You are on page 1of 1

High-Temperature Memory Production Logging (MPLT)

Fluid
Density
(Optional)
Small 1.44” Diameter ADVANTAGES
BATTERY

Pressure control is simplified in


High Temperature Production Logging slickline high-pressure (gas) well
At Its Best operations.
MEMORY

Fluid Short tool strings permit use in


Identification
Module Scientific Production Services’s High height-restricted areas (offshore).
Temperature Memory Production Logging Tool Less weight is required with
slickline resulting in less lubricator,
ELECTRONICS

(MPLT) 1.44” (36.5mm) diameter 575°F


(300°C) sets the memory production and easier rig up, and lower costs.
geothermal logging performance standard. The need for high temperature
This high-temperature modular system logging cables is eliminated, thus
packages the following optimized sensors: eliminating those costs.
Capacitance Horizontal wells are easily logged
Casing Collar Locator (CCL) using any standard coiled tubing
Heatshield Gamma Ray unit since no expensive wireline
& Pressure Pressure is needed.
BATTERY

Housing
Temperature Has proven, successful reliability
Spinner in wells worldwide.
Capacitance Software provides onsite data
Nuclear Fluid Density presenation and interpretation.
MEMORY

Gathers data easily and cost-


ffectively.
Compact Size Equals
CCL
Increased Performance
Gamma
ELECTRONICS

18’ Ray The compact MPLT is 1.44 inches in diameter Technical Specifications
by 18 feet long. Its reduced cross-section has Temperature O o

less tool weight and less affect on flowing well 575 F (300 C)
PTS Rating: + o o

characteristics (less choking effect) than larger Accuracy: - 1.8 F (1 C)


o o

diameter systems. MPLT’s memory logging Resolution: 0.018 f (.03 C)


features have distinct advantages over
conventional wireline logging. Pressure
Accuracy: +- 3.0 psi (20.7 kPa)
Thermal Resolution: 0.01 psi (0.07 kPa)
Isolator
Multi-Faceted Applications Memory: Non-volatile, 2Mb/8Mb

Has full production logging capabilities Spinner: Minimum 0.1 rps


Pressure Establishes flow profiles with direction
Temperature Establishes fluid types and mixes Scint - Na I (T1)
Gamma Ray:
Detects leaks 5/8” diameter x 3” long
Identifies production problems Casing Collar 50 samples per second
Can be used with any downhole Locator (CCL):
Full Bore
or conveyance system Nuclear Fluid Density
In-Line Is highly reliable in slickline and coiled Accuracy: 0.003 g/cc
tubing applications Resolution: +- 0.001 g/cc
Spinner
Measures downhole steam quality with
sophisticated pressure, temperature, Capacitance
spinner, and nuclear fluid density sensors Gas: 59 kHz
Measures downhole mass flow rate with Oil: 55 kHz
Water: 29 kHz
high performance spinner and nuclear fluid
density sensors 1.44 inches
Outer Diameter: (36.5 millimeters)
Length: 18 feet (5.48 meters)

Weight: 97 pounds
(44 kilograms)

Scientific Production Services SPS-Rev 05 8-8