New Network Element Software Installation

Overview:
To provide a complete step by step process to install Release 5.1 system
software on a new 1830PSS-32/16 network element

References:
Release 5.1 Installation Engineering Handbook IEH 600
Release 5.1 Customer Release Notes
Release 5.1 Installation and System Turn-up Guide

Chapter 1:
Internet Explorer configuration
Java configuration
FTP root path and software folder configuration
3Com 3CDaemon configuration

2
New Network Element Software Installation

Chapter 2:
Integration Prerequisites prior to software installation
Network Element turn-up steps prior to software installation
Network Element connection for WebUI access
Network Element connection for CLI access

Chapter 3:
Starting the 3Com 3CDaemon FTP server
Configuring the FTP server settings on the network element
Performing the Software Audit
Performing the Software Download
Performing the Software Activation
Clearing the Database
Committing the Software

3
New Network Element Software Installation

Chapter 4:
Verifying the software installation
Sequence of the remaining turn-up steps
Redundant Equipment Controller (EC) card

4
Do not delete this graphic elements in here:

Configurations for:
Internet Explorer, Java,
FTP root / R5.1 Software,
and 3Com 3CDaemon
Chapter 1 Internet Explorer
Internet Explorer Details
Supported Internet Explorer Versions: 6, 7, and 8
Turn Off Internet Explorer Pop-up Blocker
Tools>Internet Options>Privacy
Turn Off any other Tool Bar Pop-up Blockers
Turn Off any active LAN proxy
Turn On LAN Automatically Detect Settings
Tools>Internet Options>Connections>LAN Settings

Internet Explorer 8 Examples

Reference:
IEH 600, Section 200, Pre-Installation Tasks

6
Chapter 1 Java
Java Details
Supported Java Version: 6, any Update Level
Control Panel>Java>About
Update 10 and higher must have the “Enable Next-
Generation Java Plug-in” Unchecked
Default Java for Browsers must have Internet Explorer
checked Control Panel>Java>Advanced

Java 6 Update 26 Examples

Reference:
IEH 600, Section 200, Pre-Installation Tasks
CRN R5.1, Chapter 2, WebUI Issue # 18168

7
Chapter 1 FTP root path and software folder
FTP root path
Create a root folder directly on the hard drive (FTProot) for the NE software loads
Copy the 1830PSS-32 R5.1 NE software folder (1830PSS32-5.1-0) into the new FTProot folder

Examples shown
represent the file
structure for R5.0

Reference:
IEH 600, Section 200, Software Installation
8
Chapter 1 3Com 3CDaemon FTP Server
FTP Server
3Com 3CDaemon always starts up with displaying the TFTP server
Click on the FTP Server button in the lower left area to display the FTP server
Click on Configure FTP Server to enter the profile name, password, permissions, and User Directory

Example

Profile Name = 1830


Password = tester
User Directory = Browse to
C:\FTProot

Privileges = All Are Checked


Scroll down to check them all
Save Profile

9
Reference:
IEH 600, Section 200, Software Installation
Do not delete this graphic elements in here:

Integration Prerequisites
NE Turn-up Steps
NE Connection for WebUI
NE Connection for CLI
Chapter 2 Prerequisites prior to software installation

Open the IEH 600 Handbook and go to Section 200:


Integration Prerequisites, NE Turn Up, and NE Connection

• Verify that all of the items on the Installation Checklist are


complete. (Also refer to Appendix A and C for more details.)

• Verify that all of the items on the Network Element Checklist are
complete.

• Verify that all of the steps in the NE Turn Up pages are complete.

• Review the NE Connection pages for establishing the laptop


connectivity to the NE for WebUI and CLI

Reference:
IEH 600, Section 200, Integration Prerequisites, NE Turn Up, and NE Connection

11
Chapter 2 Prerequisites prior to software installation

NE Connection

Reference:
IEH 600, Section 200, NE Connection

12
Chapter 2 Prerequisites prior to software installation

NE Connection
Verify that you can ping the EC card /CIT port (172.16.0.1)

Reference:
IEH 600, Section 200, NE Connection

13
Chapter 2 Prerequisites prior to software installation
NE Connection: WebUI
Verify that you can login to the NE from WebUI
Enter the CIT IP Address 172.16.0.1 in the Address Bar of Internet Explorer
Enter the User and Password both as admin

Reference:
IEH 600, Section 200, NE Connection
14
Chapter 2 Prerequisites prior to software installation
NE Connection: CLI
Verify that you can login to the NE from CLI

telnet to the CIT IP Address 172.16.0.1

First Login/Password
Are both cli
Password will not echo

Second Login/Password
Are both admin
Password will not echo

Acknowledge the CLI


Warning Notice

Reference:
IEH 600, Section 200, NE Connection
15
Chapter 2 Prerequisites prior to software installation

2 Scenarios of a First Time WebUI NE Login


1. EC card with 1830PSS-0.32-1 Factory Load and No Existing Database
2. EC card with 1830PSS-0.32-1 Factory Load and Existing Database

Scenario 1 0.32-1 Enter the Proceed to


Database NE Name Software
Message and Submit Upgrade
Login
via
WebUI
System Proceed to
Properties Software
Scenario 2 Screen Upgrade

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
16
Chapter 2 Prerequisites prior to software installation
EC card with 1830PSS-0.32-1 Factory Load and No Existing Database

1. Enter NE Name and Submit


2. EC card reboots
3. Proceed to Software Upgrade

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
17
Chapter 2 Prerequisites prior to software installation
EC card with 1830PSS-0.32-1 Factory Load and Existing Database

Existing NE Name
EC card Software Version
Proceed to Software Upgrade

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
18
Do not delete this graphic elements in here:
Starting the 3Com 3CDaemon FTP server
Configure the FTP server settings on the NE
Performing the Software Audit
Performing the Software Download
Performing the Software Activation
Clearing the Database
Committing the Software
Chapter 3 Starting the 3Com 3CDaemon FTP Server

1. Open 3CDaemon – It always opens in TFTP Server Mode


2. Click on the FTP Server button
3. Verify that the Server is listening for FTP requests on 172.16.0.2

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
20
Chapter 3 Configure the FTP Server Settings on the NE
Important – The PSS-16 Downloads Must Be Performed using CLI commands
listed in the Customer Release Notes.
The PSS-32 Downloads can be performed by either WebUI or CLI

For PSS-32 Downloads Using WebUI


1. From WebUI Administration Drop-Down
2. Click on Software, then FTP Server
3. Enter the FTP Server Information
Server IP, Root Directory /, User ID,
Password, and Confirm Password
4. Click the Apply button
5. Click the Close button

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
21
Chapter 3 Performing the Software Audit

Example shown
represents R5.0

1. From WebUI Administration Drop-Down


2. Click on Software, then Upgrade
3. From the Action Drop-Down, Click on Audit
4. Enter the Software Folder Name in the Release Directory field
5. Click on the Apply button
Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
22
Chapter 3 Performing the Software Audit

Example shown
represents R5.0

1. Verify the Audit completed successfully

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
23
Chapter 3 Performing the Software Download

Example shown
represents R5.0

1. From the Action Drop-Down, Click on Download


2. Click on the Apply button

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
24
Chapter 3 Performing the Software Download

Example shown
represents R5.0

1. Verify the Download is in progress


2. Click on the minimized 3CDaemon window

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
25
Chapter 3 Performing the Software Download

1. Verify the FTP transfer is in progress


2. Click on the minimized WebUI window

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
26
Chapter 3 Performing the Software Download

Example shown
represents R5.0

1. Verify that the Download is in progress


2. Click on the Refresh button to verify the status
3. Verify that the Download completes successfully
The Download process takes approximately 10 minutes to complete

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
27
Chapter 3 Performing the Software Activation

Example shown 1. From the Action Drop-Down, Click on Activate


represents R5.0
2. Click on the Apply button
3. Click OK on the reboot message
4. The NE will reboot on the new software load
5. The NE will logout the users in the WebUI
The Activation process takes approximately 30 minutes to complete
Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
28
Chapter 3 Performing the Software Activation

1. Following the Activation


2. Verify that you can ping the CIT port
3. Start a telnet session to the CIT port
4. Connect through CLI

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
29
Chapter 3 Clearing the Database

1. After logging in through CLI


2. Enter config database clear
3. Enter yes to confirm
4. The database will be reset
5. The NE will reboot
6. The CLI session will be logged out

** For Network Elements That Had Existing Databases: **


In Step 2. Use the command config database clear ipclear
The database, NE Name, & IP Addresses will be reset
The NE Name will be changed again at the next login

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
30
Chapter 3 SDH Mode

SDH MODE (The factory defaults set the NE as a SONET ADM)


** SDH MODE IS ONLY REQUIRED FOR NE’s OPERATING AS SDH ADM’s **
1. After logging in through CLI
2. Enter show version
3. The cli output will read as Software Version: 1830PSS32-5.1-0
4. The Software Version will be used as a password for the sdh mode command
5. Enter config admin mode sdh 1830PSS32-5.1-0
6. Enter yes to confirm
7. The database will be reset with SDH defaults
8. The NE will reboot
9. The CLI session will be logged out
10. Proceed to Committing the Software

Reference:
IEH 600, Section 200, Software Installation

31
Chapter 3 Committing the Software

1. Following the database reset


2. Verify that you can ping the CIT port
3. Start a WebUI session to the NE

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
32
Chapter 3 Committing the Software

Example shown
represents R5.0

1. From WebUI Administration Drop-Down


2. Click on Software, then Upgrade
3. From the Action Drop-Down, Click on Commit
4. Click on the Apply button

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
33
Chapter 3 Committing the Software

Example shown
represents R5.0

1. Click on the Refresh button


2. Verify that the Commit has completed successfully

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
34
Do not delete this graphic elements in here:

Verifying the software installation


Sequence of the remaining turn-up steps
Redundant Equipment Controller (EC) card
Chapter 4 Verifying the Software Installation

Example shown
represents R5.0

1. Click on the Refresh button


2. Verify that the Commit has completed successfully
3. Verify that the Active, Working, and Committed loads are all R5.1.0
4. Verify that there is an upgrade path available

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
36
Chapter 4 Verifying the Software Installation

Example shown
represents R5.0

1. On the System Properties Screen


2. Verify that the NE Type is a v5.1 SONET or SDH ADM
3. Verify that the Software Release is 1830PSS32-5.1-0

Reference:
IEH 600, Section 200, Software Installation
CRN R5.1, Chapter 3, Software Installation
37
Chapter 4 Sequence of the Remaining Turn-up Steps

1. Resume with the IEH 600, Section 200, Network Element Setup to complete the
remaining NE turn-up tasks.

Reference:
IEH 600, Section 200, Network Element Setup
38
Chapter 4 Redundant Equipment Controller (EC) Card

1. Fully seat the redundant EC card in Slot 18 (PSS-32) or Slot 12 (PSS-16)


2. The EC will boot up and declare software version mismatch
3. The EC will also declare an unsynchronized database
4. The automatic software upgrade process will upgrade the redundant EC
5. The automatic database synchronization will update the redundant EC
6. The complete automatic process to synchronize the EC cards can take up to
45 minutes to complete

Reference:
IEH 600, Section 200, Network Element Setup
39