CHAPTER 2: SYSTEM HARDWARE POWER SUPPLY UNITS (PSU)

PSU specifications
The AC Power Injector 56V conforms to the specifications listed in Table 18.

The AC+DC Enhanced Power Injector 56V conforms to the specifications listed in Table 19.

The CMM5 Power and Sync Injector 56 V conforms to the specifications listed in Table 20.

T able 18 AC Power Injector 56V specifications

Category Specification

Dimensions 137 mm (5.4 in) x 56 mm (2.2 in) x 38 mm (1.5 in)

Weight 0.240 Kg (0.5 lbs)

Temperature 0°C to +40°C

Humidity 90% non-condensing

Waterproofing Not waterproof

Altitude Sea level to 5000 meters (16000 ft)

AC Input Min 90 V AC, 57 – 63 Hz, max 264 V AC, 47 – 53 Hz.

DC output voltage to the ODU 55V +/- 5%

AC connector IEC-320-C8

Efficiency Better than 85%, efficiency level ‘V’

Over Current Protection Hiccup current limiting, trip point set between 120% to 150%
of full load current

Hold up time At least 10 milliseconds

Table 19 AC+DC Enhanced Power Injector 56V specifications

Category Specification

Dimensions 250 mm (9.75 in) x 40 mm (1.5 in) x 80 mm (3 in)

Weight 0.864 Kg (1.9 lbs)

Temperature -40°C (-40°F) to +60°C (140°F)

Humidity 0 to 90% non-condensing

Waterproofing Not waterproof

AC Input 90-264 V AC, 47-60 Hz

Alternative DC Input 37-60 V DC

DC Output Voltage For mains input: 58 V, +2V, -0V

For DC input: Output voltage at maximum rated output


current, not more than 1.5 V below the DC input voltage.

PAGE 2-19
CHAPTER 2: SYSTEM HARDWARE POWER SUPPLY UNITS (PSU)

Category Specification
Maximum length of DC output cable: 3 meters.

AC Input connector IEC-320-C8

DC Output current 1.7A

Efficiency Better than 84%

Over Current Protection Hiccup current limiting, trip point set between 120% to 150%
of full load current

Hold up time At least 20 milliseconds

Power factor Better than 0.9

T able 20 CMM5 Power and Sync Injector 56 Volts specifications

Category Specification

Dimensions 225mm (8.85 in) × 400mm (15.75 in) × 42mm (1.65 in)

Weight 3 kg (6.6 lbs)

Temperature -40°C (-40°F) to +55°C (131°F)

Humidity 0 to 90% non-condensing

Waterproofing Not waterproof

Input Voltage ± 48 V DC

Input Power 400 W maximum

Output Voltage ± 55 V DC

Output Current 0–1.8 A per channel

Output Power 0–90 W per channel

Power Interface Terminals Two power input ports for 48 V DC Power

Data Interfaces Four RJ45 Gigabit Powered output ports “To Radios”

Four RJ45 Gigabit Data input ports “To Switch Array”

One GPS timing port (RJ-12)

One CMM5 USB Serial port for local administration

One RJ12 Daisy Chain port “IN”

One RJ12 Daisy Chain port “OUT”

Surge Suppresion Lightning Suppression for each “To Radios” RJ45 Port

Max cable length from managed 100 m (328 ft)


radios

PAGE 2-20
CHAPTER 2: SYSTEM HARDWARE POWER SUPPLY UNITS (PSU)

Category Specification

Max cable length to GPS 30.5 m (100 ft)


Antenna

PAGE 2-21