You are on page 1of 2

CHECK 

CRACK WIDTH ACCORDING TO ACI 224R‐EQ.4‐2a®

W=0.076 β Fs ( dc * A)^0.33
W=most probable maximum crack width (in)
β=ratio of distance between N.A and tension face to distance between N.A and RFT (y/y 1)
Fs=reinforcing steel service stress (KSI)
dc=thickness of cover from the extreme tension fiber to closest bar (in)
A=area of concrete symmetric with rienfocing steel divided by number of bar (in2)((b*2dc)/n)

b = 100 cm Es= 2100000 kg/cm2


t= 30 cm As= T  16 @ 100 2009.6
dc= 5 1.968504 in As'= T  16 @ 100 2009.6
d'= 5 cm fc'= 300 kg/cm
Mw= 4 m.t where, Sec. type Water‐Retaining Structure crack width limit
Tw= 0 t w= 0.0038 in SAFE
w= 0.09533 mm

d= 25 cm
Ec= 261539.7 kg/cm2
n=Es/Ec= 8.029375
Number of bars 10
z= 7.128006 cm
Fc= 44.31326 kg/cm2
Fs= 892.1141 kg/cm2 12.4896 ksi
A= 100 cm2 15.50388 in2
β= 1.279767
20.096 cm2
20.096 cm2

0.004 in