15 1 G
Event Messages
Z The first two characters “F, E” refer to the category. The middle
two digits “XX” refer to the event. From these two digits the range:
4 Displays/controls, interface
• 1 to 50 describes standard events (uniform basic events) 5 Charger (either on-board or external charger)
which can occur in any function group.
• 51 to 99 describes specific events. 6 Reserved
The event is described in further detail through the last characters 7 Reserved
“S” (single digit / multi-digit).
This process ensures that a unique number is assigned to each 8 Reserved
event. Example:
F Function group Special functions
9
E Event group Example: ISM
XX Event number
S Sub-index
ï í ð ë ï
õUNGHEINRICH Event Messages 03.15 2 G
Sub-division of event group “E” Display system
The system distinguishes between:
Fault reset or
0 • event messages caused by operator errors.
no fault
• event messages caused by truck errors.
General fault / additional functions
For operator errors there are three versions that can be displayed
1 Example:
in the truck depending on the display unit options.
Logic error, e.g. both directions selected simultaneously
• Event number display (e.g. CANDIS)
Current • Pictogram display
2
(input interface, device-internal, output interface) • Text message display
Voltage For truck errors the event number and possibly a fault graphic icon
3
(input interface, device-internal, output interface) (e.g. service key) will also be displayed.
Trucks that only use one luminous display (e.g. LED) use the
4 Temperature
following flashing code:
Hardware • Each character of the four-digit event number is shown with a
5 Example: Output transformer short circuit, EEPROM not 2 Hz / 0.5 sec frequency (flashing).
Z
responding, …
The figure “zero” is displayed by flashing ten times.
Software
(internal software, application software, data record / • After each character of the four-digit event message there is
6 a pause (LED off) of one second.
parameters)
Example: EEPROM data error • After the complete four-digit event message a 3 second
pause (LED off) is set.
7 Additional modules
8 CAN monitoring
External fault
9
Example: ISM
õUNGHEINRICH Event Messages 03.15 3 G
Description / cause / action and effects
Z The following table lists the event message with a description / cause / action and effect.
Each event group (E) with the corresponding event number (XX) can be combined with different function groups (F), hence in the following
table the placeholder “F” is used for the first character “F” of the four-digit event number.
It also shows the operating status when the event occurred:
System end Occurs during truck power-down (correct powering down of components, …)
Evaluation of three key switch inputs. Possible - Check key switch input connection against the
Supply via unexpected key
_ 1 01 1 System start encodings are 1, 2 or 4, otherwise the event message is wiring diagram;
switch input
triggered. - Replace controller;
When the main contactor has switched on the capacitor - Test the main contactor output of the controller;
Contact open instead of
_ 1 2 Self test voltage should be the same as the battery voltage (within - Check wire connection;
closed
500 msec.), otherwise the event message is produced. - Replace contactor;
- Replace controller;
02 Lithium-ion battery 24V/110Ah (in the case of
An attempt is being made to open the main contactor.
repeated faults):
Main contactor permanently The event message is triggered if the monitoring system
_ 1 3 Self test - Check the harness of the lithium-ion battery and
on detects that the main contactor has not opened after T >
replace if necessary;
time limit.
- Replace battery contactor;
- Replace battery management system (BMS);
Feedback signal from main contactor status implausible - Test the main contactor output of the controller;
Self test Main contactor feedback
_ 1 4 with main contactor control (error activated after limit - Check wire connection;
Operation input implausible
time) - Replace contactor;
Output transformer faulty The semi-jumpers 1, 2 and 3 are controlled in turned for - Replace controller;
1 Self test
(phase U) 50 msec at 25% PWM (pulse width modulation) when
the output transformer is closed (“Output transformer
Output transformer faulty
_ 1 03 2 Self test deactivated” signal).
(phase V)
The event message is issued if at the end of the 50 msec
Output transformer faulty period of the respective phase the following applies:
3 Self test VPhase_X < (Vcapacitor / 2) - 25%
(phase W)
õUNGHEINRICH Event Messages 03.15 5 G
F E XX S Operational Description Cause / Triggering Event Action
Status
"Error, power stage ID : The power card of the power - Replace controller;
stage can only obtain faulty information (ID) about the
Error bit set for power
_ 1 04 4 Operation identity and hence suitability of the card for the intended
stage ID
powering of the operating system when the error bit is
set"
Semi-jumpers 1, 2 and 3 are controlled in turn for - Check motor connection wire (wire breakage);
50 msec at 25% PWM (pulse width modulation). - Replace motor;
The event message is issued if at the end of the 50 msec
_ 1 05 1 Self test Motor cutout period of at least one of the two non-controlled phases
the following applies:
VPhase > (Vcapacitor / 4) 25% or
VPhase < (Vcapacitor / 4) - 25%
Semi-jumpers 1, 2 and 3 of a combi controller power - Switch the truck off and on again;
part are controlled in turn for 50 msec at 25% PWM - Check the motor connections;
(pulse width modulation). - Check for a short between two power stages
"Combi controller behaviour
The event message is issued if at the end of the 50 msec or motors;
_ 1 05 2 Self test for non-controlled power
period of at least one of the semi-jumpers of the other - Replace signal-evaluating controller;
stages" logic implausible
power part the following applies:
VPhase_X > (Vcapacitor / 2) + 15% or
VPhase_X < (Vcapacitor / 2) - 15%
õUNGHEINRICH Event Messages 03.15 6 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The safety switch consists of a NC and a NO contact. - Check safety switch wire connection;
When the button is pressed both contacts connect - Check safety switch;
simultaneously. As a result, only the 0/1 and 1/0 - Replace safety switch;
Z
combinations should occur. Safety switches can include:
Safety switch inputs During operation combinations 0/0 and 1/1 (500 msec.) - Deadman (foot switch),
_ 1 06 1 Operation
implausible trigger the event message. - Seat switch,
For a valid combination (0/1 or 1/0, 500 msec) the event - Tiller switch.
message and the truck response are reset. For an
implausible condition the seat switch is considered to
be open (-> the truck brakes with the coasting ramp).
During operation combinations 0/0 and 1/1 (500 msec.) - Check wire connections;
Acknowledge button inputs trigger the event message. - Check button;
_ 1 07 2 Operation
implausible For a valid combination (0/1 or 1/0, 500msecs) the event - Replace button;
and the truck response are reset.
The "Stop" button consists of an NC and an NO contact. - Check parameter reading (side pedestrian mode
When the button is pressed both contacts switch activated?);
simultaneously. As a result, only the 0/1 and 1/0 - Check wire connections;
“Stop" button redundant combinations should occur. - Press "Stop" button;
_ 1 08 3 Operation
inputs” logic improbable During operation the combinations - Replace "Stop" button;
0/0 and 1/1 (500 msec) trigger the event message.
For a valid combination (0/1 or 1/0, 500 msec) the event
message and the truck's response are reset.
õUNGHEINRICH Event Messages 03.15 10 G
F E XX S Operational Description Cause / Triggering Event Action
Status
During operation the combination 1/1 for both buttons - Check wire connection;
pressed simultaneously for 500 msec triggers the - Check button;
Lift/lower digital setpoints following event message. - Replace button;
_ 1 10 1 Operation
are invalid For a valid combination (0/0, 0/1 or 1/0 [button not
pressed / only one button pressed]; 500 msec) the event
message and the truck response are reset.
During operation the limits for 1/1 [both buttons pressed - Check wire connection;
simultaneously] for 500 msec have been exceeded. - Check button;
Lift/lower analog setpoints
_ 1 10 2 Operation For a valid combination (0/0, 0/1 or 1/0 [button not - Replace button;
are invalid
pressed / only one button pressed]; 500 msec) the event
message and the truck response are reset.
The event message is triggered if the following applies - Check wire connection;
Braking setpoint and release for T = 250msec: - Check pedal power supply;
_ 1 11 1 Operation
contact implausible Vbrake pedal < 12.5% and - Replace pedal;
Logic signal release contact = 1 - Replace signal-evaluating controller;
The event message is triggered if the following applies - Check wire connection;
Braking setpoint and release for T = 250msec: - Check pedal power supply;
_ 1 11 2 Operation
contact implausible Vbrake pedal > 25% and - Replace pedal;
Logic signal release contact = 0 - Replace signal-evaluating controller;
The event message is triggered if the following applies - Check wire connection;
Braking setpoint and full for T = 250msec: - Check pedal power supply;
_ 1 11 3 Operation
brake contact implausible Vbrake pedal < 65% and - Replace pedal;
Logic signal full brake contact = 1 - Replace signal-evaluating controller;
The event message is triggered if the following applies - Check wire connection;
Braking setpoint and full for T = 250msec: - Check pedal power supply;
_ 1 11 4 Operation
brake contact implausible Vbrake pedal > 80% and - Replace pedal;
Logic signal full brake contact = 0 - Replace signal-evaluating controller;
õUNGHEINRICH Event Messages 03.15 12 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Combination "brake The event message is triggered - Check brake fluid level;
setpoint" against brake if for T = 250 ms the following applies: - Check proximity sensor;
_ 1 11 6 Operation
pressure invalid (brake • Vbrake pedal < 20% (> 7 volt ) and brake pressure - Check pressure sensors;
pressure without movement) > 20 bar
The event message is triggered if the following applies - Check wire connection;
Travel setpoint and release for T = 250msec: - Check accelerator pedal/tiller arm power supply;
_ 1 12 1 Operation
contact invalid Vaccelerator pedal < 12.5% and - Replace accelerator pedal / tiller arm;
Logic signal release contact = 1 - Replace signal-evaluating controller;
The event message is triggered if the following applies - Check wire connection;
Travel setpoint and release for T = 250msec: - Check accelerator pedal/tiller arm power supply;
_ 1 12 2 Operation
contact invalid Vaccelerator pedal > 25 % and - Replace accelerator pedal / tiller arm;
Logic signal release contact = 0 - Replace signal-evaluating controller;
During operation the combination 1/1 [both travel - Check wire connection;
direction switch / button / twin pedal pressed] for 500 - Check travel direction switch/button/twin pedal;
msec triggers the following event message. - Check travel direction switch/button/twin pedal;
Travel direction 1 and travel
_ 1 13 1 Operation For a valid combination (0/0, 0/1 or 1/0 [travel direction - Replace signal-evaluating controller;
direction 2 invalid
switch/button/twin pedal not pressed or only one travel
direction switch/button/twin pedal pressed]; 500 msec)
the event message and the truck response are reset.
Motor powers without Motor powered for 500 msec without setpoint. - Check motor connections;
_ 1 15 1 Operation
setpoint Logic: implausible status in controller - Check motor model, replace if necessary;
Motor powers without Convergence problem in monitor for the motor speed - Check motor connections;
_ 1 15 2 Operation
setpoint Logic: implausible status in monitor - Check motor model, replace if necessary;
Both speed sensor tracks are counted. When the first - Check speed sensor incrementer channels;
A speed sensor channel deviation limit is reached the system waits for a feasible - Replace speed sensor;
_ 1 17 1 Operation
does not pulse signal from the suspected broken track. When the - Replace signal-evaluating controller;
second limit is reached the event message is generated.
õUNGHEINRICH Event Messages 03.15 15 G
F E XX S Operational Description Cause / Triggering Event Action
Status
No speed signal from the The counts for both incrementers are compared. - Check incrementer signals with multimeter;
travel impulse sensor If the travel incrementer supplies a speed signal of - Check wiring with multimeter;
_ 1 17 3 Operation although travel sensor > 0.05 km/h and the travel pulse contact controller - Replace speed sensor;
indicates greater than incrementer a speed signal of 0 km/h, the event is
0.5 km/h. triggered. The activation limit is 100 msec.
The counts for both incrementers are compared. If the - Check incrementer signals with multimeter;
No speed signal from travel
travel incrementer supplies a speed signal of 0 km/h and - Check wiring with multimeter;
sensor although travel
_ 1 17 4 Operation the travel pulse contact controller incrementer a speed - Replace speed sensor;
impulse sensor indicates
signal of > 0.05 km/h, the event is triggered. The
greater than 0.5 km/h.
activation limit is 100 msec.
Deviation of more than The counts for both incrementers are compared. If the - Check incrementer signals with multimeter;
0.25 km/h between travel speed signals of both incrementers differ by more than - Check wiring with multimeter;
_ 1 17 5 Operation
impulse sensor and travel 0.025 km/h, the event is triggered. The activation limit is - Replace speed sensor;
sensor 100 msec.
õUNGHEINRICH Event Messages 03.15 16 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The counts for both incrementers are compared. If the - Check incrementer signals with multimeter;
Directions obtained from
speed of both incrementers > 0.01 km/h and the - Check wiring with multimeter;
travel sensor and travel
_ 1 17 6 Operation directions of the speed signals for both incrementers are - Replace speed sensor;
impulse sensor are
contradictory, the event is triggered. The activation limit
contradictory
is 100 msec.
One incremental track Both sensor tracks are counted. When the first deviation - Check incrementer signals with multimeter;
height measurement of the limit is reached the system waits for a feasible signal - Check wiring with multimeter;
_ 1 17 7 Operation
proportional lift pulses, the from the suspected broken track. When the second limit - Replace speed sensor;
other does not is reached the event is generated.
One incremental track Both sensor tracks are counted. When the first deviation - Check incrementer signals with multimeter;
height measurement of the limit is reached the system waits for a feasible signal - Check wiring with multimeter;
_ 1 17 8 Operation
free lift pulses, the other from the suspected broken track. When the second limit - Replace speed sensor;
does not is reached the event is generated.
One incremental track Both sensor tracks are counted. When the first deviation - Check incrementer signals with multimeter;
height measurement of the limit is reached the system waits for a feasible signal - Check wiring with multimeter;
_ 1 17 9 Operation
auxiliary lift pulses, the other from the suspected broken track. When the second limit - Replace speed sensor;
does not is reached the event is generated.
The counts for both incrementers are compared. If the lift - Check incrementer signals with multimeter;
Main lift does not lower controller incrementer supplies a speed signal, but the lift - Check wiring with multimeter;
_ 1 17 10 Operation despite the hydraulic motor height measurement incrementer does not supply a - Replace speed sensor;
turning signal after one second, the event is triggered. The
activation limit is 20 msec.
The counts for both incrementers are compared. If the lift - Check incrementer signals with multimeter;
height measurement incrementer supplies a speed - Check wiring with multimeter;
Main lift lowers despite the
_ 1 17 11 Operation signal, but the lift controller incrementer does not supply - Replace speed sensor;
hydraulic motor not turning
a signal after one second, the event is triggered. The
activation limit is 20 msec.
õUNGHEINRICH Event Messages 03.15 17 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The counts for both incrementers are compared. If the - Check the hydraulic system for leaks;
Excessive deviation incrementers for the lift control and lift height - Check incrementer signals with multimeter;
_ 1 17 12 Operation between lift speed and pump measurement are not synchronised within three - Check wiring with multimeter;
speed seconds, the event is triggered. The activation limit is - Replace speed sensor;
100 msec.
The counts for both incrementers are compared. - Check incrementer signals with multimeter;
If the lift controller incrementer supplies a speed signal, - Check wiring with multimeter;
Logic test: Main lift does not
_ 1 17 18 Operation but the lift height measurement incrementer does not - Replace speed sensor;
lower despite pump rotating
supply a signal after one second, the event is triggered.
The activation limit is 20 msec.
The sensor bearing and three channel incrementer are - Test the electrical function of the sensor bearing
Three channel incrementer
synchronised with respect to each other every 120 mm. - Test the mechanical function of the sensor
_ 1 17 23 Operation comparison with sensor
The error is generated if the sensor bearing deviates bearing
bearing incrementer
from the three channel sensor by >= 5 mm.
The event message is triggered - Check wiring from controller to platform lower
if for T >= time limit the following applies: limit sensor;
_ 1 19 1 Operation Cabin position implausible • A change in status of the platform lower-limit sensor - Check / replace lower limit sensor;
from the neutral position into the "Platform raised" - Check lift motor power cables;
position is detected while driving - Replace the signal-generating controller;
õUNGHEINRICH Event Messages 03.15 19 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Excessive slip / drive has probably been tipped - Check motor connection wire (wire breakage);
The AC-3 Power Control (U8) has detected excessive - Check motor model, replace if necessary;
deviation (slip) between the phase current frequency and - Check motor and replace if necessary;
the speed.
The activation limit is 20 msec.
More torque is required from / placed on the motor than it
_ 1 20 1 Operation Drive wheel slip excessive can provide / accept;
Field current is reduced excessively;
Error accompanying sensor bearing control or output
stage protection;
Operating system does not allow enough slip for the
driven motor;
AC-3 Power Control component is damaged
The lift actuator jumper is controlled for max. 40 msec at - Check motor connection wire (wire breakage);
100 % PWM (pulse width modulation). - Check motor model, replace if necessary;
_ 1 21 1 Self test Output stage faulty The event message is triggered if the pump voltage - Replace controller;
drops within this time below 10% of the capacitor
voltage: Vpump > Vcapacitor / 10.
“Digital signal” logic/signal This event message is triggered if the signal shape or - Replace tiller head;
_ 1 22 1
shape implausible modulation of a digital signal is implausible.
The lift height sensor sequence is implausible. This - Check wire connection;
event message is triggered if the following applies for - Check sensor and replace if necessary;
_ 1 24 1 Operation Lift height signal implausible T => 500 msec: - Replace signal-evaluating controller;
Sequence of 2 lift height signals is implausible, e.g.
Top lift height signal without Bottom lift height signal
Integrated lift stroke is greater than 2x the set free lift - Check wire connection;
Lifting stroke greater than 2x
height, however sensor indicates free lift. When the - Check sensor and replace if necessary;
_ 1 24 4 Operation free lift, however mast lift
event occurs, the master assumes that the truck is in the
has not been detected
mast lift stage.
“Initial lowering limit The event message is triggered - Check wire connection;
_ 1 24 6 Operation redundant inputs” logic if for T = 100 ms the following applies: - Check sensor and replace if necessary;
implausible • NC and NO contacts have the same status - Replace signal-evaluating controller;
Integrated lift stroke is greater than 1.5x the set free lift - Check free-lift sensor (position, contamination);
Lift stroke greater than 1.5x height, however sensor indicates free lift. - Check free-lift height setting (JUDIT);
_ 1 24 8 Operation free lift, however mast lift When the event occurs, the master assumes that the - Check pump drive (e.g. worn pump?);
has not been detected truck is in the mast lift stage.
Event is reset when mast lift is detected.
No feedback from relay K1 although the Safe computer - Check wiring with multimeter;
No feedback from relay K1
has been activated. The event message can only be - Check computer component inputs;
_ 1 26 8 Operation despite Safe computer
reset by resetting the truck. The activation limit is - Repair faulty components and replace if
activation
200 msec. necessary;
No feedback from relay K2 although the Safe computer - Check wiring with multimeter;
No feedback from relay K2
has been activated. The event message can only be - Check computer component inputs;
_ 1 26 9 Operation despite Safe computer
reset by resetting the truck. The activation limit is - Repair faulty components and replace if
activation
200 msec. necessary;
No feedback from relay K3 although the Safe computer - Check wiring with multimeter;
No feedback from relay K3
has been activated. The event message can only be - Check computer component inputs;
_ 1 26 10 Operation despite Safe computer
reset by resetting the truck. The activation limit is - Repair faulty components and replace if
activation
200 msec. necessary;
õUNGHEINRICH Event Messages 03.15 25 G
F E XX S Operational Description Cause / Triggering Event Action
Status
No feedback from relay K4 although the Safe computer - Check wiring with multimeter;
No feedback from relay K4
has been activated. The event message can only be - Check computer component inputs;
_ 1 26 11 Operation despite Safe computer
reset by resetting the truck. The activation limit is - Repair faulty components and replace if
activation
200 msec. necessary;
No feedback from main contactor 1 although the Safe - Check wiring with multimeter;
No feedback from main
computer has been activated. The event message can - Check computer component inputs;
_ 1 26 12 Operation contactor 1 despite "main
only be reset by resetting the truck. The activation limit is - Repair faulty components and replace if
contactor 1" signal activation
200 msec. necessary;
No feedback from main contactor 2 although the Safe - Check wiring with multimeter;
No feedback from main
computer has been activated. The event message can - Check computer component inputs;
_ 1 26 13 Operation contactor 2 despite "main
only be reset by resetting the truck. The activation limit is - Repair faulty components and replace if
contactor 2" signal activation
200 msec. necessary;
Power up test for emergency stop circuit by the Safe - Check wiring with multimeter;
Test routine for emergency
computer has failed The event message can only be - Check computer component inputs;
_ 1 26 14 System start stop circuit by the Safe
reset by resetting the truck. The activation limit is - Repair faulty components and replace if
computer has failed
20 msec. necessary;
Redundant controllers of the Safe computer have - Check wiring with multimeter;
Different input statuses
detected different input statuses. The event message - Check computer component inputs;
_ 1 26 15 Operation between the two Safe
can only be reset by resetting the truck. The activation - Repair faulty components and replace if
computers
limit is 100 msec. necessary;
Main Lift stage has lost height without request. The - Check mast mechanics;
Main Lift lowers without
_ 1 27 1 Operation event message appears as soon as the lift height lowers - Check mast hydraulics;
activation signal
by more than 50 mm without request.
Main lift: free lift has lowered The free lift stage has moved hydraulically although the - Check mast mechanics;
_ 1 28 1 Operation
before proportional lift proportional lift stage was not fully retracted. - Check mast hydraulics;
Main lift: proportional lift has The proportional lift stage has moved hydraulically - Check mast mechanics;
_ 1 28 2 Operation
lowered before free lift although the free lift stage was not fully retracted. - Check mast hydraulics;
Aux. lift: Permissible - Compare actual speed with data sheet values;
_ 1 29 2 Operation The permissible lowering speed has been exceeded.
lowering speed exceeded - If it is too high, adjust to data sheet value;
Emergency stop circuit No pulse contact controller has reported charge circuit - Check the charging voltage on the controllers;
power-up test: no activation activation. The charging of the pulse contact controllers - Check wiring;
_ 1 31 2 System start
of any pulse contact must be finished within 10 seconds. The activation limit
controllers is 1000 msec.
The hydraulic controller has not reported charge circuit - Check the charging voltage on the controllers;
Emergency stop circuit
activation. The charging of the pulse contact controllers - Check wiring;
_ 1 31 3 System start power-up test: no lift
must be finished within 10 seconds. The activation limit
controller activation
is 1000 msec.
The traction controller has not reported load circuit - Check the charging voltage on the controllers;
Emergency stop circuit
activation. The charging of the pulse contact controllers - Check wiring;
_ 1 31 4 System start power-up test: no traction
must be finished within 10 seconds. The activation limit
controller activation
is 1000 msec.
õUNGHEINRICH Event Messages 03.15 28 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The steering controller has not reported load circuit - Check the charging voltage on the controllers;
Emergency stop circuit
activation. The charging of the pulse contact controllers - Check wiring;
_ 1 31 5 System start power-up test: no steering
must be finished within 10 seconds. The activation limit
controller activation
is 1000 msec.
Emergency stop circuit Feedback contact of second main contactor level not - Check the charging voltage on the controllers;
_ 1 31 6 System start power-up test: no release of closed within 10 seconds. The activation limit is - Check wiring;
main contactor level 2 1000 msec.
_ 1 31 7 System start
Emergency stop circuit
power-up test: non-defined
Other non-separated event message in main contactor
circuit. This event message does not occur in normal
Z The event message should not occur.
Otherwise contact troubleshooting specialists;
EMERGENCY STOP error operation. The activation limit is 1000 msec.
Referencing of the brake force regulator could not be - Check referencing of the brake force regulator;
Brake force governor:
_ 1 35 1 System start completed after the truck has been switched on. The - Teach-in the function via JUDIT;
referencing failed
triggering threshold is 100 ms.
Left hand support Referencing of the left-hand support could not be - Check referencing of the left-hand support;
_ 1 35 7 System start mushroom: referencing completed after the truck has been switched on. The - Teach-in the function via JUDIT;
failed triggering threshold is 100 ms.
Right hand support Referencing of the right-hand support could not be - Check referencing of the right-hand support;
_ 1 35 9 System start mushroom: referencing completed after the truck has been switched on. The - Teach-in the function via JUDIT;
failed triggering threshold is 100 ms.
Referencing of the "main-lift proportional lift stage" could - Check referencing of the "main lift proportional
Main lift proportional lift
_ 1 35 25 System start not be completed after the truck has been switched on. lift stage";
stage: referencing failed
The triggering threshold is 100 ms. - Teach-in the function via JUDIT;
Referencing of the "main-lift free-lift stage" could not be - Check referencing of the "main-lift free-lift
Main lift free lift stage:
_ 1 35 27 System start completed after the truck has been switched on. The stage";
referencing failed
triggering threshold is 100 ms. - Teach-in the function via JUDIT;
Referencing of the "auxiliary lift" could not be completed - Check referencing of the "auxiliary lift";
_ 1 35 29 System start Aux. lift: referencing failed after the truck has been switched on. The triggering - Teach-in the function via JUDIT;
threshold is 100 ms.
õUNGHEINRICH Event Messages 03.15 33 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Travel control lever: Teach- The teach-in process could not be completed. The - Teach-in the function via Judit;
_ 1 36 23 Operation
in value range too small activation limit is 100 msec.
Accelerator pedal: Teach-in The teach-in process could not be completed. The - Teach-in the function via Judit;
_ 1 36 29 Operation
value range too small activation limit is 100 msec.
Brake pedal: Teach-in value The teach-in process could not be completed. The - Teach-in the function via Judit;
_ 1 36 31 Operation
range too small activation limit is 100 msec.
Target position (extend/retract) of the current collector - Check the mechanics run smoothly;
Collector: Time monitoring
_ 1 39 1 Operation could not be reached within the set time. The triggering
timeout.
threshold is 20 ms.
õUNGHEINRICH Event Messages 03.15 37 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Tolerance field violated Upon reaching the target height and starting the stacking - Check Rack Height Select setpoint setting;
_ 1 40 1 Operation although lift height is cycle, the parametrised tolerance field for the lift height
positioned was exited.
An invalid program condition was detected. Detailed - Save the detailed information from the log book
Lift request although target
_ 1 40 2 Operation information is shown in the log book. The triggering in Judit via the print screen function and send it
lift height exceeded
threshold is 20 ms. to engineering department via VK-B.
An invalid program condition was detected. Detailed - Save the detailed information from the log book
Lower request although
_ 1 40 3 Operation information is shown in the log book. The triggering in Judit via the print screen function and send it
below target lift height
threshold is 20 ms. to engineering department via VK-B.
Load wheel sensor system: Channel A of the left sensor on the load wheel sensor - Check sensor wiring;
_ 1 41 1 Channel A of the left sensor system not supplying pulses. The activation limit is - Measure sensor signals with multimeter;
not counting 20 msec. - Replace sensor;
Load wheel sensor system: Channel B of the left sensor on the load wheel sensor - Check sensor wiring;
_ 1 41 2 Channel B of the left sensor system not supplying pulses. The activation limit is - Measure sensor signals with multimeter;
not counting 20 msec. - Replace sensor;
Load wheel sensor system: Channel A of the right sensor on the load wheel sensor - Check sensor wiring;
_ 1 41 3 Channel A of the right system not supplying pulses. The activation limit is - Measure sensor signals with multimeter;
sensor not counting 20 msec. - Replace sensor;
Load wheel sensor system: Channel B of the right sensor on the load wheel sensor - Check sensor wiring;
_ 1 41 4 Channel B of the right system not supplying pulses. The activation limit is - Measure sensor signals with multimeter;
sensor not counting 20 msec. - Replace sensor;
A new reference point will be defined after track - Measure the wiring;
The left-hand load-wheel
alignment or every 5 m. Based on this reference point, - Check seating of the wheel cover;
_ 1 41 7 Operation sensor is counting less than
the left-hand load-wheel sensor should not show a - Replace sensor;
the right-hand sensor
shorter distance than the right-hand one.
A new reference point will be defined after track - Measure the wiring;
The right-hand load-wheel
alignment or every 5 m. Based on this reference point, - Check seating of the wheel cover;
_ 1 41 8 Operation sensor is counting less than
the left-hand load-wheel sensor should not show a - Replace sensor;
the left-hand sensor
shorter distance than the right-hand one.
- Check wiring;
Both phases of the left-hand Above a measured minimum travel speed, the left-hand
- Test sensor;
_ 1 41 11 Operation load-wheel sensors are load-wheel sensor is still not delivering impulses after the
- Replace sensor;
delivering no impulses time limit has been reached.
- Replace signal-evaluating controller;
- Check wiring;
Both phases of the right- Above a measured minimum travel speed, the right-hand
- Test sensor;
_ 1 41 12 Operation hand load-wheel sensors load-wheel sensor is still not delivering impulses after the
- Replace sensor;
are delivering no impulses time limit has been reached.
- Replace signal-evaluating controller;
- Check wiring;
The frequency determined
The frequency of one of the load-wheel sensors is above - Test sensor;
_ 1 41 13 Operation by the load-wheel sensors is
the limiting value - Replace sensor;
above the valid range
- Replace signal-evaluating controller;
õUNGHEINRICH Event Messages 03.15 39 G
F E XX S Operational Description Cause / Triggering Event Action
Status
- Check CAN-Bus;
When the truck begins to brake, the maximum brake
- Check truck speed values for plausibility;
time is calculated based on the current travel speed.
_ 1 42 1 Operation Truck deceleration too low - Switch the truck off and on again;
As soon as this time is exceeded, the event message is
- Inquire about software update;
triggered.
- Replace signal-issuing controller;
- Check CAN-Bus;
When the truck begins to brake, the minimum
- Check truck speed values are correct;
permissible brake time is calculated based on the
_ 1 42 2 Operation Truck deceleration too great - Switch the truck off and on again;
current travel speed. If this time is not attained, the event
- Inquire about software update;
message is triggered.
- Replace signal-issuing controller;
The event message is triggered when the following - Switch the truck off and on again;
applies: - Check brake system;
_ 1 42 4 Operation Truck deceleration too low
• Travel speed > minimum speed and brake ramp < limit - Inquire about software update;
for 500 ms.
Required brake moment > 10% max. brake moment and - Switch the truck off and on again;
_ 1 42 5 Operation Brake moment implausible
drive system reports motor operation (> 0Nm) - Inquire about software update;
During braking, the actual deceleration is calculated on - Check the settings of the inversion brake using
the basis of the change in travel speed (drive wheel). If the brake log;
_ 1 42 6 Truck deceleration too low
this is below 4.5% for more than 1 second, the - Set the deceleration values to the data sheet
monitoring function applies. values;
õUNGHEINRICH Event Messages 03.15 40 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Membrane key test contact Keypad test contact (loop over connector 1-n) - Replace keypad;
_ 1 44 1 Operation
implausible interrupted for > 100 msec. - Replace control unit;
“Membrane key redundant During the self test a short was detected between the - Replace keypad;
_ 1 44 2 Self test
inputs” logic implausible two contacts of at least one key. - Replace control unit;
“Membrane key redundant During operation an invalid condition was detected on at - Replace keypad;
_ 1 44 3 Operation
inputs” logic implausible least one key for >100 msec. - Replace control unit;
The deviation of the wire guidance sensor to the guide - Check distance signals of both sub-systems
wire is compared in both subcomputers System A and over several points along the guide wire;
"Wire guidance sensor system B. - If the wire guidance sensor (8U7.1) sub-systems
redundant values (8U7.1), The event message is triggered deviate, calibrate and teach the guide wire
_ 1 46 1
load direction system" logic if the following applies: sensors;
improbable • The deviation of the wire guidance sensor to the guide
wire in both subcomputers is greater than 50 mm
• Truck travels a distance of more than 500 mm
õUNGHEINRICH Event Messages 03.15 41 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The deviation of the wire guidance sensor to the guide - Check distance signals of both sub-systems
wire is compared in both subcomputers System A and over several points along the guide wire;
"Wire guidance sensor system B. - If the wire guidance sensor (8U7.2) sub-systems
redundant values (8U7.2), The event message is triggered deviate, calibrate and teach the guide wire
_ 1 46 2
curve drive direction system" if the following applies: sensors;
logic improbable (cornering) • The deviation of the wire guidance sensor to the guide
wire in both subcomputers is greater than 50 mm
• Truck travels a distance of more than 500 mm
The deviation of the wire guidance sensor to the guide - Check distance signals of both sub-systems
wire is compared in both subcomputers System A and over several points along the guide wire;
"Wire guidance sensor system B. - If the wire guidance sensor (8U7.3) sub-systems
redundant values (8U7.3), The event message is triggered deviate, calibrate and teach the guide wire
_ 1 46 3
drive direction system" logic if the following applies: sensors;
improbable • The deviation of the wire guidance sensor to the guide
wire in both subcomputers is greater than 50 mm
• Truck travels a distance of more than 500 mm
Setpoint monitoring logic: “Calculated steering angle - Check steer sensor power supply;
setpoint 1” in control and/or monitoring processor - Check channels A / B for short circuits or
Setpoint control 1 implausible (readings differ); interruption;
_ 1 54 1 Operation
implausible The setpoint directly from the sensor differs between the - Check wire connection;
control processor and the monitoring processor by more - Replace the angle sensor;
than 500 digits five times in a row (50 ms). - Replace signal-evaluating controller;
Actual-value monitoring logic: “Calculated steering angle - Check steer sensor power supply;
actual value” in control and/or monitoring processor - Check channels A / B for short circuits or
Actual value control implausible (readings differ); interruption;
_ 1 58 1 Operation
implausible The actual value directly from the sensor differs between - Check wire connection;
the control processor and the monitoring processor by - Replace the angle sensor;
more than 500 digits five times in a row (50 ms). - Replace signal-evaluating controller;
Referencing run was not completed within T=5s after - Only occurs as a result of other errors;
_ 1 61 1 Self test Timeout during referencing
the start of the self test
õUNGHEINRICH Event Messages 03.15 47 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Relay brake closed instead At the start of the self-test the brake relay is closed - Check wire connection;
_ 1 64 1 Self test
of open instead of open. - Replace signal-issuing controller;
Relay brake closed instead At the end of the self-test the brake relay is closed - Replace signal-issuing controller;
_ 1 64 3 Self test
of open instead of open.
The steered wheel does not Internal monitoring rule violation: - Switch the truck off and on again;
_ 1 67 9 Operation
follow the setpoint Internal status, control status machine implausible
Internal monitoring rule violation: - Switch the truck off and on again;
The steered wheel does not STATUS_STEERING_TYRE_DISCHARGED;
_ 1 67 10 Operation
follow the setpoint Setpoint has changed by more than XX° without the
control processor changing status.
Internal monitoring rule violation: - Switch the truck off and on again;
Rate-ROTATION DIRECTION_LEFT or - Replace signal-issuing controller;
Rated ROTATION DIRECTION_RIGHT;
If the rated-actual difference > small difference, the
The steered wheel does not
_ 1 67 11 Operation system checks whether a current pulse (> YY A) is
follow the setpoint
flowing in the right direction within a particular time
(XX ms).
If this is not the case and the actual-rated difference
rises to > medium difference, an event is triggered.
Internal monitoring rule violation: - Switch the truck off and on again;
Rate-ROTATION DIRECTION_LEFT or - Replace signal-issuing controller;
Rated ROTATION DIRECTION_RIGHT;
The steered wheel does not
_ 1 67 12 Operation If the sub index 11 rule is met (current pulse recognised)
follow the setpoint
and the rated-actual difference continues to rise, the
current must not flow in the wrong direction for more
than a certain time (XX ms).
õUNGHEINRICH Event Messages 03.15 54 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Internal monitoring rule violation: - Switch the truck off and on again;
Specified-actual difference too large. - Check wheel freedom of movement on
Rated-actual difference > maximum rated-actual the ground;
difference - Check steering bolster mechanics;
The steered wheel does not
_ 1 67 13 Operation On many trucks (e.g. EJC) the maximum difference is - Check actual value sensor attachment;
follow the setpoint
prescribed by the mechanical stops. - Test steer motor;
If the current rated-actual difference is more than the
maximum rated-actual difference plus a value “X”,
the event message is triggered
Error during self-test phase - Look for and replace faulty controller during
Steering not requested within 10 s after power up for self
_ 1 69 1 Self test (component has identified self-test.
test
fault) - Inquire about software update;
Internal combustion engine The event message is triggered - Check engine oil level;
_ 1 73 2 Operation specific: Oil quality sensor if the following applies: - Check oil quality sensor and replace if
reading implausible • For T > time limit an engine oil level < limit is measured necessary;
õUNGHEINRICH Event Messages 03.15 57 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The event is triggered when the following applies: - Check the wiring;
• When starting the truck, there is no high signal at one of - Check connected sensor system;
the inputs "swivel seat 0°", "swivel seat 90°" or "swivel - Check controller inputs;
_ 1 78 1 Operation Swivel seat not in position seat 180°" - Replace controller;
• After the seat has been rotated, there is no high signal
at one of the inputs "swivel seat 0°", "swivel seat 90°" or
"swivel seat 180°"
ISM radio channel number ISM: - Check radio channel parameter settings (set
_ 1 91 3 Operation
implausible “Radio channel” parameter set to 0. “radio channel” parameter to 1);
Battery Management System (BMS): - Replace battery (if the problem occurs
_ 1 95 7 Cell temperatures different
Difference between the cell temperatures too large. repeatedly);
The battery capacity has been reduced to 80% of a new - Replace battery if necessary;
_ 1 98 1 Operation Battery useful life expired
battery.
Implausible current The event message is triggered when the following - Replace component;
measurement for I=0A applies:
_ 2 01 5 Self test
(mean current) (current • VCurrent_sensor_prop < VAvAmp_target - 5% or
prop.) • VCurrent_sensor_prop > VAvAmp_target + 5%
õUNGHEINRICH Event Messages 03.15 64 G
F E XX S Operational Description Cause / Triggering Event Action
Status
This event message is triggered if for - Check motor connection cable (short circuit);
“Power connection output” T = 4 ms the following applies: - Check speed sensor, replace if necessary;
_ 2 02 1 Operation
current signal too high • Iphase_U or Iphase_V or Iphase_W > - Check motor and replace if necessary;
Irated_peak + 20% - Replace component;
Phase current too great - Check power circuit wiring (short circuit);
The AC-3 Power Control (U8) has measured an - Replace AC-3 Power Control interface card;
excessive phase current; the error threshold is 25%
above the maximum phase current limit set by the
controller. This depends on the frequency and
temperature and can be adjusted via a parameter.
Internal overcurrent measurement from pulse controller
faulty. The activation limit is 20 msec.
“Power connection output”
_ 2 02 4 Operation The control system has been incorrectly set with regard
current signal too high
to the subordinate current controllers;
Power outputs of the AC-3 Power Control components
have been shorted (either to the power supply or among
each other);
The phase current limit parameter has been adjusted
during operation;
AC-3 Power Control component (current measurement)
is faulty
For 100 msec. the steer current of the control and - Check cable from steer motor to controller A1/
Short circuit steer motor to monitoring processors is different (self-measured A2;
_ 2 02 5 Operation
0 V or power supply current |I-steer| < 4A ; measured current of other
processor |I-steer|> 22A)
õUNGHEINRICH Event Messages 03.15 65 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Warning No activation for Warning Driver supply 1 interrupted. An emergency stop - Check wiring between safe and power
_ 2 07 1 Operation internal driver supply 1 from follows when the controller power stage is activated. The controller;
safety computer. activation limit is 20 msec.
Warning No activation for Warning Driver supply 2 interrupted. An emergency stop - Check wiring between safe and power
_ 2 07 2 Operation internal driver supply 2 from follows when the controller power stage is activated. The controller;
safety computer. activation limit is 20 msec.
The safety function must be triggered - Switch the truck off and on again;
if the following applies: - Check battery cable connection;
Braking current of the • At a braking setpoint (> 80% of the maximum value), - Check the brakes' electrical system;
_ 2 08 1 Operation modulated load wheel brake the current in the outputs of the load wheel brake does - Inquire about software update;
is too low not increases above 2.0 A within T = 200 ms. - Replace signal-issuing controller;
The braking setpoint is a standardised pedal value that is
connected to teach-in values.
The event message is triggered - Switch the truck off and on again;
if for T = 200 ms the following applies: - Check the battery's rated voltage;
Vcapacitor > Vrated voltage + 30%. - Check battery cable connections (transfer
resistance, ...);
Only applies to system trucks: - Check controller cable connections (right
Overvoltage connections, transfer resistance, ...);
The AC-3 Power Control (U8) has measured a battery - Check battery electrolyte level;
Power connection input (+) voltage greater than 125% of the rated voltage with the - Check charger;
_ 3 06 1 Operation
high voltage control system activated; - For a new battery wait for five charge cycles;
Battery is overloaded or incorrect rated voltage; - Replace signal-evaluating controller;
The main contactor was disconnected during active
control (regenerative operation);
Installation of AC-3 Power Control component is
defective;
AC-3 Power Control component (voltage measurement)
is defective;
õUNGHEINRICH Event Messages 03.15 76 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The branch is not controlled (lift actuator of a twin - Check motor connection wire (wire breakage);
“Power connection output” controller). This event message is triggered if the - Check motor and replace if necessary;
_ 3 08 1 Self test
signal implausible following applies for 20 msec: - Replace signal-issuing controller;
Vpower loss < Vcapacitor -20%
The event message is triggered if the following applies - Check wire connection;
“Accelerator pedal input” for T = 250 msec: - Check accelerator pedal power supply;
_ 3 10 1 Operation
signal implausible Vaccelerator pedal > 92.5% or - Replace accelerator pedal;
Vaccelerator pedal < 7.5% - Replace signal-evaluating controller;
The event is triggered when the following applies - Check battery voltage, charge battery if
(hysteresis): necessary;
Power connection input (+) • "On" for T => 100 ms:
_ 3 31 1 Operation
low voltage Measured value Vbatt < Vrated - 20%
• "Off" for T =>100 ms:
Measured value Vbatt > Vrated - 17%
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 1 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 2 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 3 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 4 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
õUNGHEINRICH Event Messages 03.15 99 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 6 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 7 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 21 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 22 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 23 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 24 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 25 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
õUNGHEINRICH Event Messages 03.15 100 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 26 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 31 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 33 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 34 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 35 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 36 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 38 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
õUNGHEINRICH Event Messages 03.15 101 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 39 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 53 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 54 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 55 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 56 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 57 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 58 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
õUNGHEINRICH Event Messages 03.15 102 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Sensor supply voltage is greater than the maximum - Measure voltage output without load;
Sensor supply voltage is limiting value or smaller than the minimum limiting value. - Check connected sensor system for permissible
_ 3 38 63 Operation
outside the tolerance range Subindex = CAN node of the component that is current consumption;
reporting. - Replace component;
Power supply line driver jxp- - Measure voltage output without load;
E1 optional (drive Power supply for output driver 1 (24 V) in CANopen - Check connected actuating system for
_ 3 39 55 Operation
compartment), system B out slave less than 14 V permissible current consumption;
of range - Replace component;
õUNGHEINRICH Event Messages 03.15 104 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Power supply line driver jxp- - Measure voltage output without load;
E1 optional (operator Power supply for output driver 1 (24 V) in CANopen - Check connected actuating system for
_ 3 39 57 Operation
position), system B out of slave less than 14 V permissible current consumption;
range - Replace component;
The event is triggered when the following applies: - Charge the battery
Lilon battery critical low • Battery charge status < limiting value for T > time limit
_ 3 41 1 Operation
voltage OR
• Cell voltage < limiting value at room temperature
The event is triggered when the following applies: - Charge the battery;
• Battery charge status < limiting value for T > time limit
Lilon battery excessive low
_ 3 42 1 Operation OR
voltage
• Cell voltage < limiting value at reduced room
temperature
The event is triggered when the following applies: - Charge the battery;
_ 3 42 2 Operation Minimum cell voltage
• Cell voltage < limiting value at low temperature
õUNGHEINRICH Event Messages 03.15 105 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The event is triggered when the following applies: - Warm battery above 0 °C;
_ 3 42 3 Operation Minimum cell voltage • Cell voltage < limiting value at very low temperature - Charge the battery;
(frost range)
The event is triggered when the following applies: - Charge the battery
_ 3 43 1 Operation Lilon battery full discharge
• Cell voltage < limiting value for T > time limit
SOC battery (internal) = 0% AND charger not detected - Charge the battery
_ 3 43 2 Operation Lilon battery full discharge
for >30 sec
Tiller head sensor: analog Tiller head sensor: - Re-teach the tiller head sensor;
_ 3 70 2…n Operation
signal too high Analog signal limit exceeded. - Replace tiller head;
Tiller head sensor: Analog Tiller head sensor: - Re-teach the tiller head sensor;
_ 3 71 2…n Operation
signal too low Level below analog signal limit. - Replace tiller head;
Tiller head sensor: Analog Tiller head sensor: - Re-teach the tiller head sensor;
_ 3 72 2…n Operation
signal implausible Angle deviation from calibration table too great. - Replace tiller head;
The master must activate an event message if the - Check cable connection;
following conditions apply: - Check external travel direction switch power
- Channel A voltage less than minimum limit OR supply;
“Travel direction input” - Channel B voltage less than minimum limit OR - Replace external travel direction switch;
_ 3 80 2 Operation
signal implausible - Channel A voltage greater than maximum limit OR
- Channel B voltage greater than maximum limit OR
- Total voltage less than limit 1 OR
- Total voltage greater than limit 2.
A magnetic external field has been detected on the - Check for, and if necessary remove, a
control pilot which affects the Hall sensor system for the permanent magnet in the vicinity of the control
Only applies to control pilot:
respective function (see sub index). The pilot issues the element
_ 3 82 1 Operation External magnetic field
safe zero condition for the function concerned. If the - Check the wiring
detected on axis 1
function is no longer violated it is enabled again and the - Check the control element power supply
current setpoint transmitted. - Replace control element
A magnetic external field has been detected on the - Check for presence of permanent magnet near
control pilot which affects the Hall sensor system for the the control and remove if necessary;
Only applies to control pilot:
respective function (see sub index). The pilot issues the - Check cable connection;
_ 3 82 2 Operation External magnetic field
safe zero condition for the function concerned. If the - Check control power supply;
detected on axis 2
function is no longer violated it is enabled again and the - Replace control;
current setpoint transmitted.
A magnetic external field has been detected on the - Check for presence of permanent magnet near
control pilot which affects the Hall sensor system for the the control and remove if necessary;
Only applies to control pilot:
respective function (see sub index). The pilot issues the - Check cable connection;
_ 3 82 3 Operation External magnetic field
safe zero condition for the function concerned. If the - Check control power supply;
detected on axis 3
function is no longer violated it is enabled again and the - Replace control;
current setpoint transmitted.
õUNGHEINRICH Event Messages 03.15 108 G
F E XX S Operational Description Cause / Triggering Event Action
Status
A magnetic external field has been detected on the - Check for presence of permanent magnet near
control pilot which affects the Hall sensor system for the the control and remove if necessary;
Only applies to control pilot:
respective function (see sub index). The pilot issues the - Check cable connection;
_ 3 82 4 Operation External magnetic field
safe zero condition for the function concerned. If the - Check control power supply;
detected on axis 4
function is no longer violated it is enabled again and the - Replace control;
current setpoint transmitted.
A magnetic external field has been detected on the - Check for presence of permanent magnet near
control pilot which affects the Hall sensor system for the the control and remove if necessary;
Control pilot specific:
respective function (see sub index). The pilot issues the - Check cable connection;
_ 3 82 5 Operation Magnetic external field
safe zero condition for the function concerned. If the - Check control power supply;
detects direction encoder
function is no longer violated it is enabled again and the - Replace control;
current setpoint transmitted.
A magnetic external field has been detected on the - Check for presence of permanent magnet near
Only applies to control pilot: control pilot which affects the Hall sensor system for the the control and remove if necessary;
External magnetic field on respective function (see sub index). The pilot issues the - Check cable connection;
_ 3 82 6 Operation
axis 5 or changeover button safe zero condition for the function concerned. If the - Check control power supply;
detected function is no longer violated it is enabled again and the - Replace control;
current setpoint transmitted.
A magnetic external field has been detected on the - Check for presence of permanent magnet near
control pilot which affects the Hall sensor system for the the control and remove if necessary;
Only applies to control pilot:
respective function (see sub index). The pilot issues the - Check cable connection;
_ 3 82 7 Operation External magnetic field
safe zero condition for the function concerned. If the - Check control power supply;
detected on horn button
function is no longer violated it is enabled again and the - Replace control;
current setpoint transmitted.
A magnetic external field has been detected on the - Check for presence of permanent magnet near
Only applies to control pilot: control pilot which affects the Hall sensor system for the the control and remove if necessary;
External magnetic field respective function (see sub index). The pilot issues the - Check cable connection;
_ 3 82 8 Operation
detected on safe zero condition for the function concerned. If the - Check control power supply;
acknowledgement button function is no longer violated it is enabled again and the - Replace control;
current setpoint transmitted.
õUNGHEINRICH Event Messages 03.15 109 G
F E XX S Operational Description Cause / Triggering Event Action
Status
“Internal components” temperature range exceeded (too - Allow the controllers to cool;
large) - Check ventilation inputs and outputs, clean if
• The event is triggered when the following applies necessary;
(hysteresis): - Check the air flow through the heat sinks and
• "On" when temperature > lower temperature limit; clean if necessary;
• "Off" when temperature < lower temperature limit - 2? - Check assembly on heat dissipater (heat
The event message remains upon leaving this area and conductivity);
entering an area with higher temperatures. - Test fans and replace if necessary;
- Replace signal-evaluating controller;
Component temperature Only applies to system trucks:
_ 4 02 1…n Operation
over-exceeded Non-permissible heatsink temperature;
The AC-3 Power Control (U8) has measured a heatsink
temperature greater than 90 °C or less than –25 °C;
Fans no longer working or air flow through heatsink
restricted;
The AC-3 Power Control has been overloaded;
Ambient temperature is very high and the AC-3 Power
Control is being overloaded;
AC-3 Power Control component (temperature
measurement) is faulty
The event is triggered when the following applies - Measure the temperature at the location of the
“Internal components” (hysteresis): component;
_ 4 07 1…n Undefined temperature range not • "On" when temperature < temperature limit; - Measure the temperature of the component;
achieved (significantly) • "Off" when temperature > temperature limit + hysteresis - Compare the temperatures and replace the
value component if necessary;
The event is triggered when the following applies - Allow the hydraulic system to cool down;
(hysteresis): - Check and, if necessary, clean the ventilation
“Hydraulic oil” temperature
• "On" when temperature > activation temperature; inlets;
_ 4 11 1 Operation range exceeded
• "Off" when temperature < activation temperature - 5 K - Check fan controller parameters;
(significantly)
(the event message remains upon leaving this area and - Check if the lift mast and/or hydraulic motors
entering an area at a higher temperature) can move freely;
The event is triggered when the following applies - Allow the hydraulic system to cool down;
(hysteresis): - Check ventilation inputs and outputs, clean if
“Hydraulic oil” temperature • "On" when temperature > lower temperature limit; necessary;
_ 4 12 1 Operation
range exceeded (too high) • "Off" when temperature < lower temperature limit - 5 K - Check fan controller parameters;
(the event message remains upon leaving this area and - Check mast can move freely;
entering an area at a higher temperature)
Battery temperature The event is triggered when the following applies: - Use the battery in a warmer environment
_ 4 13 1 Operation
worryingly low • Internal battery temperature is below limiting value 1
Battery temperature too far The event is triggered when the following applies: - Use battery in a warmer environment;
_ 4 13 2 Operation
below lower limit • Internal battery temperature is below limiting value 2
The event is triggered when the following applies - Measure the temperature at the location of the
“Internal components” (hysteresis): component;
_ 4 14 1...n Operation temperature range not • "On" when temperature < temperature limit; - Measure the temperature of the component;
achieved (too great) • "Off" when temperature > temperature limit + hysteresis - Compare the temperatures and replace the
value component if necessary;
õUNGHEINRICH Event Messages 03.15 116 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The event is triggered when the following applies - Measure the temperature at the location of the
“Internal components” (hysteresis): component;
_ 4 15 1...n Operation temperature range not • "On" when temperature < temperature limit; - Measure the temperature of the component;
achieved (critically) • "Off" when temperature > temperature limit + hysteresis - Compare the temperatures and replace the
value component if necessary;
The event is triggered when the following applies - Allow the coolant to cool down;
(hysteresis): - Check and, if necessary, clean the inlets and
Coolant temperature range
• "On" when temperature > lower temperature limit; outlets;
_ 4 16 1 Operation has been (significantly)
• "Off" when temperature < lower temperature limit - 5 K - Check fan controller parameters;
exceeded
(the event message remains upon leaving this area and - Check if the lift mast and/or hydraulic motors
entering an area at a higher temperature) can move freely;
“Driver circuit output transformer” hardware signal - Switch the truck off and on again;
activated (main jumper); - Check motor cable (short circuit);
External interruption of MOSFET driver circuit activated. - Check speed sensor and replace if necessary;
- Check motor and replace if necessary;
Only applies to system trucks: - Replace component
Output transformer has cut out; (Only applies to L&S trucks:
The hardware-side output transformer protection of the - Replace AC-3 Power Control interface card);
Output transformer driver
_ 5 01 1 Operation AC-3 Power Control (U8)has been triggered and the
connection activated
output transformer has switched into the de-energised
state (three-state logic) if this is possible;
Power outputs of the AC-3 Power Control component
have been short-circuited (either to the power supply or
to each other);
AC-3 Power Control component (output transformer or
output transformer protection) is faulty;
The event message is triggered - Check cable from steer motor to controller A1/
“Comparator switch”
if for T = 200 ms the following applies: A2;
_ 5 01 4 Operation hardware signal triggered
• HW comparator switch triggered and the current - Replace steer motor;
(steer motor shorted)
reading is less than 10 A - Replace controller;
õUNGHEINRICH Event Messages 03.15 118 G
F E XX S Operational Description Cause / Triggering Event Action
Status
This event message is triggered - Switch the truck off and on again;
Internal processor control
_ 5 02 1 Operation if for T < 10 msec the "external watchdog" hardware - Replace component;
implausible
signal is implausible (processed too quickly).
This event message is triggered - Switch the truck off and on again;
Internal processor control
_ 5 02 2 Operation if for T > 100 msec the "external watchdog" hardware - Replace component;
implausible
signal is implausible (processed too slowly).
When the external watchdog runs out the output - Switch the truck off and on again;
"External watchdog" transformers / basic outputs are not switched off. - Replace component;
_ 5 02 3 Self test hardware signal improbable "External watchdog" hardware signal implausible
(not output stage disable) Signal permanently displayed / output transformer not
deactivated.
Internal processor control This event message is triggered - Switch the truck off and on again;
_ 5 02 4 Operation
implausible if the "external watchdog" does not start within 10 msec. - Replace component;
This event message is triggered - Switch the truck off and on again;
Internal processor control
_ 5 02 5 Operation if the initial activation of the external watchdog was not - Replace component;
implausible
successful.
- Clear logbook;
This event message is triggered - Set truck type;
System start
_ 5 03 1…n EEProm does not respond if the EEPROM has not responded forty times in - Set hour meter;
Operation
succession. - Set default parameters;
- Replace controller;
õUNGHEINRICH Event Messages 03.15 119 G
F E XX S Operational Description Cause / Triggering Event Action
Status
No speed signal from fan present when the fan is - Check fan wire connection;
modulated (fan does not rotate?) - Check fan freedom of movement;
_ 5 08 1 Undefined Fan not working correctly
Or - Replace fan;
Fan current implausible - Replace signal-issuing controller;
The event message is triggered - Switch the truck off and on again;
System start Co-processor does not
_ 5 09 1 if for T = 2 s the following applies: - Replace component;
Operation communicate
• Processor not triggered by co-processor
Error bit set in jxp Interface for evaluating controls in control panel reports - Contact Technical Support;
_ 5 24 1 Self test
component panel fault. The activation limit is 20 msec. - Replace components if necessary;
õUNGHEINRICH Event Messages 03.15 121 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Error bit set in jxp Drive compartment interface reports error. The activation - Contact Technical Support;
_ 5 24 3 Self test
component Interface IDS limit is 20 msec. - Replace components if necessary;
Error bit set in jxp Drive compartment interface (DPI) reports error. The - Contact Technical Support;
_ 5 24 6 Self test
component Interface DPI activation limit is 20 msec. - Replace components if necessary;
Error bit set in jxp Interface in operator position / load handler (MIO) reports - Contact Technical Support;
_ 5 24 7 Self test
component Interface Mio error. The activation limit is 20 msec. - Replace components if necessary;
Error bit set in jxp Drive1 interface reports error. The activation limit is - Contact Technical Support;
_ 5 24 9 Self test
component Drive1 20 msec. - Replace components if necessary;
Error bit set in jxp Drive2 interface reports error. The activation limit is - Contact Technical Support;
_ 5 24 10 Self test
component Drive2 20 msec. - Replace components if necessary;
Error bit set in jxp Drive3 interface reports error. The activation limit is - Contact Technical Support;
_ 5 24 11 Self test
component Drive3 20 msec. - Replace components if necessary;
Error bit set in jxp Interface DK reports error. The activation limit is - Contact Technical Support;
_ 5 24 15 Self test
component Interface DK 20 msec. - Replace components if necessary;
Error bit set in jxp Interface 1 optional type 1 reports error. The activation - Contact Technical Support;
_ 5 24 21 Self test
component E1 threshold is 20 msec. - Replace components if necessary;
Error bit set in jxp Interface 1 optional type 2 reports error. The activation - Contact Technical Support;
_ 5 24 22 Self test
component E2 limit is 20 msec. - Replace components if necessary;
Error bit set in jxp Interface 1 optional type3 reports error. The activation - Contact Technical Support;
_ 5 24 26 Self test
component E3 limit is 20 msec. - Replace components if necessary;
Error of slave set in Safe A CANopen slave in the network reports an error. The - Contact Technical Support;
_ 5 24 64 Self test
computers activation limit is 20 msec. - Replace components if necessary;
Transponder: faulty The last transponder reading contained faulty - Check the signal strength of the readers via
_ 5 60 8
transponder data reading transponder data. The activation limit is 20 msec. transponders;
Transponder: transponder The last transponder contains invalid transponder data. - Check the transponder data content and re-
_ 5 60 9
data invalid The activation limit is 20 msec. program if necessary.
Transponder analysis: aisle The aisle status is active without having detected an - Check the transponder routing;
_ 5 60 12 active without transponder entry direction via transponders. The activation limit is 20 - Check the signal strength of the readers via
information msec. transponders;
Reflex marker not identified in the expected area. - Manually move the shuttle to the channel start
The activation limit is 20 msec. - Repeat travel command at channel start
- Check rail hole sensors 7B33.1, 7B33.2 for
contamination, incorrect settings and faults
- Check incremental transmitter 1B5
Warehouse navigation:
- Check wire connection
_ 5 61 1 Operation Expected reflex marker
Signal change expected at 7B33.1 - Check drive chain
not found Signals of 7B33.1 and 7B33.2 differ - Check position of rail holes, they should lie
No signals from incremental transmitter 1B5 directly opposite each other
- Check rail holes and travel channel for
contamination
- Check the shuttle in a different travel channel
Minimum marker distance in mm: (2 * marker tolerance) - Check the transponder routing;
+ marker width; if the distance between two markers is - Check the arrangement of the reflex markers;
Horizontal positioning: less than the above minimum distance, the error
_ 5 61 4 distance between markers message appears after a job is entered. Remedy: reduce
smaller than tolerance the 'marker tolerance' parameter or set up the
warehouse so that the distance between the markers
is greater.
If the 'positioning tolerance' parameter is less than half - Check parameter setting;
the 'marker width' parameter, the truck must be
Horizontal positioning:
positioned exactly on a marker. The error can occur if
_ 5 61 5 positioned within tolerance,
for example the laser scanner attachment is loose or if
but no marker
positions are stored wrongly during teach-in or during
commissioning.
õUNGHEINRICH Event Messages 03.15 126 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The 'correction stop load direction / drive direction' value - Check parameter setting;
Horizontal positioning: is restricted to 50 mm. When this has been reach, exact
_ 5 61 6 adjustment stop value at positioning is not possible. Check the 'HP/LN default
limit, positioning not possible settings - stopping distance, positioning distance and
braking distance' setting
Safety data record not Safety data record not loaded in Safe computer or not - Load safety data record into Safe.
_ 6 08 2 System start
loaded in Safe computer correct. The activation limit is 20 msec.
Serial number in safety data record does not match the - Load the respective safety data record into Safe.
Serial number in safety data
truck dongle. Invalid safety data record installed for this
_ 6 08 3 System start record does not match the
truck or electronic serial number of dongle invalid. The
dongle
activation threshold is 20 msec.
Cross-check of redundant The results of processing the program cycles in the two - Check operating system in the subcomputers A
_ 6 08 4 Safe computers does not Safe computers do not match. The activation limit is and B;
match 20 msec.
The Adjustment_Steer angle - Ensure the service parameters are the same in
transmission parameter The parameter settings in the truck do not match the the Master and the Safe.
_ 6 08 11 System start deviates from the service service parameters in the Safe. The activation limit is
parameter setting in the 20 msec.
Safe.
No pointer issued to data Pointer for parameter file data sink invalid. The activation - Contact Technical Support;
_ 6 12 11 System start
variable limit is 20 msec. - Replace master component if necessary;
õUNGHEINRICH Event Messages 03.15 132 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Data from data source Memory for parameter information could not be read. - Contact Technical Support;
_ 6 12 13 System start
cannot be read The activation limit is 20 msec. - Replace master component if necessary;
Memory for data copy not Data sink cannot be written to. The activation limit is - Contact Technical Support;
_ 6 12 14 System start
responding 20 msec. - Replace master component if necessary;
Faulty parameter file Parameter file checksum invalid. The activation limit is - Contact Technical Support;
_ 6 12 15 System start
checksum 20 msec. - Replace master component if necessary;
Material number: Software is not the same as the - Set truck type;
material number stored in the EEPROM. - Switch the truck off and on again;
EEPROM layout does not
_ 6 15 1 System start Or - Set hour meter;
match current software.
Actual version or number for a saved parameter group - Set default parameters;
does not match the nominal version or number - Replace controller;
One or more parameters set to default values. - When updating the operating system:
The AC-3 Power Control (U8) operating system has New parameters are set to default when the
calculated invalid parameter combinations and set one truck is switched off and on again, event
or more parameters to the default specified in the message is reset after the truck is switched on;
program. - Check the operating system and install the
The activation limit is 20 msec. correct one if necessary;
The master has specifically set one or more parameters - Replace the AC-3 Power Control (U8);
to default values.
An operating system has been installed on the AC-3
Power Control component with a different AC-3 Power
parameters set to default
_ 6 18 4 Self test Control ID than before;
after error
The operating system is faulty and contains default
settings that are out of the permissible setting range for
parameters;
Parameter memory is faulty, the correct value of a
parameter could not be calculated and has therefore
been set to default;
AC-3 Power Control component (parameter memory) is
faulty;
This message is not necessarily an error, but it should at
least be reported to the master.
An invalid combination of several parameters has been - Check the parameter setting via JUDIT and
Invalid parameter set. e.g.: adjust if necessary;
_ 6 19 1 Operation
combination • Parameter combination auxiliary hydraulics extension
and acknowledgement button function
Warehouse navigation: Warehouse navigation parameter setting: - Set parameters to valid setting;
_ 6 19 4 warehouse structure Warehouse structure parameters implausible. The
parameters faulty activation limit is 20 msec.
Invalid parameter The parameter combination Aux. Lift extend and lift - Check the parameter setting via JUDIT and
_ 6 19 5 Operation
combination cutout option is invalid adjust if necessary;
Invalid parameter Load wheel brake parameter and load wheel brake - Change brake parameter;
_ 6 19 7 System start
combination inspection do not match - Check brakes;
Invalid parameter The engine type and ECU encoding parameters are not - Check/change engine type parameter;
_ 6 19 21 Operation
combination compatible
Set A in the LED version and the StVZO lighting - Check/change the Set A parameter;
Invalid parameter
_ 6 19 22 Operation (German road traffic equipment) have been configured - Check/change StVZO parameter;
combination
at the same time
System start Value of parameters "Axle 3, level 1" AND "Axle 4, level - Check/change parameter axle level 1;
Invalid parameter
_ 6 19 24 Self test 1" > 0 AND "Axle 3, level 1" is the same as parameter
combination
Operation "Axle 4, level 1"
Invalid parameter At least 2 of the parameters "Key-1" to "Key-6" have the - Check/change parameters "Key-1" to "Key-6"
_ 6 19 27 Operation
combination same parameter value NOT EQUAL TO 0
The following bits are set simultaneously in the "Auxiliary - Check/change "Auxiliary spotlights" parameter;
spotlights" parameter:
Invalid parameter
_ 6 19 29 Operation - Bit 5 AND 6 OR
combination
- Bit 5 AND 7 OR
- Bit 6 AND 7;
The following bits are set simultaneously in the "Front - Check/change "Front spotlights" parameter;
spotlights" parameter:
Invalid parameter
_ 6 19 30 Operation - Bit 5 AND 6 OR
combination
- Bit 5 AND 7 OR
- Bit 6 AND 7;
The following bits are set simultaneously in the "Rear - Check/change "Rear spotlights" parameter;
spotlights" parameter:
Invalid parameter
_ 6 19 31 Operation - Bit 5 AND 6 OR
combination
- Bit 5 AND 7 OR
- Bit 6 AND 7;
Invalid parameter Bits 7 AND 13 are set simultaneously in the "CUST - Check "CUST output 1" parameter, adjust if
_ 6 19 33 Operation
combination Output 1" parameter necessary;
Invalid parameter Bits 7 AND 13 are set simultaneously in the "CUST - Check "CUST output 2" parameter, adjust if
_ 6 19 34 Operation
combination Output 2" parameter necessary;
Invalid parameter Bits 7 AND 13 are set simultaneously in the "CUST - Check "CUST output 3" parameter, adjust if
_ 6 19 35 Operation
combination Output 3" parameter necessary;
õUNGHEINRICH Event Messages 03.15 139 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Invalid parameter The wrong voltage class is set in the "Battery voltage" - Check the "battery voltage" parameter and
_ 6 19 37 Operation
combination parameter adjust if necessary;
In the "Cust-Softkeysymbol 1" parameter a setting not - Check the following parameters and adjust if
equal to 0 has been entered and this setting is not the necessary:
same as the CUST-Softkeysymbol 1 number from the - Cust-Softkeysymbol 1,
display OR - Cust-Softkeysymbol 2,
In the "Cust-Softkeysymbol 2" parameter a setting not - Cust-Softkeysymbol 3,
Invalid parameter equal to 0 has been entered and this setting is not the
_ 6 19 38 Operation
combination same as the CUST-Softkeysymbol 2 number from the
display OR
In the "Cust-Softkeysymbol 3" parameter a setting not
equal to 0 has been entered and this setting is not the
same as the CUST-Softkeysymbol 3 number from the
display OR
In the "Cust-Icon 1" parameter a setting not equal to 0 - Check the following parameters and adjust if
has been entered and this setting is not the same as the necessary:
CUST-Icon symbol 1 number from the display OR - Cust-Icon 1,
In the "Cust-Icon 2" parameter a setting not equal to 0 - Cust-Icon 2,
Invalid parameter
_ 6 19 39 Operation has been entered and this setting is not the same as the - Cust-Icon 3,
combination
CUST-Icon symbol 2 number from the display OR
In the "Cust-Icon 3" parameter a setting not equal to 0
has been entered and this setting is not the same as the
CUST-Icon symbol 3 number from the display OR
õUNGHEINRICH Event Messages 03.15 140 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Too many events indicated this message is issued if more than 64 events are issued - Minimise events (<64)
_ 6 20 1 Operation
at the same time at the same time - Replace controller
Checksum invalid in EEPROM area: - Switch the truck off and on again;
“Discharge indictor" data
_ 6 24 1 Undefined 0x00A0 - 0x00AF - Replace controller;
EEPROM range invalid
For details see EEPROM layout document
“Mac address battery Checksum invalid in EEPROM area: - Switch the truck off and on again;
_ 6 25 1 Undefined controller" data EEPROM 0x00B0 - 0x00BF - Replace controller;
range invalid For details see EEPROM layout document
Checksum invalid in EEPROM area: - Switch the truck off and on again;
“Mac address charger" data
_ 6 25 2 Undefined 0x00C0 - 0x00CF - Replace controller;
EEPROM range invalid
For details see EEPROM layout document
õUNGHEINRICH Event Messages 03.15 142 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Code for this truck is invalid. The sub index shows the - Wrong release code entered.
Code number position "sub
_ 6 26 0...63 System start position number of the wrong code. The activation limit is - Check the release code via JUDIT and adjust if
index" is incorrect.
20 msec. necessary.
The truck parameter setting The parameter settings in the truck do not match the - Safety data records in the two safe systems do
_ 6 27 1 System start does not match the safety approved parameters in the safety data record. The not match.
data record activation limit is 20 msec. - Load safety data records via JUDIT.
_ 6 28 1 Operation
Entry in logbook if time is
changed – old time
The logbook records the time and date settings before
the change. The triggering threshold is 20 ms.
Z The event message is used to document a
change in time. No action required.
_ 6 28 2 Operation
Entry in logbook when time
is adjusted – new time
The logbook records the time and date settings in the
truck. The triggering threshold is 20 ms.
Z The event message is used to document a
change in time. No action required.
Brake force governor: Analog sensor not taught. Commissioning not - Carry out teach-in via JUDIT;
_ 6 30 1 System start
Potentiometer not taught performed. The activation limit is 100 msec.
Traverse sensor: Analog sensor not taught. Commissioning not - Carry out teach-in via JUDIT;
_ 6 30 3 System start
Potentiometer not taught performed. The activation limit is 100 msec.
Rotate sensor: Analog sensor not taught. Commissioning not - Carry out teach-in via JUDIT;
_ 6 30 5 System start
Potentiometer not taught performed. The activation limit is 100 msec.
Steering setpoint device: Analog sensor not taught. Commissioning not - Carry out teach-in via JUDIT;
_ 6 30 13 System start
Potentiometer not taught performed. The activation limit is 100 msec.
Hydraulic setpoint device: Analog sensor not taught. Commissioning not - Carry out teach-in via JUDIT;
_ 6 30 21 System start
Potentiometer not taught performed. The activation limit is 100 msec.
Travel setpoint device: Analog sensor not taught. Commissioning not - Carry out teach-in via JUDIT;
_ 6 30 23 System start
Potentiometer not taught performed. The activation limit is 100 msec.
Mechanical stops of brake force governor not set. - Carry out teach-in via JUDIT;
Brake force governor: Brake
_ 6 31 1 System start Commissioning not performed. The activation limit is
geometry not taught
100 msec.
õUNGHEINRICH Event Messages 03.15 145 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Deceleration levels of brake force governor not set. - Carry out teach-in via JUDIT;
Brake force governor:
_ 6 31 2 System start Commissioning not performed. The activation limit is
Deceleration levels not set
100 msec.
Mechanical stops of "traverse" sensor not set. - Carry out teach-in via JUDIT;
Traverse sensor: Geometry
_ 6 31 3 System start Commissioning not performed. The activation limit is
not taught
100 msec.
Position of sideshifter index switch not set. - Carry out teach-in via JUDIT;
Traverse sensor: index
_ 6 31 4 System start Commissioning not performed. The activation limit is
switch not taught
100 msec.
Mechanical stops of "rotate" sensor not set. - Carry out teach-in via JUDIT;
Rotate sensor: Geometry
_ 6 31 5 System start Commissioning not performed. The activation limit is
not taught,
100 msec.
Left hand support Mechanical stops of left support mushroom not set. - Carry out teach-in via JUDIT;
_ 6 31 7 System start mushroom: Geometry not Commissioning not performed. The activation limit is
taught 100 msec.
Right hand support Mechanical stops of right support mushroom not set. - Carry out teach-in via JUDIT;
_ 6 31 9 System start mushroom: Geometry not Commissioning not performed. The activation limit is
taught 100 msec.
Mechanical stops of proportional lift not set. - Carry out teach-in via JUDIT;
Proportional lift: Geometry
_ 6 31 31 System start Commissioning not performed. The activation limit is
not taught
100 msec.
Free lift: Geometry not Mechanical stops of free lift not set. Commissioning not - Carry out teach-in via JUDIT;
_ 6 31 33 System start
taught performed. The activation limit is 100 msec.
Aux. lift: Geometry not Mechanical stops of auxiliary lift not set. Commissioning - Carry out teach-in via JUDIT;
_ 6 31 35 System start
taught not performed. The activation limit is 100 msec.
Mechanical stops of fork positioner not set. - Carry out teach-in via JUDIT;
Fork positioner: Geometry
_ 6 31 37 System start Commissioning not performed. The activation limit is
not taught
100 msec.
õUNGHEINRICH Event Messages 03.15 146 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Mechanical stops of optional fork positioner not set. - Carry out teach-in via JUDIT;
Optional fork positioner:
_ 6 31 38 System start Commissioning not performed. The activation limit is
Geometry not taught
100 msec.
Sideshifter: Geometry not Mechanical stops of sideshifter not set. Commissioning - Carry out teach-in via JUDIT;
_ 6 31 39 System start
taught not performed. The activation limit is 100 msec.
Mechanical stops of left current collector not set. - Carry out teach-in via JUDIT;
Left current collector:
_ 6 31 40 System start Commissioning not performed. The activation limit is
Geometry not taught
100 msec.
Mechanical stops of right current collector not set. - Carry out teach-in via JUDIT;
Right current collector:
_ 6 31 41 System start Commissioning not performed. The activation limit is
Geometry not taught
100 msec.
Brake force governor: Switched-on position deviates from switched-off position - Carry out a reference run:
_ 6 33 1 System start deviation from switched-off by more than 20° (angle sensor). The activation limit is - Re-teach the brake force governor via Judit;
position 100 msec.
Switched-on position deviates from switched-off position - Carry out a reference run:
Traverse sensor: deviation
_ 6 33 3 System start by more than 20° (angle sensor). The activation limit is - Re-teach the traverse sensor via JUDIT;
from switched-off position
100 msec.
Switched-on position deviates from switched-off position - Carry out a reference run:
Rotate sensor: deviation
_ 6 33 5 System start by more than 20° (angle sensor). The activation limit is - Re-teach the rotate sensor via JUDIT;
from switched-off position
100 msec.
Left hand support Switched-on position deviates from switched-off position - Carry out a reference run:
_ 6 33 7 System start mushroom: deviation from by more than 20° (angle sensor). The activation limit is - Re-teach the left support mushroom via JUDIT;
switched-off position 100 msec.
Right hand support Switched-on position deviates from switched-off position - Carry out a reference run:
_ 6 33 9 System start mushroom: deviation from by more than 20° (angle sensor). The activation limit is - Re-teach the right support mushroom via JUDIT;
switched-off position 100 msec.
Rotate: below minimum The set position has been abandoned. The activation - Carry out teach-in via JUDIT;
_ 6 35 5 Operation
position limit is 100 msec.
õUNGHEINRICH Event Messages 03.15 147 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Rotate: above maximum The set position has been abandoned. The activation - Carry out teach-in via JUDIT;
_ 6 35 6 Operation
position limit is 100 msec.
Proportional lift: below The set position has been abandoned. The activation - Carry out teach-in via JUDIT;
_ 6 35 31 Operation
minimum position limit is 100 msec.
Proportional lift: above The set position has been abandoned. The activation - Carry out teach-in via JUDIT;
_ 6 35 32 Operation
maximum position limit is 100 msec.
Free lift: below minimum The set position has been abandoned. The activation - Carry out teach-in via JUDIT;
_ 6 35 33 Operation
position limit is 100 msec.
Free lift: above maximum The set position has been abandoned. The activation - Carry out teach-in via JUDIT;
_ 6 35 34 Operation
position limit is 100 msec.
Aux. lift: below minimum The set position has been abandoned. The activation - Carry out teach-in via JUDIT;
_ 6 35 35 Operation
position limit is 100 msec.
Aux. lift: above maximum The set position has been abandoned. The activation - Carry out teach-in via JUDIT;
_ 6 35 36 Operation
position limit is 100 msec.
_ 6 37 1 Operation Safety functions modified Event issued by changing the service safety parameter - Switch truck off and on again;
Tilt: Geometry not taught, Mechanical stops of tilt sensor not set. The activation - Teach the tilt sensor with JUDIT;
_ 6 38 1 System start
carry out commissioning point is 100 msec.
Hydraulic lever capacitive Hydraulic lever capacitive switch not taught. The - Carry out teach-in via JUDIT;
_ 6 44 1 System start
switch not taught activation limit is 20 msec.
Travel lever capacitive Travel lever capacitive switch not taught. The activation - Carry out teach-in via JUDIT;
_ 6 44 2 System start
switch not taught limit is 20 msec.
Minimum requirements for The software version for this component is too old for the - Update the operating system of the component
_ 6 45 1…n
software version not met. truck version. The activation limit is 20 msec. to the required version.
Minimum requirements for The software version for this component is too old for the - Update the operating system of the component
_ 6 45 65-68
software version not met. truck version. The activation limit is 20 msec. to the required version.
Event number unknown Event message not known. - Switch the truck off and on again;
_ 6 54 1 Operation
(implausible) Event number received unknown (UART) - Inquire about software update;
Event number unknown Event message not known. - Switch the truck off and on again;
_ 6 54 2 Operation
(implausible) Own event number implausible (UART) - Inquire about software update;
Event number unknown Event message not known to control processor. Event - Switch the truck off and on again;
_ 6 54 3 Operation
(implausible) response received is implausible (UART) - Inquire about software update;
õUNGHEINRICH Event Messages 03.15 151 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Safety-critical functions not performed during operation. - Switch the truck off and on again;
Monitoring of cyclical
_ 6 56 4 Operation If not all routines are performed once within 20 ms, the - Inquire about software update;
functions activated
event message is triggered. - Replace signal-issuing controller;
The cycle time lay between 20 msec and 22 msec. - Reset event via emergency stop reset;
Cycle time 20 msec. The activation limit is 20 msec. The event message is - If the error occurs permanently contact
_ 6 56 5 Operation
exceeded retentive and can only be reset by an Emergency Stop Technical Support;
reset.
The cycle time lay between 22 msec and 24 msec. - Reset event via emergency stop reset;
Cycle time 22 msec. The activation limit is 22 msec. The event message is - If the error occurs permanently contact
_ 6 56 6 Operation
exceeded retentive and can only be reset by an Emergency Stop Technical Support;
reset.
õUNGHEINRICH Event Messages 03.15 152 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The cycle time was above 24 msec. The activation limit - Reset event via emergency stop reset;
Cycle time 24 msec.
_ 6 56 7 Operation is 24 msec. The event message is retentive and can only - If the error occurs permanently contact
exceeded
be reset by an Emergency Stop reset. Technical Support;
The steering setpoint device type parameter does - Set parameters to the correct setpoint device;
_ 6 59 1 Self test Setpoint device invalid not match the steering setpoint device type that is
connected.
Safety clearance set between the rotating and the - Adjust the traverse/rotate movement via JUDIT;
sideshifting load and rack was not observed. The
Traverse/rotate movement:
traverse-rotate operation was cancelled. Monitoring is
_ 6 62 1 Operation safety distance too short,
necessary if the load is rotated and swivelled in the
risk of collision with rack
narrow aisle to prevent it colliding with the racking. The
triggering threshold is 20 ms.
- Check pilot;
An unknown or faulty reading for the pilot type is read by
_ 6 71 2 System start Pilot type incompatible - Check for software update;
the master from the EEPROM of the pilot.
- Replace controller;
Wire guidance frequency change: Wire guidance - Check sensor frequency setting;
Wire guidance sensors set
_ 6 74 3 Operation sensors are set to different frequencies. The activation
to different frequencies
limit is 20 msec.
ISM: "Parameter 5" value > ISM: - Set parameter 5 to less than parameter 6;
_ 6 81 1 Undefined
"Parameter 6" Set standby timeout to be lower than truck timeout.
Information message: The debug mode is now activated. The truck must only Z Event message should only appear in
development test mode.
_ 6 98 1 System start Debug mode activated be operated by test personnel. The activation limit is
in truck software 20 msec.
- If this error occurs contact Technical Support;
Information message: An invalid program condition was detected. Detailed Z Event message should only appear in
development test mode.
_ 6 99 1 Self test Programming error in truck information is shown in the log book. The triggering
software threshold is 20 ms.
- If this error occurs contact Technical Support;
Tolerance field violated An invalid program condition was detected. Detailed Z Event message should only appear in
development test mode.
_ 6 99 4 Self test although lift height is information is shown in the log book. The triggering
positioned threshold is 20 ms.
- If this error occurs contact Technical Support;
A truck function has requested truck deceleration - Check truck controller cut-out function;
Undefined Stop monitoring: Travel via the mechanical brakes. However the required
deceleration was not introduced within 1 second.
_ 7 01 1
A truck function has requested a main lift hydraulic stop. - Check truck controller cut-out function;
Undefined Stop monitoring: Main Lift However the main lift cut-out was not introduced within
0.5 seconds.
A truck function has requested an aux. lift hydraulic stop. - Check truck controller cut-out function;
_ 7 01 2 Undefined Stop monitoring: Aux. lift However the aux. lift cut-out was not introduced within
0.5 seconds.
õUNGHEINRICH Event Messages 03.15 160 G
F E XX S Operational Description Cause / Triggering Event Action
Status
A truck function has requested a sideshift hydraulic stop. - Check truck controller cut-out function;
_ 7 01 3 Undefined Stop monitoring: Sideshift However the sideshift cut-out was not introduced within
0.5 seconds.
A truck function has requested a rotary movement - Check truck controller cut-out function;
_ 7 01 4 Undefined Stop monitoring: Rotate hydraulic stop. However the rotary movement cut-out
was not introduced within 0.5 seconds.
Stop monitoring: power Emergency stop circuit power-up test: 24 volt power not - Check emergency stop circuit wiring
_ 7 01 12 Undefined
emergency stop circuit received within 200 msec.
Stop monitoring: load circuit Emergency stop circuit power-up test: load circuit - Check emergency stop circuit wiring
_ 7 01 13 Undefined
emergency stop circuit release not received within 200 msec.
Stop monitoring: two- Emergency stop circuit power-up test: the signals of - Check emergency stop circuit wiring
_ 7 01 15 Undefined channel signal emergency jxpSafeC1 and jxpSafe C2 are different for more than
stop circuit 20 msec.
A truck function has requested truck deceleration via the - Check truck controller cut-out function;
Undefined Endpoint monitoring: Travel inversion brake. However the required deceleration was - Check the brake ramp settings;
not introduced within 1 second.
_ 7 02 1 A truck function has requested the termination of - Check truck controller cut-out function;
Endpoint monitoring: Main the main lift operation via the setpoint ramp. However - Check the brake ramp settings;
Undefined
Lift the termination of the main lift operation was not
introduced within 1 second.
A truck function has requested the termination of - Check truck controller cut-out function;
the aux. lift operation via the setpoint ramp. However - Check the brake ramp settings;
_ 7 02 2 Undefined Endpoint monitoring: Aux. lift
the termination of the aux. lift operation was not
introduced within 1 second.
A truck function has requested the termination of - Check truck controller cut-out function;
Endpoint monitoring: the sideshift operation via the setpoint ramp. However - Check the brake ramp settings;
_ 7 02 3 Undefined
Sideshift the termination of the sideshift operation was not
introduced within 1 second.
A truck function has requested the termination of the - Check truck controller cut-out function;
rotary movement via the setpoint ramp. However the - Check the brake ramp settings;
_ 7 02 4 Undefined Endpoint monitoring: Rotate
termination of the rotary movement was not introduced
within 1 second.
- Replace controller
Safety computer data check Faulty data bytes of sub-computer A/B detected within
_ 7 02 21 Undefined - If this error occurs permanently contact
interrupted limit time (xxmsec)
Technical Support;
- Replace controller
_ 7 02 22 Undefined SYNC interrupted Faulty SYNC detected within limit time (xxmsec) - If this error occurs permanently contact
Technical Support;
- Replace controller
Faulty CANopen node ID detected within limit time
_ 7 02 23 Undefined Slave identity interrupted - If this error occurs permanently contact
(xxmsec)
Technical Support;
- Replace controller;
Steering emergency stop
_ 7 02 32 Undefined Fault in emergency stop circuit of electric steering - If this error occurs permanently contact
circuit faulty
Technical Support;
Faulty delay in monitoring "control position neutral - Check the sensor system attached
"Control position" safety
_ 7 02 50 Undefined setting" monitoring of sub-computer A/B detected within - Check outputs / inputs with JUDIT;
function reports fault
limit time (xxmsec) - Replace controller;
Faulty delay in monitoring "control part neutral setting" - Check the sensor system attached
"Control parts" safety
_ 7 02 51 Undefined monitoring of sub-computer A/B detected within limit - Check outputs / inputs with JUDIT;
function reports fault
time (xxmsec) - Replace controller;
Faulty delay in monitoring "parking brake release" - Check the sensor system attached
"Parking brake release"
_ 7 02 55 Undefined monitoring of sub-computer A/B detected within limit - Check outputs / inputs with JUDIT;
safety function reports fault
time (xxmsec) - Replace controller;
The truck function has requested a truck deceleration - Check the inching speed setting against the
Inching speed monitoring:
Undefined to 2.5 km/h. However the required deceleration to crawl data sheet values;
Travel
speed was not introduced within 1 second. - Check the brake ramp settings;
_ 7 03 1
The truck function has requested a reduction of the main - Check the inching speed setting against the
Inching speed monitoring:
Undefined lift speed to crawl speed. However the reduction of the data sheet values;
Main Lift
main lift speed was not introduced within 1 second. - Check the brake ramp settings;
The truck function has requested a reduction of the - Check the inching speed setting against the
Inching speed monitoring:
_ 7 03 2 Undefined aux. lift speed to crawl speed. However the reduction of data sheet values;
Aux. lift
the aux. lift speed was not introduced within 1 second. - Check the brake ramp settings;
The truck function has requested a reduction of the - Check the inching speed setting against the
Inching speed monitoring:
_ 7 03 3 Undefined sideshift speed to crawl speed. However the reduction of data sheet values;
Sideshift
the sideshift speed was not introduced within 1 second. - Check the brake ramp settings;
The truck function has requested a reduction of - Check the inching speed setting against
Inching speed monitoring:
_ 7 03 4 Undefined the rotary speed to crawl speed. However the reduction the data sheet values;
Rotate
of the rotary speed was not introduced within 1 second. - Check the brake ramp settings;
The truck moves despite The travel speed has been exceeded by more than the - Check the maximum speed setting against the
Operation
travel cutout limit. data sheet values;
- Check the brake ramp setting;
_ 7 05 1 - Check the application which led to the event
Main Lift raises despite lift Monitoring module: despite an active cutout a speed being triggered (e.g. operation beyond
Operation
cutout above a limit or an active lift drive is detected. specification due to high travel speed on leaving
a ramp)
Main Lift lowers despite Monitoring module: Despite an active cutout a speed - Check truck controller cut-out function;
_ 7 05 2 Operation
lower cutout > 10 mm/s is detected - Check the brake ramp settings;
The sideshift moves despite Monitoring module: Despite an active cutout a speed - Check truck controller cut-out function;
_ 7 05 3 Operation
lower cutout > 10 mm/s is detected - Check the brake ramp settings;
The truck moves despite Monitoring module: Despite an active cutout a speed - Check truck controller cut-out function;
_ 7 05 4 Operation
rotate cutout > 1 °/s is detected - Check the brake ramp settings;
The truck moves despite Monitoring module: Despite a power-up test error - Check truck controller cut-out function;
Operation
power-up test error a speed > 0.1 km/s is detected - Check the brake ramp settings;
_ 7 05 10
The Main Lift moves despite Monitoring module: Despite a power-up test error - Check truck controller cut-out function;
Operation
power-up test error a speed > 10 mm/s is detected - Check the brake ramp settings;
The Main Lift moves despite Monitoring module: Despite a stop a speed > 10 mm/s - Check truck controller cut-out function;
_ 7 05 11 Operation
an overspeed error is detected - Check the brake ramp settings;
õUNGHEINRICH Event Messages 03.15 170 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Main lift moves despite error Monitoring module: A speed > 10 mm/s is detected - Check truck controller cut-out function;
_ 7 05 15
(lift chain not taut) despite error (lift chain not taut) - Check the brake ramp settings;
Travel inching speed Monitoring module: during an active speed reduction to - Check the inching speed setting against the
_ 7 05 16 exceeded despite foot inching speed, due to a foot switch error a travel speed > data sheet values;
switch error V_INCH is detected - Check the brake ramp settings;
õUNGHEINRICH Event Messages 03.15 171 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Monitoring module: during an active speed reduction to - Check the inching speed setting against the
Travel inching speed
_ 7 05 17 inching speed, due to a gate error a travel speed > data sheet values;
exceeded despite gate error
V_INCH is detected - Check the brake ramp settings;
Travel inching speed Monitoring module: during an active speed reduction to - Check the inching speed setting against the
exceeded despite brake inching speed, due to a brake force governor error a data sheet values;
force governor error travel speed > V_INCH is detected - Check the brake ramp settings;
_ 7 05 20
The Aux. Lift moves despite Monitoring module: Despite a power-up test error a - Check truck controller cut-out function;
Operation
power-up test error speed > 10 mm/s is detected
The Aux. Lift moves despite Monitoring module: Despite a stop a speed > 10 mm/s is - Check truck controller cut-out function;
_ 7 05 21 Operation
an overspeed error detected
The truck moves despite Monitoring module: Despite a PPS protection field stop a - Check truck controller cut-out function;
_ 7 05 25
protection field change error speed > 0.1 km/s is detected
õUNGHEINRICH Event Messages 03.15 172 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The maximum permitted The maximum permitted speed for the steering angle - Verification of the actuation by the higher-order
_ 7 05 26 Operation speed for the steering angle has been exceeded, e.g. due to the steering angle being system (layout)
has been exceeded. changed too quickly.
The sideshifter moves Monitoring module: Despite a power-up test error a - Check truck controller cut-out function;
_ 7 05 30
despite power-up test error speed > 10 mm/s is detected
The sideshifter moves Monitoring module: Despite a stop a speed > 10 mm/s is - Check truck controller cut-out function;
_ 7 05 31
despite an overspeed error detected
The rotary drive moves Monitoring module: Despite a power-up test error a - Check truck controller cut-out function;
_ 7 05 40
despite power-up test error speed > 5 °/s is detected
The rotary drive moves Monitoring module: Despite a stop a speed > 5 °/s is - Check truck controller cut-out function;
_ 7 05 41
despite an overspeed error detected
Rotate inching speed - Check the inching speed setting against the
Monitoring module: during an active speed reduction to
_ 7 05 44 exceeded despite reduction data sheet values;
inching speed a rotate speed > V_INCH is detected
to inching speed - Check the brake ramp settings;
Emergency stop through Emergency stop during operation through safety - If this error occurs permanently contact
_ 7 06 1 Operation
safety computer computer (response to EMCY emergency stop) Technical Support;
No setpoint available from accelerator pedal (travel - Check traction motor speed sensors, replace if
Prevent accidental start-up
_ 7 07 1 Operation setpoint), the speed-evaluating inputs detect a changing necessary.
from stationary position
actual speed.
õUNGHEINRICH Event Messages 03.15 173 G
F E XX S Operational Description Cause / Triggering Event Action
Status
No request made for "Move Attachment" operating - Check Pilot signals, replace Pilot if necessary;
functions. - Check outputs of signal-issuing controller;
Prevent attachments from
_ 7 07 17 Operation Nevertheless the valve current reading does not reduce. - replace signal-generating controller;
moving automatically
As a result the valve current reading is sufficient to open
the valve.
The seat switch reports an unoccupied driver s seat. - Check signal issuing controller, replace if
Ensure the operator is in the
_ 7 07 22 Operation No falling travel speeds (traction motor speeds) and/or necessary;
normal operating position
decreasing valve currents detected.
With parameter settings for "Belt lock" and "Access - Check belt lock, replace if necessary;
control" an open belt lock is detected during the following
Ensure the driver restraint
_ 7 07 23 Operation truck movements / operations:
systems are used
- Travel operations
- Hydraulic functions activated
õUNGHEINRICH Event Messages 03.15 176 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The monitored ramp stop is requested as a response - Check traction motor speed sensors, replace if
_ 7 07 27 Operation Monitored ramp stop from several safety features necessary.
Out of range of speed-dependent deceleration corridor
"Sub index" test stage Event message for monitoring testing in development.
Z Event message should only appear in
development test mode.
_ 7 51 1...10 Operation
timeout The activation limit is 20 msec.
- If this error occurs contact Technical Support;
õUNGHEINRICH Event Messages 03.15 177 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Wire guidance aisle travel, - Check wire routing and ground conditions;
The steer angle actual value has been exceeded by
_ 7 53 1 Operation permissible steer angle
more than 1.8°. The activation limit is 20 msec.
actual value exceeded
Wire guidance aisle travel, - Check wire routing and ground conditions;
The steer angle setpoint has been exceeded by more
_ 7 53 2 Operation permissible steer angle
than 1.5°. The activation limit is 20 msec.
setpoint exceeded
After the positive flank of 7B37.4 there is no positive - Manually move the shuttle to the channel start
UPC specific:
flank at 7B37.2 - Check pallet detection sensors 7B37.1-7B37.4
_ 7 56 1 Operation Pallet positioning sensor
After the positive flank of 7B37.3 there is no positive for contamination, incorrect settings and faults
faulty
flank at 7B37.1 - Check wire connection
Driver error from stack. Sub index means: - Check the physical properties of the CAN Bus;
1: Bus off - Measure the CAN-Bus signal;
The master has been informed via CiA Emergency - Check CAN-Bus signals for frame leakage;
Error Code 8140 that a node is reporting error - Check equipotential bonding;
"Recovered from Bus Off". - Check terminal resistances (60 ± 10%);
_ 8 01 1 Operation CAN Bus faulty Events are entered with the node number of the - Check CAN-Bus via JUDIT
transmitting component (CAN-Bus load, ...);
The function assembly used is the function assembly - Bypass components connected to the CAN-Bus
of the transmitting component. in turn;
Events recognised by the master are entered with - Replace controller;
node number 1 and function assembly 0.
õUNGHEINRICH Event Messages 03.15 181 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Driver error from stack. Sub index means: - Check the physical properties of the CAN Bus;
2: Driver switched to “passive” - Measure the CAN-Bus signal;
The master has been informed via EMCY ID 8120 that - Check CAN-Bus signals for frame leakage;
a node is reporting error "CAN in Error Passive Mode". - Check equipotential bonding;
Events are entered with the node number of the - Check terminal resistances (60 ± 10%);
_ 8 01 2 Operation CAN Bus faulty
transmitting component - Check CAN-Bus via JUDIT
The function assembly used is the function assembly (CAN-Bus load, ...);
of the transmitting component. - Bypass components connected to the CAN-Bus
Events recognised by the master are entered with in turn;
node number 1 and function assembly 0. - Replace controller;
Driver error from stack. Sub index means: - Check CAN-Bus load via JUDIT;
4: Receive buffer (Rx) has overrun (software) - Switch optional components off from CAN-Bus,
Events are entered with the node number of the e.g. road traffic lighting.
transmitting component
_ 8 01 4 Operation CAN Bus faulty
The function assembly used is the function assembly
of the transmitting component.
Events recognised by the master are entered with
node number 1 and function assembly 0.
õUNGHEINRICH Event Messages 03.15 182 G
F E XX S Operational Description Cause / Triggering Event Action
Status
- Read logbook:
- Check the physical properties of the CAN Bus;
- Measure the CAN-Bus signal;
- Check CAN-Bus signals for frame leakage;
- Check equipotential bonding;
Internal software error - Check terminal resistances (60 ± 10%);
_ 8 04 1…n Undefined Software error
(error return value of a stack function). - Check CAN-Bus via JUDIT
(CAN-Bus load, ...);
- Bypass components connected to the CAN-Bus
in turn;
- Inquire about software update;
- Replace controller;
õUNGHEINRICH Event Messages 03.15 184 G
F E XX S Operational Description Cause / Triggering Event Action
Status
_ For T = 3.5 x heartbeat time of monitored node: - Check power supply of the component
Heartbeat telegram not received connected to the CAN-Bus (faulty contact);
_ Sub-index: monitored node. - Check component heartbeat time
The master has been informed via EMCY ID 8130 that (CANopen object 1017);
a node is reporting error "Life Guard Error or Heartbeat - Check the physical properties of the CAN Bus;
Error". - Measure the CAN-Bus signal;
Events are entered with the node number of the - Check CAN-Bus signals for frame leakage;
Heartbeat telegram
8 05 1…32 Operation transmitting component - Check equipotential bonding;
monitoring
The function assembly used is the function assembly - Check terminal resistances (60 ± 10%);
_ of the transmitting component. - Check CAN-Bus via JUDIT
Events recognised by the master are entered with (CAN-Bus load, ...);
node number 1 and function assembly of the remaining - Bypass components connected to the CAN-Bus
heartbeat. in turn;
The sub index represents the node number of - Replace controller;
the remaining heartbeat.
- Read logbook:
- Check optional components (unexpected
Unexpected CAN node Boot up message of an optional component which is set
_ 8 06 1…n System start nodes);
report as not being present.
- Release / activate or remove unexpected node
by parameter if not required.
The master is informed via EMCY ID 8210 that a node - Inquire about software update;
has received an unexpectedly short process data object
(PDO).
Telegram between master/ Events are entered with the node number of the
_ 8 08 1 Operation slave implausible / software transmitting component
error The function assembly used is the function assembly
of the transmitting component.
Events recognised by the master are entered with
node number 1 and function assembly 0.
õUNGHEINRICH Event Messages 03.15 185 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The master is informed via EMCY ID 8220 that a node - Inquire about software update;
has received an unexpectedly long process data object
(PDO).
Telegram between master/ Events are entered with the node number of the
_ 8 08 2 Operation slave implausible (too long) / transmitting component
software error The function assembly used is the function assembly
of the transmitting component.
Events recognised by the master are entered with
node number 1 and function assembly 0.
The master has been informed via EMCY ID 8230 that - Inquire about software update;
a node is reporting error "DAM MPDO not processed,
destination object not available".
Events are entered with the node number of the
_ 8 08 3 Operation Unexpected Multiplex-PDO transmitting component
The function assembly used is the function assembly
of the transmitting component.
Events recognised by the master are entered with node
number 1 and function assembly 0.
For T = 3.5 x PDO cycle of the monitored node: - Check the physical properties of the CAN Bus;
PDO not received - Measure the CAN-Bus signal;
Sub-index: monitored node. - Check CAN-Bus signals for frame leakage;
The master is informed via EMCY ID 8250 that a node - Check equipotential bonding;
has not received a receipt PDO in the expected time. - Check terminal resistances (60 ± 10%);
Receive error; telegram
_ 8 09 1…32 Operation Events are entered with the node number of the - Check CAN-Bus via JUDIT
remains off
transmitting component (CAN-Bus load, ...);
The function assembly used is the function assembly - Bypass components connected to the CAN-Bus
of the transmitting component. in turn;
Events recognised by the master are entered with node - Replace controller;
number 1 and function assembly 0.
õUNGHEINRICH Event Messages 03.15 186 G
F E XX S Operational Description Cause / Triggering Event Action
Status
_ 8 12 1 Operation
Error message evaluated
incorrectly
Controller reports faulty (non-defined) emergency
telegram. The activation limit is 20 msec. Z The event message should not occur.
Otherwise contact troubleshooting
specialists;
The master has been informed via EMCY ID 8150 that - Inquire about software update;
a node is reporting the collision of CAN-ID's.
Events are entered with the node number of the
transmitting component
_ 8 14 1...32 Operation Collision of CAN-ID's
The function assembly used is the function assembly
of the transmitting component.
Events recognised by the master are entered with
node number 1 and function assembly 0.
The master is informed via EMCY ID 8240 that a node - Inquire about software update;
has received an unexpected SYNCH length.
Events are entered with the node number of the
_ 8 15 1...32 Operation Unexpected synch length
transmitting component
The function assembly used is the function assembly
of the transmitting component.
õUNGHEINRICH Event Messages 03.15 195 G
F E XX S Operational Description Cause / Triggering Event Action
Status
The master has been notified via EMCY of a CAN-Open - Inquire about software update;
CiA error code to which no event message has been
Non-assigned CAN-Open assigned.
_ 8 16 1...32 Operation CiA error in emergency Events are entered with the node number of the
report of a node transmitting component
The function assembly used is the function assembly
of the transmitting component.
Z
System start “Safety switch” input and
_ 9 02 1 • A lifting setpoint was already present when the safety Safety switches can include:
Operation “lift” setpoint invalid
switch was pressed - Deadman (foot switch),
This event message can be triggered by incorrect - Seat switch,
operation. - Tiller switch.
For system trucks:
- Switch the truck off and on again.
Do not apply the control lever on power up.
- If the error still occurs, check the sensor
components and recuperating springs;
Z
This event message can be triggered by incorrect
operation. Safety switches can include:
- Deadman (foot switch),
- Seat switch,
- Tiller switch.
õUNGHEINRICH Event Messages 03.15 198 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Z
combination invalid This event message can be triggered by incorrect
operation. Safety switches can include:
- Deadman (foot switch),
- Seat switch,
- Tiller switch.
Z
switch not applied
combination invalid Safety switches can include:
This event message can be triggered by incorrect
operation. - Deadman (foot switch),
- Seat switch,
- Tiller switch.
The “battery latch open” signal is applied when the truck - Latch battery / close battery door;
is stationary (< 1 km/h). - Check wire connections;
The event message is triggered - Check “battery latch” sensor, adjust and replace
Battery door not closed and
if for T >= 500 ms the following applies: if necessary;
_ 9 15 1 Operation travel speed less than
• Battery door not closed and travel speed less than - Check signal-evaluating controller and replace if
1 km/h
1 km/h necessary;
This event message can be triggered by incorrect
operation.
The “battery latch open” signal is applied when the truck - Latch battery / close battery door;
is moving (>= 1 km/h). - Check wire connections;
The event message is triggered - Check “battery latch” sensor, adjust and replace
Battery door not closed and
if for T >= 500 ms the following applies: if necessary;
_ 9 15 2 Operation travel speed greater than or
• Battery door not closed and travel speed greater than - Check signal-evaluating controller and replace if
equal to 1 km/h
or equal to 1 km/h necessary;
This event message can be triggered by incorrect
operation.
õUNGHEINRICH Event Messages 03.15 201 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Z
This event message is an information message.
Travel cutout deactivated if the travel
setpoint is zero and the input is closed.
The truck brakes to a halt (activated via JUDIT). This tests the service brake.
“Service brake test” service
_ 9 20 1 Operation This event message is an information message. The event message and the brake activation are reset when
function
the truck is switched off and on again.
The main contactor is opened by the service engineer (activated via JUDIT). This allows the engineer to
check whether the main contactor can switch as an emergency stop device.
Operation
This event message is an information message. The event message and the JUDIT control are reset when
the truck is switched off and on again.
The regenerative brake is switched off by the service engineer to test the mechanical service brake
(activated via JUDIT). This allows the mechanical service brake to be tested in isolation. When the test has
“Mechanical service brake
_ 9 22 1 Operation been completed switch the truck off and on again.
test” service function
This event message is an information message. The event message and the regenerative brake cutout are
reset after 5 min. or when the truck is switched off and on again.
“Safety valve test” service To test the safety valve the lowering valve is opened in full (activated via JUDIT).
_ 9 23 1 Operation
function This event message is an information message.
õUNGHEINRICH Event Messages 03.15 204 G
F E XX S Operational Description Cause / Triggering Event Action
Status
When the truck is idle and all hydraulic levers are in - This event message is an information message.
the home position, press the SET key on the display
“Depressurise hydraulic
for 3 seconds to start the process for depressurising
_ 9 24 1 Operation manifold” service function
the ZH (auxiliary) functions. The start is indicated by
active
a beep, the end by two beeps. The truck must then be
switched off.
The spring-loaded brake of the automatic parking brake - 'This event message is an information message.
'Test spring-loaded brake of
can be applied by the service engineer (activated via The event message and the JUDIT control are
_ 9 29 1 Operation automatic parking brake'
JUDIT). This enables service work to be performed on reset when the truck is switched off and on
service function activated
the spring brake cylinder. again.
After the service function "depressurising the valve - 'This event message is for information only.
Cancelling the active service
block" was activated, depressurised mode was - Switch the system off and on again;
_ 9 30 1 Operation function "depressurising the
cancelled by starting the engine or because an error - Check event report;
valve block"
occurred.
Information message: the engine control unit has - This event message is for information only;
_ 9 33 1 Operation Particle filter loading is high detected that the limiting value for the particle filter - Read ECU error logbook;
loading has been exceeded. - Proceed according to the repair manual;
Information message: the engine control unit has - This event message is for information only;
Particle filter loading is
_ 9 34 1 Operation detected an error during the regeneration of the diesel - Read ECU error logbook;
critical
particle filter. - Proceed according to the repair manual;
õUNGHEINRICH Event Messages 03.15 206 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Toggle switch for level 2 not - This event message is an information message;
Toggle switch for level 2 applied despite function in level
_ 9 37 2 Operation applied and function in level - Note the operating sequence;
2 still being performed
2 not yet completed
Several individual functions requested simultaneously - This event message is an information message;
Several individual functions
_ 9 37 3 Operation with the control handle, despite at least one of the - Note the operating sequence;
requested simultaneously
hydraulic functions being set as a single function.
Seat switch and deadman The event message is triggered - Check seat / deadman switch on passenger
switch on passenger seat if for T > 500 ms the following applies: seat;
_ 9 39 1 Operation
implausible • The combination of seat and deadman switch for the - Note to operator in case of incorrect operation;
passenger seat is invalid (0/1 or 1/0)
Parking brake button applied The parking brake pre-selection is activated and the high - This event message is an information message;
_ 9 40 1 Operation for too long level of the parking brake signal has been detected for - Do not apply the parking brake button;
longer than 5 secs.
Backup dongle save or The master saves the parameters in the Backup dongle - This event message is an information message;
_ 9 41 1 Operation
restore active or restores the settings from the backup dongle. - Do not switch the system off;
The event message is triggered when the following - This event message is an information message;
Operating position applies: - Perform status change of operating position
_ 9 43 1 Operation
monitoring time exceeded • After T > time limit, no operating position change switch;
detected
Z
least one hydraulic function was present.
This event message can be triggered by incorrect Safety switches can include:
operation. - Totmanntaster (Fußtaster),
- Seat switch,
- Tiller switch.
õUNGHEINRICH Event Messages 03.15 208 G
F E XX S Operational Description Cause / Triggering Event Action
Status
Z
This event message can be triggered by incorrect
operation. Safety switches can include:
- Deadman (foot switch),
- Seat switch,
- Tiller switch.
Control specific: Control applied or button pressed, but conditions for - see truck operating instructions data plate;
_ 9 53 1 Operation
Incorrect operation function not met.
1 Master
- CANDIS;
- JULIA;
3 Display 1
- On board computer;
- Multifunction armrest display;
7 Lifting
8 Travel 1
9 Travel 2
10 MULTI-PILOT / SOLO-PILOT 2
- MFC 1 (brakes);
11 Interface 1
- E box;
15 Display 2
16 Battery controller
17 Charger
18 Spare
28 Access 1 - CanCode;
õUNGHEINRICH Event Messages 03.15 214 G
CAN-Bus node ID Description Lift of components with fixed CAN-Bus node ID
29 Access 2 - ISM;
30 Service PC