of Section 3.5 (Annex XIII).
c. The decisions and reports from the notified body which are referred to in the
final paragraph of Section 3.5 and in Sections 4.3 and 4.4 (Annex XIII).
d. Where the installer is not established in the Community, this obligation falls
to the notified body.
4.3 Full quality assurance (module H) Annex IX for the safety components
4.3.2. Lodges an application for assessment of his quality assurance system with a
notified body. The application must include:
4.3.3. Maintains a quality assurance system that ensures compliance of the safety
components with the requirements of the Directive that apply to them and
enables lifts to which they have been correctly fitted to satisfy those
requirements.
o the examinations and tests that will be carried out before, during and after
manufacture, and the frequency with which they will be carried out,
o the quality records, such as inspection reports and test data, calibration
data, reports on the qualifications of the personnel concerned, etc.,
o the means of monitoring the achievement of the required design and product
quality and the effective operation of the quality assurance system.
4.3.6. Undertakes to discharge the obligations arising from the quality assurance
system as approved and to ensure that it is maintained in an
appropriate and efficient manner.
4.3.7. Informs the notified body which has approved the quality assurance system of
any intended updating of the quality assurance system.
4.3.8. Allows the notified body access for inspection purposes to the design,
manufacture, inspection and testing, and storage locations, and shall provide it
with all necessary information, in particular:
— The quality records provided for in the design part of the quality system, such
as results of analyses, calculations, tests, etc.
— The quality records provided for in the manufacturing part of the quality
assurance system, such as inspection reports and test data, calibration data,
reports on the qualifications of the personnel concerned, etc.
4.3.9. Retains for a period of 10 years after the last safety component has been
manufactured, keeping at the disposal of the national authorities:
— The decisions and reports from the notified body which are referred to in
the final paragraph of Section 3.4 and in Sections 4.3 and 4.4 (Annex IX).
Where neither the manufacturer of the safety components nor his authorized representative
is established in the Community, the obligation to keep the technical documentation
available falls to the person who places the safety component on the Community market.
The person that performs the lift manufacture, assembly, installation and final inspection
shall have authorization of electrician installer, Specialty D.
The engineers referred to in article 1 of L. 6422/1934 have the right to carry out the design
of the lift.
For the conduct of the final inspection of the lift, the installer shall have at his disposal the
equipment referred to in paragraph 7 of the present Guidance.
The notified body must have specific control procedures for each Module it has activities.
5.1.1.1 examine the technical dossier to assess how far it can meet the desired
aims,
5.1.1.2 examine the representative model of the lift / safety component to check
that it has been manufactured in accordance with the technical dossier,
5.1.1.3 perform or have performed the appropriate checks and tests necessary to
verify whether the solutions adopted by the installer of the lift/the
manufacturer of the safety component meet the requirements of the
Directive.
The audit team shall examine the completeness of the technical dossier, the content of
which is presented in paragraph 4.1 of the present Guidance (see also Annexes 7 and 8).
DESIGN INSPECTION
When the design is not entirely in accordance with harmonized standards, the notified
body must ascertain:
5.1.2.1 Whether the design conforms to the provisions of the Directive and, if it does,
issue an ‘EC design examination certificate’ to the installer, stating the limits of
the certificate's validity and giving the details required for identification of the
approved design.
5.1.2.2 Assess the quality assurance system to determine whether it satisfies the
requirements of Section 3.2 of Annex XIII of the Directive. It must presume
compliance with these requirements in respect of quality assurance
systems that implement the relevant harmonized standard (1).
The auditing team must have at least one member with experience of
assessment in the lift technology concerned.
The assessment procedure must include at least a visit to the lift installer's
premises and a visit to the installation site.
Specifically, the assessment conducted by the certification body must include
audit of the manufacturer, who applies an approved quality assurance system for
the design, manufacture, final inspection of the lift and testing.
The assessment procedure must also include a visit to the manufacturer's
premises (on-site).
(1) This harmonized standard will be EN 29001, supplemented where necessary to take
account of the specific features of the lifts.
5.1.2.3 Notify its decision to the lift installer. The notification must contain the conclusions
of the examination and the reasoned assessment decision.
5.1.2.4 Assess the modifications proposed and decide whether the modified quality
assurance system will still satisfy the requirements referred to in Section 3.2 of
Annex XIII of the Directive or whether a reassessment is required.
5.1.2.5 Must periodically carry out audits to make sure that the manufacturer of a lift
maintains and applies the quality assurance system and must provide the
manufacturer of a lift with an audit report.
In the policy and procedures of the notified body, the criteria according to which
the minimum audit frequency is defined must be determined.
5.1.2.6 May pay unexpected visits to the premises of a lift installer or to the
assembly site of a lift. At the time of such visits, the notified body may carry out
tests or have them carried out in order to check the proper functioning of the
quality assurance system where necessary. It must provide the lift installer with a
visit report and, if a test has been carried out, with a test report.
The installer shall notify the list of installed lifts of his clients to the notified body.
5.1.2.7 Must forward to the other notified bodies the relevant information concerning the
quality assurance systems issued and withdrawn.
Notify its decision to the manufacturer of the safety components. The notification
must contain the conclusions of the examination and the reasoned assessment
decision.
Assess the modifications proposed and decide whether the modified quality assurance
system will still satisfy the requirements referred to in Section 3.2 of Annex IX of the
Directive or whether a reassessment is required.
Notify its decision to the manufacturer. The notification must contain the conclusions
of the examination and the reasoned assessment decision.
Must periodically carry out audits to make sure that the manufacturer of
the safety components maintains and applies the quality assurance
system and must provide an audit report to the manufacturer of the
safety components.
Must forward to the other notified bodies the relevant information concerning the
quality assurance system approvals issued and withdrawn.
The notified body shall carry out checks and tests that shall cover in particular:
a) Examination of the documentation to check that the lift conforms to the representative
model of the lift approved in accordance with Annex V part B of the Directive.
b) — operation of the lift both empty and at maximum load to ensure correct installation
and operation of the safety devices (end stops, locking devices, etc.),
— operation of the lift at both maximum load and empty to ensure the correct
functioning of the safety devices in the event of loss of power,
— static test with a load equal to 1,25 times the nominal load.
The final inspection must be carried out by a person not involved in the design,
manufacture, assembly and installation.
The notified body must define the qualifications of the personnel involved in the conformity
assessment procedures. This personnel must satisfy the corresponding requirements that
are reported in Annex II of the present Guidance.
The persons carrying out lift installation inspections are divided in four categories:
• Trainee inspector
• Inspector
• Auditor
• Lead Auditor
Trainee inspectors and inspectors must be Dipl. Mechanical Engineers, Electrical Engineers,
Mechanical-Electrical Engineers, Naval-Mechanical Engineers and Naval Engineers or
Engineers with equivalent specialty, University graduates, who are members of the
Technical Chamber of Greece (T.E.E.) and holders of the respective professional license, as
well as Technologist Engineers with corresponding specialties, graduates of Technological
Institutions, provided that they are registered in the Ministry of Development registers.
Everyone who has activities in foreign countries must have the corresponding
equivalent license, as required by local Legislation.
Note: In cases of Engineers with other specialties, having post-graduate degree in mechanical
engineering or in similar sector and documented experience of more than 10 years in the technical field
of lifts, compatibility is proven with the requirements of the present Guidance. These trainee inspectors
and inspectors have the possibility to develop under the same conditions as all other trainee inspectors
and inspectors.
In order to become an inspector (provided that the aforementioned qualifications exist), one
must have attended a training seminar, relative to lift inspections, of a minimum duration of
80 hours.
Moreover, he must have participated in at least 60 50 inspections, 40 20 of which must
have been carried out in hydraulic lifts and 20 30 in electrical lifts. 50% of these inspections
must be initial inspections, in each type of lift (hydraulic, electrical).
Auditors and lead auditors must be Dipl. Mechanical Engineers, Electrical Engineers,
Mechanical-Electrical Engineers, Naval-Mechanical Engineers and Naval Engineers or
Engineers with equivalent specialty, University graduates, who are members of the
Technical Chamber of Greece (T.E.E.) and holders of the respective professional license, as
well as Technologist Engineers with corresponding specialties, graduates of Technological
Institutions, provided that they are registered in the Ministry of Development registers.
Everyone who has activities in foreign countries must have the corresponding
equivalent license, as required by local Legislation.
Note: In cases of Engineers with other specialties, having post-graduate degree in mechanical
engineering or in similar sector and documented experience of more than 10 years in the technical field
of lifts, compatibility is proven with the requirements of the present Guidance.
In order to become an auditor (provided that the aforementioned qualifications exist), one
must have attended a training seminar, relative to lift inspections, of a minimum duration of
80 hours. In addition, he must have attended a training seminar of a minimum duration of
50 hours, relative to technical dossier examination procedures, according to the current
national and European regulations.
Moreover, he must have participated in at least 120 100 inspections, 80 40 of which must
have been carried out in hydraulic lifts and 40 60 in electrical lifts. 50% of these inspections
must be initial inspections, in each type of lift (hydraulic, electrical). He must also have
participated in the examination of 40 20 lift technical dossiers, as a trainee auditor.
In order for the auditor to be upgraded to lead auditor, additionally to the aforementioned in
paragraph 5.4.4, he must have carried out at least 120 100 inspections, 80 40 of which
must have been carried out in hydraulic lifts and 40 60 in electrical lifts. 50% of these
inspections must be initial inspections, in each type of lift (hydraulic, electrical). He must
also have conducted 60 40 lift technical dossiers examinations.
Inspectors have the right to carry out on-site lift inspections (initial and periodic).
Auditors have the right to carry out on-site lift inspections and lift technical dossiers
examinations.
Lead auditors, in addition to the aforementioned, can participate as experts in special cases
of inspections, appeal and accident examinations, according to the current legislation.
Furthermore, the notified body must provide training to the aforementioned personnel,
which must comprise:
6.1 During the inspection of lifts and depending on the type of the installation and the year
at which the lifts’ legalization document was issued, inspection certificate, operation license
or registration certificate/decision or preliminary installation approval or building permit
upon which the installation was made – Article 10 “periodic Inspections & tests” and article
15 “Transitional Provisions” of Common Ministerial Decision No Φ9.2/28425 (Government
Gazette issue 2604B/2008), there might be required:
6.2 Inspection Checklists, including the minimum requirements they must cover, are
listed here below:
6.3 Furthermore an exemplar of the list of requirements for the content of the technical
dossiers is provided for:
6.4 For the documentation of the inspections that have been conducted, photographic
evidence is required. Specifically the following should be photographed as a minimum:
The presence of the inspector shall be recorded in one of the previously mentioned items
with his consent.
Taking into consideration annex D of the standards ELOT EN 81.1:1999 & ELOT EN
81.2:1999 “Examinations and tests before putting into service” concerning the minimum
measurements and verifications that need to be conducted during the onsite inspection to
the lift installation:
*INDICATIVE
MEASURAND Measurement Unit MEASUREMENT
INSTRUMENT
Dimensional Measurements
Length Meter (m) Tape measure
Thickness Millimeter (mm) Caliper
Speed Measurements
Speed Meters / second (m/sec) tachometer
Electrical Measurements
Electrical Current Ampere (A) Am meter
Electrical Voltage Volt (V) Volt meter
Electrical Resistance Ohm (Ω) Ohm meter
Insulation Resistance Mega - Ohm (MΩ) Insulation Tester
Illuminance Lux Lux meter
* The measuring instruments listed above are the minimum required. Alternatively, other
instruments and/or measurement methods can be used for the above measurands, provided
that they are documented.
8.1 The maximum number per day (on an 8 hour basis) of initial lift inspections that are
conducted by a qualified person should not exceed two (2), while it can be combined with
one (1) periodic inspection at the most.
8.2 The maximum number per day (on an 8 hour basis) of periodic lift inspections
conducted by a qualified person should not exceed four (4).
8.3 When a qualified person conducting lift inspections has to conduct one (1) initial
inspection per day (on an 8 hour basis), he can not conduct more than two (2) periodic
inspections on the same day, and vice versa.
8.4 On a weekly basis, a qualified person conducting lift inspections can perform lift
inspections for six (6) days (on an 8 hour basis) at the most, thus the total number of
initial & periodic lift inspections is adjusted according to the here above articles 5.7.1, 5.7.2
and 5.7.3.
According to the applicable national and European legislation, the context of the
declarations of conformity and certificates that the certification and/or inspection bodies
issue or review must include at least the elements described in the exemplars of annex II of
the Ministerial Decision No Φ9.2/28425 (Government Gazette issue 2604B/2008).
9.1 EC Declaration of conformity for installed electrical or hydraulic lift (according to
Annex II of the European Directive 95/16/EC as it was adopted by National
Legislation with the Common Ministerial Decision oik.32803/1308/97 (Government
Gazette issue 815B/1997))—(Annex 9)
9.2 Certificate of conformity – Inspection Certificate “Unit Verification” (according to
Annex X of the European Directive 95/16/EC) of the electrical or hydraulic lift
installation (in accordance with the requirements of Annex I of the European
Directive 95/16/EC as it was adopted by National Legislation with the Common
Ministerial Decision oik.32803/1308/97 (Government Gazette issue 815B/1997))—
(Annex 10)
9.3 Certificate of “Final Inspection” (Annex VI of the European Directive 95/16/EC) of the
electrical or hydraulic lift installation (in accordance with the requirements of Annex I
of the European Directive 95/16/EC as it was adopted by National Legislation with the
Common Ministerial Decision oik.32803/1308 (Government Gazette issue
815B/1997))—(Annex 11)
9.4 Production Quality Assurance System Certificate (in accordance with Annex XIV,
Module D, Directive 95/16/EC)—(Annex 12)
9.5 Product Quality Assurance System Certificate of “Lifts” (in accordance with Annex
XII, Module E, Directive 95/16/EC)—(Annex 13)
9.6 Full Quality Assurance System Certificate (in accordance with Annex XIII, Module H,
Directive 95/16/EC)—(Annex 14)
9.7 EC Type Examination Certificate (in accordance with Annex V, Module B, Directive
95/16/EC) of electrical / hydraulic lift (according to the requirements of Annex I and
V of the European Directive 95/16/EC as it was adopted by National Legislation with
the Common Ministerial Decision oik.32803/1308 (Government Gazette issue
815B/1997))—(Annex 15).
9.8 Certificate of Periodic Inspection of electrical/hydraulic lift installation (according to
the requirements of the Common Ministerial Decision No Φ9.2/28425 (Government
Gazette issue 2604B/2008))—(Annex 16)
ESYD Assessor examines the dossier of the manufacturer/installer at the Body premises.
The body report for the decision for the EC Type Examination Certificate Issue,
along with the application and the manufacturer’s quality system concerning module
D and
The application and the manufacturer’s quality system, including product design and
respective test reports, concerning module H.
The onsite assessment by ESYD Assessor includes the evaluation of the Notified Body
inspection at the manufacturer/installer premises.
The quality assurance system requires procedures that allow the supervision of the system
from the design phase to the final inspection.
ESYD Assessor examines the method with which the organization evaluates the quality
assurance system to determine whether it complies with the directive requirements.
During the assessment conducted by ESYD concerning the Directive 95/16/EC “Lifts”,
according to annexes IX & XIII (Module H) “Full Quality Assurance” for lifts and safety
components, the ESYD assessor will examine how the body evaluates the quality assurance
system to determine whether it complies with the directive requirements.
ANNEX 1
Obligations under essential health and safety requirements apply only where the lift or
safety component is subject to the hazard in question when the specific lift or safety
component is used as intended by the installer of the lift or the manufacturer of the safety
components.
The safety-component manufacturer and the installer of the lift are under an obligation to
assess the hazards in order to identify all those which apply to their products; they must
then design and construct them taking account of the assessment.
In accordance with Article 14, the essential requirements laid down in Directive 89/106/EEC,
not included in this Directive, apply to lifts.
Where the relevant hazard exists and is not dealt with in this Annex, the essential health
and safety requirements of Annex I to Directive 89/392/EEC apply.
1. CAR
The car must be designed and constructed to offer the space and strength corresponding to
the maximum number of persons and the rated load of the lift set by the installer.
Where the lift is intended for the transport of persons, and where its dimensions permit, the
car must be designed and constructed in such a way that its structural features do not
obstruct or impede access and use by disabled persons and so as to allow any appropriate
adjustments intended to facilitate its use by them.
The means of suspension and/or support of the car, its attachments and any terminal parts
thereof must be selected and designed so as to ensure an adequate level of overall safety
and to minimize the risk of the car falling, taking into account the conditions of use, the
materials used and the conditions of manufacture.
Where ropes or chains are used to suspend the car, there must be at least two independent
cables or chains, each with its own anchorage system. Such ropes and chains must have
no joins or splices except where necessary for fixing or forming a loop.
Lifts must be so designed, constructed and installed as to prevent normal starting if the
rated load is exceeded.
Lifts must be equipped with an over speed governor. These requirements do not apply to
lifts in which the design of the drive system prevents over speed.
Lifts driven by friction pulleys must be designed so as to ensure stability of the traction
cables on the pulley.
……………………………………………….
Controls
1.6.1. The controls of lifts intended for use by unaccompanied disabled persons must be
designed and located accordingly.
- there can be no possible confusion with circuits which do not have any direct
connection with the lift,
- a fault in the electrical installation does not give rise to a dangerous situation.
2.1. The lift must be designed and constructed to ensure that the space in which the car
travels is inaccessible except for maintenance or in emergencies. Before a person enters
that space, normal use of the lift must be made impossible.
2.2. The lift must be designed and constructed to prevent the risk of crushing when the car
is in one of its extreme positions.
The objective will be achieved by means of free space or refuge beyond the extreme
positions.
………………………………….
3.1. …………………………………
The doors of the car must remain closed and interlocked if the lift stops between two levels
where there is a risk of a fall between the car and the shaft or if there is no shaft or where
there is no shaft.
3.2. In the event of a power cut or failure of components the lift must have devices to
prevent free fall or uncontrolled upward movements of the car.
………………………………….
4. OTHER HAZARDS
………………………………………..
4.2. Landing doors, where they have to contribute to the protection of the building against
fire, including those with glass parts, must be suitably resistant to fire in terms of their
integrity and their properties with regard to insulation (containment of flames) and the
transmission of heat (thermal radiation).
4.3. Counterweights must be so installed as to avoid any risk of colliding with or falling on to
the car.
4.4. Lifts must be equipped with means enabling people trapped in the car to be released
and evacuated.
4.5. Cars must be fitted with two-way means of communication allowing permanent contact
with a rescue service.
……………………………………………………….
4.7. Cars must be designed and constructed to ensure sufficient ventilation for passengers,
even in the event of a prolonged stoppage.
4.8. The car should be adequately lit whenever in use or whenever a door is opened; there
must also be emergency lighting.
4.9. The means of communication referred to in Section 4.5 and the emergency lighting
referred to in Section 4.8 must be designed and constructed so as to function even without
the normal power supply. Their period of operation should be long enough to allow normal
operation of the rescue procedure.
………………………………………………..
- assembly,
- connection,
- adjustment, and
…………………………………………………………………….
ANNEX 2
INITIAL INSPECTION CHECKLIST FOR NEW ELECTRICAL LIFTS
According to directive 95/16/EC, Common ministerial decision oik. 32803/1308/97,
(G.G 815/Β/97)
From 01.01.2012 there is mandatory implementation for new lifts including
amendment A3
INSPECTION
SPECIFICATIONS
INSPECTION STANDARD:
ELOT ΕΝ 81.1 / 1999 +Α3:2010
EC TYPE EXAMINATION:
………………………….
DESIGN EXAMINATION
Motor Technical Characteristics:
(RISK ASSESSMENT):
.…………….. MOTOR:
Installation Company
………………………… • Manufacturer……………………..
Installer • Type………………………………
• Power (KW) …...................……..
…………………….. • Rated Load:……………kg / Rated Speed………….(m/sec)
Installation Address: • Serial number /Year of Manufacture
……………………………….. • RPM ………………..
• SPH (Starts per hour)
Owner/Manager:
…………………………
GEAR:
Serial Number: • Manufacturer………………………
………………………… • Type …………………………………………………..………..
Installation Year: • Serial number /Year of Manufacture…………………………….
………………………… • Gear Ratio………………………………………
(In case there is no gear, respective technical characteristics
Inspector: must be recorded)
…………………………
NAME: TRACTION SHEAVE:
………………………………..
Eva
luat
Inspection Item Observations
ion
Requirements
1 1: Acceptable
Α. MACHINE ROOM - PULLEY 2 2: Deviation / Absence
ROOM
1. Visual Inspection
Eva
Inspection Item Requirements luat Observations
ion
1.4 Foreign Installations • Pipes, cables (not related
with the lift)
• Other equipment
Eva
Inspection Item Requirements luat Observations
ion
1.7 Stop Indications • Wire Rope Markings
Directions of car movement • Car movement direction
marked on steering hand
wheel or at the traction
pulley
Eva
Inspection Item Requirements luat Observations
ion
1.11 Electric lighting supplies to • Independent of the
the car and the well (220V) supply to the controller
• Switch, fuse (type, size)
• Circuit Breaker (if
required)
2. Measurements Requirements
Eva
Inspection Item Requirements luat Observations
ion
Eva
Inspection Item Requirements luat Observations
ion
Eval
Inspection Item Requirements uati Observations
on
Eval
Inspection Item Requirements uati Observations
on
Eval
Inspection Item Requirements uati Observations
on
Β. CAR Requirements
1. General • Signs/Labels for goods
people, maximum load
• Serial number, year of
installation
• Floor buttons
• Floor level indication
(electronic or other)
• Ventilation opening (1%
of the horizontal section
of the well up and down)
• Wall – floor mechanical
strength
(30 daN to 5 cm2)
• Car Dimensions (length,
width, height)
• Car lighting (min 50 lux)
• According to mechanical
drawing
Eval
Inspection Item Requirements uati Observations
on
1.10b Counterweight • Manufacturer
safety gear (If applicable) • Type
• CE Marking
• Serial Number / year of
manufacture
• Range
• Conformity with technical
dossier
• Fixing on the suspension
frame of the
counterweight
• Electrical Contact
(fixing - means of
activation)
Eval
Inspection Item Requirements uati Observations
on
2. Measurements Requirements
• The width shall be at
least equal to that of
the counterweight or
balancing weight plus
0,10 m on each side.
2.1 Headroom /Overhead • Height of headroom
(from the finished floor
of the top landing up to
the lowest point of the
well)
• Calculation of the free
height when
counterweight
compresses buffers.
• The free vertical distance
between the level of the
highest area on the car
roof and the level of the
lowest part of the ceiling
of the well (including
beams and components
located under the ceiling)
situated in the projection
of the car, expressed in
meters shall be at least
1,0 m + 0,035 v2
• Rectangular block not
less than 0,50 m x 0,60
m x 0,80 m on car top
• Min guide rail length
from sliding shoe shall
be at least 0,1 + 0,035
v2 m
• The highest pieces of
equipment fixed on the
roof of the car enclosure,
shall be at least 0,3 +
0,035 v2 m
2.2 Pit Clearances • Pit depth
When the car rests on its
fully compressed buffers
• The free vertical distance
between the bottom of
the pit and the lowest
parts of the car, shall be
at least 0,50 m
• Rectangular block not
less than 0,50 m x 0,60
m x 1,0 m
Eval
Inspection Item Requirements uati Observations
on
2.3 Car Buffers • Number, dimensions
• Impact test with nominal
load in the car
• For hydraulic buffers
impact test with nominal
speed.
• Manufacturer
• Type
• CE Marking
• Serial Number/year of
manufacture
• Characteristics / range
of application
• In accordance with the
technical dossier
Eval
Inspection Item Requirements uati Observations
on
3. Operational Tests Requirements
3.1 Top of Car Inspection • The Inspection-normal
switch and the STOP
switch, shall be bi-stable
and protected against
involuntary operation
Engagement of the • The up and down
inspection operation shall movement push buttons
neutralize shall operate under
the normal operation constant pressure
controls • Engagement of the
inspection operation shall
neutralize the operation
of any automatic power
operated doors and
internal and external
calls
• Emergency alarm device
for the person
conducting maintenance
& a socket outlet
3.2 Hoist way doors • Height at least 2m
(S1)
Α. «The owners or building administrators or their legal representatives are able for safety
reasons to make provisions for a telephone connection of the lift car with a telecommunications
provider» (paragraph 5 of article 8 of Common Ministerial Decision No F.Α/9.2/ΟΙΚ.28425 (G.G
2604Β/2008))”
Β. «In case of lifts used by the public the telephone connection existence and its operation is
mandatory from 1.7.2009» (paragraph 6 of article 8 of Common Ministerial Decision No
F.A/9.2/ΟΙΚ.28425 (G.G 2604Β/2008))»
OBSERVATIONS:
The Inspector
Specialty
………………………………..
ANNEX 3
INITIAL INSPECTION CHECKLIST FOR NEW HYDRAULIC LIFTS
According to directive 95/16/EC, Common ministerial decision oik. 32803/1308/97,
(G.G 815/Β/97)
From 01.01.2012 there is mandatory implementation for new lifts including
amendment A3
INSPECTION
SPECIFICATIONS
INSPECTION STANDARD: Hydraulic aggregate technical characteristics:
ELOT ΕΝ 81.2 / 1999
+Α3:2010 OIL TANK:
EC TYPE EXAMINATION: - Manufacturer …………………………………………………..
…………………………. - Type ……………………………………………………
DESIGN EXAMINATION - Serial Number/Year of manufacture…………………………
(RISK ASSESSMENT): CONTROL VALVE:
.…………….. - Manufacturer……………………………………………………
Installation Company - Type………………………………………………………………
………………………… PUMP:
Installer - Manufacturer…………………………………………………….
- Supply …………………………………………………………….
…………………….. FACTORY ADJUSTMENTS:
Installation Address: - Min static pressure………………………………………….
……………………………….. - Max static pressure……………………………………………
- Relief pressure:………………………………………………
Owner/Manager:
- Oil viscosity……………………………………………………..
…………………………
MOTOR:
Serial Number: - Power ……………………………………………………………….
………………………… - Nominal Current………………………………………………..
Installation Year: - Starting Current………………………………………………….
………………………… - Start Up type………………………………………………….
- Voltage……………………………………………………………….
Inspector: - Serial Number…………………………………………........……
…………………………
NAME:
………………………………..
SPECIALITY:
………………………………..
Inspection Date:
………………………………..
Evalu
Inspection Item Observations
ation
Requirements 1 1: Acceptable
Α. MACHINE ROOM/ 2 2: Deviation/ absence
PULLEY ROOM
Evalu
Inspection Item Requirements Observations
ation
1. Visual Inspection
Evalu
Inspection Item Requirements Observations
ation
1.5 Existence of equipment in • Lighting switch and
machine room socket outlet within the
machine room
• Acoustic communication
between the car and
the machine room
Evalu
Inspection Item Requirements Observations
ation
1.9 Controller (Electrical parts • Manufacturer
in a closed cabinet) • Controller Data
• According to electrical
drawing
• Phase monitoring • Independent grounding
connection
• Approved materials
• Safeties, fuses, wiring
connections
• Landing indication
(independent power
supply)
• Check of absence of
missing phase – phase
reversal
1.10 Main Switches (380V) • Main switch lockable at
OFF position
• Fuses (type, size)
• Supply Cables
(Diameters)
Evalu
Inspection Item Requirements Observations
ation
1.14 Pulley Room • Pulley space inside
or outside of the well
• Building
Infrastructure
• Dimensions
• Safety Distances
• Doors and trap doors
• Other openings
• Light switch & socket
outlet
1.15 Control of inspection • Location
operation • Number
• Locks
• Switch devices
2. Measurements Requirements
2.1 Insulation Resistance of • >0,5 ΜΩ for the power
power and inspection circuits circuit (test voltage
500V)
• >0,25ΜΩ for safety
operation circuits (test
voltage 250V)
Evalu
Inspection Item Requirements Observations
ation
3. TESTS Requirements
3.1 Limit switch Operation • Activation from the piston
(Up direction) for indirect suspension
• Upon activation it stops
the motor and it remains
stopped throughout the
over run
• Return to initial position
after the removement of
the activation means
• After the operation of the
final limit switches, the
return to service of the lift
shall not occur
automatically.
Evalu
Inspection Item Requirements Observations
ation
3.5 Rupture valve • Operational test with
nominal load in the car
and overspeed
• Comparison with
manufacturers adjustment
diagrams
• Manufacturer
• Type
• CE Marking
• Serial Number /Year of
manufacture
• Activation supply
3.6 Pressure and leak • In the hydraulic system a
test pressure of 200 % full
load pressure is applied
between the non-return
valve and the jack
included during a period
of 5 min
3.7 Testing for • With nominal load in car
transposition -plunging for 10 min (<10mm)
Evalu
Inspection Item Requirements Observations
ation
3.14 Machine room • Verification of the
grounding electrical continuity of
the connection
between the main
earth terminal of the
machinery spaces and
the different parts of
the lift liable to be
made live accidentally
Β. CAR
1. General • Signs/ Labels for goods
people, maximum load
• Serial number, year of
installation
• Floor buttons
• Floor level indication
(electronic or other)
• Ventilation opening
(1% of the horizontal
section of the well up
and down)
• Wall – floor
mechanical strength
(30 daN to 5 cm2)
• Car Dimentions
(length, width, height)
• Car lighting (min 50
lux)
• According to
mechanical drawing
Evalu
Inspection Item Requirements Observations
ation
2. Entrance doors • According to mechanical
drawing
• Door type
• Dimensions W x H
• Mechanical strength (30
daN to 5 cm2)
• Door Closing force (max
15 daN)
• Automatic door opening
in case of obstacle
(automatic)
• Panel guiding or hinges
• When closed, the
clearance between
panels, or between
panels and uprights,
lintels or sills, shall be
max.10 mm
• Detectors & photocells
(automatic)
• If doors are automatic
power operated a device
permitting the closing
movement to be
reversed shall be located
with the other car
controls
• At door zone when
unlocking is possible, to
allow the entering and
exiting at the
corresponding level
under the provisions of
14.2.1.2
3. Emergency lighting • Emergency Lighting
and emergency call • Emergency Alarm device
• Two-way voice
communication device
allowing permanent
contact with a rescue
service (S1). (Testing)
4. Apron under the • Apron extending to the
landing entrance full width of landing
entrance, of 75cm height.
Min angle 60° at edge
• Mechanical strength
5. Automatic rescue • It does not operate with
(where applicable) door opening (car or
hoistway) and in
maintenance.
6. Indication and test of • 10% of the nominal load
overload (max. 75 kg)
• No movement of the car
• Audible and/or a visible
signal in the car
Evalu
Inspection Item Requirements Observations
ation
7. Unintended car • Electrical –mechanical
movement means
• Type examination
certificate
• The means shall be
capable of performing
as required without
assistance from any lift
component that, during
normal operation,
controls the speed or
retardation, stops the
car or keeps it stopped,
unless there is built-in
redundancy and correct
operation is self-
monitored
• Operation Manual
8. Clearances between Measurements according
car and wall facing the to 11.2.4
car entrance
Evalu
Inspection Item Requirements Observations
ation
11. Car stopping • The means shall operate
element an electric safety device
in conformity with
(PESSRAL with safety
integrity level SIL1-SIL
3) if it is engaged
• The release of the
means shall not require
the access to the car or
the counterweight
• When the means has
been activated, its
release or the reset of
the lift shall require the
intervention of a
competent person.
12. Tests
12.1 Stopping Distances The means shall stop the
car in a distance:
These values shall be
obtained with any load in
the car, up to 100 % of
rated load as follows:
Not exceeding 1,20 m
from the landing where
the unintended car
movement has been
detected, and
The vertical distance
between the landing sill
and the lowest part of the
car apron shall not exceed
200 mm, and
The free distance from car
sill to landing door lintel,
or from landing sill to car
door lintel shall not be less
than 1,00 m.
12.2 Monitoring device • Electric Safety
for unintended car switch or circuit
movement (PESSRAL min SIL2)
• The unintended
movement of the
car shall be
detected by at latest
when the car leaves
the unlocking zone.
Evalu
Inspection Item Requirements Observations
ation
12.3. Operational tests Operational tests of the
following devices, if
available:
• Mechanical device to
prevent any dangerous
movement of the car
(6.4.3.1),
• Permanently installed
device shall be
provided to
mechanically stop the
car with any load up to
rated load and from
any speed up to rated
speed (6.4.4.1).
• The necessary devices
for emergency
operation and for
dynamic shall be
arranged so that they
can be carried out
from outside of the
well
• Platform (6.4.5),
• The car shall be
stationary by using a
mechanical device
(6.4.5.2),
• Devices for emergency
and test operations
(6.6).
Evalu
Inspection Item Requirements Observations
ation
C. HOIST WAY Requirements
1. Visual Inspection
1.1 Lighting • The well shall be provided
with permanently
installed electric lighting,
giving an intensity of
illumination of at least 50
lux
• This lighting shall
comprise one lamp at
most 0,50 m from the
highest and lowest points
in the well with
intermediate lamp(s)
1.2 Ventilation • Min Opening at the top of
the well, with a minimum
area of 1 % of the
horizontal section of the
well
1.3 Walls, distances from • Fire proofed of mechanical
car, openings strength
• 15cm max. Distance from
car sill may be extended
to 20cm for max height
50cm
• Below each landing door
sill the wall of the lift well
shall form a vertical
surface whose height is at
least equal to the
unlocking zone
1.4 Foreign Installations • Pipes, cables (not related
with the lift)
• Provisions shall be
made in order to avoid
interferance to the lift
operation with other
equipment.
1.5 Existence of more than • Partition extending
one lift in a common well through the whole height
of the well if distances
between moving parts
<50cm
• Partition of height 2.5m
above the floor of lowest
landing if distance
between moving parts
>50cm
• For a perforated partition
according to § 5.6 ELOT
ΕΝ 81.2:1999
1.6 Inspection of • Dimensions
emergency doors • Suitable lock (panic)
• Electric Safety devices
Eval
Inspection Item Requirements uatio Observations
n
1.7 Ram stroke-cylinder • Support/Fixing
• Leak testing
• Overfloating pipe
• Dimensions
• Label data
Eval
Inspection Item Requirements uati Observations
on
1.11 Safety gear • Manufacturer
• Type
• CE Marking
• Serial Number / year of
manufacture
• Range
• Fixing on the suspension frame
• Electrical Contact
(fixing - means of activation)
• Marking from the safety gear
equal/unified on both guide rails
2. Measurements Requirements
The width shall be at least
equal to that of the
counterweight or balancing
weight plus 0,10 m on each
side.
Eval
Inspection Item Requirements uati Observations
on
2.1 Headroom/Overhead • Height of headroom (from the
finished floor of the top landing
up to the lowest point of the
well). Calculation of the free
height when the piston has fully
extended.
• The free vertical distance
between the level of the highest
area on the car roof and the
level of the lowest part of the
ceiling of the well (including
beams and components located
under the ceiling) situated in the
projection of the car, expressed
in meters shall be at least 1,0 +
0,035 v2
• Rectangular block not less than
0,50 m x 0,60 m x 0,80 m on
car top
• Min guide rail length from sliding
shoe shall be at least 0,1 +
0,035 v2 m
• The highest pieces of equipment
fixed on the roof of the car
enclosure, shall be at least 0,3
+ 0,035 v2 m
2.2 Pit Clearances • Pit depth
When the car rests on its fully
compressed buffers
• The free vertical distance
between the bottom of the pit
and the lowest parts of the car,
shall be at least 0,50 m
• Rectangular block not less than
0,50 m x 0,60 m x 1,0 m
2.3 Buffers • Manufacturer
• Type
• CE Marking
• Serial Number/year of
manufacture
• Number, dimensions
• Impact test with nominal load in
the car
• Car immersion max 12cm from
landing
2.4 Car, piston guiderails • Dimensions of car guide rails
• Max distance between guide rail
supports ( l )
• Guide rail supports
• Dimensions of piston guide rails
2.5 Checking of grounding • Between the metallic parts of
continuity the lift.
Eval
Inspection Item Requirements uati Observations
on
3. Operational tests
3.1 Top of car inspection • The Inspection-normal switch
and the STOP switch, shall be
bi-stable
• The up and down movement
push buttons shall operate
under constant pressure
• Engagement of the inspection
operation shall neutralize the
operation of any automatic
power operated doors and
internal and external calls and
relevelling
• Emergency alarm device for the
person conducting maintenance
• Socket outlet
3.2 Hoistway doors • Height at least 2m
(S1)
Α. «The owners or building administrators or their legal representatives are able for safety
reasons to make provisions for a telephone connection of the lift car with a telecommunications
provider» (paragraph 5 of article 8 of Common Ministerial Decision No F.Α/9.2/ΟΙΚ.28425 (G.G
2604Β/2008))”
Β. «In case of lifts used by the public the telephone connection existence and its operation is
mandatory from 1.7.2009» (paragraph 6 of article 8 of Common Ministerial Decision No
F.A/9.2/ΟΙΚ.28425 (G.G 2604Β/2008))»
OBSERVATIONS:
The Inspector
Specialty
………………………………..
ANNEX 4
PERIODIC INSPECTION CHECKLIST FOR EXISTING ELECTRICAL LIFTS
According to Common ministerial decision οικ.F.A/9.2/oik.28425 (G.G 2604Β/2008)
and the standard ELOT ΕΝ 81.1/1988
INSPECTION
SPECIFICATIONS
INSPECTION STANDARD:
ELOT ΕΝ 81.1 / 1988
INSTALLATION COMPANY
…………………………
Motor Technical Characteristics:
INSTALLER
MOTOR:
………………………………
Installation address: • Manufacturer……………………..
• Type………………………………
……………………………….. • Power (KW) …...................……..
Owner/Building administrator: • Rated Load:……………kg / Rated Speed………….(m/sec)
• Serial number /Year of Manufacture
………………………… • RPM ………………..
• SPH (Starts per hour)
Inspection date:
………………………………..
Eval
Inspection Item uati Observations
Requirements on
1 1: Acceptable
Α. MACHINEROOM 2 2: Deviation/ absence
1. Visual Inspection
1.1 Machine room location • Upstairs/ Downstairs
• Floor or elsewhere or
without
• Sign
1.2 Entrance door • Height 1,80m, Width
0,60m
• Outwards opening
Eval
Inspection Item Requirements uatio Observations
n
1.6 Motor • Motor alignment, oil level,
leakage, brake release
smooth, spokeless wheel.
• Traction /deflection • There shall be a clear
Sheaves vertical distance of at least
0,30 m above the rotating
parts of the machine.
• diameter ≥ 40xD of the
ropes
• Protections
• State of traction sheave
grooves
• Breaking System • Devices against Rope
Deflection
• Double independent
brakes,
• Fixings, springs, safeties,
sustained action wheel.
Eval
Inspection Item Requirements uati Observations
on
1.10 Main Switches • Main switch
(380V) (S4) • Fuses (type, size)
• Supply Cables (Diameters)
Eval
Inspection Item Requirements uati Observations
on
3. Tets Requirements
3.1 Limit Switches • Upon activation they
operation (up & down) open the electric safety
circuit
Immediate activation after • Return to initial position
the final stops after the means of
activation have been
removed
• After the operation of the
final limit switches, the
return to service of the
lift shall not occur
automatically.
3.2 Safety Gear / Speed • Down direction with out
Governor load and nominal speed
• Test from speed
3.2.1 Down movement governor
control • Test Governor tripping
speed
• A tripping device shall be
3.2.1.1. Instantaneous provided in the
Safety gear machineroom for
engaging and
disengaging the speed
3.2.1.2. Progressive safety governor when it is not
gear accessible
Eval
Inspection Item Requirements uati Observations
on
3.2.2 Protection against • Bidirectional safety gear
overspeed during ascend for the car engaged by a
(S2) suitable speed governor,
or
• Safety gear for the
counterweight engaged
by a suitable speed
governor, or
• Gearless motor, or
• Additional
electromechanical brake
on the traction pulley of
the machine, or
• Additional
electromechanical brake
on the suspension wire
ropes
3.3 Traction ability of the • Brake with empty car
traction sheave while ascending (max
sliding 1cm/stop)
Eval
Inspection Item Requirements uati Observations
on
3.6 Testing of brakes • During ascend with
(Double autonomus nominal speed for each
brakes). jaw separately
• When the force for
moving the car with
3.7 Cirquit reset handling nominal load through
the wheel is greater
than 40 Kg.
Eval
Inspection Item Requirements uati Observations
on
2. Entrance doors • According to mechanical
drawing
• Door type
• Dimensions W x H
• Mechanical strength (30
daN to 5 cm2)
• No permanent
deformation
• No elastic deformation
≤15mm
• Door Closing force (max
15 daN) (automatic)
• Automatic door opening
in case of obstacle
(automatic)
• Electrical contacts
• Panel guiding or hinges
• When closed, the
clearance between
panels, or between
panels and uprights,
lintels or sills, shall be
max.10 mm
• Detectors & photocells
(automatic)
• If doors are automatic
power operated a device
permitting the closing
movement to be
reversed shall be located
with the other car
controls
Eval
Inspection Item Requirements uati Observations
on
3. Emergency lighting and • Emergency Lighting
emergency call • Emergency Alarm device
• Two-way voice
communication device
allowing permanent contact
with a rescue service.
(Testing) (S3)
4. Apron under the landing • Apron extending to the full
entrance width of landing entrance,
of 75cm height. Min angle
60° at edge
• Mechanical strength
C. HOIST WAY Requirements
1. Visual Inspection/
Measurements
1.1 Lighting • The well shall be provided
with permanently installed
electric lighting, this
lighting shall comprise one
lamp at most 0,50 m from
the highest and lowest
points in the well with
intermediate lamp(s) every
7m
1.2 Ventilation • Min Opening at the top of
the well, with a minimum
area of 1 % of the
horizontal section of the
well
1.3 Walls, Distances from • Fire proofed of mechanical
car, openings strength
• 15cm max. Distance from
car sill may be extended to
20cm for max height 50cm
• Below each landing door sill
the wall of the lift well shall
form a vertical surface
whose height is at least
equal to the unlocking zone
1.4 Foreign Installations • Pipes, cables (not related
with the lift)
1.5 Existence of more than • Partition extending through
one lift in a common well the whole height of the
well if distances between
moving parts <30cm
• Partition of height 2.5m
above the floor of lowest
landing if distance between
moving parts >30cm
Eval
Inspection Item Requirements uati Observations
on
1.6 Inspection or • Dimensions
emergency doors • Suitable lock (panic)
• Electric Safety devices
Eval
Inspection Item Requirements uati Observations
on
1.12 Tension pulley of the • Fixing - cover
overspeed governor • Control slack rope switch
for wire ropes
2. Measurements Requirements
2.1 Headroom/Overhead • Height of headroom
(from the finished floor
of the top landing up to
the lowest point of the
well)
• Calculation of the free
height when
counterweight
compresses buffers:
• The free vertical distance
between the level of the
highest area on the car
roof and the level of the
lowest part of the ceiling
of the well (including
beams and components
located under the ceiling)
situated in the projection
of the car, expressed in
meters shall be at least
1,0 + 0,035 v2
• Rectangular block not
less than 0,50 m x 0,60
m x 0,80 m on car top
• Min guide rail length
from sliding shoe shall
be at least 0,1 + 0,035
v2 m
• The highest pieces of
equipment fixed on the
roof of the car enclosure,
shall be at least 0,3 +
0,035 v2 m
• In case the overhead
dimensions required by
the standard ΕΝ
81.1/1998 do not exist
the corresponding
arrangements of the
standard prEN
81.21/2003 shall be
applied (S2)
Eval
Inspection Item Requirements uati Observations
on
2.2 Pit Clearances • Pit depth
Eval
Inspection Item Requirements uati Observations
on
3. Operational tests Requirements
3.1 Top of car inspection • The Inspection-normal
switch and the STOP
switch, shall be bi-stable
and protected against
involuntary operation
Engagement of the • The up and down
inspection operation shall movement push buttons
neutralize the normal shall operate under
operation controls constant pressure
• Engagement of the
inspection operation shall
neutralize the operation
of any automatic power
operated doors and
internal and external
calls
• Emergency alarm device
for the person
conducting maintenance
• A socket outlet
3.2 Hoistway doors • Height at least 2m
3.2.1 Automatic-Manual • The door panels are
connected and moving
on the door driving
element
• Test the stopping of the
lift movement when the
contacts of the door
open
• Emergency release key
(triangular key)
• Type
• Dimensions
• Mechanical strength
• Support
• Gaps (max. 10mm)
3.2.2 Door closing force Springs, hinges
test (swing /semi-auto)
3.2.3 An illuminated “car
here” signal 50 Lux
(S1) In case or safety components replacement after 01.07.1999, they should comply with the
requirements of the directive 95/16/EC.
(S2) Mandatory for inspections conducted at lifts of part (c) of paragraph 4 of article 4 of the
Common Ministerial Decision οικ.F.A/9.2/ΟΙΚ.28425 (G.G 2604Β/2008), thus at lifts at public areas
or lifts accessible to the public in general.
(S3)
Α. «The owners or building administrators or their legal representatives are able for safety
reasons to make provisions for a telephone connection of the lift car with a telecommunications
provider» (paragraph 5 of article 8 of Common Ministerial Decision No F.Α/9.2/ΟΙΚ.28425 (G.G
2604Β/2008))”
Β. «In case of lifts used by the public the telephone connection existence and its operation is
mandatory from 1.7.2009» (paragraph 6 of article 8 of Common Ministerial Decision No
F.A/9.2/ΟΙΚ.28425 (G.G 2604Β/2008))»
(S4) In case of electrical wiring or equipment replacement the respective applicable regulations for
internal electrical installations shall be applied.
OBSERVATIONS:
The inspector
NAME
………………………………..
SPECIALITY
………………………………..
ANNEX 5
PERIODIC INSPECTION CHECKLIST FOR EXISTING HYDRAULIC LIFTS
According to Common Ministerial Decision oik.F.A/9.2/oik.28425 (G.G 2604Β/2008)
And the standard ELOT ΕΝ 81.2/1990
INSPECTION
SPECIFICATIONS
ELOT ΕΝ 81.2:1990
DESIGN EXAMINATION
(RISK ASSESSMENT) (When
needed):.……………..
INSTALLATION COMPANY
…………………………
Hydraulic aggregate technical characteristics:
INSTALLER
OIL TANK:
…………………………. - Manufacturer …………………………………………………..
Installation address: - Type ……………………………………………………
- Serial Number/Year of
……………………………….. manufacture…………………………
Owner/Building administrator: CONTROL VALVE:
- Manufacturer……………………………………………………
………………………….. - Type………………………………………………………………
PUMP:
- Manufacturer…………………………………………………….
- Supply …………………………………………………………….
Installation year: FACTORY ADJUSTMENTS:
………………………… - Min static pressure………………………………………….
With installation license - Max static pressure……………………………………………
(authorities dossier - Releaf pressure:………………………………………………
number) - Oil viscosity……………………………………………………..
or MOTOR:
with a preliminary - Power ……………………………………………………………….
installation approval - Nominal Current………………………………………………..
(authorities dossier - Starting Current………………………………………………….
number) - Start Up type………………………………………………….
or - Voltage……………………………………………………………….
with an operation license - Serial Number…………………………………………........……
(authorities dossier
number)
or
without legalization
documents
Inspector:
…………………………
Inspection date:
………………………………..
Evalu
Inspection Item ation Observations
Requirements
1 1: Acceptable
Α. MACHINEROOM 2 2: Deviation/ absence
1. Visual Inspection
1.1 Machineroom • Upstairs/ Downstairs
location………… • Floor or elsewhere
Evalu
Inspection Item Requirements Observations
ation
1.2 Entrance door • Sign
• Height 1,80m, Width
0,60m
• Outwards opening
Evalu
Inspection Item Requirements Observations
ation
1.9 Controller (Electrical • Manufacturer
parts in a closed cabinet) • Controller data
(S4) • According to electrical
drawing
• Independent grounding
Phase Monitoring connection
• Approved materials
• Safeties, fuses, wiring
connections
• Landing Indication
(independent power
supply)
• Check of absence of
missing phase – phase
reversal
1.10 Main Switches (380V) • Main switch
(S4) • Fuses (type, size)
• Supply Cables
(Diameters)
Evalu
Inspection Item Requirements Observations
ation
3. TESTS Requirements
Evalu
Inspection Item Requirements Observations
ation
3.8 Electrical Anti-creep • The car shall be
system dispatched automatically
to the lowest landing
within 15 min
• It should not operate
during maintenance
3.9 Electrical leakage • Type of protections (fuses,
testing & testing of the circuit breaker)
movement stopping with
short circuit
3.10 Pressure relief valve • Operation test
Max adjustment 1,4 of
Handpump overpressure Pstat
test • 2,3 of Pst
3.11 Run time limiter • The machine does not
rotate when a start is
initiated
• Activation within 20-45
sec
• It shall not affect the
service operation and
relevelling
• Return to normal
operation manually
3.12 Motor temperature • The car shall stop
monitoring device immediately
(machine & oil) • An automatic return to
normal operation of the
lift shall only occur after
sufficient cooling down
within acceptable limits
Requirements
Β. CAR
1. General • Signs /Labels for goods
people, maximum load
• Floor buttons
• Floor level indication
(electronic or other)
• Ventilation opening
• Wall – floor mechanical
strength (30 daN to 5
cm2)
• Car Dimensions (length,
width, height)
• Car lighting (min 50 lux)
• According to mechanical
drawing
Evalu
Inspection Item Requirements Observations
ation
2. Entrance Doors • According to mechanical
drawing
• Door type
• Dimensions W x H
• Mechanical strength (30
daN to 5 cm2)
• No permanent
deformation
• No elastic deformation
≤15mm
• Door Closing force (max
15 daN) (automatic)
• Automatic door opening in
case of obstacle
(automatic)
• Electrical contacts
• Panel guiding or hinges
• When closed, the
clearance between panels,
or between panels and
uprights, lintels or sills,
shall be max.10 mm
• Detectors & photocells
(automatic)
• If doors are automatic
power operated, a device
permitting the closing
movement to be reversed
shall be located with the
other car controls
Evalu
Inspection Item Requirements Observations
ation
3. Emergency Lighting and • Emergency Lighting
emergency call • Emergency Alarm device
• Two-way voice
communication device
allowing permanent
contact with a rescue
service (Testing) (S3)
4. Apron under the landing • Apron extending to the
entrance full width of landing
entrance, of 75cm height.
Min angle 60° at edge
• Mechanical strength
5. Automatic rescue (if • It does not operate with
applicable) door opening (car or
hoistway) and in
maintenance.
C. HOIST WAY Requirements
1. Visual Inspection
1.1 Lighting • The well shall be
provided with
permanently installed
electric lighting, this
lighting shall comprise
one lamp at most 0,50 m
from the highest and
lowest points in the well
with intermediate
lamp(s) every 7m
1.2 Ventilation • Min Opening at the top of
the well, with a minimum
area of 1 % of the
horizontal section of the
well
1.3 Walls, distances from • Fire proofed of
car, openings mechanical strength
• 15cm max. Distance from
car sill may be extended
to 20cm for max height
50cm
• Below each landing door
sill the wall of the lift well
shall form a vertical
surface whose height is
at least equal to the
unlocking zone
1.4 Foreign Installations • Pipes, cables (not related
with the lift)
Evalu
Inspection Item Requirements Observations
ation
1.5 Existence of more than • Partition extending
one lift in a common well through the whole height
of the well if distances
between moving parts
<30cm
• Partition of height 2.5m
above the floor of lowest
landing if distance
between moving parts
>30cm
Evalu
Inspection Item Requirements Observations
ation
1.11 Safety Gear (S1) • Manufacturer
• Type
• Conformity with technical
dossier
• Fixing on the suspension
frame
• Electrical Contact
(fixing - means of activation)
• Equal/unified marks on both
guide rails
1.12 Hoistway door locking • Manufacturer
devices (door locks) (S1) • Type
• Conformity with technical
dossier
• That there is at least 7 mm
engagement of the locking
elements before the electric
safety device operates
• Operational pre-locking
check
1.13 Tension pulley of the • Fixing - cover
overspeed governor (if • Control slack rope switch for
applicable) wire ropes
2. Measurements Requirements
Evalu
Inspection Item Requirements Observations
ation
2.2 Pit Clearances • Pit depth
Evalu
Inspection Item Requirements Observations
ation
3.2.1 Automatic-Manual • The door panels are •
connected and moving on
the door driving element
• Test the stopping of the lift
movement when the
contacts of the door open
• Emergency release key
(triangular key)
• Type
• Dimensions
• Mechanical strength
• Support
• Gaps (max. 10mm)
3.2.2 Door closing force • Springs, Hinges
test (swing, semi-
automatic)
3.2.3 An illuminated “car
here” signal 50 Lux
(S1) In case of safety components replacement after 01.07.1999, they should comply with the
requirements of the Directive 95/16/EC.
(S2) Mandatory for inspections conducted at lifts of part (c) of paragraph 4 of article 4 of the
Common Ministerial Decision oik.F.A/9.2/ΟΙΚ.28425 (G.G 2604Β/2008), thus at lifts at public areas
or lifts accessible to the public in general.
(S3)
Α. «The owners or building administrators or their legal representatives are able for safety
reasons to make provisions for a telephone connection of the lift car with a telecommunications
provider» (paragraph 5 of article 8 of Common Ministerial Decision No F.Α/9.2/ΟΙΚ.28425 (G.G
2604Β/2008))”
Β. «In case of lifts used by the public the telephone connection existence and its operation is
mandatory from 1.7.2009» (paragraph 6 of article 8 of Common Ministerial Decision No
F.A/9.2/ΟΙΚ.28425 (G.G 2604Β/2008))»
(S4) In case of electrical wiring or equipment replacement the respective applicable regulations for
internal electrical installations shall be applied.
OBSERVATIONS:
The inspector
NAME
………………………………..
SPECIALITY
………………………………..
ANNEX 6
PERIODIC INSPECTION CHECKLIST FOR EXISTING ELECTRICAL LIFTS
According to Common Ministerial Decision oik.F.A/9.2/oik.28425 (G.G 2604Β/2008),
and the ROYAL DECREE 37/1966 (G.G 10Α/66) & ROYAL DECREE 890/68 (G.G 311Α/68)
INSTALLATION COMPANY
………………….
INSTALLER Motor Technical Characteristics:
………………………. MOTOR:
SERVICE COMPANY
• Manufacturer……………………..
………………………… • Type………………………………
MAINTENANCE OPERATOR • Power (kW) …...................……..
• Rated Load:……………kg / Rated Speed………….(m/sec)
………………….. • Serial number /Year of Manufacture
Installation address: • RPM ………………..
……………………………….. • SPH (Starts per hour)
Owner /Building
administrator: GEAR:
………………………… • Manufacturer………………………
Number of lift (in case there • Type …………………………………………………..………..
is more than one): • Serial number /Year of Manufacture…………………………….
………………………… • Gear Ratio………………………………………
Installation Year: (In case there is no gear record respective technical
With an installation license characteristics)
(dossier number of
authorities): TRACTION SHEAVE:
or
Operation license (dossier - Diameter:………….……………… LAYOUT
number of authorities): - Angle of Wrap (α):…..………..
or - Groove Angle (γ):.………………
without legalization - Suspension:…………….
documents:
Inspector
Eval
Inspection Item uati Observations
on
Requirements
1 1: Acceptable
Α. MACHINEROOM 2 2: Deviation/absence
1. Visual Inspection
1.1 Machine room Location ..... • Upstairs/ Downstairs
• Floor or elsewhere
Eval
Inspection Item Requirements uati Observations
on
1.8 Speed Governor (Inside • Manufacturer
the machineroom or pulley • Type
room) (S1) • Tension through
Counterweight and rope
deflection protection down
• Rope Slipping at F>50kg
• Activation speed
Max 1,4x U for U<1.25m/s
Max 1.2x U for U>1.25m/s
• Rope diameter
• Electric switch
1.9 Controller (S4) • Manufacturer
• Controller data
Phase Monitoring • According to electrical
drawing
• Safeties, fuses, wiring
connections
• The lift and the brake
operation are stopped with
at least 2 independent
relays with their contacts
connected in series (S2)
• Check of absence of
missing phase
• Protection against phase
reversal (S2)
• Automatic
• Thermal contact switch
1.10 Main Switches (380V) • Main switch easily
(S4) accessible with signs
• Fuses (type, size)
• Diameters: min 1mm²
towards the car, min 1,5
mm² to the operational
circuit
Supply Cables (Diameters)
1.11 Electric lighting supplies • Independent of the supply
to the car and the well (220V) to the controller,
(S4) • Switch, fuse (type, size)
• Control Circuit voltage
max 110V
1.12 Lift booklet • Lift booklet
• Instuctions for use and
maintenance
• Instructions for emergency
operations
• Labels, notices & markings
Eval
Inspection Item Requirements uati Observations
on
1.13 PULLEY ROOM • Access without
necessitating entry into
private premises
• Door min 1.1m height
• Sing on the entrance door
• 30cm free space over
moving parts
• No foreign equipment
allowed
• Floor durability 350Kg/m²
• Lighting switch, STOP,
socket outlet max 42V
2. Measurements Requirements
2.1 Insulation Resistance of • >0,5 ΜΩ for the power
power and inspection circuits circuit (test voltage 500V)
• >0,25 ΜΩ for safety
operation circuits (test
voltage 250V)
• Grounding duct
min 16mm² at the machine
min 2.5mm² at the car (S4)
Eval
Inspection Item Requirements uati Observations
on
3. Tests
3.1 Limit Switch operation Up • Upon activation the
& Down machine & brake
(automatic) circuit are
Immediate activation after the interrupted
final stops • In Ward-Leonard
interruption of the
generator stimulation
• Return when the car is
back at normal position
• After the operation of the
final limit switches, the
return to service of the lift
shall not occur
automatically.
3.2 Safety Gear – Speed • Test without load
Governor (S1) • Safety gear & speed
governor switch
Downward movement control
They disengage the operation
(Test after visual inspection in circuit & power to the
the hoistway §C1.11) machine.
Eval
Inspection Item Requirements uati Observations
on
3.4 Traction ability of the • Braking at all stops from
traction sheave the lowest to the highest
with empty car while
(max undercut 80%D of wire ascending
ropes) • (max sliding 1cm/stop)
3.6 Sliding of the ropes over • With empty car when the
the pulley counterweight has
beseated
• The car can not be raised
when the counterweight
has fully compressed the
buffers (sliding of the
ropes over the pulley)
3.7 Electrical leakage testing & Type of protections (fuses,
short circuit testing circuit breaker)
3.8 Motor Run time limiter (S2) • The machine does not •
rotate when a start is
The return to normal operation initiated
shall only be possible by the • Activation within 20-45 sec
intervention of a competent • Does not affect the service
person (service mechanic of operation
the lift)
Β. CAR Requirements
1. General • Signs/Labels for goods •
people, maximum load
• Floor buttons
• Floor level indication
(electronic or other)
• Ventilation opening
• Wall – floor mechanical
strength
Eval
Inspection Item Requirements uati Observations
on
2. Entrance doors The lift cars must have doors in
the following cases:
• The lift has a speed faster
than 0,7 m/sec.
• When the car has 2 entrances
at least one of them should
have car doors.
• When the passenger enters
the car, the external controls
are not interrupted.
• Especially for lifts with a car
area less than 0.6 square
meters (up to 2 people) and in
the cases, as set by the
regulations, that the car is not
required to have doors, it is
possible to recommend the
use of photocells distributed
along the height of the car
entrance door.
• Door type
• Dimensions W x H
• Mechanical strength (30 daN
to 5 cm2)
• No permanent deformation
• No elastic deformation
≤15mm
• Door closing force (max 15
daN) (automatic)
• Automatic door opening in
case of obstacle (automatic)
• Electrical contacts
• Panel guiding or hinges
• When closed, the clearance
between panels, or between
panels and uprights, lintels or
sills, shall be max.10 mm
• Detectors & photocells
(automatic)
• If doors are automatic power
operated, a device permitting
the closing movement to be
reversed shall be located with
the other car controls
(when car doors exist)
Especially lifts of category (c) of
paragraph 4 of article 4 of the
Common Ministerial Decision oik.
F.A/9.2/oik.28425 (G.G
2604Β/2008), it is obligatory to
have car doors according to point
40 and paragraph 5.8.3 of the
standard ELOT ΕΝ 81.80/2004
Eval
Inspection Item Requirements uati Observations
on
3. Emergency lighting • Emergency Lighting
Emergency call • Emergency Alarm device
• Two-way voice communication
device allowing permanent
contact with a rescue service
(Testing) (S3)
Eval
Inspection Item Requirements uati Observations
on
1.7 Equipment in the pit • Counterweight partition at a
height 2.0m above the pit
• Door for pit depth > 2,0m
• Support, tension weight
Speed governor tension • Electric switch which activates
pulley in case of a governor slack rope
according to the standard ΕΝ
81.1/1998, § 9.9.11.3 (S2)
Eval
Inspection Item Requirements uati Observations
on
1.13 Hoistway doors
• Height at least 1.8m
1.14 Automatic- Manual, • The door panels are
type, dimensions, connected and moving on the
mechanical strength – door driving element
supports gaps (max 5mm) • Fire proof axes on the rollers
• In automatic doors reversal if
obstacle. Fmax 15Kg during
closing
• Test the stopping of the lift
movement when the contacts
of the door open
Openings max 800 cm² on
1.15 A “car here” signal manual doors or indication of
car presence at operating panel
2. Measurements Requirements
2.1 Headroom/Overhead • Minimum free space 70cm,
when the counterweight has
fully beseated
Upper limit of • In case the overhead
travel………………… dimensions required by the
standard ΕΝ 81.1/1998 do
not exist, the corresponding
arrangements of the standard
prEN 81.21/2003 shall be
applied (S2)
Eval
Inspection Item Requirements uati Observations
on
2.5 Checking of grounding • Between the metallic parts of
continuity the lift.
(S1) In case of safety components replacement after 01.07.1999, they should comply with the
requirements of the Directive 95/16/EC.
(S2) Mandatory for inspections conducted at lifts of part (c) of paragraph 4 of article 4 of the
Common Ministerial Decision oik.F.A/9.2/ΟΙΚ.28425 (G.G 2604Β/2008), thus at lifts at public areas
or lifts accessible to the public in general.
(S3)
Α. «The owners or building administrators or their legal representatives are able for safety
reasons to make provisions for a telephone connection of the lift car with a telecommunications
provider» (paragraph 5 of article 8 of Common Ministerial Decision No F.Α/9.2/ΟΙΚ.28425 (G.G
2604Β/2008))”
Β. «In case of lifts used by the public, the telephone connection existence and its operation is
mandatory from 1.7.2009» (paragraph 6 of article 8 of Common Ministerial Decision No
F.A/9.2/ΟΙΚ.28425 (G.G 2604Β/2008))»
(S4) In case of electrical wiring or equipment replacement, the respective applicable regulations
for internal electrical installations shall be applied.
OBSERVATIONS:
The inspector
NAME
………………………………..
SPECIALITY
………………………………..
ΑΝΝΕΧ 7
INSTALLATION OFFICE:
INSTALLER:
OWNER/BUILDING ADMINISTRATOR:
DRAWINGS-CALCULATIONS
Mechanical Drawing, at
which there shall be
indicated:
Cross section and plan of
the hoistway,
The plan of the
machineroom, the
Electrical drawings:
Power and safety circuits
with the proper symbols
and definitions (CENELEC
symbols)
Hydraulic circuit diagram
(ISO 1219-1 symbols)
(only for hydraulic lifts)
Manufacturer
declarations of
conformity for the
safety components:
Chains
Anti explosive
equipment e.t.c (where
applicable)
(In cases of annex VI, ΧΙΙ
or ΧΙV of the directive
95/16/ΕC, a list of the here
above mentioned
equipment is adequate)
ADDITIONAL DESIGN ANALYSIS
ANNEX 8
EXISTING LIFT TECHNICAL DOSSIER CHECKLIST
According to Common Ministerial Decision oik.F9.2/28425 (G.G 2604Β/2008)
INSTALLATION OFFICE:
INSTALLER:
OWNER/BUILDING ADMINISTRATOR:
INSPECTION TYPE
PERIODIC INSPECTION
AFTER A SIGNIFICANT MODIFICATION
• Change of building use
• Change of lift use
• Travel distance alteration
• Nominal load change
• Significant speed change
RD 890 / 1968
RD 37 / 1966
Type examination
GENERAL REQUIREMENTS
Application to the
inspection body
One of the following
documents (A, B, C, D,
E)
Α. Copy of the building
permit
DRAWINGS – CALCULATIONS
Mechanical Drawing, at
which there shall be
indicated:
Cross section and plan of
the hoistway,
The plan of the
machineroom, The hoisting
means and the pulleyroom
plan, if any.
In case of a hydraulic lift
the connection to the
pump shall be indicated as
well.
Electrical drawings:
Power and safety circuits
(required in case the lift
is provided only with
documents A or E or in
case of significant
modification)
Hydraulic circuit diagram
(ISO 1219-1 symbols)
(only for hydraulic lifts)
(Required in case the lift is provided only with documents A or E or in case of significant
modification and only in case the applicable technical specifications are the standards ΕΝ
81.1 or 2)
Hoisting wire ropes
Chains
Anti explosive
equipment e.t.c. (where
applicable)
ΑΝΝΕΧ 9
EC DECLARATION OF INSTALLATION CONFORMITY
CONCERNING AN ELECTRICAL/HYDRAULIC LIFT
according to the requirements of Annex II of European Directive 95/16/EC, as adopted by
the Greek Law with Common Ministerial Decision Dept. No. 32803/1308/97
(Government Gazette Issue 815Β/1997)
(Emblems of the Certification Body)
Lift Details
Certificate S/N .....................................................
............
Publication Number of the Certification.Body .....................................................
.....................................................
Owner/Building Manager (delete accordingly) .....................................................
............
Installation Location (Street, number, .....................................................
Municipality or Community) .....................................................
Year of installation .....................................................
............
Installation Supervisor (physical entity) .....................................................
............
Engineer’s Office for the Installation .....................................................
............
Applied Standard(s) .....................................................
............
Quality Assurance Procedure 1 and .....................................................
certificate(s) S/N ............
S/N of the lift’s class .....................................................
............
Lift’s Technical Specification:
Type of lift (electrical/hydraulic) ..............................................
...............
Lift for persons/ load/ small ..............................................
load (delete accordingly) ..............
1
As certification procedure, one of the points 9.2-9.6 of Chapter 9 of this Guidance should be selected.
2
Suspension Mechanism, Basic Safety Parts, Operation Speed, Switchboard, Pulleys, Pistons, Drive mechanism, Cabin doors, Travel.
ΑΝΝΕΧ 10
"UNIT VERIFICATION"
(Annex Χ, directive 95/16/EC) FOR THE INSTALLATION OF AN ELECTRICAL-
HYDRAULIC LIFT
according to the requirements of Annex I of European Directive 95/16/EC, as integrated in Greek
Law with Common Ministerial Decision Dept. No. 32803/1308/97
(Government Gazette Issue 815Β/1997)
Lift Details
Certificate S/N............................................ .....................................................
............
Publication Number of the Certification Body .....................................................
............
Owner/ Building Manager (delete accordingly) .....................................................
............................................................. ............
Installation Location (Street, number,
Municipality or Community) .....................................................
............
Installation Supervisor (physical entity) .....................................................
............................................................... ............
Engineer’s Office for the Installation .....................................................
............................................................... ............
Date of performing the Inspection .....................................................
............................................................... ............
Standard according to which the Inspection .....................................................
was performed ............
Inspection Results
Based on the inspection performed, it is determined that the above-mentioned lift installation
fulfils all the aforementioned requirements.
Remarks
It should be noted that Regular Maintenance and Periodic Inspections are prerequisites for the
operation of the lift. It should also be noted that any significant changes to the installation must
be announced and approved by the Body, following a re-inspection.
Published at............(place) on ..../..../.............(date)
The next inspection must be performed not later than ..../.../.......................
For the Body
(Full name, Stamp and Signature)
ANNEX 11
Lift Details
Certificate S/N .....................................................
............................................................... ............
Publication Number of the Certification Body .....................................................
.............................................................. ............
.....................................................
............
Owner/ Building Manager (delete accordingly) .....................................................
............................................................... ............
Installation Location (Street, number, .....................................................
Municipality/Community).......................................... ............
........................... .....................................................
............
Installation Supervisor (physical entity) .....................................................
............................................................... ............
Engineer’s office for the Installation .....................................................
............................................................... ............
Date of performing the Inspection .....................................................
............................................................... ............
Standard according to which the inspection .....................................................
was performed ............
............................................................... .....................................................
............
S/N of Inspection Report .....................................................
............................................................... ............
Inspection Results
Based on the inspection performed, it is determined that the above-mentioned lift installation
fulfils all the aforementioned requirements.
Remarks
It should be noted that Regular Maintenance and Periodic Inspection are prerequisites for
the operation of the Lift. It should also be noted that any significant changes to the
installation must be announced and approved by the Body, following a re-inspection.
Published at............(place) on ..../..../.............(date)
The next inspection must be performed not later than ..../.../.......................
For the Body
(Full name, Stamp and Signature)
ANNEX 12
DECISION - STATEMENT
The quoted organisation ........................................... certifies that the said installer has applied a quality
assurance system which satisfies the requirements of Annex XIV of Directive 95/16/EC and the relevant
standard for the
Additional information/Remarks
All amendments or modifications of the quality assurance system must be notified to
the certification body.
The quality assurance system is subject to monitoring by the certification body.
ANNEX 13
.....................................................
Certificate S/N: ............
....................................................................
Publication Number of the Certification Body .....................................................
.................................................................... ............
Name & Address of the installer: .....................................................
.....................................................
....................…
.....................................................
Type of Lift to be installed: .....................................................
.................................................................... .....................................................
..................................
.....................................................
S/N of EC Type Examination Certificate/Issuing ............
Body:
Attached documents: .....................................................
Date of submitting the evaluation Application: ............
....................................................................
Evaluation Period: .....................................................
............
Standard according to which the evaluation was .....................................................
performed ............
S/N & Date of the Evaluation Report .....................................................
............
DECISION - STATEMENT
The quoted organisation ......................................... certifies that the installer applies a quality
assurance system which satisfies the requirements of Annex XII of Directive 95/16/EC and the
relevant standard for the
FINAL INSPECTION & TESTS of the Lifts, of the type described above
Additional information/Remarks
All amendments or modifications of the quality assurance system must be notified to
the certification body.
The quality assurance system is subject to monitoring by the certification body.
ANNEX 14
DECISION - STATEMENT
The quoted organisation ......................................... certifies that the installer applies a quality
assurance system which satisfies the requirements of Annex XIII of the Directive 95/16/EC and
the relevant standard for the
DESIGN-CONSTRUCTION-ASSEMBLY-INSTALLATION-FINAL
INSPECTION & TESTS of the Lifts of the type described above
Additional information/Remarks
All amendments or modifications of the quality assurance system must be notified to
the certification body.
The quality assurance system is subject to monitoring by the certification body.
..................................................................
ANNEX 15
ELECTRICAL/HYDRAULIC LIFT
according to the requirements of Annexes I & V of European Directive 95/16/EC, as same
was integrated in the Greek Law with the Common Ministerial Decision, Dept. No.
32803/1308/97 (Government Gazette Issue 815Β/1997) and was complemented by
Common Ministerial Decision No. Oik.F.9.2/ΟΙΚ.28425 (Government Gazette Issue
2604B/2008)
(Emblems of the Certification Body)
.....................................................
Certificate S/N ............
Publication Number of the Certification Body .....................................................
.................................................................... ............
Name & Address of the Certificate Holder: .....................................................
................................................................... .....................................................
....................…
Name & Address of the Manufacturer: .....................................................
.....................................................
........................
Class & Type of Lift: .....................................................
.................................................................... ............
Installation Location of a representative sample- .....................................................
model of the lift: ............
Attached documents: .....................................................
Date of submitting the inspection Application: ............
....................................................................
Inspection period: .....................................................
Inspection-testing Body: ............
Inspection results
Based on the inspection performed, it is determined that the above-mentioned lift installation
which represents the said type of lift fulfils the above-mentioned requirements.
Additional information/Remarks
The notified certification body must be notified on all amendments or new extensions-variations, as well as
any changes to the manufacturer’s safety components, standard materials and drawings of the type
inspected.
Published at...................................................(place) on ..../..../ (date)
For the Body
(Full name, Stamp and Signature)
...................................................................
ANNEX 16
INSTALLATION PERIODIC INSPECTION CERTIFICATE FOR AN ELECTRICAL-
HYDRAULIC LIFT
according to the requirements of the Common Ministerial Decision Dept. No.oik. F.9.2/28425
(Government Gazette Issue 2604B/2008)
(Emblems of the Certification Body)
Lift Details
Certificate S/N .....................................................
............
Publication Number of the Inspection / Certification .....................................................
Body ............
Building Permit Number .....................................................
............
Preliminary Installation/Operational .....................................................
License/Registration Number (delete accordingly) ............
Owner/ Building administrator .....................................................
............
Inspection Results
Based on the inspection performed, it is determined that the above-mentioned lift installation
fulfils the above-mentioned requirements of the Common Ministerial Decision No.oik.
F.9.2/28425 (Government Gazette Issue 2604B/2008)
Remarks
It should be noted that Regular Maintenance and Periodic Inspection are prerequisites for the
operation of the Lift. It should also be noted that any significant changes to the installation must be
announced and approved by the Body, following a re-inspection.
ANNEX 17
SCOPE OF ACCREDITATION
LIFTS 95/16/EC
Regulatory Scope
Lifts Directive 95/16/EC
-MD 32803/1308/97 (G.G 815/Β/97)
-ELOT ΕΝ 81-2+Α3:2010
-ELOT ΕΝ 81-1+Α3:2010
ANNEX 18
* they have been withdrawn and are applicable only as technical specifications
** they are not in force
ANNEX 19
(G.G 2604Β/2008)
supplement the
ELOT ΕΝ 81.1:1999 + technical
CMD:
Electrical & Α3:2010 specifications
F.9.2/oik.32803/1308
Hydraulic lifts ELOT ΕΝ 81.2:1999 + applicable at the
(G.G 815/Β/1997)
installed from Α3:2010 time the lift was
CMD oik.F9.2/28425
01/01/2012 until installed with the
(G.G 2604Β/2008)
today APPROVED RISK restrictions of
ANALYSIS article 15
«Transitional
provisions»