High-Efficiency CMRV Air Conditioning System

The document describes the Multi-Comfort CMRV air conditioning and heating system. It has a variable capacity compressor and digital scroll compressor that can adjust output from 10-100%. It offers individual temperature control and monitoring for each room. The outdoor units have a capacity of 50,000 or 100,000 BTUs and can be connected in parallel for up to 300,000 BTUs total. Indoor units include wall mounts, cassettes, and ducted options each with variable capacity.

Uploaded by

Fernando
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views4 pages

High-Efficiency CMRV Air Conditioning System

The document describes the Multi-Comfort CMRV air conditioning and heating system. It has a variable capacity compressor and digital scroll compressor that can adjust output from 10-100%. It offers individual temperature control and monitoring for each room. The outdoor units have a capacity of 50,000 or 100,000 BTUs and can be connected in parallel for up to 300,000 BTUs total. Indoor units include wall mounts, cassettes, and ducted options each with variable capacity.

Uploaded by

Fernando
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Multi-Comfort

CMRV
Series

A I R C O N D I T I O N I N G A N D H E AT I N G
A significantly improved
version of traditional
Central Air Conditioner
The CMRV air conditioning system operates
with a high efficiency Digital Scroll Compressor
featuring PWM Valve for adjusting compressor
output in the range of 10%-100%.
The two different outdoor models are offered:
a 50,000 Btu/h unit with up to 8 indoor units;
or a 100,000 Btu/h unit with up to 16 indoor units.
Taking advantage of the modular multi technology,
3 CMRV outdoor units can parallel connected
to expand the maximum capacity up to
300,000 Btu/h.

-OR-

The indoor units can be any mixture of wall mounts, cassettes or concealed
ducted. Each indoor unit has an electronic expansion value that enables the
indoor units to operate with variable capacity.
Applied with the cutting-edge technologies: intelligent cooling quantity
distribution system, temperature control system, powerful self-diagnose program
and long-distance communication circuit, the CMRV is packed with features
and benefits for both the owner and installer to give ease and flexibility
of installation, maintenance, high efficiency, and reliability.
The advantages of a
Compressor
CMRV SYSTEM
over a traditional
central air
PWM
conditioning Valve
system:

1. Variable Compressor
Digital Scroll Compressor and PWM
(Pulse Width Modulation) Valve
automatically controls the cooling/
heating capacity in a range of
10% - 100%.
PWM solenoid valve controls the
separation and reunion of compressor
orbit scroll pan and fixed scroll pan by
reacting to the suction line pressure.
Therefore, the capacity of compressor
is controlled automatically according
to the actual loading status.
Under the circumstance of 10% load,
CMRV system still maintains steady
running and performance.
CMRV system can maintain higher EER
in part load running.

2. Individual Control 4. Efficient Space Utilization 6. Precise Room Temperature Control


CMRV offers maximum comfort and The lightweight and compact outdoor Adopted intelligent cooling quantity
energy saving compared to traditional unit can be transported by a regular distribution system and temperature
central air conditioner, because each elevator and be installed on roof, balcony control system, CMRV maintains the
room is controlled individually. Only or each floor without reinforcement. room temperature within ±1°F of the
those rooms requiring air conditioning Little or no ductwork, two-pipe and setting temperature by continuous
are cooled or heated. two-wire configuration eliminate the adjusting electric expansion valves
huge cumbersome machine system and on every indoor unit.
3. Ultimate Reliability complex pipeline design which save more
The self-diagnostic program identifies indoor space.
problems within the system quickly
and accurately during installation, 5. Easy Installation
commissioning and operation phase. Simple piping and wiring system with
Any problem can be displayed on the light indoor and outdoor unit, requires
control screen or be diagnosed by fewer installation personnel thus the
using a PC or laptop. time and cost are reduced. Adapting full
After installing long-distance monitoring set of quality cooling fittings to eliminate
system, the entire system could be the need for piping calculations, which
monitored in a control room. Every aspect reduce the time and cost needed
of the air conditioner can be controlled, for design.
while the present and history parameter The refrigerant piping between the
can also be checked. indoor unit and outdoor unit can extend
Individual control of each indoor unit up to 410 feet and a maximum vertical
keeps the entire system running height of 160 feet. The length of the
continually without interruption by refrigerant pipe gives more flexibility in
any single malfunction indoor unit. designing and installation.
CMRVseries
7. Low Operation Sound
Comparing to a traditional air handler, Model Power Supply Capacity Noise Outline Dimension (ft)
the users enjoy the much lower sound Outdoor (BTU) Width Depth Height Weight (lb)
level of the indoor unit. The outdoor Units CMRVC-50 3PH, 220-230V, 50,000 60 4.13 1.48 4.17 308
units are also quiet as described on CMRVC-100 60 HZ 100,000 62 3.25 2.76 5.56 660
the right:

8. Flexible and wide selection


of indoor units
The whole capacity of the indoor units a maximum of 16 indoor units. with different types and capacities
could reach 135% of that of the outdoor According to different purposes and can be selected.
unit. One outdoor unit could connect to specifications of every room, indoor units

Indoor Model Power Capacity Noise Outline Dimension (ft) Weight (lb)
Units Supply (BTU) W* D* H
Wall- CMRVC-09W 9000 31 2.72* 0.62* 0.94 24.25
Mounted CMRVC-12W 12000 35 2.72* 0.62* 0.94 24.25
Type CMRVC-17W 17000 46 2.98* 0.64* 0.95 26.46
CMRVC-09D 9000 37 2.48* 2.23* 0.72 59.22
CMRVC-12D 12000 40 2.48* 2.23* 0.72 59.22
Duct Type CMRVC-17D 1PH, 17000 44 2.97* 2.41* 0.87 79.37
CMRVC-24D 220-230V, 24000 46 3.64* 2.48* 0.98 121.3
CMRVC-34D 60 HZ 34000 48 3.68* 2.48* 0.98 165.3
CMRVC-40D 40000 48 3.68* 2.48* 0.98 165.3
CMRVC-17C 17000 45 2.76* 2.76* 0.62 55.12
Cassette CMRVC-24C 24000 47 2.76* 2.76* 0.79 66.14
Type CMRVC-34C 34000 52 2.76* 2.76* 1.05 83.78
CMRVC-40C 40000 52 2.76* 2.76* 1.05 83.78

Unit Selection
Step 1. Indoor unit selection Step 2. Outdoor unit selection
To select the proper indoor unit, it is very procedure, the typical valves can be used Repeat step 1 until all indoor units have
important to perform the load calculation to estimate the indoor unit size. Typical been selected. Calculate the total indoor
in order to determine what size unit your values for cooling loads generally vary from load capacity by adding up all individual
room requires. The major factors that affect 40 Btu/ft2 for buildings in cool climates indoor unit capacity. Select the nearest
the heat gain and loss should be taken with little internal heat gains to 80 Btu/ft2 capacity outdoor unit from our Outdoor
into account, including room size, room or more for buildings in hot climates with Unit Table according to the total indoor
orientation, window type, insulation high internal heat gains. load capacity. The total indoor load
and so on. ASHRAE has established one Select the nearest load capacity indoor unit capacity should be less than 130% of
of the most widely known and accepted from our Indoor Unit Table according to the outdoor unit capacity.
standards for the determination of load calculation. 3 different types of indoor
design cooling loads. units with cooling capacity from 9000 Btu to
The load calculation is complex and usually 40,000 Btu can be chosen to make the system
time consuming. To simplify the design perfectly suited to your requirements.