PHARMACEUTICAL MICROBIOLOGY
Small World but Big Opportunities.
Viable particles are not free floating they need a carrier to float from one area to another area.
Non-viable particles main source for movement of the viable particles.
Viable particles (Bacteria and fungi) 0.5um to 5.0 um size. So this range of particles are main source of product contamination.
Less than 0.5 um is critical of attachment of viable particle. Rece
Greater than 5.0 um is large size of particle can not move easily and settle down.
► 20
► 20
Non-Viable Particles Monitoring :
► 20
· Does not contain living organism. ▼ 20
· Non-feasible (particle)
▼
· Unable to survive independently.
· Manufacturing area, equipment, utilities and personnel are main source of particle contamination in aseptic area.
· Check the particles of 0.5 um to 5.0 size
· Electronic particle counter is used for particle counting.
· This instrument can’t differentiate between viable and non-viable particles.
· Any particle detected by the sensor of this instrument it will count this particles.
· For example particles are generated through the movement in aseptic area so movement of the personnel should be controlled and
rhythmic in aseptic area.Good manufacturing practices should be followed to control the particle contamination in aseptic area.
· As per EU GMP 1 m³ air should be sampled per location for particle monitoring. Particle contamination depends upon the activity in
aseptic area. If there is no activity in aseptic area then particle contamination would be low and if activity is in progress in aseptic area then
particle contamination would be increased. That's why guidelines has defined different limits for at rest and in operation conditions.
· In pharmaceuticals, online and continuous monitoring of particles are also performed in which particle counter gives results in form of print
out during production hours. This is very important tool to have great control over the aseptic area during production hours.
· During monitoring any deviation from the specified limits could results in investigation. Below is the chart showing maximum number of
permitted particles in different classes of area as per EU GMP guideline.
· So, to control classified area we need to control both viable and non-viable particles.
pharmaceuticalmicrobiologi.blogspot.com/2016/12/difference-between-viable-particle-and.html 1/3
11/18/2020 PHARMACEUTICAL MICROBIOLOGY: Difference between Viable particle and Non-Viable particle
A
Maximum permitted number of particles per m3 equal to or greater than the tabulated size
At Rest In operation
Grade
0.5 µm 5.0 µm 0.5 µm 5.0 µm
A 3520 20 3520 20
B 3520 29 352000 2900
C 352000 2900 3520000 29000
D 3520000 29000 Not defined Not defined
Tota
Difference between Viable particle and Non-Viable particle 3
Before going manufacturing of pharmaceutical product verify the environment by monitoring method. Pharmaceutical Environmental monit...
6
pharmaceuticalmicrobiologi.blogspot.com/2016/12/difference-between-viable-particle-and.html 2/3
11/18/2020 PHARMACEUTICAL MICROBIOLOGY: Difference between Viable particle and Non-Viable particle
pharmaceuticalmicrobiologi.blogspot.com/2016/12/difference-between-viable-particle-and.html 3/3