HYDROSTATIC TEST REPORT

CLIENT : NAGARJUNA OIL CORPORATION LTD. DATE :


P. O. No. : LOI NO. - SAP/ 0012 / 2010 DT. 12.02.2010 EQPT. No. : E – 103 C

W. O. No. : 09-189 INSPECTION AGENCY : TUV NORD


DRG. No. : SDB/E/101591 REV.0

DETAILS OF INSPECTION

1) Test Description : SHELL SIDE (COMPLETE EQUIPMENTS )

2) Test Pressure (Required) : 20.75 Kg/cm2 G Actual Test Pressure : 21.0 Kg/cm2 G

3) Test Position : HORIZONTAL

4) Test Media : WATER

5) Chloride Content : 24 ppm

6) Test Pressure Holding Duration : 1 HOUR

7) Test Temperature : 29  C

8) Pressure Gage Details : AS BELOW

Range Verification of Gage


Identification No. Manufacturer Calibration Date
Kg/cm2g Calibration
PG-01 WAAREE O TO 70 11.08.2015 ------
----- ----- ----- ----- ------

Calibration Due Date: - 10.02.2016


9) Observation
Drop in Pressure : NIL
Leakage : NIL
10) Result : No Leakage OR any Pressure drop observed

Inspection by : Witnessed by :

Signature : Signature :

Name : Name :

Date : Date :