Comments resolution sheet against comments given by Bureau Veritas -

GEC reply
STRAINER DATASHEET
STRAINER DATASHEET
NOCL-KEN-GEC-ATF-PR-STR-001
Serial NO.
COMMENT REPLY
In coversheet page no. is specified as sheet 1 Noted and Updated
of 5 whereas only 2 pages are available in
datasheet one for cover page & second for
datasheet. Please provide the remaining pages
1 of datasheet or update page no. if its typo
error.

In coversheet, revision 0 is specified whereas Noted and Updated


2 in datasheet revision A is entioned. Please
confirm which is correct & update accordingly.
The finish type for flange is missing in facing & Noted and Updated
finish row of construction data. Please furnish.
3

The flange material is specified as ASTM A105 Noted and Updated


Gr. B whereas as per piping spec the flange
material is required as ASTM A105. Please
4 check & correct in flange rating & bottom
flange row of construction & construction
material data.

The Drain Connection size & type are missing Noted and Updated
5 in datasheet. Please furnish.
As per specification, for 2” & above size, Changed to Bucket type strainer
bucket type strainers shall be provided with
¾“threaded tap and solid threaded plug as
drain connection whereas in datasheet Y-type
6 strainer is specified. Please check & revise the
datasheet accordingly. Also update sketch
provided in datasheet.

As per specification, all strainers shall be Noted and Updated


supplied with spare basket complete with
7 straining element. Please furnish this
requirement in notes of datasheet.

Please update the note no. 8 as per Noted and Updated


specification as “the entire internals of strainer
8 which will come into contact with ATF to be
handled shall be epicoated.