Smart and Flexible Solutions
NEW PHOTO
The new improved TVR II includes new features Indoor air quality
like simultaneous heating and cooling using The TVR II system while cooling or heating also
the new Heat Recovery series and at the same dehumidifies the indoor air and independently
time reducing the energy consumption while filters the air in each zone with no possibility of
maintaining optimum climate conditions of the cross contamination between independent zones.
building using it.
All functions necessary for filtration, cooling and
The new improved TVR II achieves higher levels of energy efficiencies in heating, ventilation and dehumidification are
both cooling (EER) and heating (COP) than the TVR, the new product fully integrated within the TVR II system.
accomplishes this by a utilizing an optimized fan design with a DC
fan motor, an improved high performance heat exchanger, Brushless The indoor air quality can be improved when
Reluctance DC inverter scroll compressors and intelligent defrost. pretreated outside air is introduced in the
building either through direct connection to the
Like its predecessor, TVR II can be applied as the main HVAC system in
indoor units (4-way cassette units) or through
a building or as a supplemental system that coordinates with an existing our new 100% fresh air concealed units.
HVAC installation to meet different application requirements.
The TVR II system can handle the integration with
The TVR II is ideal for buildings that have different requirements for future external fresh air through different solutions.
tenants, for buildings requiring tenant by tenant installation, operation
and billing. The compact size of the indoor units, the small footprint and
modularity of outdoor units and the use of small refrigerant pipes to
transport energy between outdoor and indoor units make this product the
ideal solution for existing buildings.
Individual control
The use of individual LCD zone controllers, allows users to meet their
individual comfort needs as the TVR II system will manage the refrigerant
flow to each individual zone to achieve the required cooling or
heating needed.
The controls of the TVR II are integrated on the products from the
factory, and when combined with available remote temperature sensors,
programmable controllers, centralized controller or integrated into a TVR™ II’s individual independent control per zone
Building Management System (BMS) you will ensure the most efficient
and reliable operation of the building climate possible.
3 VRF-SLB005-EN
TVR™ II Advantage
II
thus realizing energy savings. The capacity is controlled intelligently and ™
4 VRF-SLB005-EN
Simultaneous Heating and Cooling
Heat Recovery
The new TVR™ II heat recovery systems provide
for simultaneous cooling and heating while
achieving a better energy efficiency. TVR II Heat Pump system
Example of TVR II
Heat Recovery system
5 VRF-SLB005-EN
DC Inverter Advantage
Energy Saving Graph 1
The introduction of high efficiency DC inverter scroll compressor driven
by the latest in control technology is designed to provide more precise
operation and improved system efficiency.
The control system uses PWM (Pulse Width Modulation) control that Graph 2
optimizes the efficiency once the set temperature is reached, avoiding
temperature fluctuation and thus reducing the power consumption.
Traditional compressors require a minimum time between start and stops Longevity
which lead to large fluctuation of indoor temperature. The DC Inverter scroll compressors do not start
and stop all the time and thus will have a longer
Graph 2: With advanced digital variable refrigerant flow control technology, lifetime compared to standard compressors used
TVR™ II system can accurately control the room temperature within a in traditional systems.
narrow temperature band thus avoiding wasting energy and creating the The electronic control can adjust/optimize the
most comfortable environment. The set point will be stable at +/- 0.5° C. compressor’s working conditions in tougher
conditions, by changing the compressor speed
TVR™ II Energy Efficiency during cold winter conditions or high summer
outdoor temperatures. This drastically extends
the lifetime operation of the compressors.
EER (W/W)
5 The TVR II system’s auto diagnostic features
COP (W/W)
4.5 4.29 4.39 4.14 4.17 carefully monitors continuously the complete
4.02 4.02
3.89
4 system and allows fast troubleshooting with the
3.70
3.5 3.25 3.21 display of alarm codes on controllers or through
3
the BMS interfaces.
2.5
2
1.5
1
0.5
0
4TVH0086 4TVH0096 4TVH0115 4TVH0140 4TVH0155
6 VRF-SLB005-EN
DC Inverter scroll compressor
technology advantages
• New structure-enhanced mid-frequency Environment - R410A refrigerant
performance The TVR™ II system operates with the highly
• Specially designed scroll profile for R410A efficient R410A refrigerant with zero ozone
layer depleting potential. R410A provides
• Advanced permanent magnet DC motor increased system performance and heat
improves the low frequency band transfer resulting in reduced pipe sizes, reduces
performance refrigerant quantity and installation cost savings.
7 VRF-SLB005-EN
New System Features
The TVR™ II product portfolio offers a wide range of outdoor units to meet the right needs of different
applications. There are four different types of outdoor units that can be matched to our new TVR II
indoor units:
• Mini TVR II: Capacity range from 40 to 55 MBH in 50 and 60 Hz.*
• Modular TVR II Heat Pump: Capacity range from 86 to 620 MBH in 50 and 60 Hz*
• Individual TVR II Heat Pump: Capacity range from 180 to 290 MBH in 50 and 60 Hz*
• Modular TVR II Heat Recovery: Nominal capacity range from 86 to 288 MBH in 50 and 60 Hz*
* see outdoor unit specs for more details
II
address manually, ™
Identify
DC INVERTER
one by one
DC INVERTER
This new DC fan motor also reduces noise level when working in certain
part-load conditions
8 VRF-SLB005-EN
Auto-rotation of Outdoor Units
When more than one outdoor unit are installed together as a modular system, the TVR™ II system rotates the master’s unit
automatically to ensure a longer life cycle of the complete system. This is rotation takes place when the unit re-starts operation
after reaching a setpoint, after the oil return process, and after the defrost process (in heating operation).
Heating Priority
(default)
9 VRF-SLB005-EN
Flexibility & Reliability of TVR™ II System
Piping Length Flexibilities
The unique concept of a pre-engineered system that arrives on the jobsite A
with a predefined piping layout per system and the necessary piping kits DC INVERTER
II
™
The actual piping length from the condensing unit to the indoor unit
furthest away is 150m (175m equivalent) up to a total piping length
of 500m**. B
The height difference can be 70m equivalent for Outdoor Units being D
installed on the roof and 70m lift as well for Outdoor Units installed below
or on ground level. Contact your local office if over 50m lift is required
when outdoor units are installed on ground level.
C
Modular Design
By the compact modular design the TVR II Outdoor Units can be installed
in rows and manifold in series together to maximum 180kW, with 64 indoor
units connected, providing a clean accessible installation. The 180kW
Outdoor Unit is however capable to control down to a 3.6kW capacity with Maximum Actual piping length (A+B+C) 150m
only one inverter compressor running. Maximum height between indoor units (D) 15m
Maximum height between indoor units and outdoor 70m*
The combined compressors will sequentially increase the capacity using the units (B)
multiple inverter and on off compressors. Total Actual pipe length 500m**
* Contact your local office if a job requires more than 50m height.
The compact shape allows transport by elevator. ** for systems > 85kW
Back Up function
Inverter Compressor When a module fails, whether it is a slave unit or
ON/OFF Compressor a master unit, the other modules can continue to
Linear control from 2% to 100% work together as one system provided the gas/
liquid valves of the broken down unit are closed.
0% Load 100%
10 VRF-SLB005-EN
Operation Range
[°C]
• The HP systems can provide either cooling or heating, while the HR
50 TVR II HP TVR II Mini TVR II HR
systems can provide cooling and heating simultaneously. 48°C 48°C 48°C
43°C
40
• The TVR™ II mini condensing units have a low ambient operation kit 30
30°C
27°C
standard therefore the cooling performance and the intelligent controls 20
27°C
25°C
-20
Indoor comfort level
• The integration of DC inverter technology used in the condensing unit
results in an industry leading low noise level. 57 dB(A) at 1m for a 28kW
• The variety of ducted indoor units allow
Outdoor Unit.
for a flexible design meeting any sound
• The noise level of the indoor units is low due to the specially designed requirements per zone.
fans and heat exchanger designs
II
™
DC INVERTER
21
dB (A)
20 dB (A) 30 dB (A) 40 dB (A) 50 dB (A)
Speak in a low voice Quiet language Quiet reading room Quiet office
at 1/5m away laboratory
Noise decibel
* applicable for low air volume operation of 4TVW0007 units.
11 VRF-SLB005-EN
Outdoor Units
12 VRF-SLB005-EN
Mini TVR™ II Condensing Units - 50Hz
Model Numbers 4TVH0040BB0 4TVH0048BB0 4TVH0055BB0 4TVH0040BD0 4TVH0048BD0 4TVH0055BD0
Power Input V/Ph/Hz 220-240/50/1 220-240/50/1 220-240/50/1 380-415/50/3 380-415/50/3 380-415/50/3
kW 12 14 15.5 12 14 15.5
Capacity
Btu/h 40,900 47,800 52,900 40,900 47,800 52,900
Cooling Power Input W 3250 3950 4520 3250 3950 4520
Capacity Range (50% - 130%) MBh 20 - 53 24 - 62 26 - 68 20 - 53 24 - 62 26 - 68
EER W/W 3.69 3.54 3.43 3.69 3.54 3.43
kW 13.2 15.4 17 13.2 15.4 17
Capacity
Btu/h 45,000 52,500 58,020 45,000 52,550 58,020
Heating Power Input W 3470 4160 4770 3470 4160 4770
Capacity Range (50% - 130%) MBh 23 - 58 26 - 68 29 - 75 23 - 58 26 - 68 29 - 75
COP W/W 3.8 3.7 3.56 3.8 3.7 3.56
Cooling operation range C -15 C ~ 48 C -15 C ~ 48 C
Heating Operating range C -15 C ~ 27 C -15 C ~ 27 C
Air Flow (H/L) m3/h 6000 6000 6000 6000 6000 6000
Sound Pressure (H/L) dB(A) 57 57 57 57 57 57
Fin Type Hydrophilic aluminum Hydrophilic aluminum
Dimensions (W/H/D) mm 900 /1327 /320 900 /1327 /320
Net weight kg 95 95 100 95 95 102
Refrigerant R410A R410A
Refrigerant Charge kg 3300 3900 3900 3300 3900 3900
FV50S “FV50S “FV50S
Refrigerant Oil ml FV50S 870ml FV50S 1400ml
870ml+630ml 870ml+630ml” 1400ml+250ml”
Liquid Side mm 9.52 9.52 9.52 9.52 9.52 9.52
Gas Side mm 15.9 15.9 19.1 15.9 15.9 19.1
Refrigerant Piping Max. Equivalent Pipe Length m 70 70
Max. Height difference between IUs m 8 8
Max. Height difference for OU above IU m 30 30
Max. Amount of IUs connected to OU 6 6 7 6 6 7
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1m in front of the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
13 VRF-SLB005-EN
TVR™ II Modular Heat Pump Outdoor Units
Condensing units - 60 and 50 Hz
• Choice of 3 ~ power supplies:
50 Hz 380V-415 V
60 Hz 380V-415 V
60 Hz 220V
• All TVR II outdoor units have the same height and depth allowing for 4TVH0086-96 4TVH0115-155
row installation
dB (A) Service
60 60
60 • Easy maintenance with the self diagnostic
function and test switch
59.5
59 • Flexible start up procedure and automated
58.5 piping / wiring checks
58
58 • Self-addressing of indoor units
57.5
57 57 • Optional service software
57
56.5
56
55.5
4TVH0086 4TVH0096 4TVH0115 4TVH0140 4TVH0155
14 VRF-SLB005-EN
Outdoor Units - 4TVH
<K> 4TVH0086BK0 4TVH0096BK0 4TVH0115BK0 4TVH0140BK0 4TVH0155BK0
Model Numbers <D> 4TVH0086BD0 4TVH0096BD0 4TVH0115BD0 4TVH0140BD0 4TVH0155BD0
<6> 4TVH0086B60 4TVH0096B60 4TVH0115B60 4TVH0140B60 4TVH0155B60
kW 25.2 28 33.5 40 45
Capacity
Btu/h 86,000 95,500 114,300 136,500 153,500
Cooling Power Input W 5874 7198 9054 12307 14019
Capacity Range (50% - 130%) MBh 43 - 112 48 - 124 58 - 150 69 - 177 78 - 202
EER W/W 4.29 3.89 3.7 3.25 3.21
kW 27 31.5 37.5 45 50
Capacity
Btu/h 92,100 107,500 128,000 153,500 170,600
Heating Power Input W 6150 7608 8992 11194 12788
Capacity Range (50% - 130%) MBh 46 - 120 54 - 139 64 - 166 77 - 200 85 - 222
COP W/W 4.39 4.14 4.17 4.02 3.91
Cooling Operation Range C -5 C ~ 48 C
Heating Operating Range C -20 C ~ 21 C
Air Flow m3/h 11700 11700 15600 15600 15600
Sound Pressure dB(A) 57 57 58 60 60
Fin Type Hydrophilic Aluminium
Dimensions (W/H/D) mm 960/1615/765 960/1615/765 1250/1615/765 1250/1615/765 1250/1615/765
Net Weight kg 245 245 275 325 325
Refrigerant R410A
Refrigerant Charge kg 10 10 12 15 15
Refrigerant Oil ml FVC68D / 500 ml
Liquid Side mm 12.7 12.7 12.7 15.9 15.9
Gas Side mm 25.4 25.4 25.4 31.8 31.8
Oil Balance Pipe mm 6.4 6.4 6.4 6.4 6.4
Refrigerant Piping
Max. Equivalent Pipe Length m 175
Max. Height difference between IUs m 15
Max. Height difference for OU above IU m 70
Max. Amount of IUs connected to OU 13 16 16 16 20
Optional Accessories
• TVR™ II Outdoor unit centralized controller
TCONTCCM02A
• Digital Ampere Meter
180kW unit
TCONTCCM02A
15 VRF-SLB005-EN
TVR™ II Modular Heat Recovery Outdoor Units
• Choice of 2 power supplies:
50 Hz 380-415 V
60 Hz 220 V
• High Efficiency
• All TVR II Heat Recovery units have the same height and depth allowing
for row installation 4TVR0086 - 4TVR0096
50 & 60 Hz
16 VRF-SLB005-EN
Heat Recovery Outdoor Units - 4TVR
<6> 4TVR0086B60 4TVR0096B60 4TVR0172B60 4TVR0182B60 4TVR0192B60
Model Numbers
<D> 4TVR0086BD0 4TVR0096BD0 4TVR0172BD0 4TVR0182BD0 4TVR0192BD0
kW 25.2 28 50.4 53.2 56
Capacity
Btu/h 86,000 95,600 172,000 181,600 191,200
Cooling Power Input W 5874 7198 12000 13300 14700
Capacity Range (50% - 130%) MBh 43 - 112 48 - 124 86 - 223 91 - 236 96 - 248
EER W/W 4.29 3.89 4.2 4 3.81
kW 27 31.5 54 58.5 63
Capacity
Btu/h 92,200 107,500 184,400 199,700 215,000
Heating Power Input W 6150 7608 12600 14300 158000
Capacity Range (50% - 130%) MBh 46 - 120 54 - 140 92 - 239 100 - 259 108 - 279
COP W/W 4.39 4.14 4.29 4.09 3.98
Cooling Operation Range C -5 C ~ 48 C
Heating Operating Range C -15 C ~ 24 C
Mix Mode Operating Range C -5 C ~ 30 C
Air Flow m3/h 11000 11000 22000 22000 22000
Sound Pressure dB(A) 57 57 60 61 62
Fin Type Hydrophilic aluminum
Dimensions (W/H/D) mm 960/1615/ 765 960/1615/ 765 (960+960)/1615/765 (960+960)/1615/765 (960+960)/1615/765
Net Weight kg 245 245 245*2 245*2 245*2
Refrigerant R410A
Refrigerant Charge kg 10 10 20 20 20
Refrigerant Oil ml FVC68D / 500 ml
Liquid Side mm 12.7 12.7 15.9 15.9 15.9
Gas Side mm 25.4/ 19.1 25.4/ 19.1 28.6/ 22.2 31.8/ 28.6 31.8/ 28.6
Oil Balance Pipe mm 6.4
Refrigerant Piping
Max. Equivalent Pipe Length m 175
Max. Height difference between IUs m 15
Max. Height difference for OU above IU m 50
Max. Amount of IUs connected to OU 7 9 15 16 18
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1m in front of the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
17 VRF-SLB005-EN
TVR™ II Individual Heat Pump Outdoor Units
• Choice of 2 power supplies:
50 Hz 380-415 V
60 Hz 380-415 V
Sound Pressure at 1m
Comfort
64
• Auto-restart function
64
• Wide range of indoor units
63.5
63 63
63 Service
62.5 • Easy maintenance with self-diagnostic
62 function and test switch
61.5
• Self-addressing of indoor units
61
• Optional service software
60.5
60
59.5
4TVH0180 4TVH0190 4TVH0290
18 VRF-SLB005-EN
Individual Outdoor Units - 4TVH
<K> 4TVH0180BK0 4TVH0190BK0
Model Numbers
<D> 4TVH0180BD0 4TVH0190BD0 4TVH0290BD0
kW 53 56 85
Capacity
Btu/h 180,800 191,100 290,000
Cooling Power Input W 16000 17000 36000
Capacity Range (50% - 130%) MBh 90-235 96-248 145-377
EER W/W 3.31 3.3 2.36
kW 59 63 95
Capacity
Btu/h 199,600 215,000 324,100
Heating Power Input W 14900 16000 31500
Capacity Range (50% - 130%) MBh 100-260 108-280 162-421
COP W/W 3.96 3.94 3.02
Cooling Operation Range C -5 C ~ 48 C
Heating Operating Range C -20 C ~ 21 C
Air Flow m3/h 23000 23000 27900
Sound Pressure dB(A) 63 63 64
Fin Type Hydrophilic aluminum
Dimensions (W/H/D) mm 1960/1615/765 1960/1615/765 2540/1615/765
Net Weight kg 460 460 655
Refrigerant R410A
Refrigerant Charge kg 18 18 21
Refrigerant Oil ml FVC68D / 500
Liquid Side mm 15.9 15.9 22
Gas Side mm 31.8 31.8 38
Oil Balance Pipe mm / / 60
Refrigerant Piping
Max. Equivalent Pipe Length m 175
Max. Height difference between IUs m 15
Max. Height difference for OU above IU m 70
Max. Amount of IUs connected to OU 20 24 32
Optional Accessories
• TVR™ II Outdoor unit centralized controller
TCONTCCM02A
• Digital Ampere Meter
TCONTCCM02A
19 VRF-SLB005-EN
Indoor Units
20 VRF-SLB005-EN
4-Way Cassette - 60 Hz
Model Numbers 4TVC0009B10 4TVC0012B10 4TVC0015B10 4TVC0018B10 4TVC0024B10 4TVC0027B10 4TVC0030B10 4TVC0034B10 4TVC0038B10 4TVC0048B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
kW 2.8 3.2 4.5 5.6 7.1 8 9 10 11.2 14
Cooling
Btu/h 9,600 12,300 6 19,100 24,200 27,300 30,700 34,100 38,200 47,800
Capacity
kW 3.2 4 5 6.3 8 9 10 11 12.5 15
Heating
Btu/h 10,900 13,600 17,100 21,500 27,300 30,700 34,100 37,500 42,700 51,200
Power Input W 60 60 71 71 94 94 173 173 173 186
Rated Current A 0.4 0.4 0.4 0.4 0.5 0.5 0.7 0.7 0.7 0.8
1590/1300 1590/1300 1590/1300 1678/1358
Air Flow (H/M/L) m3/h 847/766/640 847/766/640 864/755/658 864/755/658 1157/955/749 1236/973/729
/1090 /1090 /1090 /1115
Sound Pressure (H/M/L) dB(A) 42/38/35 42/38/35 42/38/35 42/38/35 45/42/39 45/42/39 48/45/43 48/45/43 48/45/43 50/47/44
Dimensions mm 840/230/840 840/230/840 840/230/840 840/230/840 840/230/840 840/230/840 840/300/840 840/300/840 840/300/840 840/300/840
Unit (W/H/D)
Net Weight kg 24 24 26 26 26 26 32 32 32 32
Dimensions mm 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950
(W/H/D)
Front Panel Model RAYPANELWHT001
Number
Net Weight kg 6 6 6 6 6 6 6 6 6 6
Refrigerant Liquid Side mm 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Piping Gas Side mm 12.7 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32 32 32 32 32
4-Way Cassette - 50 Hz
Model Numbers 4TVC0009BB0 4TVC0012BB0 4TVC0015BB0 4TVC0018BB0 4TVC0024BB0 4TVC0027BB0 4TVC0030BB0 4TVC0034BB0 4TVC0038BB0 4TVC0048BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
kW 2.8 3.2 4.5 5.6 7.1 8 9 10 11.2 14
Cooling
Btu/h 9,600 12,300 6 19,100 24,200 27,300 30,700 34,100 38,200 47,800
Capacity
kW 3.2 4 5 6.3 8 9 10 11 12.5 15
Heating
Btu/h 10,900 13,600 17,100 21,500 27,300 30,700 34,100 37,500 42,700 51,200
Power Input W 80 80 90 75 82 97 160 160 160 170
Rated Current A 0.4 0.4 0.4 0.4 0.5 0.5 0.7 0.7 0.7 0.8
1540/1300 1540/1300 1540/1300 1800/1500
Air Flow (H/M/L) m3/h 847/766/640 847/766/640 864/755/658 864/755/658 1157/955/749 1236/973/729
/1120 /1120 /1120 /1280
Sound Pressure (H/M/L) dB(A) 42/38/35 42/38/35 42/38/35 42/38/35 45/42/39 45/42/39 48/45/43 48/45/43 48/45/43 50/47/44
Dimensions mm 840/230/840 840/230/840 840/230/840 840/230/840 840/230/840 840/230/840 840/300/840 840/300/840 840/300/840 840/300/840
Unit (W/H/D)
Net Weight kg 24 24 26 26 26 26 32 32 32 32
Dimensions mm 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950
(W/H/D)
Front Panel Model RAYPANELWHT001
Number
Net Weight kg 6 6 6 6 6 6 6 6 6 6
Refrigerant Liquid Side mm 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Piping Gas Side mm 12.7 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32 32 32 32 32
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
21 VRF-SLB002-EN
21 VRF-SLB005-EN
Compact 4-way Cassette -
4TVB
Comfort
• 360° efficient air distribution Quick installation
• Three level fan speed that meets different air • Ultra thin body of 265mm for installation in
supply requirements tight ceilings
• Optimum air flow thanks to the 3-Dimensional • Light weight units are easy to mount
Screw fan • Integrated drain pump that lifts up to
3-Dimensional
Screw Fan - Reduced Air resistance 500mm
630 mm
Compact
Cassette Panel
265 mm
22 VRF-SLB005-EN
Compact 4-Way Cassette – 60 Hz
Model Numbers 4TVB0007B10 4TVB0009B10 4TVB0012B10 4TVB0015B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
kW 2.2 2.8 3.6 4.5
Cooling
Btu/h 7,500 9,600 12,300 15,400
Capacity
kW 2.4 3.2 4 5
Heating
Btu/h 8,200 10,900 13,600 17,100
Power Input W 51 52 58 58
Rated Current A 0.175 0.175 0.21 0.21
Air Flow (H/M/L) m3/h 532/397/292 539/408/310 632/496/359 632/496/359
Sound Pressure dB(A) 38.1/33.4/23.4 38.1/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8
Dimensions (W/H/D) mm 630/265/570 630/265/570 630/265/570 630/265/570
Unit
Net Weight kg 17.5 17.5 19 19
Dimensions (W/H/D) mm 647/50/647 647/50/647 647/50/647 647/50/647
Front Panel Model Number RAYCMPCTPNL002
Net Weight kg 3 3 3 3
Liquid Side mm 6.35 6.35 6.35 6.35
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7
Drainage Water Pipe (OD) mm 25 25 25 25
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
23 VRF-SLB005-EN
2-Way Cassette - 4TVG
Flexibility
• Compact design Comfort
• Standard built-in drain pump (750 mm) • Low sound level (24 dB (A) on 7 MBH unit)
• One panel size for all models (from 7 to 24 MBH) • Efficient air distribution
• Standard filter
24 VRF-SLB005-EN
2-Way Cassette – 60 Hz
Model Numbers 4TVG0007B10 4TVG0009B10 4TVG0012B10 4TVG0015B10 4TVG0018B10 4TVG0024B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
kW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Capacity
kW 2.6 3.2 4 5 6.3 8
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300
Power Input W 57 57 60 92 108 154
Rated Current A 0.35 0.45 0.45 0.55 0.55 0.75
Air Flow (H/M/L) m3/h 674/509/381 674/509/381 740/577/435 878/689/561 941/776/654 1236/1110/864
Sound Pressure dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34
Dimensions (W/H/D) mm 1172/300/592 1172/300/592 1172/300/592 1172/300/592 1172/300/592 1172/300/592
Unit
Net Weight kg 34 34 34 36.5 36.5 36.5
Dimensions (W/H/D) mm 1430/53/680 1430/53/680 1430/53/680 1430/53/680 1430/53/680 1430/53/680
Front Panel Model Number RAYTWOWAYPNL01
Net Weight kg 10.5 10.5 10.5 10.5 10.5 10.5
Liquid Side mm 6.35 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32
2-Way Cassette – 50 Hz
Model Numbers 4TVG0007BB0 4TVG0009BB0 4TVG0012BB0 4TVG0015BB0 4TVG0018BB0 4TVG0024BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
kW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Capacity
kW 2.6 3.2 4 5 6.3 8
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300
Power Input W 57 57 60 92 108 154
Rated Current A 0.35 0.45 0.45 0.55 0.55 0.75
Air Flow (H/M/L) m3/h 654/530/410 654/530/410 725/591/458 850/670/550 980/800/670 1200/1000/770
Sound Pressure dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34
Dimensions (W/H/D) mm 1172/300/592 1172/300/592 1172/300/592 1172/300/592 1172/300/592 1172/300/592
Unit
Net weight kg 34 34 34 36.5 36.5 36.5
Dimensions (W/H/D) mm 1430/53/680 1430/53/680 1430/53/680 1430/53/680 1430/53/680 1430/53/680
Front Panel Model Number RAYTWOWAYPNL01
Net Weight kg 10.5 10.5 10.5 10.5 10.5 10.5
Liquid Side mm 6.35 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
25 VRF-SLB005-EN
1-Way Cassette - 4TVE
Flexibility
• Compact design
Comfort
• Standard built-in drain pump (750 mm) • Low sound level (24 dB (A) on 7 MBH unit)
• Two front panels • Efficient air distribution
– RAYONEWAYPNL01 (9 to 12 MBH) • Built-in Auto-restart
– RAYONEWAYPNL02 (15 to 24 MBH) • Standard filter
26 VRF-SLB005-EN
1-Way Cassette – 60 Hz
Model Numbers 4TVE0009B10 4TVE0012B10 4TVE0015B10 4TVE0018B10 4TVE0024B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
kW 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 9,600 12,300 15,400 19,100 24,200
Capacity
kW 3.2 4 5 6.3 8
Heating
Btu/h 10,900 13,600 17,100 21,500 27,300
Power Input W 53 53 86 86 86
Rated Current A 0.4 0.4 0.4 0.4 0.5
Air Flow (H/M/L) m3/h 500/450/410 500/450/410 894/800/750 919/850/760 1080/980/900
Sound Pressure dB(A) 36/34/30 36/34/30 41/38/35 41/38/35 41/38/35
Dimensions (W/H/D) mm 850/400/235 850/400/235 1200/198/655 1200/198/655 1200/198/655
Unit
Net Weight kg 23 23 31 31 31
Dimensions (W/H/D) mm 1050/18/470 1050/18/470 1420/10/755 1420/10/755 1420/10/755
Front Panel Model Number RAYONEWAYPNL01 RAYONEWAYPNL02
Net Weight kg 4 4 9 9 9
Liquid Side mm 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 15.9 15.9 15.9 15.9 15.9
1-Way Cassette – 50 Hz
Model Numbers 4TVE0009BB0 4TVE0012BB0 4TVE0015BB0 4TVE0018BB0 4TVE0024BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
kW 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 9,600 12,300 15,400 19,100 24,200
Capacity
kW 3.2 4 5 6.3 8
Heating
Btu/h 10,900 13,600 17,100 21,500 27,300
Power Input W 53 53 86 86 86
Rated Current A 0.3 0.3 0.4 0.4 0.45
Air Flow (H/M/L) m3/h 500/450/410 500/450/410 894/800/750 919/850/760 1080/980/900
Sound Pressure dB(A) 36/34/30 36/34/30 41/38/35 41/38/35 41/38/35
Dimensions (W/H/D) mm 850/400/235 850/400/235 1200/198/655 1200/198/655 1200/198/655
Unit
Net Weight kg 23 23 31 31 31
Dimensions (W/H/D) mm 1050/18/470 1050/18/470 1420/10/755 1420/10/755 1420/10/755
Front Panel Model Number RAYONEWAYPNL01 RAYONEWAYPNL02
Net weight kg 4 4 9 9 9
Liquid Side mm 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 15.9 15.9 15.9 15.9 15.9
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
27 VRF-SLB005-EN
Low ESP Ducted Indoor
Unit - 4TVL
Comfort
Quick installation
• Efficient air distribution
• Ultra thin body of 190mm for both
• Three level fan speed that meets different air 50 & 60 Hz models
supply requirements for installation in small false ceilings
• Very low noise level - 21 dB (A) for • Light weight units are easy to mount
7 MBH unit
Flexibility
• Built in Auto Restart • Standard EXV mounted at the factory
horizontally
28 VRF-SLB005-EN
Low Pressure Duct – 60 Hz
Model Numbers 4TVL0007B10 4TVL0009B10 4TVL0012B10 4TVL0015B10 4TVL0018B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
KW 2.2 2.8 3.6 4.5 5.6
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100
Capacity
KW 2.6 3.2 4 5 6.3
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500
Power Input W 32 35 35 43 43
Rated Current A 0.17 0.17 0.17 0.17 0.24
Air Flow (H/M/L) m3/h 452/409/310 521/460/372 521/460/372 831/712/591 831/712/591
Indoor External Static Pressure (H) Pa 5
Sound Pressure (H/M/L) dB(A) 34/29/21 36/34/30 36/34/30 37/35/31 37/35/31
Dimensions (W/H/D) mm 850/190/405 850/190/405 850/190/405 1030/190/430 1030/190/430
Net Weight kg 11.5 11.5 11.5 14 14
Liquid Side mm 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 20
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
29 VRF-SLB005-EN
Medium ESP Ducted
Indoor - 4TVD
Comfort Quick installation
• Three level fan speed that meets different air • Ultra thin body of 210mm height for
supply requirements installation in small ceiling pocket
• Low noise level thanks to the fan blade design • Light weight units are easy to mount
• Built in Auto Restart Flexibility
• Standard long life filter • Different installations patterns possible with
bottom return or ducted return
30 VRF-SLB005-EN
Mid Pressure Duct – 60 Hz
Model Numbers 4TVD0007B10 4TVD0009B10 4TVD0012B10 4TVD0015B10 4TVD0018B10 4TVD0024B10 4TVD0027B10 4TVD0030B10 4TVD0038B10 4TVD0048B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
kW 2.2 2.8 3.2 4.5 5.6 7.1 8 9 11.2 14
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 27,300 30,700 38,200 47,800
Capacity
kW 2.6 3.2 4 5 6.3 8 9 10 12.5 15.5
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300 30,700 34,100 42,650 52,900
Power Input W 66 72 77 101 100 125 133 134 378 352
Rated Current A 0.28 0.28 0.28 0.5 0.5 0.7 1.16 1.16 1.65 1.8
Air Flow (H/M/L) m3/h 476/399/335 476/399/335 534/452/391 746/558/470 750/563/470 998/820/607 1226/1018/861 1230/1019/859 1750/1552/1389 1789/1539/1250
Indoor External Static Pa 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30) 20(10~50) 20(10~50) 40(10~80) 40(10~100)
Pressure (H)
Sound Pressure (H/M/L) dB(A) 38/35/32 38/35/32 40/38/36 41/38.9/36 41/38.9/36 42/40/35 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0
Dimensions (W/H/D) mm 700/210/635 700/210/635 700/210/635 920/210/635 920/210/635 1140/210/635 1140/270/775 1140/270/775 1140/270/775 1200/300/865
Net weight kg 21.5 21.5 22 27 27 31.8 38 40 40 49
Liquid mm 6.35 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Refrigerant Side
Piping Gas mm 12.7 12.7 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9
Side
Drainage Water Pipe (OD) mm 32 32 32 32 32 32 32 32 32 32
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
31 VRF-SLB002-EN
31 VRF-SLB005-EN
High ESP Ducted
Indoor - 4TVA
Comfort
• Three level fan speed that meets different air
supply requirements
Flexibility
• Broad range of models up to 95 MBH in 50 Hz
and 55 MBH in 60 Hz
• External Static Pressure up to 196 Pa
32 VRF-SLB005-EN
High Pressure Duct – 60Hz
Model Numbers 4TVA0024B10 4TVA0027B10 4TVA0030B10 4TVA0038B10 4TVA0048B10 4TVA0055B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
KW 7.1 8 9 11.2 14 16
Cooling
Btu/h 24,200 27,300 30,700 38,200 47,800 54,600
Capacity
KW 8 9 10 12.5 16 18
Heating
Btu/h 27,300 30,700 34,100 42,650 54,600 61,400
Power Input W 414 402 409 524 627 832
Rated Current A 1.1 1.1 1.8 2.3 2.7 3.6
Air Flow (H/M/L) m3/h 1758/1568/1342 1602/1494/1302 2250/2020/1595 2250/2020/1595 3030/2711/2490 3030/2711/2490
Indoor External Static Pressure (H) Pa 40(30~ 196) 40(30~ 196) 40(30~ 196) 50(30~ 196) 50(30~ 196) 50(30~ 196)
Sound Pressure (H/M/L) dB(A) 48/46/44.5 48/46/44.5 52/49/47 52/49/47 53/50/48 54/52/50
Dimensions (W/H/D) mm 952/420/690 952/420/690 952/420/690 952/420/690 1200/400/600 1200/400/600
Net Weight kg 46.5 46.5 50 50.6 70 70
Liquid Side mm 9.52 9.52 9.52 9.52 9.52 9.52
Refrigerant Piping
Gas Side mm 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
33 VRF-SLB005-EN
Convertible - 4 TVX
Comfort
• Efficient air distribution with two directional
airflow and wide angle air flow
• Three level fan speed that meets different air
supply requirements
• Low noise level
• Built in Auto Restart
Quick installation
• Ultra thin body of 206mm and 660mm height
for installation under windows or ceilings
Flexibility
• Light weight units are easy to mount
• Modern and elegant appearance
• Drain pipe connection left or right
• Can be installed vertically and horizontally
34 VRF-SLB005-EN
Convertible – 60 Hz
Model Numbers 4TVX0012B10 4TVX0015B10 4TVX0018B10 4TVX0024B10 4TVX0030B10 4TVX0038B10 4TVX0048B10 4TVX0055B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
KW 3.6 4.5 5.6 7.1 8 9 11.2 14
Cooling
Btu/h 12,300 15,400 19,100 24,200 27,300 30,700 38,200 47,800
Capacity
KW 4 5 6.3 8 9 10 12.5 15.5
Heating
Btu/h 13,600 17,100 21,500 27,300 30,700 34,100 42,650 52,900
Power Input W 49 147 147 147 185 185 241 241
Rated Current A 0.55 0.55 0.55 0.57 0.6 0.6 0.83 0.83
Air Flow (H/M/L) m3/h 600/ 480/ 400 750/650/550 750/650/550 750/650/550 1200/900/700 1200/900/700 1980/1860/1730 1980/1860/1730
Sound Pressure (H/M/L) dB(A) 40/38/36 43/41/38 43/41/38 43/41/38 45/43/40 45/43/40 47/45/42 47/45/42
Dimensions (W/H/D) mm 990/660/206 990/660/206 990/660/206 990/660/206 1280/660/206 1280/660/206 1670x680x244 1670x680x244
Net Weight kg 26 28 28 28 34.5 34.5 54 54
Refrigerant Liquid Side mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Piping Gas Side mm 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water
mm 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Pipe (OD)
Convertible – 50 Hz
Model Numbers 4TVX0012BB0 4TVX0015BB0 4TVX0018BB0 4TVX0024BB0 4TVX0030BB0 4TVX0038BB0 4TVX0048BB0 4TVX0055BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 3.6 4.5 5.6 7.1 8 9 11.2 14
Cooling
Btu/h 12,300 15,400 19,100 24,200 27,300 30,700 38,200 47,800
Capacity
KW 4 5 6.3 8 9 10 12.5 15.5
Heating
Btu/h 13,600 17,100 21,500 27,300 30,700 34,100 42,650 52,900
Power Input W 49 120 122 125 130 130 182 182
Rated Current A 0.55 0.55 0.55 0.57 0.6 0.6 0.83 0.83
Air Flow (H/M/L) m3/h 650/570/500 800/600/500 800/600/500 800/600/500 1200/900/700 1200/900/700 1980/1860/1730 1980/1860/1730
Sound Pressure (H/M/L) dB(A) 40/38/36 43/41/38 43/41/38 43/41/38 45/43/40 45/43/40 47/45/42 47/45/42
Dimensions (W/H/D) mm 990/660/206 990/660/206 990/660/206 990/660/206 1280/660/206 1280/660/206 1670/680/244 1670/680/244
Net Weight kg 26 28 28 28 34.5 34.5 54 54
Refrigerant Liquid Side mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Piping Gas Side mm 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water
mm 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Pipe (OD)
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located at a distance of 1 m (horizontal) and 1 m (vertical) from the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
35 VRF-SLB002-EN
35 VRF-SLB005-EN
7 to 18 MBH
Wall Mounted Indoor Unit
- 4TVW
Comfort
• Double air guides for optimum air distribution
Quick Installation
• LED display integrated, allows trouble
Flexibility
shooting
• Slim design with an easy to clean mirror
• Multi position piping possibilities (7 to 18 MBH)
36 VRF-SLB005-EN
High Walls – 60 Hz
Model Numbers 4TVW0007B10 4TVW0009B10 4TVW0012B10 4TVW0015B10 4TVW0018B10 4TVW0024B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
KW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,232
Capacity
KW 2.6 3.2 4 5 6.3 8
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,304
Power Input W 28 28 28 45 45 79
Rated Current A 0.14 0.14 0.14 0.2 0.2 0.33
Air Flow (H/M/L) m3/h 557/520/467 557/520/467 557/520/467 842/722/597 842/722/597 1190/880/680
Sound Pressure (H/M/L) dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 47
Dimensions (W/H/D) mm 915/290/210 915/290/210 915/290/210 1070/315/210 1070/315/210 1250/325/230
Net Weight kg 12 12 12 16 16 19.9
Liquid Side mm 6.35 6.35 6.35 6.35 9.52 9.5
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 16.5 16.5 16.5 16.5 16.5 16.5
High Walls – 50 Hz
Model Numbers 4TVW0007BB0 4TVW0009BB0 4TVW0012BB0 4TVW0015BB0 4TVW0018BB0 4TVW0024BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,232
Capacity
KW 2.6 3.2 4 5 6.3 8
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,304
Power Input W 28 28 28 45 45 79
Rated Current A 0.14 0.14 0.14 0.2 0.2 0.33
Air Flow (H/M/L) m3/h 520/480/430 520/480/430 520/480/430 860/755/630 925/860/755 1190/880/680
Sound Pressure (H/M/L) dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 47
Dimensions (W/H/D) mm 915/290/210 915/290/210 915/290/210 1070/315/210 1070/315/210 1250/325/230
Net Weight kg 12 12 12 16 16 19.9
Liquid Side mm 6.35 6.35 6.35 6.35 9.52 9.5
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 16.5 16.5 16.5 16.5 16.5 16.5
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located at a distance of 1m (horizontal) and 1 m (vertical) from the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
Note: Specifications subject to change without notice.
37 VRF-SLB002-EN
37 VRF-SLB005-EN
Console Type - 4TVJ
Flexibility
• Compact design
• Built-in EXV
Comfort
• Low sound level
• Built-in Auto-restart
• Standard filter
COOLING MODE
COOLING MODE HEATING MODE
HEATING MODE
38 VRF-SLB005-EN
Console – 60 Hz
Model Numbers 4TVJ0007B10 4TVJ0009B10 4TVJ0012B10 4TVJ0015B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
KW 2.2 2.8 3.6 4.5
Cooling
Btu/h 7,500 9,600 12,300 15,400
Capacity
KW 2.6 3.2 4 5
Heating
Btu/h 8,900 10,900 13,600 17,100
Power Input W 20 25 25 45
Rated Current A 0.09 0.11 0.11 0.2
Air Flow (H/M/L) m3/h 430/345/229 510/430/229 510/430/229 510/430/229
Sound Pressure (H/M/L) dB(A) 38/32/26 39/33/27 39/33/27 42/39/36
Dimensions (W/H/D) mm 700/600/210 700/600/210 700/600/210 700/600/210
Unit
Net Weight kg 14 15 15 15
Liquid Side mm 6.35 6.35 6.35 6.35
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7
Drainage Water Pipe (OD) mm 16 16 16 16
Console – 50 Hz
Model Numbers 4TVJ0007BB0 4TVJ0009BB0 4TVJ0012BB0 4TVJ0015BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 2.2 2.8 3.6 4.5
Cooling
Btu/h 7,500 9,600 12,300 15,400
Capacity
KW 2.6 3.2 4 5
Heating
Btu/h 8,900 10,900 13,600 17,100
Power Input W 20 25 25 45
Rated Current A 0.09 0.11 0.11 0.2
Air Flow (H/M/L) m3/h 430/345/229 510/430/229 510/430/229 510/430/229
Sound Pressure (H/M/L) dB(A) 38/32/26 39/33/27 39/33/27 42/39/36
Dimensions (W/H/D) mm 700/600/210 700/600/210 700/600/210 700/600/210
Unit
Net Weight kg 14 15 15 15
Liquid Side mm 6.35 6.35 6.35 6.35
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7
Drainage Water Pipe (OD) mm 16 16 16 16
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
39 VRF-SLB005-EN
Intelligent Management Control System
The TVR™ II system can be controlled on different user levels, from the individual user level with the zone controllers to a more
centralized tenant by tenant control or a fully integrated building control PC system with a third party BMS control system
Individual Controllers
Wireless Controller TCONTRM05B Wireless Controller TCONTRM02A
(for HP systems) (for HR systems)
• Functions: LCD display, Clock, ON/ • Auto-changeover mode for HR
OFF, Temp. setting, Mode setting, systems
Fan speed setting, Timer, Horizontal • Functions: LCD display, Clock,
Swing, Vertical Swing, Air Direction ON/OFF, Temp. setting, Mode
• Mode: Auto/Dry/Cool/Heat & Fan only setting, Fan speed setting, Timer
• Timer: 0 – 24 hrs timer setting • Addressing function TCONTRM02A
40 VRF-SLB005-EN
Centralized Controllers Outdoor Unit Centralized
Controller TCONTCCM02A
Indoor unit Centralized Controllers
• Controls 32 outdoor units and
• TCONTCCM09A (for HP systems)
a PC can control 16 OU centralized
TCONTCCM09A
• TCONTCCM03HP (for HP systems) controllers
41 VRF-SLB005-EN
Building Management Control
The TVR™ II control network can combine several centralized controllers with a PC or external BMS systems such as Tracer SC
through BACnet™ or MODBUS interfaces to meet customers’ needs in different applications. This higher level of control adds
more user friendly features such as power consumption reporting.
Outdoor Units
F1,F2,E K1,K2,E
TCONTCCM08A Indoor Units
MAX 4
TCONTCCM02A or TCONTCCM03 TCONTCCM02A
TCONTCCM03HP
Outdoor Units
BACnet/IP protocol
X,Y,E
TCONTCCM03HP
Indoor Units
42 VRF-SLB005-EN
BACnet® Interface TCONTCCM08A Digital Ampmeter TCONTDTS
• This gateway connects through BACnet® • One Amp meter per Master Outdoor Unit or
to the TVR™ II entire installation and other condensing system
external components through an existing
• Needs to be connected to specific wiring
BMS
terminals on outdoor unit
• Connects through Ethernet to BACnet®/IP
• Outdoor Units TVR II need
TCONTCCM08A
• 4 RS485 connections for connecting to 4 to have a controller TCONTCCM02A that
TVR II centralized controllers connects to PC or network.
TCONTMODBUS
43 VRF-SLB005-EN
New Service Software
As part of our new TVR™ II portfolio, we
introduce a new service tool that allows you to
diagnose and troubleshoot the system.
• Model number: TCONTSERVS. 485A-l
K1,K2,E
• Real time display of outdoor unit
operating parameters
• Description of error codes.
Other Accessories
TCONTAHUKIT1 TCONTNAM05A
TCONTNAM09A
Trane also offers other accessories to maximize customers’ comfort in different applications.
44 VRF-SLB005-EN
TVR™ II Outside Air Solutions
Indoor air quality depends on many design
factors and local codes.
Heat Ex-
"Sound Level dB(A) 27 30 32 35 39 40 51 53
change Mode
(Hi Speed)"
Bypass Mode dB(A) 28 31 33 36 40 41 52 54
Dimensions (W/H/D) mm 866/655/264 944/722/270 944/927/270 1038/1026/270 1286/1006/388 1286/1256/388 1600/1270/540 1650/1470/540
Weight kg 23 26 31 41 62 79 163 182
Notes:
• TERV0120 to TERV0600 have three speeds, while models TERV0900 to TERV1200 have one speed
• Sound level measured at 1.4m in an anechoic room
• Temp. Exchange Efficiency is the average of cooling and heating values
45 VRF-SLB005-EN
100% Fresh Air - 4TVF
Flexibility
• External static pressure up to 260 Pa
Comfort
• Both fresh air filtration and heating or cooling
achieved with the same unit.
• Standard filter
Layout Example:
Outdoor Units
46 VRF-SLB005-EN
Fresh Air Units – 60 Hz
Model Numbers 4TVD0042B10 4TVD0048B10 4TVD0068B10 4TVD0085B10 4TVD0095B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
KW 12.5 14 20 25 28
Cooling
Btu/h 42,650 47,800 68,250 85,300 95,600
Capacity
KW 10.5 12 18 20 22
Heating
Btu/h 35,800 40,950 61,400 68,250 75,000
Power Input W 461 461 1063 1063 1063
Rated Current A 2.3 2.3 5.3 5.3 5.3
Air Flow (H/M/L) m3/h 1568/1452/1352 1568/1452/1352 4429/3884/3332 4560/4083/3563 4939/4405/3859
Indoor External Static Pressure (H) 50(30~ 196) 50(30~ 196) 140(50~260) 140(50~260) 160(50~260)
Sound Pressure (H/M/L) dB(A) 54/52/50 54/52/50 54/53/51 55/54/52 55/54/52
Dimensions (W/H/D) mm 1368/420/691 1368/420/691 1443/470/810 1443/470/810 1443/470/810
Net Weight kg 69.5 69.5 115 115 115
Liquid Side mm 9.52 9.52 9.52 9.52 9.52
Refrigerant Piping
Gas Side mm 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 25 25 32 32 32
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.
47 VRF-SLB005-EN
Ingersoll Rand (NYSE:IR) is a world leader in creating and sustaining safe, comfortable and efficient environments in commercial, residential and
industrial markets. Our people and our family of brands—including Club Car®, Ingersoll Rand®, Schlage®, Thermo King® and Trane®—work together to
enhance the quality and comfort of air in homes and buildings, transport and protect food and perishables, secure homes and commercial properties,
and increase industrial productivity and efficiency. We are a $14 billion global business committed to sustainable business practices within our
company and for our customers. For more information, visit www.ingersollrand.com.
© 2012 Trane All rights reserved We are committed to using environmentally trane.com
VRF-SLB005-EN September 25, 2012 conscious print practices that reduce waste. ingersollrand.com