You are on page 1of 4

BASIC SPECIFICATIONS

BASIC SPECIFICATIONS OF THE NexWay OF THE NexWay

● Capacity and Speed ●: Applicable ● Control, Door and Operation Systems ●: Applicable −: Not applicable

Rated speed (m/sec) Operation system


Rated Number
Code number capacity of Number of
elevators Contlol system Door system 1-car selective 2-car selective Σ AI-22 group Σ AI-2200C group
(kg) persons 2.0 2.5 3.0 3.5 4.0 collective collective control system control system
in a bank
(Standard) (option) (option) (option)

1 car ●(1C-2BC) ― ― ―
P 10 750 10 ● ● ●# ●# ●#

2 cars ― ●(2C-2BC)* 1   ― * 2 ―


P 12 900 12 ● ● ● ● ●#
VVVF control with
3 cars ― ― ●(3C-ΣAI-22) ●(3C-ΣAI-2200C)
microprocessor,
VVVF control and 2-panel center
P 14 1050 14 ● ● ● ● ● Data Network opening〈CO〉
4 cars ― ― ●(4C-ΣAI-22) ●(4C-ΣAI-2200C)
System (Standard),
with multiple 2-panel side
microprocessor opening〈2S〉
P 16 1200 16 ● ● ● ● ● 5 cars modules (option), ― ― ― ●(5C-ΣAI-2200C)
(VFGH) 4-panel center
opening〈2CO〉
6 cars (option) ― ― ― ●(6C-ΣAI-2200C)
P 18 1350 18 ● ● ● ● ●
7 cars ― ― ― ●(7C-ΣAI-2200C)

P 21 1600 21 ● ● ● ● ●
8 cars ― ― ― ●(8C-ΣAI-2200C)

Notes: 1. Capacity and number of persons are based on EN81-1 (1998). Notes: * 1. When the capacity and speed exceed the range shown in the left page, the operation system 2C-2BC should be 2C-ΣAI-22.
2. Please consult our local subcontractor in the following cases: * 2. Please consult our local subcontractor, when 2C-ΣAI-22 system is required instead of 2C-2BC system.
① When the specifications are out of the above table.
② When the combination of capacity and speed with mark # is required.

Selective collective (2BC) ΣAI-22&ΣAI-2200C Group Control Systems


The system consists of call buttons in the car, and a The systems, which employ an intelligent expert
● Specifications
riser of up and down destination floor buttons installed system and fuzzy logic, are specially designed for
Rated speed 2.0 m/sec 2.5 m/sec 3.0 m/sec 3.5 m/sec 4.0 m/sec at each elevator hall (single button at terminal floors), group control of 3 to 8 elevators (as described above).
which connect electrically with microprocessors Practical information required for group control is
Maximum number of stops 48
supervising floor selection and direction of travel. A car stored in the system's memory as a "Knowledge
Maximum travel (m) 150 will respond to those car and hall calls that comply with Database". Drawing from this database, various traffic
Minimum floor height (mm) 2,500 *
its direction of service. conditions are monitored and analyzed applying IF-
When there are no more calls registered for the car's THEN decision rules to maximize the effectiveness of
Notes: 1. Please consult our local subcontractor for specifications outside these ranges.
2. * The minimum floor height 2500mm is for steel structure only. It may become more than 2500mm when car arrival chime is   direction of travel, the car's service direction is each elevator operation.
     required at each hall (AECH),or depending on sill support height. However, the minimum floor height for RCC is 2800mm reversed. The systems perform assignments to the most-used
     with standard type of sill support. locations, and thereby provide superb efficiency and
service.
In addition to the above, ΣAI-2200C system performs
optimal car allocation using Dynamic Rule-set
Optimizer.

1 2
RATED SPEED OF
RATED SPEED OF 2.0∼3.0 m/sec 2.0∼3.0 m/sec

● Car frame height (HB) according to car design and car depth
100-125 AM (min)
R1 Car frame Car designs
height (HB)
(mm) S10 S20 S30 N10 N20 N30 N40 N50 N60 N70 N80

(by owner)
Vent. fan

3450 ○ ○ ○ ○ BB≧1400 ○ ○ ○ ○

BH

BM (min)
3650 ○ ○

BB
BB<1400
Note: The dimensions HB are calculated when the ceiling height (HL) is 2300mm and without the emergency exit on ceiling.

Access door : (by owner)


Please consult our local subcontractor if required the emergency exit.

Vent. window
(by owner)
Top clearance (TC) Machine-room height (HM)

Height: 2000
JJ
● ●

Width: 1000
R2
AA
(Unit: mm) (Unit: mm)
AH

Attachment Control Control Rated speed Travel (TR) (m) Rated speed Regulation
panel panel panel
(m/sec) TR≦100 100<TR≦150 (m/sec)
EN81-1
Hoistway Wall socket
(by owner)
Intercom (option) 2.0 1760 1910
Power receiving box Lighting outlet 2.0
(by owner) (by owner)
2.5 1840 1990 2.5 2500
Machine room 3.0 2190 2340
3.0

● Reaction loads in machine room and pit (Unit: kN) ● Pit-depth (PD) *2 (Unit: mm) ● Overhead-height (OH) *2 (Unit: mm)
Hoisting hook or trolley beam (by owner)
Rated Rated capacity (kg) Rated Travel Rated capacity (kg) Rated Travel Rated capacity (kg)
speed speed TR speed TR
(m/sec) 750 900 1050 1200 1350 1600 (m/sec) (m) 750 900 1050 1200 1350 1600 (m/sec) (m) 750 900 1050 1200 1350 1600
TR≦100 2080 Cinder-concrete finish

HM (min.)
R1 91 104 108 112 118 123 TR≦100 5210 (by owner)
2.0 100<TR≦120 2800
R2 59 67 68 73 74 82 2.0 100<TR≦120 5360
2.0
120<TR≦150 − 3000 3020
2.5 P1 106 116 122 130 140 154 120<TR≦150 − 5360
TR≦100 2080
P2 96 103 107 113 119 128 TR≦100 5290
2.5 100<TR≦120 2840

TC
R1 104 108 112 118 123 2.5 100<TR≦120 5440
120<TR≦150 − 3040 3060
R2 67 68 73 74 82 TR≦100 2650
120<TR≦150 − 5440
3.0 −
P1 120 125 134 144 159 TR≦100 5640

OH (min.)
3.0 100<TR≦120 − 3130
3.0 −

Entrance height:
P2 107 111 117 123 132 120<TR≦150 3330 3350 100<TR≦150 5790

HB
HH=2100
Note: The dimensions OH are calculated when the car frame height (HB) is 3450mm.

HL
● Dimension table of car, hoistway and machine room Highest
floor

Car Internal dimensions of hoistway (mm) *2 Internal dimensions of machine room (mm)
internal

Total height
In-line arrangement In-line arrangement Facing arrangement *3
Rated Rated Number Entrance dimensions

Travel(TR)
Code (mm) 1-unit 2-unit 3-unit 4-unit 1-unit 2-unit 3-unit 4-unit
speed capacity of width
number installation installation installation installation installation installation installation installation 4 units 6 units 8 units
(m/sec) (kg) persons JJ (mm)
Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth Width Width Width
AA x BB AH x BH AH x BH AH x BH AH x BH AM x BM AM x BM AM x BM AM x BM AM AM AM
2.0
2.5 P 10 750 10 800 1400 x 1300 2000 x 2050 3900 x 2050 5900 x 2050 7900 x 2050 2350 x 3455 4200 x 3455 6200 x 3455 8200 x 3455 4200 6200 8200

P 12 900 12 900 1600 x 1300 2300 x 2050 4300 x 2050 6500 x 2050 8700 x 2050 2350 x 3455 4400 x 3455 6600 x 3455 8800 x 3455 4400 6600 8800 Lowest
floor
P 14 1050 14 900 1600 x 1500 2300 x 2250 4300 x 2250 6500 x 2250 8700 x 2250 2350 x 3655 4400 x 3655 6600 x 3655 8800 x 3655 4400 6600 8800
2.0

PD (min.)
2.5 P 16 1200 16 1000 1800 x 1500 2500 x 2250 4700 x 2250 7100 x 2250 9500 x 2250 2500 x 3655 4750 x 3655 7150 x 3655 9550 x 3655 4750 7150 9550
3.0
P 18 1350 18 1100 2000 x 1500 2700 x 2250 5100 x 2250 7700 x 2250 10300 x 2250 2700 x 3655 5150 x 3655 7750 x 3655 10350 x 3655 5150 7750 10350

P 21 1600 21 1100 2000 x 1700 2700 x 2450 5100 x 2450 7700 x 2450 10300 x 2450 2700 x 3855 5150 x 3855 7750 x 3855 10350 x 3855 5150 7750 10350
Notes: * 1. All the above dimensions are calculated based on EN81-1 (1998).
* 2. The dimensions PD, OH and BH are calculated when the counterweight without safety gear is located in back of the car. P1 P2
* 3. These machine room depth BM with a facing arrangement should be (2BH+3500) mm when lobby width is 3.5m.
* 4. Refer to page 7 and 8 for hoistway and machine room layouts with a facing arrangement. Hoistway section
* 5. The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD.
     Necessary tolerance should be separately considered for the building construction errors.
* 6. The dimensions TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table and conditions.
5 6
RATED SPEED OF
RATED SPEED OF 3.5, 4.0 m/sec 3.5, 4.0 m/sec

Vent. fan
AM (min) ● Car frame height (HB) according to car design and car depth
100-125
R1 (by owner)
Car frame Car designs
height (HB)
(mm) S10 S20 S30 N10 N20 N30 N40 N50 N60 N70 N80

Vent. window
BH

(by owner)

BB
3450 ○ ○ ○ ○ BB≧1400 ○ ○ ○ ○

3650 BB<1400 ○ ○

BM (min) = lobby width + 2BH


JJ
AA R2
AH
Note: The dimensions HB are calculated when the ceiling height (HL) is 2300mm and without the emergency exit on ceiling.

(by owner)
Please consult our local subcontractor if required the emergency exit.

Lobby width:
Attach-

3500-4500
Control Control Control Attachment ment
panel panel panel panel panel

Access door :
Elevator lobby control
Group
panel
Control
panel
Control
panel
Control
panel
Attachment
panel
Attach-
ment
panel Intercom

Height: 2000
Width: 1000
(option)

Wall socket
● Top clearance (TC) (Unit: mm) ● Machine-room height (HM) (Unit: mm)
(by owner)

Rated speed Travel (TR) (m) Rated speed Regulation


Power receiving box
(by owner) (m/sec) (m/sec)
BH

TR≦100 100<TR≦120 120<TR≦150 EN81-1


Lighting outlet
(by owner)
3.5 2520 2670 3.5 2500
4.0 4.0
3070
Hoistway Machine room

● Reaction loads in machine room and pit (Unit: kN) ● Pit-depth (PD) *2 (Unit: mm) ● Overhead-height (OH) *2 (Unit: mm)
Rated Rated capacity (kg) Rated Travel Rated capacity (kg) Rated Travel Rated capacity (kg) Hoisting hook or trolly beam (by owner)
speed speed TR speed TR
(m/sec) 750 900 1050 1200 1350 1600 (m/sec) (m) 750 900 1050 1200 1350 1600 (m/sec) (m) 750 900 1050 1200 1350 1600

HM (min.)
R1 123 127 132 133 141 TR≦100 3020 TR≦100 5970 Cinder-concrete finish
3.5 − (by owner)
R2 80 79 82 90 94 3.5 100<TR≦120 − 3370 100<TR≦150 6120
3.5 −
P1 125 131 140 151 165 120<TR≦150 3570 3590 4.0 TR≦150 − 6520

P2 115 119 125 131 140 4.0 TR≦150 − 3920 Note: The dimensions OH are calculated when the car frame   
   height (HB) is 3450mm.

TC
OH (min.)
R1 127 132 133 141

R2 79 82 90 94
4.0 −
P1 128 140 151 165

HB
Entrance height:
P2 119 125 131 140

HH=2100

HL
● Dimension table of car, hoistway and machine room Highest
floor
Car Internal dimensions of hoistway (mm) *2 Internal dimensions of machine room (mm)
internal
In-line arrangement In-line arrangement Facing arrangement *3
dimensions

Total height
Rated Rated Number Entrance
Code (mm) 2-unit 3-unit 4-unit 2-unit 3-unit 4-unit
speed capacity of width 4 units 6 units 8 units

Travel (TR)
number installation installation installation installation installation installation
(m/sec) (kg) persons JJ (mm)
Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth Width Width Width
AA x BB AH x BH AH x BH AH x BH AM x BM AM x BM AM x BM AM AM AM

3.5 P 12 900 12 900 1600 x 1300 4400 x 2100 6650 x 2100 8900 x 2100 4500 x 3455 6750 x 3455 9000 x 3455 4500 6750 9000 Lowest
floor
P 14 1050 14 900 1600 x 1500 4400 x 2300 6650 x 2300 8900 x 2300 4500 x 3655 6750 x 3655 9000 x 3655 4500 6750 9000

PD (min.)
3.5 P 16 1200 16 1000 1800 x 1500 4800 x 2300 7250 x 2300 9700 x 2300 4800 x 3655 7250 x 3655 9700 x 3655 4800 7250 9700
4.0
P 18 1350 18 1100 2000 x 1500 5200 x 2300 7850 x 2300 10500 x 2300 5200 x 3655 7850 x 3655 10500 x 3655 5200 7850 10500

P 21 1600 21 1100 2000 x 1700 5200 x 2500 7850 x 2500 10500 x 2500 5200 x 3855 7850 x 3855 10500 x 3855 5200 7850 10500
P2 P1 P1 P2
Notes: * 1. All the above dimensions are calculated based on EN81-1 (1998).
* 2. The dimensions PD, OH and BH are calculated when the counterweight without safety gear is located in back of the car.
* 3. These machine room depth BM with a facing arrangement should be (2BH+3500) mm when lobby width is 3.5m.
* 4. Refer to page 5 and 6 for hoistway and machine room layouts with an in-line arrangement. Hoistway section
* 5. The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD.
     Necessary tolerance should be separately considered for the building construction errors.
* 6. The dimensions TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table and conditions.

7 8
ENTRANCE LAYOUT
ENTRANCE LAYOUT DRAWINGS DRAWINGS

Type E-102 (standard) Type E-302, E-312 (option)

Door plan (section B-B)

Hoistway entrance

Door elevation
(section A-A)
Building structure Building structure
(by owner) (by owner)

Note: 1. Triangular key-hole is required under EN81-1. Note: 1. Triangular key-hole is required under EN81-1.
Wall and floor finishing 2. Details in sections A-A and B-B are not for Wall and floor finishing 2. Details in sections A-A and B-B are not for
(by owner) BS-476 fire rated doors. (by owner) BS-476 fire rated doors.

9 10