Professional Documents
Culture Documents
BLEED
VALVES
NGP
1
NGP
2
GENERATOR
NGP
3
AUTO
WT
SYNC T1
T5
PCD
BYPASS
VALVE
GAS LIQUID
FUEL FUEL
ACV FCV STOP
FUEL
FUEL VALVE
PUMP
4-20 mA 4-20 mA
FUEL PRESSURE INPUT LCV VALVE OUTPUT
4-20 mA
ACCEL CONTROL VALVE OUTPUT THERMOCOUPLE INPUTS mV
4-20 mA TC01-TC18
FUEL VALVE OUTPUT
4-20 mA
PCD INPUT
4-20 mA
AMBIENT TEMPERATURE INPUT
FREQUENCY
GP SPEED INPUT 3
4-20 mA
WATTS INPUT
RAISE
SYNCHRONIZING INPUT
LOWER
FREQUENCY
GP SPEED INPUT 2
FREQUENCY NOTE: GP SPEED INPUTS 2oo3 VOTE
GP SPEED INPUT 1
4-20 mA
BLEED VALVES OUTPUT
OPTIONAL
MMI
APPLICATION CONTROL PACKAGE 9500-SS-GEN
COMM PORT
Simplified schematic showing a Petrotech Solar Saturn® gas turbine generator drive application control package
integrated into an advanced PLC-based control system.
PRODUCT BULLETIN 00006 - SOLAR SATURN® GAS TURBINE GENERATOR DRIVE APPLICATION CONTROL PACKAGE- Page 2
• Output failure shutdowns • Complete custom engineered control panel, factory tested and ready
to install
• Control mode
• Fuel control valve system upgrade
Controllers/special features: • Acceleration control valve system upgrade
• Start-up controller for fuel valve
• Inlet guide vanes actuator system upgrade or retrofit
• GP controller for fuel valve
• Bleed valve actuator system upgrade
• NPT controller for fuel valve
• Thermocouple upgrade
• T5 controller for fuel valve
• Synchronizing and regulation equipment
• Bleed valve controller
• Vibration system upgrade
• Acceleration control
• Installation and commissioning
• Combustion monitoring system
• Training
• Isochronous loadsharing
• Bumpless transfer between droop and isochronous modes
Ramps:
• Firing (lean lightoff) ramp
• Start-up ramp
• Loading ramp
• Cooldown ramp
Does not include:
• PLC hardware
• Gas turbine sequencing and protection discrete logic
• Generator sequencing and protection discrete logic
• Synchronizing and regulation equipment
• End elements
This document is a Petrotech, Inc. copyrighted intellectual property and may be changed at any time without notice.