You are on page 1of 2

CHECK 

CRACK WIDTH ACCORDING TO ACI 224R‐EQ.4‐2a®

W=0.076 β Fs ( dc * A)^0.33
W=most probable maximum crack width (in)
β=ratio of distance between N.A and tension face to distance between N.A and RFT (y/y 1)
Fs=reinforcing steel service stress (KSI)
dc=thickness of cover from the extreme tension fiber to closest bar (in)
A=area of concrete symmetric with rienfocing steel divided by number of bar (in2)((b*2dc)/n)

b = 100 cm Es= 2100000 kg/cm2


t= 40 cm As= T  18 @ 150 1695.6
dc= 6 2.362205 in As'= T  16 @ 150 1339.733333
d'= 6 cm fc'= 300 kg/cm
Mw= 4 m.t where, Sec. type Water‐Retaining Structure crack width limit
Tw= 0 t w= 0.0039 in SAFE
w= 0.09912 mm

d= 34 cm
Ec= 261539.7 kg/cm2
n=Es/Ec= 8.029375
Number of bars 6.666667
z= 8.118757 cm
Fc= 29.201 kg/cm2
Fs= 747.4379 kg/cm2 10.46413 ksi
A= 180 cm2 27.90698 in2
β= 1.231828
16.956 cm2
13.39733 cm2

0.004 in