RAIN WATER HARVESTING DYPSOA - Prof. Sanjita M. & Prof. Aprajita K.
LUMEN METHOD for Artificial Lighting DYPSOA - Prof. Sanjita M. & Prof. Aprajita K. LUMEN METHOD for Artificial Lighting DYPSOA - Prof. Sanjita M. & Prof. Aprajita K. For fluorescent light MF= 0.8 & U = 0.62
LUMEN METHOD for Artificial Lighting DYPSOA - Prof. Sanjita M. & Prof. Aprajita K. Assignment :
A drawing Studio in an architecture college needs to be provided with
lighting installation. The studio is 30Mx20M with required illumination of 300 Lux. Find no. of Lamps if each lamp has lumen output 6000 lumens. Given : Maintenance Factor MF= 0.6, Utilisation Factor U/Cu = 0.75
LUMEN METHOD for Artificial Lighting DYPSOA - Prof. Sanjita M. & Prof. Aprajita K.