X-Tract Electrical Submersible Pump Cable


®

2R205 Light-to-Moderate-Duty, Round Power Supply (PS) Cable


5 kV, Rated -40°C to +96°C/-40°F to +205°F

EPDM Overall Solid Bare Annealed


Cable Jacket Copper (SBC)

Armor - Standard: Galvanized EPDM Insulation Adhesive Layer


Steel (G) 100% Perimeter

Round Type 2 cables are lower-temperature-rated for operating temperatures of -40 to +205 degrees F/
-40 to +96 degrees C. The Type 2 design provides excellent performance and life expectancy in
less gassy wells and where decompression resistance is not required. Type 2 cables are designed for
light-to-moderate-duty use in low-pressure, cooler and less gassy wells with less corrosive conditions.

Product Construction: Armor (cont’d): Industry References:


Conductor: • Armor Options: • IEEE 1018
• Solid bare annealed copper per — Stainless steel alloy for increased • API RP 11S5
ASTM B3 performance in highly corrosive well • API RP 11S6
• Option: 7-strand compact blocked environments • ASTM A459
copper per ASTM B496 — Monel alloy for superior • ASTM B3
performance in highly corrosive well • ASTM D412
Insulation: environments
• Adhesive layer Standard Packaging:
• EPDM insulation Marker Tape: • DIN standard heavy-duty steel reels
— Cross-linked, high dielectric GENERAL CABLE® USA X-TRACT® — Corrosion-resistant design with
strength, high oil resistance, TYPE 2 5 KV -40C to +96C/-40F to 100% protective over-coating
low swell, chemically inert, +205F 3/C XAWG ARMOR TYPE • The cable ends will be sealed with
mechanically stable MONTH/YEAR OF MFG SEQUENTIAL weather-resistant caps or suitable
Overall Cable Jacket: FOOTAGE MARK tape
• EPDM insulation jacket Applications: • Lagging: 2-by-4-inch treated wood
— Cross-linked, high dielectric with 3 encircling corrosion-resistant
• Power Supply (PS) light-to-moderate- bands
strength, high oil resistance,
duty service: • Option: multiple non-standard lengths
low swell, chemically inert,
— Low-to-moderate gas and vapor per reel
mechanically stable
concentrations
Armor: — Low-to-moderate corrosion
• Galvanized steel 100% perimeter — Low-to-moderate temperature
— Heavy zinc alloy plating for extra
corrosion resistance – interlocked
profile for enhanced mechanical
stability

Phone: 888-593-3355
www.generalcable.com
9
SPEC 120
September, 2011

X-Tract Electrical Submersible Pump Cable


®

2R205 Light-to-Moderate-Duty, Round Power Supply (PS) Cable


5 kV, Rated -40°C to +96°C/-40°F to +205°F

NOMINAL NOMINAL
COND. SIZE CONDUCTOR INSULATION NOMINAL JACKET
(Solid) DIAMETER DIAMETER DIAMETER NOMINAL CABLE O.D. NOMINAL WEIGHT
CATALOG
NUMBER kV AWG mm² INCHES mm INCHES mm INCHES mm ARMOR TYPE INCHES mm lbs/1000 ft kg/km

Galvanized
120.6312055G 5 6 13.30 0.162 4.11 0.342 8.69 0.857 21.77
Steel (G)
1.10 27.86 959 1427

Stainless
120.6312055SS 5 6 13.30 0.162 4.11 0.342 8.69 0.857 21.77
Steel (SS)
1.02 25.83 815 1213

120.6312055MN 5 6 13.30 0.162 4.11 0.342 8.69 0.857 21.77 Monel (MN) 1.02 25.83 840 1249

Galvanized
120.5312055G 5 5 16.78 0.182 4.62 0.362 9.19 0.900 22.86
Steel (G)
1.14 28.95 1078 1604

Stainless
120.5312055SS 5 5 16.78 0.182 4.62 0.362 9.19 0.900 22.86
Steel (SS)
1.06 26.92 926 1378

120.5312055MN 5 5 16.78 0.182 4.62 0.362 9.19 0.900 22.86 Monel (MN) 1.06 26.92 952 1417

Galvanized
120.4312055G 5 4 21.15 0.204 5.19 0.384 9.76 0.948 24.08
Steel (G)
1.19 30.18 1204 1792

Stainless
120.4312055SS 5 4 21.15 0.204 5.19 0.384 9.76 0.948 24.08
Steel (SS)
1.11 28.15 1045 1555

120.4312055MN 5 4 21.15 0.204 5.19 0.384 9.76 0.948 24.08 Monel (MN) 1.11 28.15 1072 1595

Galvanized
120.2312055G 5 2 33.63 0.258 6.54 0.438 11.12 1.063 27.00
Steel (G)
1.30 33.10 1543 2295

Stainless
120.2312055SS 5 2 33.63 0.258 6.54 0.438 11.12 1.063 27.00
Steel (SS)
1.22 31.06 1364 2029

120.2312055MN 5 2 33.63 0.258 6.54 0.438 11.12 1.063 27.00 Monel (MN) 1.22 31.06 1394 2075

Galvanized
120.1312055G 5 1 42.34 0.289 7.35 0.469 11.92 1.131 28.74
Steel (G)
1.37 34.83 1769 2632

Stainless
120.1312055SS 5 1 42.34 0.289 7.35 0.469 11.92 1.131 28.74
Steel (SS)
1.29 32.80 1578 2348

120.1312055MN 5 1 42.34 0.289 7.35 0.469 11.92 1.131 28.74 Monel (MN) 1.29 32.80 1611 2397

Voltage drop based on 60Hz and 100% power factor

Phone: 888-593-3355
www.generalcable.com
10