1. VEHICLE PARTICULARS :
Vehicle Registration No. :
Particulars of wiring :
Whether properly fixed and protected Yes / No
Earthing points (Construction & Location) : Discharge valves / Base plates
Electrical wiring particulars : OK / Not OK
Clearance between end of vessel and end :
of rear bumper (Min. 7.5 cms.)
2] REAR OVERHANG
7] CIRCUMFERENCE OF VESSEL
9] DISTANCE BETWEEN [ WL – WL ] / [ TL – TL ] WL – WL = TL - TL =
10] EXACT POSITION OF ROTOGAUGE i] SIDE OF THE VESSEL ii ] ON THE MANHOLE iii] _______________________
15] LOCATION OF EXHAUST PIPE [ FRONT/ DRIVER’S SIDE OF PRIME MOVER] / [ NEAR THE FRONT WHEEL /
NEAR THE REAR WHEEL OF PRIME MOVER ]
16] WHETHER THERMAL SHIELD PROVIDED BY CHASSIS i] satisfactory II] unsatisfactory
MANUFACTURER FOR ENTIRE EXHAUST PIPING SYSTEM
17] HEIGHT BARRIER [ BOX TYPE OR NOT ]
19] EARTHING STRIPS [ CONNECTED OR NOT ] i] between the flanges ii] between the base plates iii] any other places
20] WHETHER ACME ADAPTOR WITH CAP PROVIDED OR NOT [FOR EACH
LIQUID & VAPOUR INLET / OUTLET PIPE LINE ]
21] WHETHER AT LEAST 6 METERS LONG EARTHING CABLE PLACED
BEHIND THE DRIVER’S CABIN OR NOT
22] WHETHER “PRIME MOVER TO VESSEL” EARTHING CABLE PROVIDED
OR NOT
23] WHETHER OPEN & CLOSE DIRECTION FOR DISCHARGE VALVE
PROPERLY ARROWED & PAINED OR NOT]
24] WHETHER BRAKE LIGHTS & PARKING LIGHTS ARE IN WORKING
CONDITION
25] EXACT POSITION AND ORDER OF FIXED LEVEL GAUGE AND SRV’S. P.M. FLG/SRV FLG/SRV FLG/SRV FLG/SRV R.G.
26] EXACT POSITION AND ORDER OF IEFCV [ LIQUID LINE & VAPOUR P.M. LIQ. / VAP. LIQ. / VAP. LIQ. / VAP. R.G.
LINE]
2) Rule 43 to be issued due to: (a) New Vessel, (b) Change of Ownership, (c) Change of Prime Mover [ Horse], (d) Change
of Trailer Chassis [ Running Gear ], (e) Change of Product, (f) Change of Registration No., (g) Change of Jurisdiction, (h)
Accidental Vehicle (i) for Vessel Modification (j) Change of Chassis for fixed Chassis vehicle (i) for any other reason [ Please
Spacify]
_________________________________________________________________________________________________
………………………………… ……………………………………….
Signature for on behalf of Signature of customer
SIMO Research Engineers Pvt. Ltd. with company seal
Sheet 4 of 6
UTM REPORT
Date of Test:
SHELL
END
SHELL
END
SHELL
END
DISHED
END-1
DISHED
END-1
DISHED
END-2
DISHED
END-2
Please take good snap of following details listed below: 13] pics of Spark Arrestor [ if applicable]
14] pics of Safety kit
1] pics of front view of Prime mover 15] pics of top Weld Cap
2] pics of rear view of Prime Mover 16] pics of IEFCV’s
3] pics of Exhaust pipe 17] pics of Fuel ( Oil ) tank
4] pics of Prime Mover from Driver’s side 18] pics of Manhole
5] pics of Engine no. 19] pics of King-pin
6] pics of Chassis no. 20] pics of Fire Extinguisher
7] pics of Running Gear 21] pics of Height Barrier
8] pics of rear side of the vessel 22] pics of Lifting Lug
9] pics of vessel name plates. [ both ] 23] pics of Ball Valves
10] pics of Pressure Gauge 24] pics of Drainage pipe
11] pics of Temparature Gauge 25] pics of Jacks & Props, Ladder,Fire Screen etc.
12] pics of Rotogauge
Sheet 5 of 6
REMARKS:
Sheet 6 of 6
OWNER ATTENDER
COMPANY MOB. NO.
MOB. NO. E-MAIL ID
E-MAIL ID
SRV NOS.
MAKE
MANUFACTURING DATE
SET PRESSURE
DISCHARGE FLOW RATE
IEFCV NOS.
LOCATION LIQ. LINE / VAP. LINE LIQ. LINE / VAP. LINE LIQ. LINE / VAP. LINE
SIZE 2” NPT / 1.5” NPT 2” NPT / 1.5” NPT 2” NPT / 1.5” NPT
MAKE
MANUFACTURING DATE
DIFFERENTIAL PRESSURE
CLOSING FLOW RATE
DISCHARGE VALVE
MAKE
SIZE 2” NPT / 1.5” NPT 2” NPT / 1.5” NPT 2” NPT / 1.5” NPT
FIXED LEVEL GAUGE MAKE: SL.NO.: MFG. DT.:
ROTAGAUGE MAKE: SL.NO.: MFG. DT.:
PRESSURE GAUGE MAKE: RANGE: SIZE:
P.G. [3/4” NPT EFCV] MAKE: SL.NO.: MFG. DT.:
TEMPARATURE GAUGE MAKE: RANGE: SIZE:
SPARK ARRESTOR MAKE: SL.NO.: WHETHER INBUILT
/PROVIDED
SAFETY KIT MAKE: SL.NO.: