Professional Documents
Culture Documents
MF Beta 7370: Mount of Flex 7.60 M Ukraine Experience
MF Beta 7370: Mount of Flex 7.60 M Ukraine Experience
Hydraulic cylinder from Power Flow were used for this, part № D28284930
Hydraulic line was hand made and easily put through the header frame
Hydraulic connections
It is necessary to change
polarity on the reel speed
sensor wires
Problems not solved:
1. Reel speed is not correct
2. Reel starts to rotate after
header engagement only
after speed increase
Auto Level
Auto Level potentiometers are displayed on monitor, the header is calibrated OK.
AHHC works by double clicking on header down button on the joystick.
Problem not solved: input from potentiometers are changing, Auto Level doesn’t
work.
Combine at work (soybean)
Speed 4 km/h, humidity 18% (header drawback – slow knife speed, by increasing the forward speed the knife
tears the crop and gets stalled)
When in the middle of the day the humidity went down to some 14% they were harvesting at 7-8 km/h!!! The
combine didn’t feel any overload. The yield was some 2,5 t/ha
At night they stopped at the humidity of 20%!!! JD rotaries stopped right after sunset…
Average fuel consumption on monitor 8 l/ha, real level was 9,7 l/ha.