HYDROSTATIC TEST REPORT

PROJECT NO : TOE-13068E TEST DATE : 14-Feb-14


ASME NO : TOE-U-1037-14 REPORT NO : HTR-13068-03

INSTRUMENTATION AND GAUGE CALIBRATION RECORD


Certificate Number QC Serial No. Manufacturer Range Date Of Remarks
Calibration
PS 140020 TOE-EQT-PG58 WIKA 0~2000 psi 08/01/2014 PR.GAUGE
PS 140021 TOE-EQT-PG59 WIKA 0~2000 psi 08/01/2014 PR.GAUGE
PS 134037 TOE-EQT-PR-003 BARTON 0~2000 psi 11/09/2013 PR.RECORDER

To Whom It May Concern :


This Is To Certify That Hydrostatic Test Was Conducted on the Equipment :

ITEM DESCRIPTION : PRIMARY OIL SEPARATOR

DRAWING NO.: 91013010-M-DW-101-16 REV-A

TAG.NO. V-7511C

DESIGN PRESSURE : 449.5 psig

M.A.W.P. : 487.98 psig

TEST PRESSURE : 584.35 psig

TEST TEMPERATURE : Average 29~32 Deg C

HAS BEEN TESTED TO : 600 psig

AND HELD FOR : 1 HR

Without Any Signs Of Leakage And/Or Permanent Deformation.


THIS IS THE LOOPED HYDROTEST WITH U NO : TOE-U-1035-14, TOE-U1036-14&TOE-U-1037-14
Technics Offshore AUTHORISED INSPECTOR

WITNESSED BY : TILAK (QC INSPECTOR) WITNESSED BY :

SIGNATURE : SIGNATURE :
DATE : DATE :

B.V. INSPECTOR CLIENT REPRESENTATIVE

WITNESSED BY :

SIGNATURE : SIGNATURE :
DATE : DATE :
HYDROSTATIC TEST REPORT
PROJECT NO : TOE-13068E TEST DATE : 14-Feb-14
ASME NO : TOE-U-1036-14 REPORT NO : HTR-13068-02

INSTRUMENTATION AND GAUGE CALIBRATION RECORD


Certificate Number QC Serial No. Manufacturer Range Date Of Remarks
Calibration
PS 140020 TOE-EQT-PG58 WIKA 0~2000 psi 08/01/2014 PR.GAUGE
PS 140021 TOE-EQT-PG59 WIKA 0~2000 psi 08/01/2014 PR.GAUGE
PS 134037 TOE-EQT-PR-003 BARTON 0~2000 psi 11/09/2013 PR.RECORDER

To Whom It May Concern :


This Is To Certify That Hydrostatic Test Was Conducted on the Equipment :

ITEM DESCRIPTION : PRIMARY OIL SEPARATOR

DRAWING NO.: 91013010-M-DW-101-16 REV-A

TAG.NO. V-7511B

DESIGN PRESSURE : 449.5 psig

M.A.W.P. : 487.98 psig

TEST PRESSURE : 584.35 psig

TEST TEMPERATURE : Average 29~32 Deg C

HAS BEEN TESTED TO : 600 psig

AND HELD FOR : 1 HR

Without Any Signs Of Leakage And/Or Permanent Deformation.


THIS IS THE LOOPED HYDROTEST WITH U NO : TOE-U-1035-14, TOE-U1036-14&TOE-U-1037-14
Technics Offshore AUTHORISED INSPECTOR

WITNESSED BY : TILAK (QC INSPECTOR) WITNESSED BY :

SIGNATURE : SIGNATURE :
DATE : DATE :

B.V. INSPECTOR CLIENT REPRESENTATIVE

WITNESSED BY :

SIGNATURE : SIGNATURE :
DATE : DATE :
HYDROSTATIC TEST REPORT
PROJECT NO : TOE-13068E TEST DATE : 14-Feb-14
ASME NO : TOE-U-1035-14 REPORT NO : HTR-13068-01

INSTRUMENTATION AND GAUGE CALIBRATION RECORD


Certificate Number QC Serial No. Manufacturer Range Date Of Remarks
Calibration
PS 140020 TOE-EQT-PG58 WIKA 0~2000 psi 08/01/2014 PR.GAUGE
PS 140021 TOE-EQT-PG59 WIKA 0~2000 psi 08/01/2014 PR.GAUGE
PS 134037 TOE-EQT-PR-003 BARTON 0~2000 psi 11/09/2013 PR.RECORDER

To Whom It May Concern :


This Is To Certify That Hydrostatic Test Was Conducted on the Equipment :

ITEM DESCRIPTION : PRIMARY OIL SEPARATOR

DRAWING NO.: 91013010-M-DW-101-16 REV-A

TAG.NO. V-7511A

DESIGN PRESSURE : 449.5 psig

M.A.W.P. : 487.98 psig

TEST PRESSURE : 584.35 psig

TEST TEMPERATURE : Average 29~32 Deg C

HAS BEEN TESTED TO : 600 psig

AND HELD FOR : 1 HR

Without Any Signs Of Leakage And/Or Permanent Deformation.


THIS IS THE LOOPED HYDROTEST WITH U NO : TOE-U-1035-14, TOE-U1036-14&TOE-U-1037-14
Technics Offshore AUTHORISED INSPECTOR

WITNESSED BY : TILAK (QC INSPECTOR) WITNESSED BY :

SIGNATURE : SIGNATURE :
DATE : DATE :

B.V. INSPECTOR CLIENT REPRESENTATIVE

WITNESSED BY :

SIGNATURE : SIGNATURE :
DATE : DATE :

You might also like