Professional Documents
Culture Documents
& SPIROMETRY
INTRODUCTION 3
Based on many years of standing experience in manufacturing, design and sale of safe and
reliable equipment, BTL offers full range of non-invasive cardiology products.
The BTL cardiology products stand out for their fast and easy operation, top parameters,
modern functional
design and reliability. Reflecting the latest trends in cardiology and providing an excellent
price/performance
ratio, the BTL units are an ideal investment for medical professionals.
The product line contributes to our goal: manufacturing highly competitive products and
providing excellent customer care support to our customers world-wide.
content
CARDIOPOINT 5
ECG 7
CARDIOPOINT ECG 7
L-LINE ECG 9
M-LINE ECG 10
S-LINE ECG 11
STRESS TEST 13
HOLTER 17
AMBULATORY BP 21
SPIROMETRY 23
NETWORKING 24
TECHNICAL SPECIFICATIONS 25
sales@btlnet.com
www.btlnet.com
All rights reserved. Although every care has been taken to provide accurate and up-to-date information, no responsibility can be accepted
for any mistakes or misprints contained in this catalogue. The products and their specifications, as shown in this catalogue, may change
without notice.
CARDIOPOINT
4 5
BTL CARDIOPOINT
UNIFIED CARDIOLOGY PLATFORM
complete
solution
for cardiology
office The BTL CardioPoint is a intuitive work is ensured by Main features & advantages
versatile software solution ergonomically optimized Unified platform for all
examinations
integrating ECG, Stress user interface with
Fully customizable user interface
test, Holter, ABPM and shortened mouse tracks and Fast and intuitive work
Spirometry into one unified hotkeys. Colour schemes Product lifetime updates
platform with one patient are designed for both Configurable report profiles
database and the same dark and light ambience. Optimized colour schemes &
logic of controls for each The BTL CardioPoint can controls
module. The software be used as a stand alone Integration to clinic environment
GDT and NETworking interface
has fully customizable cardiology system, or it can
Superior measurement quality
interface, and its layout and be seamlessly integrated to
worksteps can be easily an existing ambulatory or Software modules
ECG
adapted. The operator is hospital system. The BTL
Stress test
allowed to arbitrarily add or CardioPoint is the software
Holter
move tables, ECG strips and that adapts to the user, and
ABPM
other windows. Fast and not the user to the software. Spirometry
ECG
6 7
BTL-08 L-Line
A4 PRINTOUT AND LARGE TOUCH SCREEN
The BTL-08 MT Plus ECGs KEY FEATURES CONNECTIONS & UPGRADES The BTL-08 S-Line ECGs KEY FEATURES CONNECTIONS & UPGRADES
have all of the advanced 5.7’’ colour touch-screen LAN&WiFi communication are known for their 1-channel LCD display Connection to BTL CardioPoint
112 mm printouts upgrade 58mm printouts software (except for the SD1
features of the L-Line portability and long-term model)
Battery or mains power Connection to CardioPoint PC Battery or mains power
models embedded in a options Software operation in battery mode. options Vacuum electrode system
smaller, lightweight design. Possibility to combine with The LCD screen displays Portability
connection
This ECG system has been the Spirometry Module one selected channel Diagnostics upgrade
FUNCTIONALITY (includes analysis and text
Optional Quickels Decapus and other information
designed for a broad Auto-adaptive filters for FUNCTIONALITY interpretation)
vacuum electrode system
spectrum of users. Colour outstanding signal quality
Diagnostics upgrade
such as paper speed and Loose leads indicator
touch screen, high-quality Loose leads indicator (includes analysis and text amplitude. Auto, manual and user-defined
printouts and the spirometry Auto, manual and user-defined interpretation) The user’s comfort is profiles
profiles Paediatric interpretation Alpha-numeric keyboard
option make it a powerful, ensured by the one-touch
Alpha-numeric keyboard according to patient’s age 100 µs / 40 kHz pacemaker
yet easily-operated device. 100 µs / 40 kHz pacemaker
operation and the easy-to- detection function
detection function use menu.
BTL CARDIOPOINT
PERFORM THE STRESS TEST EASILY
ARRHYTHMIA DETECTION & AUTOMATIC BLOOD PRESSURE & ST MAPS QT MODULE RISK SCORING MAXIMUM LOAD PREDICTION
ANALYSIS SPO2 MEASUREMENT As the ST-segment analysis The QT module is a unique tool The risk scoring tool uses the The software automatically
The BTL CardioPoint Stress test In order to maximize the user’s gives highly valuable information evaluating the patient’s risk of examination results to predict predicts patient’s maximum load.
detects comfort, the BTL CardioPoint about patient’s heart condition, sudden death caused by Long patient’s mortality and define It is possible to select among 8
ventricular and supraventricular Stress test supports automatic it is a matter of high importance QT syndrome. The results are the risk of CAD (coronary arterial formulas that can be used for the
arrhythmias in form of isolated blood pressure measurement. In to have effective supportive displayed in the form of curve disease). Thus, it helps decide prediction calculation depending
beats, sequences (couplets, the event a Suntech Tango M2 or tools for its clear observation. whose shape and location which further examinations the on the patient’s specific condition.
triplets and runs) and alternating a compatible bike with BP option Besides the traditional averaged indicates the survival probability patient should undergo.
arrhythmias (bigeminies and is connected, the blood pressure beat display and ST trend graph, of the patient. The tangent
trigeminies). Each time an measurement is performed the BTL CardioPoint Stress test method is a method specifically
arrhythmia appears in the signal, completely automatically. offers the ST map component – a suitable for QT measurement with
an alarm mark is displayed. Besides blood pressure, the SPO2 graphic tool displaying a spatial higher heart rates when there is
measurement can be performed orientation of ST deviations. The no clear return to baseline.
completely automatically ST maps are sorted in Cabrera
as well. manner according to spatial
orientation of horizontal and
vertical heart plane. They are the
only way to validate mirrored ST
elevation.
BTL CARDIOPOINT
OUTSTANDING SIGNAL QUALITY
INTUITIVE USER INTERFACE
BTL-08 HOLTER
3/7/12-CHANNEL ECG HOLTER MONITOR
18 holter holter 19
3/7/12-CHANNEL MONITORING TEMPLATE ANALYSIS PATIENT ACTIVITY MONITOR RELIEF & WATERFALL ADVANCED PACEMAKER PQ ANALYSIS
FOR UP TO 7 DAYS The BTL CardioPoint software not Each BTL Holter recorder has The Relief and Waterfall images ANALYSIS PQ analysis is a special
The 12-channels offer the most only sorts the heart-beats according a built-in motion sensor that provides a simplified, yet complex, The software offers a clear tool to analyze the P-Wave
comprehensive means of finding to their morphology, but it also allows the user to see exactly look at an ECG signal. This overview of all paced heartbeats. characteristics.
and tracking complex cardiac identifies whether the beats within which time periods the patient unique tool allows a physician to Furthermore, it provides a It indicates ECG strips with
issues. The 7-channel monitoring a template are homogenous or was performing some physically- immediately visually analyse all the physician with the advanced possible appearance of AV
started a new approach to Holter not. A homogenous template only demanding activities. As a result, irregularities that are not typically analysis (such as fail to capture, conduction blocks.
examinations and its popularity consists of beats having the same the graph of patient’s activity can visible when using traditional or fail to sense) Thus, it can be
stems mainly from the fact only shape, while the non-homogenous be directly correlated with the methods for ECG signal analysis. used to check the pacemaker
five leads have to be used. one may involve many types of graph of patient’s heart rate and The main purpose of both tools is functionality.
The 3-channel recording is suitable heartbeats of various shapes. other graphs as well. to easily detect Atrial Fibrillation/
for the classic, simplified Holter The non-homogenous templates Flutter and ST segment changes;
ECG. Moreover, the BTL Holter are then identified with the label both are very efficient in revealing
allows the signal monitoring for up Mixed Shapes and usually require other pathologies. The usage of
to seven days, which is especially the physician’s special attention. relief tool may significantly speed
helpful when nonpersistent The same approach is applied to up the holter record analysis.
arrhythmias are expected to occur. morphology analysis. BTL CARDIOPOINT HOLTER OVERVIEW
The software is offered in three editions:
H100 H300 H600
ECG HOLTER FEATURES & TECHNICAL DETAILS OVERVIEW
Multilevel templates o o o
There are three Holter recorders – 3-channel, 3/7-channel and finally 3/7/12-channel
Rhythm analysis o o o
3-ch 3/7-ch 3/7/12-ch
Graphical event split o
Number of channels 3 3/7 3/7/12
Pacemaker detection o o
Recording time 1–2 days 1–7 days 1–7 days
Pacemaker analysis o
Patient cable 5 lead 5 lead 5/10 lead
HRV tabular evaluation o o o
Signal quality check USB, SD card USB, SD card, BT USB, SD card, BT
HRV trends o o
LCD screen resolution 128 × 64 dots 128 × 64 dots 128 × 64 dots
ST tabular evaluation o o o
Storage capacity 2 GB 2 GB 2 GB
ST trends o o
Sampling Frequency / Resolution 8× 2000 Hz / 24 bit
QT, QTc tabular evaluation o o
Pacemaker detection 100 µs / Dedicated circuit with 40000 Hz detection function
QT, QTc trends o o
Frequency Range 0.049 Hz–220 Hz
QT/RR and QT/HR graphs o
Digital resolution 1.52 µV
PQ tabular evaluation o
Maximum electrode potential ± 393 mV DC
PQ trends o
Dynamic Range 66 mVpp
PQ/RR and PQ/HR graphs o
Common mode rejection > 100 dB (> 115 dB)
(with digital filter) Patient activity monitor o
BTL CARDIOPOINT
COMFORTABLE AND PRECISE BLOOD
PRESSURE MONITORING
BTL CardioPoint-Spiro
INFORMATION SYSTEM
Dimensions of display (mm) 118 × 89 118 × 89
Screen resolution (dots) 640 × 480 640 × 480
Keyboard combined alphanumeric and functional, touch screen buttons
Interface RS232, USB RS232, USB
Dimensions (mm) 330 × 270 × 74 330 × 270 × 74
Weight Approx. (kg) 3.2 3.2
printer
Paper width (mm) 112 / A4 trough USB
Paper type roll / A4 – office paper
Printer type thermal / external laser or ink. printer
measurement PARameter
BTPS correction automatic
Inspire / Expire yes / yes
FVC, Best FVC, FEV0.75, FEV1, Best FEV1, FEV3,
FEV6, PEF, FEV0.75/FVC, FEV1/, FVC, FEV3/FVC,
FEV6/FVC, FEV0.75/SVC, FEV1/SVC, FEV3/SVC,
FEV6/SVC, PIF, FIVC, FIV1, MEF75, MEF50, MEF25,
HL7 FEF75, FEF50, FEF25, MMEF, FET25, FET50, FVC, Best FVC, FEV1, Best FEV1, PEF, FEV1/FVC,
Forced spirometry MIF75, MIF50, MIF25, PEFT, FIF50, FEF50/FIF50, FEV6/FVC, FIVC, FIV1, PIF, MEF75, MEF50, MEF25,
DICOM FEF50/SVC, FEV0.75/ FEV6, FEV1/ FEV6, FIV1/
FIVC, VEXT, Lung age
Lung age
Technical
specifications
The healthcare industry’s and DICOM/PACS, the BTL MAIN FEATURES & BENEFITS
Flow range (litres/s) 16 l/s (inspire/expire)
increased use of the NETworking allows fully Automatic archiving
accuracy (50 ml/s to 16 l/s) ± 3 % or 50 ml (whichever is greater)
electronic medical records automatic ECG archiving Instant anytime and anywhere
Volume ranges (litres) 0.025 to 8 litres
access
has turned hospital networks for an instant, anytime Correct patients identification
accuracy (0.025 to 8 l) ± 5% or 50 ml (whichever is greater)
the hospital environment be also exported in PDF, Increasing effectivity accuracy ± 4 % for 25 °C, 30–80 % RH
workflow and allows all XML or JPG formats. The Reducing archiving costs Mains supply 115 V / 230 V, 50–60 Hz, 40 VA
All CardioPoint modalities Accumulator capacity 90 minutes
the necessary operations BTL NETworking solution supported Charging time 10 hours (if completely discharged)
needed to archive and significantly improves ADC resolution 15 bits
retrieve data. It provides examination workflow and Sampling frequency 1000 Hz
BTL-08 LC Plus BTL-08 LC BTL-08 LT Plus BTL-08 LT BTL-08 MT Plus BTL-08 SD6 BTL-08 SD1/SD3
printer
printer Paper width (mm) 112 58 58
Paper width (mm) 210 210 210 210
Paper type roll / A4-office paper roll roll
roll, fax, A5 z-folded, A4 roll, fax, A5 z-folded roll, fax, A5 z-folded, A4 roll, fax, A5 z-folded
Paper type thermal / external laser
z-folded / A4-office paper / A4-office paper z-folded / A4-office paper / A4-office paper Print type thermal thermal
or ink. printer
Print type thermal / external laser or ink. printer
Paper speed (mm/s) 5, 10, 12.5, 25, 50 5, 10, 25, 50 5, 10, 25, 50
Paper speed (mm/s) 5, 10, 12.5, 25, 50 5, 10, 12.5, 25, 50 5, 10, 12.5, 25, 50 5, 10, 12.5, 25, 50
signal processing
signal processing Number of channels 3, 6, 12 3, 6 1/3
Number of channels 12 12 12 12
Number of leads 12 12 12
Number of leads 12 12 12 12
Displayed leads 3, 6, 12 1 1
Displayed leads 3, 6, 12 3, 6, 12 3, 6, 12 3, 6, 12
3, 4, 6, 12, 3×4+1, 3×4+2, 3×4+3, 4×3+1,
Printed leads 1, 3, 6 1/1, 3
3, 4, 6, 12, 3×4+1, 6×2+1, 6×2+2
3, 4, 6, 12, 3×4+1, 3×4+2, 3×4+3, 4×3+1, 3, 4, 6, 12, 3×4+1, 3×4+2, 3×4+3, 3, 4, 6, 12, 3×4+1, 3×4+2, 3×4+3,
Printed leads 3×4+2, 3×4+3, 4×3+1,
6×2+1, 6×2+2 4×3+1, 6×2+1, 6×2+2 4×3+1, 6×2+1, 6×2+2 Transmission in automatic mode real-time, synchronic real-time, synchronic real-time, synchronic
6×2+1, 6×2+2
Pacemaker detection yes yes yes
Transmission in automatic mode real-time, synchronic real-time, synchronic real-time, synchronic real-time, synchronic
yes (dedicated Sensitivity (mm/mV) 2.5, 5, 10, 20 2.5, 5, 10, 20 2.5, 5, 10, 20
Pacemaker detection yes (dedicated circuit) yes (dedicated circuit) yes (dedicated circuit)
circuit) 250 (minimum)
Stored records (10-sec long strips) 6 6
Sensitivity (mm/mV) 2.5, 5, 10, 20 2.5, 5, 10, 20 2.5, 5, 10, 20 2.5, 5, 10, 20 400 (typical)
Stored records (10-sec long 250 (minimum) 250 (minimum) 250 (minimum) 250 (minimum) Long ECG recording 1 lead / 2 leads (min) 10/10 9/no 9/no
strips) 400 (typical) 400 (typical) 400 (typical) 400 (typical)
Long ECG recording 1 lead /
2 leads (min)
10/10 10/10 10/10 10/10 digital filters
Adaptable mains filter (Hz) 50–60 50–60 50–60
Muscle tremor filters (Hz) 35, 25 35, 25 35, 25
digital filters
0.05 (3.2 s), 0.11 (1.5 s), 0.25 (0.6 s), 0.05 (3.2 s), 0.11 (1.5 s), 0.25 (0.6 s), 0.05 (3.2 s), 0.11 (1.5 s), 0.25 (0.6
Adaptable mains filter (Hz) 50–60 50–60 50–60 50–60 Baseline filters (Hz)
0.50 (0.3 s), 1.50 (0.1 s), splines 0.50 (0.3 s), 1.50 (0.1 s) s), 0.50 (0.3 s), 1.50 (0.1 s)
Muscle tremor filters (Hz) 35, 25 35, 25 35, 25 35, 25 Automatic auto-adaptive — —
Baseline filters (Hz) 0.05 (3.2 s), 0.11 (1.5 s), 0.25 (0.6 s), 0.50 (0.3 s), 1.50 (0.1 s), splines
Automatic auto-adaptive auto-adaptive auto-adaptive auto-adaptive
user-defined profiles
No. of profiles for auto. and man. mode unlimited 3 3
user-defined No. of profiles for long ECG recording unlimited 3 3
profiles
No. of profiles for auto.
and man. mode
unlimited unlimited unlimited unlimited summary of available options
No. of profiles for long Extension of channels – – 1–3–6 / 3–6
unlimited unlimited unlimited unlimited
ECG recording Diagnostics (includes: averaging, analysis,
optional optional —/optional
text interpretation)
PC connection with software
summary of available options BTL CardioPoint-ECG
optional optional —/optional
Mains supply 100 V–230 V, 50–60 Hz Polarisation voltage ± 400 mV 100 µs / Dedicated circuit with 40000 100 µs / Dedicated circuit with 40000
Pacemaker detection
Hz detection function Hz detection function
Frequency response 0.049 Hz - 170 Hz Max. consistent voltage ±5V
Dynamic range 15.9 mV 15.9 mV
Digital resolution 3.9 µV Input impedance > 20 MOhm
Polarisation voltage ± 400 mV ± 400 mV
A/D conversion 13 bits Common mode rejection > 100 dB
Max. consistent voltage ±5V ±5V
Sampling frequency ECG 2000 Hz
Input impedance > 20 MOhm > 20 MOhm
100 µs / Dedicated circuit with 40000 automat: up to 50 prints
Pacemaker detection manual: up to 35 minutes of Common mode rejection > 98 dB > 100 dB
Hz detection function
Accumulator capacity printing
Dynamic range 15.9 mV signal monitoring: up to 120 automat: up to 30 prints automat: up to 30 prints
minutes Accumulator capacity manual: up to 30min of printing; signal manual: up to 35min of printing
approx. 4–6 hours (if completely monitoring: up to 90min (MT Plus) signal monitoring: up to 75min
Charging time
discharged)
max. 4–6 hours (if completely dis-
Charging time max. 3 hours (if completely discharged)
charged)
070-77CARDIOEN405