Fresh

VOLUME 38 l
Monsoon Edition, 2012 | Analytical Sciences and Laboratory Services
Fresh VOLUME 38 • Monsoon Edition, 2012

WHAT’S

Fresh
Dear patrons,
This month of August is a sensational month for the entire
inside... world; not because of the sluggish economy but for the
reason that all the nations on this planet come together is
sports. Yes! Friends the London Olympics 2012.
Article . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pg. no.
Olympics organization is a pride for the host nation;
• Analysis of polyurethanes . . . . . . . . . . . . . . . . . . 3-5 participation in the events is the achievement for
• Determination of Formaldehyde content in sportsperson and winning a medal is a dream. Since the
textile samples – ISO 14184 . . . . . . . . . . . . . . . . 6-7 games were initiated after the world war again; the
competition is not restricted to the performance of the
• Analysis of organic acids in food . . . . . . . . . . . . . 8-9 sports persons but more and more scientific methods got
• Analysis of food packaging film by introduced for the betterment of the human energy.
Headspace GC-MS. . . . . . . . . . . . . . . . . . . . . . 10-11 The sports devices, clothing, event arena, training
• Analysis of Drug Substances in equipment etc. have gone hi-tech so as to assist the
Headache Medicines . . . . . . . . . . . . . . . . . . . . 12-13 athletes to perform better and make new records. The
science and chemistry of sports are closely associated with
each other. The polymers, used in shoes, tracks, pole
Product of the month vault, gymnastics bar grips are the best examples where
• From sample to results in seconds! the performance of these players has improved
AxION® DSA™ System Direct 2 fold in the last 20 years. The lighter carbon doped
polymers used in cycles is helping the cyclist reach the
Sample Analysis . . . . . . . . . . . . . . . . . . . . . . . . 14-15
best timings at the speed tracks of velodrome.
The sportsmen need energy to perform; which is
replenished by healthy diet and health drinks for faster
recovery. It is also observed that sports scientists are very
keen on providing comfortable clothing to sportsmen.
However performance improvement also lead to unethical
practices like doping by banned drugs. The International
Olympic committee and WADA are closely monitoring the
malpractices in the sports events and taking strict actions.
PerkinElmer analytical technologies are useful for various
testing of food, juices, packaging, textiles, polymers,
rubbers, drugs, air, drinking water and many more. In this
issue of ‘Fresh’ we have covered various applications
related to these goods and few interesting facts of the
chemistry involved.
In this month India is celebrating its independence day on
15th August. Hence overall this is a month of happenings.

Team Marketing
PerkinElmer (India) Pvt. Ltd.
Fresh Analytiacal Sciences and Laboratory Services

Analysis of
polyurethanes

PerkinElmer thermal analyzers are In this study, the polyurethane


the best tools available for the acrylate sample is from a coating on
testing of polyurethane and ethylene mold release paper which is used
monomers. Polyurethane acrylate during artificial leather molding. The
resin can be synthesized by either new DSC8000 double furnace power
thermal curing or UV curing. The compensation DSC with liquid nitro-
final product has two separate gen cooling accessory LN2 can be
phases – the soft-segment and the used to detect Tg.
hard-segment. The glass transition DSC 8000 Polyurethanes constitute a broad
temperature (Tg) of these two
class of polymers created by reacting
phases depends on the chemical
glass transition temperature of poly- a diisocyanate with a polyol. Once
composition and molecular weight
mer. However for polyurethane polymerized, of course, the polyure-
of these two phases. The interesting
acrylate, the two glass transitions are thane has a molecular weight much
mechanical property of polyurethane
weak and one of them is sub- too large to permit analysis by GC
acrylate material is largely due to the
ambient. The conventional slow heat- alone. Polymers of all types, how-
two phase morphology. Polyure-
ing rate of 10 °C/min makes it diffi- ever, may be assayed by GC and
thane acrylate is widely used as a
cult to detect these two Tg. The sen- GC-MS with the aid of analytical
coating for metals, paper, optical
sitivity of DSC can be increased by pyrolysis1 which fragments the poly-
fibers, and other materials.
increasing heating rate because the mer into characteristic compounds
Since the two phase structure is heat flow signal of DSC is propor- that are small enough to pass
important to polyurethane acrylate tional to scanning rate according to through the GC column. This frag-
material’s function, the glass transi- the basic heat flow equation: mentation process is reproducible
tion temperatures of these two and the resulting compounds are fre-
The fast scanning rate DSC tech-
phases are important parameters to quently monomeric material of the
nique is proven to be very effective
know. Differential scanning calorim- original large polymer molecule. This
in detecting weak glass transition in
etry (DSC) is generally used to detect is especially the case for polyuretha-
highly crystalline polymer like HDPE,

3
Fresh VOLUME 38 • Monsoon Edition, 2012

nes, since A urethane bond is formed when about polyurethanes, including the
pyrolysis regen- aisocyanate (R-N=C=O) reacts with an specific diisocyanate used and the
erates the alcohol. If compounds with two nature of the polyol. Although the
diisocyanate isocyanate groups and two (or more) pyrograms may be relatively simple
used, and also –OH groups are reacted, the result is a (compared to the pyrograms
provides infor- polyurethane. This class of polymers produced from polyolefins, for exam-
Clarus™ GC and mation about has a very broad range of physical ple) the major peaks relate directly to
SQ8 MS system the structure of properties, including tough clear films, the chemical nature of the
the polyol. paints, solids, foams and elastomers. macromolecule. Polyester polyols are
Information regarding additives, The component with the OH groups is generally made with adipic acid,
including copolymers and additives is called the polyol, and may take a vari- which generates a marker peak of
also produced during such thermal ety of forms, which helps dictate the cyclopentanone. (This is true for other
treatments, and helps to characterize physical properties of the polymer. In condensations polymers, such as
the polyurethane product more fully. addition, several diisocyanates are Nylons, using adipic acid as well.)
commonly used, including the most Polyether polyols produce small ether
The analytical system consisting of a
typical, toluene diisocyanate (TDI), but molecules, the diisocyanate is regener-
PerkinElmer Clarus™ GC-MS interfaced
also hexane diisocyanate (HDI), ated and generally constitutes a major
with a CDS Analytical Pyroprobe. The
diphenylmethane diisocyanate (MDI) peak. Additives, including flame retar-
Pyroprobe vaporizes the polymer and
and 5-isocyanato-1-(isocyanatomethyl) dants are frequently seen in modified
provides analyte to the injection port
-1,3,3 trimethyl cyclohexane (IDI). The polyurethanes, as are pyrolysis prod-
of the GC, which is then operated in
polyol portion of the polymer may be ucts from other polymers that may be
the same way it would be for other
made as a polyether, or as a polyester, added, such as polystyrene.
analyses. The pyrolysis compounds are
which is frequently based on adipic
introduced to the GC without a sol-
acid.
vent, so no solvent delay is needed, For more details about these
and all peaks in the chromatogram Analytical pyrolysis, coupled with gas applications please write to
are the result of constituents of the chromatography and mass spectrome- marketing.india@perkinelmer.com
sample material. try, provides significant information

For various polymer analysis


BETTER INSIGHTS From raw materials to the finished products, our
BETTER PRODUCTS comprehensive portfolio of analytical solutions is
designed to give you higher accuracy, sensitivity
and ease of use for examining the purity,
composition and performance of your plastics and
polymers.
PerkinElmer’s expertise in hyphenated technology
solutions like TGA – GCMS, TGMS, DSC-Raman, Pyris I TGA-GCMS Hyphenated System
UV-DSC, TG-IR, etc., ensures characterization of
complex material and components with better
insights.

For further information log on to www.perkinelmer.com/polymer

PerkinElmer (India) Pvt. Ltd.


Tel: +91-22-3326 1700, Fax: +91-22-3326 1790, +91-22-3326 1791
Email: marketing.india@perkinelmer.com
www.perkinelmer.in

4
Fresh Analytiacal Sciences and Laboratory Services

Chemistry of running track


Modern sports especially the track performance. Whether it is an events. Also, there are many track
and field events are emerging as indoor or outdoor running track, construction contractors available
high tech games. Every fraction of the surface must be flexible, in the market. The Seal-Flex track
a second leaves the record of the durable, and intended for high surface is one of the best options
athlete way behind. Normally the performance training and for running. The Seal-Flex mixture
games are held every four years competition. is composed of marooned rubber
and sportsmen prepare themselves particles surrounded by a rough
Many controversies and injuries
to beat the records. For any runner latex mixture and permanently
have occurred in the past because
the foot hold and grip to the bonded to an asphalt substrate.
of poor running track surface.
ground surface is very important. This formula creates a tough and
Many star competitors refused to
Harder the push and stronger the perfect mat like surface. The next
participate in major events. At
grip makes him or her to clock the in the list is the excellent quality
games in Atlanta even the world
best timing. The weather also play Gen-Track running track surface
champion athlete refused to
a vital role in the performance. that is easy to set up and maintain.
participate, and the common
Providing the best running track reason was hard track. It is quiet The Beijing Olympics that were
surface to athletes is the basic natural that, to achieve glory, held in China provided the fastest
requirement in this modern world. athletes try to run as fast as they running track surface in the history
The art of preparing competitive can, hence, it is necessary to of Olympics. Several researches
track surface at low cost has been provide them with obedient tracks. has concluded that the running
practiced by most specialists who The basic is a hard surface could surface made of asphalt and stone
prepare running tracks. Many be favored for sprinting while base, polyurethane surface, and a
runners at high school levels in the more cushioning track is preferred butyl rubber layer gives the best
United States are reported to be for long distance running. results. Finally, the track surface is
wounded because of rough tracks. finished with fixed ethylene
In recent days, the synthetic
The surface on which you run propylene diene monomer
running track surface has been
plays a major role in your particles for higher gripping.
preferred the most in many major

5
Fresh VOLUME 38 • Monsoon Edition, 2012

Determination of Formaldehyde
content in textile samples – ISO 14184
Formaldehyde urea-formaldehyde resins. In throat; teary eyes etc. Any allergic
wooden articles such as plywood, it skin reaction can lead to cancer.
Chemically formaldehyde is com-
is used as binder. The textile industry Formaldehyde released in environ-
posed of three elements Carbon,
uses formaldehyde for multiple ment due to industrial waste or
Hydrogen, and Oxygen. Formalde-
applications such as to finish apparel uncontrolled forest fires again lead
hyde has a pungent odor and is very
fabrics, for fire retardation process, to contamination of rain water,
soluble in water. It is usually
for water repellency, stiffness and oceans or surface water.
available as an aqueous solution
wrinkle resistance in fabric.
known as formalin. Apart from Regulations
industrial manufacturing of formal- Potential health and
Regulatory bodies have specification
dehyde, an uncontrolled forest fires environmental effects
limits for the release of formalde-
are another source of formaldehyde
Even though formaldehyde has a lot hyde from textile materials. The ISO
released in an open environment.
of industrial applications, there are 14184 specifies a method for deter-
Industrial applications potential health and environmental mining the amount of free formal-
effects due to Formaldehyde. dehyde and formaldehyde extracted
Formaldehyde is used for several
Breathing formaldehyde vapors can partly through hydrolysis by means
applications such as manufacturing
result in irritation of nerves in the of a water extraction method. The
of wooden articles, paint, paper,
eyes and nose, which may cause method can be applied to the test-
and textile. The paper industry uses
burning or itching sensations, a sore ing of textile samples in any form.

6
Fresh Analytiacal Sciences and Laboratory Services

The procedure is intended for use in Corr. Abs Vs Conc.


the range of free and hydrolyzed y = 0.142x + 0.040
R² = 0.997

formaldehyde on the fabric between


Corr Abs
20 mg/Kg and 3500 mg/Kg when
Absorbance
determined by this method1. The
lower limit is 20 mg/kg. Below this
limit the result is reported as ‘not
detectable’.
Concentration (µg/mL)
Analytical technique
Figure 1: Regression curve for Formaldehyde Figure 2: PerkinElmer Lambda Series
The test method specified in the ISO calibration standards. 25/35/45UV/VIS Spectrophotometer
14184 is based on UV-VISIBLE
spectroscopy technique. A standard
regression curve is generated by
measuring the absorbance of series
Chemistry of
of formaldehyde calibration
standards. The absorbance measure-
ments are carried out at 412 nm
sportswear
wavelength using 1 cm quartz Sports clothing has come along
cuvette. Before measurement way from the cotton vestand
calibration standards need to be shorts. A whole array of technical
treated with Acetylacetone reagent fabrics are now available,
and kept at 40 degree Celsius. The designed to enhance performa-
sample preparation includes weigh- nce, increase comfort and protect
ing of 1 gm of sample and followed the athlete. One of the most
by the similar color development pro- familiar – and important – fibres
cedure used for calibration stan- used in sports clothing is Lycra, or
dards. The possible interferences dur- skin, as they have four channels
elastane. This polyurethane –
ing the absorbance measurements running along them to speed up
polyuria copolymer was invented
can be identified and then the transport of water along the
more than long ago by scientists.
confirmed using Dimedone reagent. fibre. This also makes the fabric
The elastane fibres are combined ‘breathable’ has hollow fibres,
A typical regression curve obtained
with other fibres, such as nylon or which trap air. Fabrics made with
for formaldehyde calibration
standards is shown in the figure polyester, and woven into fabrics this fibre give good insulating
1. The measurements were carried that stretch and retain their shape, properties, yet are lightweight.
out using PerkinElmer Lambda 35™ all owing clothes that cling to the They also dry quickly.
UVVIS spectrophotometer as shown skin to be made. It is now used in
It expels sweat nearly eight times
in the figure 2. a wide range of sports clothing,
as fast as polyester, which was
from swimming costumes to
particularly important in the very
cycling kit where a close fit is
Table 1: Instrument parameters humid conditions where the
required, to looser clothing where
Wave length 412 nm Olympic competition was held. By
its elasticity enhances both
Measurement mode Absorbance incorporating additives into yarns,
comfort and fabric performance.
Cell path length 10 mm the properties of the fabric can be
Cell material Quartz
The shape of the fibres can have
enhanced by reducing lactic acid
an effect on a fabric’s properties.
formation and hence the muscle
These technical fibres are designed
fatigue.
to wick moisture away from the

7
Fresh VOLUME 38 • Monsoon Edition, 2012

Analysis of organic acids in food


In food, organic acids originate from type and amount is constantly was completed on a PerkinElmer
the natural biochemistry processes monitored to insure the food is safe Brownlee™ Analytical C18, 5 µm 100
or are added as preservatives, for consumption and complies with mm x 4.6 mm column. The run time
acidulants and stabilizers. Organic regulations. was approximately 5 min. with a
acids contribute to the sensory back pressure of 2000 PSI (138
The PerkinElmer Flexar™ FX-15 with
properties of foods by providing bars). Alternatively, instead of a
Flexar FX Photodiode Array Detector
taste and aroma. Citric acid is widely phosphate buffer a similar
(PDA) provided the UHPLC platform
used in soft drinks to provide them separation was obtained with
for this application. The separation
with the sour taste of citrus fruit; 0.02% formic acid.
fumaric acid is used as an acidulant
Analysis of organic acids in reverse
in baking powder. In the food
phase LC is challenging due to the
industry, organic acids are used as
low retention factor and subsequent
antimicrobial agents: formic acid is
elution close to or within the void
used as an antibacterial agent in
volume. In aqueous solutions,
livestock feeds where it can kill
organic acids typically dissociate into
salmonella bacteria; proprionic acid
their ionic form, which tend to be
is used as preservative in baked
more polar and elute earlier than the
goods where it prevents the growth
nonionic form (In reverse phase LC,
of mold and kills some bacteria. The
the more polar a compound, the
use of organic acids in food is
faster it elutes). By lowering the
regulated in most countries, and the Flexar™ FX-15 UHPLC system

8
Fresh Analytiacal Sciences and Laboratory Services

mobile phase pH, ionization is


prevented causing longer retention
and improved resolution between
peaks.
With only one injection, a spectrum
of each acid can be obtained and Fumaric acid Proprionic acid Citric acid Succinic acid
each wavelength maximum can be
determined enabling a suitable
setting for the analysis. With
PerkinElmer’s Chromera® software
supporting the PDA, a spectral
library can be created and used to
confirm the identity of peaks in Tartaric acid D-isoascorbic acid Acetic acid Formic acid
samples.
PerkinElemer’s PDA provides a such as spectral library creation, and Courtesy: Njies Pedjie, PerkinElmer, Inc.
rugged and accurate detection over peak purity, spectra 3D and contour Shelton, CT 06484 USA
a range of 190 nm to 700 nm maps, which are powerful tools for
encompassing UV and Vis interrogating the information For detail application note and system
wavelengths. The PerkinElmer content of a 3D photodiode array configuration please write to
Chromera software offers many data chromatogram. marketing.india@perkinelmer.com
acquisition and processing features

Chemistry
It’s important to drink when they do drink sufficient plain water,
exercising – it’s easy to become there is a risk that the level of salt
dehydrated as so much water is in the blood will fall to dangerous

of juices
lost in sweat. But it’s not only water levels.
that’s lost – sweat contains salt and
Electrolytes, including sodium and
other essential chemicals and then,
potassium salts, replace those lost
of course, the energy that’s been
in the sweat. The carbohydrates are
burnt up needs to be replaced.
also important, as they replace the
A steady stream of new sports ‘fuel’ that has been burnt by the
drinks have appeared on the muscles. These might be glucose,
shelves, and today there are many fructose, maltodextrinor even
sophisticated products that contain sucrose. A number of sports
chemicals designed to aid recovery. recovery drinks also contain
Sports drink contains three proteins. The aim here is to
essential components – water, increase the levels of glycogen and
electrolytes and carbohydrates. protein in the muscles, and help
Water on its own isn’t enough – it muscle repair and growth. Some of
quenches the thirst too quickly and these drinks also contain amino
there is a danger that the athlete acids, the chemical building blocks
will remain dehydrated. Even if that make up proteins.

9
Fresh VOLUME 38 • Monsoon Edition, 2012

Analysis of food packaging


film by Headspace GC-MS
Food-packaging material is typically Later, this test was expanded to
manufactured as a thin film and extract a headspace sample out of
coated with inks which usually the mason jar by syringe and then
contain multiple, harmful, volatile injected into a gas chromatograph
organics. Therefore, they must be (GC) for quantitative analysis. This
carefully monitored and quantitated produced significantly better results
to ensure that the amounts are and provided laboratories with a
limited. Traditionally, the test for quantitative number. This process is
solvent materials in food packaging still very time-consuming and labor
film was performed using a intensive as a result of the number samples that can be analyzed each
technique of heating a square meter of manual steps involved. The day. The technique demonstrated
of the film material inside a mason manual process of cutting food here will greatly improve the
jar. This jar is then opened and packaging, placing it in a mason jar, efficiency and throughput of this
tested (by smell) for volatile organic heating the jar, and manually analysis. This analysis can be
compounds. collecting a sample for GC analysis completely automated using a
dramatically limits the number of PerkinElmer TurboMatrix™

10
Fresh Analytiacal Sciences and Laboratory Services

Headspace (HS) sampler with the used for up to 100 times lower
Clarus® Gas Chromatograph/Mass detection levels. The shaker option
Spectrometer (GC-MS) This system on the headspace was utilized for a
passed all the requirements for faster equilibration of the solid film
food-packaging analysis. material. The headspace was
controlled using the Turbo Matrix
remote control software and was
coupled to the Clarus GC-MS. The
Clarus GC was equipped with a
programmable split/split less (PSS)
injector and programmable
heated headspace technique would
pneumatic control (PPC).
allow for a flame ionization detector
Deactivated fused silica (0.32 mm)
(FID) to be used as a substitute for
transfer line connects the Turbo
the MS detector. While the MS gives
Matrix HS Trap to the Clarus GC.
a positive identification as well as
The GC column was directly
selectivity, the FID can be used in a
connected to this transfer line using
Experimental majority of standard QA/QC
a universal union The Clarus MS was
The first food packaging film used environments.
controlled via TurboMass™ GC-MS
for this experiment was from a software and operated in electron The cookie package/wrapper had
typical package of cookies. This film ionization (EI) mode. approximately 0.22 mg/m2 of
was cut into squares: 325 cm2 solvents found. However, Propanol
The headspace system enabled the
pieces. The typical volume used in a was very significant, making up the
method to be set up and run
mason jar is a square meter but this large majority of the total solvents
unattended with no sample
volume is not required for the identified. The cookie wrapper also
preparation. This eliminated the
headspace sampler. The desired had a lower level of interferences
need for mason jars and operator
sensitivity can be reached with from outside sources.
attention. In addition, the system
significantly lower quantities. The
The shopping bag (purple) had
second packaging material tested
approximately 0.32 mg/m2 of total
was obtained from a shopping bag
solvent material (of the six solvents
that you would typically find at a
tested) – This represented a very
department store. The 325 cm2
good response of all six solvents. In
pieces of film were added directly to
addition, there is a significant
a 22-mL headspace vial. The vial was
amount of other materials found in
then sealed with silicone/PTFE septa
the food film. This is evident in the
In addition, a calibration standard
chromatogram shown on. Because
was prepared to get an estimate of
of the ability of the MS to extract
the expected concentration of the
only the required ion from the
typical solvents. This standard was
component of interest, this
prepared by adding 4.7 µg of each showed a significant amount of interference was not an issue.
solvent in a 22-mL headspace vial. sensitivity for the required
Courtesy: Miles Snow and Heidi Grecsek,
The instrument used for this analysis components, demonstrating the
PerkinElmer, Shelton CT USA.
was a Turbo Matrix Headspace Trap ease of setup methodologies of
sampler run in headspace-only many types of food packaging at
mode. This bypassed the trapping many different levels.
For detail application note and
capability. If extra sensitivity is The significant response of the method parameters please contact
required, the trap option could be volatile solvent material by this marketing.india@perkinelmer.com

11
Fresh VOLUME 38 • Monsoon Edition, 2012

Analysis of Drug Substances in


Headache Medicines
Acetaminophen and aspirin are the headache medicines is acetylsalicylic formulations, caffeine not only
drugs of choice used to relieve the acid (aspirin), which is an analgesic, increases the effectiveness of the
symptoms of common headache. antipyretic and anti-inflammatory two drugs but it also stimulates the
Acetaminophen, which is also called drug. Despite its usefulness, aspirin central nervous system and
paracetamol, is widely used as a has a harmful side effect. temporarily wards off tiredness. The
pain reliever (analgesic) and fever hepatotoxicity of acetaminophen
For many people it can cause or
reducer (antipyretic). Because of its combined with the risk of stomach
exacerbate gastrointestinal ulcers by
fast onset (eleven minutes after bleeding linked to aspirin are serious
destroying the mucosal lining. This is
intake), acetaminophen is very health problems that can be
a major setback for a medicine that
effective. However, every year its prevented by accurate label claims
is otherwise very inexpensive and
misuse (dose exceeding the daily and proper medical indications. That
can also be used for its antiplatelet
adult limit of four grams) can cause is why in the pharmaceutical
effect to prevent heart attack and
fatal liver damage. In fact, industry, routine assay testing to
stroke. In formulations specially
acetaminophen toxicity is the main ensure the accuracy of the amount
designed to treat common
cause of acute liver failure and of active ingredients is a standard
headaches (tension headache),
accounts for most drug overdoses in procedure and also a part of the
acetaminophen and aspirin are often
the United States. The other food and drug administration (FDA)
combined with caffeine. In these
common active ingredient in requirements.

12
Fresh Analytiacal Sciences and Laboratory Services

A PerkinElmer Flexar™ FX-15 UHPLC


system fitted with a Flexar™ FX PDA
photodiode array detector was the
platform for this experiment. The
Sports Headache
separation was achieved using a According to Western
PerkinElmer Brownlee SPP C-18, 2.7 biomedicine there are three types
µm, 100 x 2.1 mm column. The run of primary headaches, that is
time was 4.4 minutes with a back headaches that are not a result of
pressure of 4000 PSI (276 bar). another disease process. These
are migraines, cluster headaches
and tension headaches. Tension
Most headaches are fairly
headaches are the most common
harmless and the pain will
type of primary headache.
gradually ease away by itself with
With regard to athletes, muscle no further repercussions. In some
tension headaches (MTHs) tend cases however it can be
to occur during or after sports necessary and worthwhile to seek
related activities. These further diagnosis. If you have
headaches commonly involve rarely experienced headaches
referral patterns from facet joint before and find they have started
degeneration and soft tissue increasing in frequency or
PerkinElmer Flexar™ UHPLC system with
DAD detector
indurations of the cervical and intensity then you may want to
shoulder region. see your doctor.
Initially, the USP method was
implemented as it is with a
conventional C18, 100 x 4.6 mm,
5 µm particle size HPLC column with
resulting in the improvement of the Excellent method performance was
1.0 mL/min flow rate and 45 °C; all
UV absorbance up to fivefold. achieved. The linearity of the analysis
the peaks eluted within 12 minutes.
shows R-squared values of 0.9999
By using a shorter column with
or 1 and precisions values ranging
smaller particle size (PerkinElmer
from 0.58% to 0.98% RSD. Details
Brownlee SPP C18 100 x 2.1 mm,
of the method performance and
2.7 µm) at 55 °C, and by using the
results of the samples tested are
mobile phase as diluent instead of
presented in the following table.
the mixture of methanol and glacial
acetic acid (95:5) called for by the
USP method, the pressure stabilized
at about 4000 PSI and the run time Conventional C18 analysis of standard
was dramatically reduced from 12
minutes to 4.4 minutes. Moreover,
the resolution and sensitivity were
significantly improved. Prior to
running the sample, from one
The detail sample preparation and
injection of the standard, the
standardization is available in the
maximum wavelength for each peak
application note from PerkinElmer.
was determined and the wavelength Peaks of drug substances in generic Please log on to www.perkinelmer.in
recording setting was optimized, headache medicine

13
Fresh VOLUME 38 • Monsoon Edition, 2012

Product of the month

From sample
to results
in seconds!

AxION® DSA™ System Direct Sample Analysis


The innovative AxION® DSA™ system With easier and faster DSA™ the speed and simplicity of the DSA™
brings a whole new level of ease, technology from PerkinElmer. This coupled with the fast acquisition
productivity and enhanced breakthrough approach to sample rates of an MS, high quality results
performance to any laboratory. No introduction offers a robust can be obtained in a fraction of the
up-front chromatographic alternative to front-end GC or LC time of other systems.
separation, lengthy method separation systems, enabling users
Switching between a DSA™ and LC
development, or sample preparation to take advantage of: Instant sample
system can be done in less than
is needed when using the AxION® introduction as Ionization occurs
2 minutes without venting the mass
DSA™ system within the enclosed portion of the
spectrometer.
DSA™ system, at the entrance to the
It is possible to take virtually any
mass analyzer, generating clean By coupling the AxION® DSA™ with
sample and run it directly through a
molecular ions without any required the AxION® 2 TOF MS, laboratories
Time-of-Flight Mass Spectrometer
chromatographic separations or can experience a whole new level of
(TOF) with
sample preparation. simplicity and productivity while
• No necessary up-front chromato generating confident results.
It is Faster analysis as it eliminates
graphic separation. Designed and engineered together,
multiple steps from the workflow, a
• No complicated method develop the two components of the AxION®
typical analysis can be condensed
ment. DSA/TOF system seamlessly integrate
from ~25 minutes to just 25 seconds
• No time-consuming sample with one another, bringing together
and with Immediate results due to
preparation. a series of innovative features to

14
Fresh Analytiacal Sciences and Laboratory Services

PerkinElmer’s unique AxION® DSA™ system delivers fast answers on liquid and solid samples without time-consuming up-front sample preparation.

deliver exceptional sensitivity: Take the Direct Route to Faster, • No caustic solvents or
Easier Analyses. waste – Eliminates user exposure
Patented Atmospheric Pressure
and greatly reduces costs.
Chemical Ionization(APCI) design – From environmental labs to
• No dangerous off-gassing into
Prevents ion suppression and pharmaceutical companies, food
the lab – Excess sample is
eliminates metastable ions for safety to forensics, the AxION® DSA™
removed through an integrated
clearer, more definitive data. system promises a breakthrough
exhaust line.
Entirely enclosed housing – Prevents level of performance and
• Quiet operation – Ensures a safer,
atmospheric contamination of productivity across a broad array of
more pleasant working
samples, decreasing background ions applications.
environment.
in your data. A More Secure, Efficient and
• Rapid analysis
Ability to introduce additional Productive Environment
time – Reduces overhead
additives – offers the flexibility to Innovative and user-friendly, the operating costs.
adjust analytical conditions for AxION® DSA/TOF system offers a
increased sensitivity. range of features and benefits that
Time-of-Flight MS technology – make it a better solution for your For more information on the
analysts, your business, and the AxION® DSA™ system, visit
Provides exact mass performance for
planet: www.perkinelmer.com/DSA
clear, unambiguous results.

Finally reproducibility comes to SPE


With the innovative line of Supra-Clean™ silica-based and
Supra-Poly™ polymer-based Solid Phase Extraction (SPE)
cartridges and columns, sample preparation becomes faster,
easier and more efficient. Columns are evenly and consistently
filled with particles sized for optimum distribution, delivering
‘JUST TRY IT’ superior reproducibility and superior results.

SPE PerkinElmer (India) Pvt. Ltd.


Tel: +91-22-3326 1700, Fax: +91-22-3326 1790, +91-22-3326 1791
Email: marketing.india@perkinelmer.com
www.perkinelmer.in

15
WITH YOU
EVERY STEP
OF THE WAY

At PerkinElmer, we design, manufacture and deliver advanced technology solutions. From helping you choose the right instrument
to providing you quality services and consumables, we are there with you to be your partner in analytics.

Now, A DEDICATED CONSUMABLES TEAM is at your service for


timely delivery of quality consumables.

East Zone West Zone


Lipi Ghosh Esha Lamba
Cell: +91-90519 43332 Cell: +91-88792 50607
E-mail: lipi.ghosh@perkinelmer.com E-mail: esha.lamba@perkinelmer.com

North Zone South Zone


Surendra Singh Deepali Magadum
Cell: +91-88782 22104 Cell: +91-88792 50617
E-mail: surendra.singh@perkinelmer.com E-mail: deepali.magadum@perkinelmer.com

PerkinElmer (India) Pvt. Ltd.


G-Corp Tech Park, 8th Floor, Near Hypercity Mall, Ghodbunder Road,
Kasarvadavali, Thane (West) – 400 607. India.
Tel: +91-22-3326 1700, Fax: +91-22-3326 1790, +91-22-3326 1791
Email: marketing.india@perkinelmer.com
www.perkinelmer.in