Professional Documents
Culture Documents
Calculo Ultrasonico Lavalin 24in
Calculo Ultrasonico Lavalin 24in
Pipe Material: Steel Liquid Selection: Estimated Vs: Kinematic Visc. (cS): API:
Outside Dia.: 24.0 Water (50C) 1543.0 0.55 11.4293
Wall Thickness: 0.375 Operating Conditions: Minimum Maximum
Liner Material: None Flow Rate: 100.0 475.0 Kilo 42.0 GAL BBL/DAY
Liner Thickness: Temperature: 80.0 148.0 deg F
Desired Accuracy >2.0% Upstream Conditions: Straight Run
Type: High Precision Size: D1H Siemens P/N: Mount: Reflect Spacing Offset: Nom
High Precision * D1H * 7ME39505GP20 Reflect * Nom *
Application Calcs.
Min Flow Max Flow Units
Cycles dT: 0.13 0.62 cycles
Reynolds #: 721160 3425510
Flow Velocity: 0.67 3.19 meters/sec
Spacing: {Nom 48} LTN: 29.889 inches
Estimated Repeatability: 126.7705 42.0 GAL BBL/DAY
Vs Range Limits: 1376 to 1710 meters/sec
TN: 1005.24 usec
TL: 907.26 usec
1 cycle Vs: 5.5 meters/sec
VFmax: 760.623 Kilo 42.0 GAL BBL/DAY
Repeatability Graph
Repeatability vs. Flow Rate
Start RN Transition = 235.7 42.0 GAL BBL/DAY End = 693.3 42.0 GAL BBL/DAY
0.27%
0.18%
%Repeatability
0.09%
0%
-0.09%
-0.18%
-0.27%
-100 0 100 200 300 400 500
Flow Rate(Kilo 42.0 GAL BBL/DAY)
Page 1 of 1