You are on page 1of 65

AH-X075E/X095E

AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

SERVICE MANUAL
S45B8AYX095E/

SPLIT TYPE
ROOM AIR CONDITIONERS
INDOOR UNIT
MODELS AH-X075E/X095E
AY-X075E/X095E
OUTDOOR UNIT
AU-X075E/X095E
AE-X075E/X095E
In the interests of user-safety (Required by safety regulations in some
countries) the set should be restored to its original condition and only
parts identical to those specified should be used.

TABLE OF CONTENTS
Page
SPECIFICATIONS ................................................................................................................................................. 2
EXTERNAL DIMENSIONS ..................................................................................................................................... 4
WIRING DIAGRAMS ............................................................................................................................................. 5
ELECTRICAL PARTS ............................................................................................................................................ 7
BLOCK DIAGRAM ..................................................................................................................................................8
MICROCOMPUTER CONTROL SYSTEM .......................................................................................................... 10
FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES ................................................................... 21
BREAKDOWN DIAGNOSIS PROCEDURE ........................................................................................................ 28
REFRIGERATION CYCLE ................................................................................................................................. 33
PERFORMANCE CURVES ................................................................................................................................ 36
DISASSEMBLING PROCEDURE ....................................................................................................................... 38
OPTION ............................................................................................................................................................... 47
REPLACEMENT PARTS LIST ............................................................................................................................. 51

SHARP CORPORATION
1
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

SPECIFICATIONS
ITEMS INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT
AH-X075E AU-X075E AH-X095E AU-X095E
Cooling capacity kW 2.1(0.9 - 2.6) 2.6(0.9 - 2.9)
Moisture removal Liters/h 0.8 1.0
Electrical data
Phase – Single
Rated frequency Hz 50
Rated voltage range V 198 to 264
Rated voltage V 220 - 240
Rated current Cool A 3.7 - 3.4 4.9 - 4.5
Rated input Cool W 800 1070
Power factor Cool % 99 - 99 99 - 99
Compressor Type Hermetically sealed rotary type
Model HV141X1-S12E3
Oil charge 370cc (SUNISO 4GSD)
Refrigerant system Evaporator Bare tube type Grooved tube type
Condenser Corrugate Fin and Grooved tube type
Control Capillary tube
Refrigerant volume 630g 670g
Noise level High dB(A) 35 43 36 43
(at cooling) Med. dB(A) 31 – 32 –
Low dB(A) 28 – 28 –
Fan system
Drive Direct drive
Air flow quantity High m3/min. 6.7 24.3 7.0 24.3
3
(at cooling) Med. m /min. 4.9 – 5.3 –
Low m3/min. 4.3 – 4.4 –
Fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Connections
Refrigerant coupling Flare type
Refrigerant tube size Gas, Liquid 3/8", 1/4"
Refrigerant pipe sets No. AZ-24H5E; 5m(16.4ft), AZ-24H7E; 7m(23ft)
Drain piping mm(Inches) O.D ø 18(45/64)
Others
Safety device Compressor: Thermal protector Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters Polypropylene net (Washable)
Net dimensions Width mm 750(29-17/32) 698(27-15/32) 750(29-17/32) 698(27-15/32)
Height mm 270(10-5/8) 530(20-7/8) 270(10-5/8) 530(20-7/8)
Depth mm 183(7-7/32) 250(9-27/32) 183(7-7/32) 250(9-27/32)
Net weight kg 8 28 8 28
Note: The condition of star ( ) marked item are ‘IEC 378’.

2
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

ITEMS INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT


AY-X075E AE-X075E AY-X095E AE-X095E
Cooling capacity kW 2.1(0.9 - 2.6) 2.6(0.9 - 2.9)
Heatpump kW 3.2(0.9 - 3.6) 3.4(0.9 - 4.0)
Heating capacity
Moisture removal Liters/h 0.8 1.0
Electrical data
Phase – Single
Rated frequency Hz 50
Rated voltage range V 198 to 264
Rated voltage V 220 - 240
Rated current Cool A 3.7 - 3.4 4.9 - 4.5
Heat A 5.0 - 4.5 5.5 - 5.0
Rated input Cool W 800 1070
Heat W 1080 1200
Power factor Cool % 99 - 99 99 - 99
Heat % 99 - 99 99 - 99
Compressor Type Hermetically sealed rotary type
Model HV141X1-S12E3
Oil charge 370cc (SUNISO 4GSD)
Refrigerant system Evaporator Bare tube type Grooved tube type
Condenser Corrugate Fin and Grooved tube type
Control Capillary tube
Refrigerant volume 630g 670g
De-lce system Micro computer controled reverse sysetm
Noise level High dB(A) 35 43 36 43
(at cooling) Med. dB(A) 31 – 32 –
Low dB(A) 28 – 28 –
Fan system
Drive Direct drive
3
Air flow quantity High m /min. 6.7 24.3 7.0 24.3
(at cooling) Med. m3/min. 4.9 – 5.3 –
Low m3/min. 4.3 – 4.4 –
Fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Connections
Refrigerant coupling Flare type
Refrigerant tube size Gas, Liquid 3/8", 1/4"
Refrigerant pipe sets No. AZ-24H5E; 5m(16.4ft), AZ-24H7E; 7m(23ft)
Drain piping mm(Inches) O.D ø 18(45/64)
Others
Safety device Compressor: Thermal protector Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters Polypropylene net (Washable)
Net dimensions Width mm 750(29-17/32) 698(27-15/32) 750(29-17/32) 698(27-15/32)
Height mm 270(10-5/8) 530(20-7/8) 270(10-5/8) 530(20-7/8)
Depth mm 183(7-7/32) 250(9-27/32) 183(7-7/32) 250(9-27/32)
Net weight kg 8 28 8 28
Note: The condition of star ( ) marked item are ‘IEC 378’.
3
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

EXTERNAL DIMENSIONS

AY-F22SE

750 183

270
63 18

800
162

Length unit (mm) Power supply cord


Right : 1.8m
Left : 1.1m

Figure E-1. INDOOR UNIT

AU-F22SEY
304
280
250

5hole
10.5
38
58
470 129 Length (mm)

698 185 35
515

530

135
85
15

Figure E-2. OUTDOOR UNIT


4
IN DOOR UNIT
CAUTION The voltage is high at C1 (electronic capacitor) on outdoor unit. BK : BLACK RE : RED
TERMINAL BOARD TERMINAL BOARD TERMINAL
For mentenance, discharge at C1 to prevent electric shock. BL : BLUE WH : WHITE
BOARD
BR : BROWN OR : ORANGE
In case that WPE2 (protecter) has been fused, the voltage is kept high at C1. GR : GRAY G(Y) : GREEN - YELLOW
GREEN - YELLOW
OUT DOOR UNIT
G(Y)
G(T) COIL1
DIODE RE YE
RY1 COMPRESSOR RELAY T4 L5
BRIDGE + YE
BROWN In Out BROWN BR DB1 POWER FACTOR
N 1 1 L+ WH L– WH MODULE AF1
COM NO C1 +
SINGLE PHASE SA1 L7
WPE1 420V
220-240V T1 ~ YE –
IN+ 1500µF
50Hz FUSE CONTROL BOARD UNIT
BR BR BR ~
OUT+
L 250V T6 T7
GR YE
2.5A T8
– BK

L3
BLUE IN–

COIL
MRY1
BL OUT–
RED L4 GR

5
LOUVER CN3 SERIAL TS
MOTOR NR1 SIGNAL T9
CIRCUIT S
SSR1 WPE2
TR
ROOM TEMP

UNIT TO UNIT CORD


THERMISTOR TH1 CN4
YELLOW C1 CT1
FAN
4 T10 BL
CN7 CN8 WPE3 MOTOR TH2 THERMISTOR
RED PIPE TEMP

L2
5 3 1 CAPACITOR (OR) 3

COIL
TH2-1 FAN MOTOR – +
430V
PIPE TEMP CAPACITOR 1.5 µF 2
TH2 RY1 POWER
THERMISTOR 430V1.5µF RED R.P.M BL
1 TRANSISTOR
WIRING DIAGRAMS

ORANGE TH2-2 C SIGNAL N N T2 MODULE

1 3 5 PM1
DISPLAY CN3
A THERMISTOR
CONTROL CN1 A C RE COMPRESSOR TEMP L6 U V W
M BLUE
BOARD RE FAN R
BLUE BLACK T3 BK
2 2 MOTOR BL RE
M S WH
FAN MOTOR TH1(BK)
BLUE A C BK
BLUE
COMPRESSOR

Figure W-1. Wiring Diagram for AH-X075E and AH-X095E


AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E
AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E

AY-X095E/-X075E

IN DOOR UNIT
TERMINAL CAUTION The voltage is high at C1 (electronic capacitor) on outdoor unit.
TERMINAL BOARD TERMINAL BOARD BOARD
For mentenance, discharge at C1 to prevent electric shock. BK : BLACK RE : RED
BL : BLUE WH : WHITE
In case that WPE2 (protecter) has been fused, the voltage is kept high at C1. BR : BROWN OR : ORANGE
GREEN - YELLOW
GR : GRAY G(Y) : GREEN - YELLOW
OUT DOOR UNIT

G(Y) DIODE RE COIL1


G(Y)
BRIDGE + L5
RY1 COMPRESSOR RELAY T4 POWER FACTOR
PTC1 DB1
BROWN In Out BROWN BR BR BR L+ L– MODULE AF1 C1 +
N COM NO 1 1 SA1
YE
420V
SINGLE PHASE WPE1 BR OUT+ YE
1500µF –
T6 T7 IN+
220-240V ~ ~
50Hz FUSE CONTROL BOARD UNIT T1
T8 YE
L 250V GR
MRY1 – IN– GR
2.5A TS BL

6
L3
BK OUT–

COIL
BLUE L4 L7 T9
CT1
R1 C3
RED C2
LOUVER CN3 SERIAL RY2
MOTOR NR1 SIGNAL
CIRCUIT S WPE3 WPE2
SSR1
TR
ROOM TEMP RY3

UNIT TO UNIT CORD


THERMISTOR TH1 CN4 CNR2
YELLOW C1 CN8 BL
T10

L2
CN7 CN8 4 – +
RY1

COIL
RED
CNR1
FAN MOTOR TH2 THERMISTOR
PIPE TEMP
TH2-1 FAN MOTOR 5 3 1 3
CAPACITOR (OR) POWER
PIPE TEMP CAPACITOR 430V1.5µF
TH2 2 TRANSISTOR
THERMISTOR 430V1.5µF RED R.P.M BL
ORANGE 1 3 5 3 1 MODULE
TH2-2 C SIGNAL N 1 PM1
N CN3 CN4
T2 RE BK BL RE U V W
DISPLAY C 2 1 L6
A BL
CONTROL CN1 A M THERMISTOR
BLUE
BOARD BLACK RE COMPRESSOR TEMP
BLUE R
2 2 M RE WH BK
FAN MOTOR T3 A
BLUE S
TH1(BK)
BLUE FAN MOTOR ROTARY VALVE COIL C

COMPRESSOR

Figure W-2. Wiring Diagram for AY-X075E and AY-X095E


AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

ELECTRICAL PARTS

For Model AH-X075E/X095E and AU-A075E/X095E


DESCRIPTION MODEL REMARKS SITE
Indoor fan motor ML-A486 220 - 240V, 50Hz AH
Indoor fan motor capacitor – 430V, 1.5µF AH
Transformer – Primary; AC 230V, 50Hz AH
Secondary; AC14.6V, 50Hz
Fuse – 250V, 2.5A AH
Compressor HV141X1S12E3 3-PHASE Induction motor AU
Outdoor fan motor ML-A485 220 - 240V, 50Hz AU
Outdoor fan motor capacitor – 430V, 1.5µF AU
WPE1 – QFS-AA047JBE0(13A, 250V) AU
WPE2 – QFS-AA040JBE0(10A, 250V) AU
WPE3 – QFS-AA046JBE0(3A, 250V) AU

For Model AY-X075E/X095E and AE-A075E/X095E


DESCRIPTION MODEL REMARKS SITE
Indoor fan motor ML-A486 220 - 240V, 50Hz AY
Indoor fan motor capacitor – 430V, 1.5µF AY
Transformer – Primary; AC 230V, 50Hz AY
Secondary; AC14.6V, 50Hz
Fuse – 250V, 2.5A AY
Compressor HV141X1S12E3 3-PHASE Induction motor AE
Outdoor fan motor ML-A485 220 - 240V, 50Hz AE
Outdoor fan motor capacitor – 430V, 1.5µF AE
WPE1 – QFS-AA047JBE0(13A, 250V) AE
WPE2 – QFS-AA040JBE0(10A, 250V) AE
WPE3 – QFS-AA046JBE0(3A, 250V) AE

7
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

BLOCK DIAGRAMS

INDOOR UNIT for AH-X075E/X095E and AY-X075E/X095E

2.5 A
DC power supply circuit AC power
FUSE
Fan motor phase control circuit Room fan motor

Rotation pulse input circuit Fan motor pulse detect


AC clock circuit

Flow direction control


Louvre motor drive circuit
(louvre motor)
Remote controller signal Wireless remote control
reception circuit operation
Buzzer drive circuit Audible operation confirmation
CPU reset circuit
CPU oscillator circuit
CPU Room temp. detect circuit Room temp. thermistor
Heat exchanger pipe thermo circuit Heat exchanger pipe thermistor
Compensation circuit/ Blower temperature,
select circuit fan speed, model select
Compensation circuit Outdoor ratings
Switchover circuit Wireless, preheat
Unit-unit
Serial I/O circuit Indoor/outdoor control signal I/O wiring (AC
power and
Outdoor unit power supply serial
Compressor relay drive circuit
on/off control signals)
LED drive circuit LED display
Auto restart circuit (option)
Test run circuit Test run (forced operation)
Auxiliary mode Auxiliary mode button ON/OFF
Self diagnostics,
fault diagnosis
Power on circuit

8
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

OUTDOOR UNIT for AU-X075E/X095E and AE-X075E/X095E

13 A
Power supply protection Unit-unit
Smoothing Active filter Filter
circuit (built wiring (AC
circuit circuit circuit
into IPM) power and
serial
signals)

CPU oscillator circuit


3A
protection

Outdoor fan relay drive Outdoor fan


circuit
4-way valve relay drive 4-way valve (except for
circuit the AU-X095E/X075E)
Power transistor module Power
drive circuit transistor module 10 A protection

CPU Serial I/O circuit


CPU reset circuit Compressor

DC overcurrent detection
circuit
AC overcurrent detection Current transformer
circuit
Compressor thermo circuit Compressor thermistor

Heat exchanger pipe Heat exchanger pipe


thermo circuit thermistor
Heat exchanger pipe
thermistor(option)
Winter kit circuit (option)
Outdoor temperature
thermistor(option)
LED drive circuit LED

Test mode circuit

9
TRANSFORMER TERMINAL BOARD 3P
FU1
BROWN
2.5A–250V L
12V AC220 – 240V
AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E

5V R3 C2
2W 270 IN N
250V NR1
OUT IN FC1
AC
IC3 TR RY1
D1 D2 0.22µ C21
GND NF1 0.01µ
+ ZD1 + + 250V AC OUT
C6 _ _ _
10V C4 25V C3 BLUE
AY-X095E// AY-X075E 0.1µ 25V S201D01 TERMINAL BOARD 4P
100µ D3 D4 SSR1 BROWN
1000µ RED
R4 R5 1 1 1
5V 5V 33K 33K 13 11
X24C01P
MODEL 4 NC 1 8 5V A N
C80 CNR1 BLACK BLUE
COOL / HOT NC 2 7 NC 25V 3 5
MODEL 3 IC80 R6 C1 S 2
NC 3 6 0.1µ RED
JP28 3.3K 1.5µ
Q1 BLUE
4 5 430V AC 5 6 R40
MODEL 2 FAN
C8 3 C7
5V 1 2 CN7 MOTOR R41
MODEL 1 16V 50V
12V GREEN / YELLOW
0.01µ 1000P
R80 R42
5V SW1 5V YELLOW
6.8k 1 3
AUX R43
(TEST RUN) BROWN
R81 C16 2 4
1K 16V R21 R22 R44 2W 680~ 5
R12 1.2K
5V 0.01µ 3.3K GRAY
10K
3 2
D5
RECEIVER UNIT
RPM CN8 CN701 D7
R20
5V 5V

32
30
29
28
27
26
25
24
23 NC
22 NC
21
20
5V 33K
+ C104 1 1
R9
R25
_ 10U33µ 5V 4.7K 1
10K 4
2 2

TEST
OSCOUT 31 NC
OSCIN
P60
P61
P62
GND
P63
P64
P65
P66
KH
P40
OUT R18 2.7K
C102 C9 MODEL 5 D6
0.1µ 25U 50V 95/75 C20
3 3 33 P27 P41 19 MODEL 6 250V AC 2 3
(RED) 1000P JP27 C15 R26
34 P26 P42 18 R19 0.01µ
LED101 MODEL 7 16V 2W PC1
OPERATION LED 4 4 4.7K
35 P25 P43 17 0.01µ 11K
R10 680 WIRELESS + C18 R23 4 1
LED102 R27 _ 35V 100K
TIMER LED 5 5 36 P24 P44 16 PREHEAT R24
5V 2W 100µ C19
R11 330 ZD2
(YELLOW) 37 P23 P45 15 11K 50V
CN101 CN1 22K
38 P22 P46 14 R17 3 2
+ C13 0.047µ
39 P21 F 13 10K _ 16V PC2
5V Q3 10µ
40 P20 RESET 12
SM 8313 C14 2 3
HA 41 K1 CK1 11 1
OSC 8MHz 25V D8
JP

10
42 P17 CK2 10 0.1µ 12V
43 P16 AGND 9 1 3
NC 44 P15 P30 8 BZ
5V
POWER ON NC 45 P14 P31 7 R30 R16
IC 1 2 R31
NC 46 P13 P32 6 1.8K
RATING f 1
12V 12V 47 P12 P33 5 Q2
R33 R32
48 P11 P50 4 RATING f 2 3 2
2 49 P10 P51 3 1
RY1
SSR1 COMPRESSOR 50 P07 P52 2
RELAY JP25
3 51 P06 P53 1
R1 R35 R34 TH2–2
TH2
1/2W FAN L
470 + C12 PIPE TEMP ORANNGE
CN301 CN3 R36 R15
R37 10.0KF _ 16V 5V
RED FAN M 10µ
1 5 12V 12V TH2–1

52 P05
53 P04
58 GND
59 VDD
60 VR
61 P57
62 P56
63 P55
64 P54
R39 R38
ORANGE TH1
2 4 FAN H 2 2

NC 54 P03
NC 55 P02
NC 56 P01
NC 57 P00
+ C11 ROOM TEMP
YELLOW R14
3 3 _ 16V
5V 10.0KF 1 1
10µ
PINK CN4 CN401
4 2
YELLOW
MICROCOMPUTER CONTROL SYSTEM

C17 +
BLUE TEST
5 1 IC2 10V _ C10 R13
100µ 25V 10K
(LOUVER MOTOR)
0.1µ

MODEL SELECT JUMPER WIRE


JUMPER WIRE MODEL 3 JUMPER WIRE MODEL 6
JP28 JP27
AY-X095E NO NO
AY-X075E NO YES
AH-X095E YES NO
AH-X075E YES YES

Figure L-1. Electronic Control Circuit Diagram for AH-X075E/X095E and AY-X075E/X095E
L1
PM1 (POWER TRANSISTOR MODULE)
WHITE WHITE
GREEN/YELLOW
RED L5
12 11 10 9 8 7 6 5 4 3 2 1 CN2
L+ L– AF1 (POWER FACTOR MODULE)
+ DB1

OUT+ COMPRESSOR
RED T3 4700p R2 IN+ YELLOW YELLOW + V
2 2 1
C5 T5 BLUE ~ ~ RED
1M
N L3 L2
BLUE T2
C8 + U
PTC1 WHITE
BROWN BROWN C1 V
1µ 42 0V
C7
WPE1 15 00µ W
BROWN 1µ BROWN – W
T1 (250V 13A) C6 OUT– GRAY V
1 T6 T7 BLUE – BLACK
4700p BLACK L4 IN–
GRAY T8 T10
TERMINAL BOARD CN1 4 3 2 1
SA1 L7 L6
T9
R1
NR1
GREEN/YELLOW C2 1/2W C3
T4 CT1 MRY1
1µ 560K 0.1µ
5V 4 3 2 1 CN1

NR2 WPE3 WPE2


D1 R4 D2 R6 10K (250V 10A)
(250V 3A) R3 1.0KF
2.7KF + R5 5V
10.0KF C21 MODEL SWITCH
T11 C20
FOR WINTER 1000P R46 AU–X095E…R46 (1.0K¶ )
KIT 220µ AU–X075E…R46 (4.7K¶ )
5V
10v 5V
OUT DOOR FAN R7 330K
R47 C22
C11 430V 1.5µ 0.1µ
5 THERMISTOR 10K
TH1 +
1 10K X2 5V
3 COMPRESSOR C23
2 100µ 10V
RY1 TH2 R11
3 5V
LED1
1 4 1 VRF VDD 64 R31 2.2K
THERMISTOR R12 2 P5 • 7 P0 • 0 63
CN3 CN8 3 P5 • 6 P0 • 1 62 R33
4 P5 • 5 P0 • 2 61 R34
CNR1 10K
+ + 5 P5 • 4 P0 • 3 60 R36 10K 10K
6 P5 • 3 P0 • 4 59
R9 R10

11
C28 C30 C31 7 P5 • 2 P0 • 5 58
C27
10µ X2 8 P5 • 1 P0 • 6 57 5V R35 10K TEST POINT
6.8KF X2
16V 1000p X2 9 P5 • 0 P0 • 7 56 R50 4
IN 10K
10 AGND P1 • 0 55 3 5V
5V OUT
11 RESET P1 • 1 54 2
IC3 12 CK1 P1 • 2 53 5V 1
R14 (AF ARM)
1 2 3 13 CK2 P1 • 3 52
1M 1
3 AF ERROR H R27 CN10 (WINTER KIT)
SM8320

14 TEST1 P1 • 4 51
15 STP P1 • 5 50 NORMALLY L 10K
+ a 16 P4 • 6 P1 • 6 49
5V OSC1
C35 C25 17 P4 • 5 P1 • 7 48 AF ON H
D6 0.1µ PC1 PC817 18 P4 • 4 P2 • 0 47 (AF CONT)
1µ OFF L
2 19 P4 • 3 P2 • 1 46 5V
1 4 20 P4 • 2 P2 • 2 45 Q6
1 21 P4 • 1 P2 • 3 44 UNPACKAGED 13V
C36
22 P4 • 0 P2 • 4 43
4700p 2 3 10K RUNNING FREQUENCY
2 23 P3 • 7 P2 • 5 42
R20 3.3K R18 24 P3 • 6 P2 • 6 41 CHECK (1PM) 5V
R41 R42 R43 C34
(SERIAL) 4 1 4.7K 25 P3 • 5 P2 • 7 40 f 330¶ X6
1000p R15
26 P3 • 4 PWM0 39 6
R19 R21 2W 68¶
R44 R45 27 P3 • 3 PWM1 38 5
56K R22 IC2
3 2 D4 28 P3 • 2 PWM2 37 4
13V R23 5V
PC2 PC853H R16 820¶ RY1 29 P3 • 1 PWM3 36 3 OUT 7805 IN
2W 680¶ X5 R24 3 1
30 P3 • 0 PWM4 35 2
OUT DOOR R25 2 C32
31 Ø PWM5 34 1 0.1µ R28
R26 GND
D3 Q2 FAN 32 GND TEST2 33 7 10K
8
RY3 MRY1 a
IC1 9
10
AE-X095E AND AE-X075E 11 (1PM ARM) C33
C40
12 0.1µ 1000p
Q1
MAIN RELAY Q5
CN2 (BORD IN TYPE)

Figure L-2. Electronic Control Circuit Diagram for AU-X075E/X095E


AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E
L1
PM1 (POWER TRANSISTOR MODULE)
WHITE WHITE
GREEN/YELLOW
RED L5
12 11 10 9 8 7 6 5 4 3 2 1 CN2
AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E

L+ L– AF1 (POWER FACTOR MODULE)


+ DB1

OUT+ COMPRESSOR
RED T3 4700p R2 IN+ YELLOW YELLOW + V
2 2 1
C5 T5 BLUE ~ ~ RED
N 1M
L3 L2
BLUE T2
C8 + U
PTC1 WHITE
BROWN BROWN C1 V
1µ 42 0V
C7
WPE1 15 00µ W
BROWN 1µ BROWN – W
T1 (250V 13A) C6 OUT– GRAY V
1 T6 T7 BLUE – BLACK
4700p BLACK L4 IN–
GRAY T8 T10
TERMINAL BOARD CN1 4 3 2 1
SA1 L7 L6
T9
R1
NR1
GREEN/YELLOW C2 1/2W C3
T4 CT1 MRY1
1µ 560K 0.1µ
5V 4 3 2 1 CN1

NR2 WPE3 WPE2


D1 R4 D2 R6 10K (250V 10A)
(250V 3A) R3 1.0KF
2.7KF + R5 5V
10.0KF C21 MODEL SWITCH
T11 C20
FOR WINTER 1000P R46 AE–X095E…R46 (SHORT)
KIT 220µ AE–X075E…R46 (2.2K¶ )
5V
10v 5V
OUT DOOR FAN R7 330K
R47 C22
C11 430V 1.5µ 0.1µ
5 THERMISTOR 10K
TH1 +
1 10K X2 5V
3 COMPRESSOR C23
2 100µ 10V
RY1 TH2 R11
3 5V
LED1
1 4 1 VRF VDD 64 R31 2.2K
THERMISTOR R12 2 P5 • 7 P0 • 0 63
CN3 CN8 3 P5 • 6 P0 • 1 62 R33
4 P5 • 5 P0 • 2 61 R34
CNR1 10K
+ + 5 P5 • 4 P0 • 3 60 R36 10K 10K
6 P5 • 3 P0 • 4 59
R9 R10 C28 C30 C31 7 P5 • 2 P0 • 5 58
C27
10µ X2 8 P5 • 1 P0 • 6 57 5V R35 10K TEST POINT

12
6.8KF X2
16V 1000p X2 9 P5 • 0 P0 • 7 56 R50 4
IN 10K
10 AGND P1 • 0 55 3 5V
5V OUT
11 RESET P1 • 1 54 2
IC3 12 CK1 P1 • 2 53 5V 1
R14 (AF ARM)
1 2 3 13 CK2 P1 • 3 52
1M 1 3 AF ERROR H R27 CN10 (WINTER KIT)
SM8320

14 TEST1 P1 • 4 51
15 STP P1 • 5 50 NORMALLY L 10K
+ a 16 P4 • 6 P1 • 6 49
5V OSC1
CNR2 C35 C25 17 P4 • 5 P1 • 7 48 AF ON H
3 D6 0.1µ PC1 PC817 18 P4 • 4 P2 • 0 47 (AF CONT)
D7 1µ OFF L
2 19 P4 • 3 P2 • 1 46 5V
1 4 20 P4 • 2 P2 • 2 45 Q6
1 1 21 P4 • 1 P2 • 3 44 UNPACKAGED 13V
C36
RY2 22 P4 • 0 P2 • 4 43
CN4 4700p 2 3 10K RUNNING FREQUENCY
RY3 2 23 P3 • 7 P2 • 5 42
D8 R18 CHECK 5V
R20 3.3K C34 24 P3 • 6 P2 • 6 41 (1PM)
R41 R42 R43
(SERIAL) 4 1 4.7K 25 P3 • 5 P2 • 7 40 f 330¶ X6
1000p R15
26 P3 • 4 PWM0 39 6
R19 R21 2W 68¶
R44 R45 27 P3 • 3 PWM1 38 5
56K R22 IC2
3 2 D4 28 P3 • 2 PWM2 37 4
13V R23 5V
PC2 PC853H R16 820¶ RY1 29 P3 • 1 PWM3 36 3 OUT 7805 IN
2W 680¶ X5 R24 3 1
30 P3 • 0 PWM4 35 2
OUT DOOR R25 2 C32
31 Ø PWM5 34 1 0.1µ R28
R26 GND
D3 Q2 FAN 32 GND TEST2 33 7 10K
8
RY2 RY3 MRY1 a
IC1 9
10
AE-X095E AND AE-X075E D5 D10 11 (1PM ARM) C33
C40
12 0.1µ 1000p
Q1
MAIN RELAY Q5
CN2 (BORD IN TYPE)

Q3 Q4

Figure L-3. Electronic Control Circuit Diagram for AE-X075E/X095E


AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

TO 4 POLES FROM FROM 4 POLES TO 4 POLES


TERMINAL TERMINAL TERMINAL TERMINAL FROM
BOARD " 2 " BOARD " L " BOARD " 1 " BOARD " N " FAN MOTOR

2.5 A 250 V DIP


DSGY A636JBK0
TRANSFORMER TR RY1
QPWBFA812JBE0

FU 1
IN

C2
A
BLUE FAN MOTOR
CN7
SECONDARY

PRIMARY

OUT
5

FAN MOTOR CAPACITOR


JP1 3
NR1 C1
1

C21
C3
VA JP2

95 Y X 0 9 5 E
JP4

C4
DIP
D6
R44

R43

R42

R41

R40
D1

D2
D3

D4

NF1
IN OUT
R26 CNR1
IC3 S
R5
RED
R4 FROM
- 24 V 15 9 FAN MOTOR
C20 C19
R3 ZD1 R23
SSR1
GND R25
ZD2
D7

R27

C6 C5 2 1 4 3 2
R1 7
THERMISTOR

R.P.M SIGNAL
JP13
PIPE TEMP

PC1
TH1

JP5
R.P.M
RC2

C16
R20
R21

R22

C18
D5

JP6
TH2

3 4 1 2
5V

JP7
JP15
Q1
C7

CN8
R24
JP14

TH2-1
R6 JP10
3

AC CLOCK 1POWER ON
R18
CN401

4
C8

AUX.
WIRE LESS JP11

C JP12

SW1

TH2-2
1

TIMER
R12
LED102

80

(YELLOW) CN-4 5 8
JP27
JP8

CN101 GND
C15

JP16
R19

R80 20 R81 32
JP17
JP18 R9
JP9 19 33
JP19
3

C13
ROOM TEMP THERMISTOR

PREHEAT
C9
TH1

Q2

(RED) R10 BZ
3

TION C14
R11 12 V
R17

LED101 OPERA
C101

D8

R16
JP20

DISPLAY CN1
Q3

OSC
LOUVER MOTOR
16
1
1

IC1
JP21

51
5
R32 R31

R33
R39

R36 R37
R34 R35

1
CN3

C17 64 C10 52
R39

R38

JP17
FREQUENCY

1
JP21

C102
JP25

JP23
RATING

RECEIVER UNIT C12 C11 R13


COOL

R15 R14 IC2 TEST


M
H

HEAT
FROM
LOUVER
MOTOR

Figure L-4 Printed Wiring Board for AH-X075E

13
AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E

(OPTION) FROM FROM FROM FROM


FROM DIODE BRIDGE PTC1 DIODE BRIDGE EARTH
WINTER KIT DB1 " " DB1 " " & PTC1 (BULKHEAD)

FROM
TERMINAL
BOARD " N "
FROM
TERMINAL
BOARD " N "

WPE3
(QFS-AA026JBE0)
WPE1 (QFS-AA047JBE0)

FROM
TERMINAL
AU-X075E BOARD " 1 "
FROM
DSGY-A645JBK0
ELECTROLYTIC QPWBFA227JBE0 FROM

14
CAPACITOR TERMINAL
C1 " + " BOARD " 2 "
R26

30 25 20 15 10 5 1
FROM
ELECTROLYTIC
CAPACITOR

Figure L-5 Printed Wiring Board for AU-X075E


C1 " - "

35 40 45 50 55 60

FROM
POWER
TRANSISTOR
MODULE PM1 " - "
WPE2 (QFS-AA040JBE0)

TO
POWER (OPTION) FROM
TRANSISTOR FROM THERMISTOR
MODULE WINTER KIT
PM1 CN2
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

TO FROM FROM TO
TERMINAL TERMINAL TERMINAL TERMINAL FROM
FROM
BOARD " 2 " BOARD " L " BOARD " 1 " BOARD " N " FAN MOTOR
FAN MOTOR

2.5 A 250 V DIP


DSGY A641JBK0
TRANSFORMER TR RY1
QPWBFA820JBE0

FU 1
IN

C2
A
BLUE FAN MOTOR
CN7
SECONDARY

PRIMARY

OUT
5

FAN MOTOR CAPACITOR


JP1 3
NR1 C1
1

C21
C3
VA JP2

95 H X 0 9 5 E
JP4

C4
DIP
D6
R44

R43

R42

R41

R40
D1

D2
D3

D4

NF1
IN OUT
R26 CNR1
IC3 S
R5
RED
R4 FROM
- 24 V 15 9 FAN MOTOR
C20 C19
R3 ZD1 R23
SSR1
GND R25
ZD2
D7

R27

C6 C5 2 1 4 3 2
R1 7
THERMISTOR

R.P.M SIGNAL
JP13
PIPE TEMP

PC1
TH1

JP5
R.P.M
RC2

C16
R20
R21

R22

C18
D5

JP6
TH2

3
3 4 1 2
5V

JP7
JP15
Q1
C7

CN8
R24
JP14

TH2-1
R6 JP10
3

AC CLOCK 1POWER ON
R18
CN401

4
C8

AUX.
WIRE LESS JP11

C JP12

SW1

TH2-2
1

TIMER
R12
LED102

80

(YELLOW) CN-4 5 8
JP27
JP8

CN101 GND
C15

JP16
R19

R80 20 R81 32
JP17
JP18 R9
JP9 19 33
JP19
3

C13
ROOM TEMP THERMISTOR

PREHEAT
C9
TH1

Q2

(RED) R10 BZ
3

TION C14
R11 12 V
R17

LED101 OPERA
C101

D8

R16
JP20

DISPLAY CN1
Q3

OSC
LOUVER MOTOR
16
1
1

IC1
JP21

51
5
R30 R31

R36 R37
R34 R35

1
CN3

C17 64 C10 52
R38

JP17
FREQUENCY

JP29

1
JP21

C102
JP25
H JP30

JP23
RATING

RECEIVER UNIT C12 C11 R13


COOL

R15 R14 IC2 TEST


M
L

FROM
LOUVER
MOTOR

Figure L-6 Printed Wiring Board for AH-X095E

15
AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E

(OPTION) FROM FROM FROM FROM


FROM DIODE BRIDGE PTC1 DIODE BRIDGE EARTH
WINTER KIT DB1 " " DB1 " " & PTC1 (BULKHEAD)

FROM
TERMINAL
BOARD " N "
FROM
TERMINAL
BOARD " N "

WPE3
(QFS-AA026JBE0)
WPE1 (QFS-AA047JBE0)

FROM
TERMINAL
AU-X095E BOARD " 1 "
FROM
DSGY-A639JBK0
ELECTROLYTIC QPWBFA887JBE0 FROM

16
CAPACITOR TERMINAL
C1 " + " BOARD " 2 "
R26

30 25 20 15 10 5 1
FROM
ELECTROLYTIC
CAPACITOR

Figure L-7 Printed Wiring Board for AU-X095E


C1 " - "

35 40 45 50 55 60

FROM
POWER
TRANSISTOR
MODULE PM1 " - "
WPE2 (QFS-AA040JBE0)

TO
POWER (OPTION) FROM
TRANSISTOR FROM THERMISTOR
MODULE WINTER KIT
PM1 CN2
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

TO 4 POLES FROM FROM 4 POLES TO 4 POLES


TERMINAL TERMINAL TERMINAL TERMINAL FROM
BOARD " 2 " BOARD " L " BOARD " 1 " BOARD " N " FAN MOTOR

2.5 A 250 V DIP


DSGY A640JBK0
TRANSFORMER TR RY1
QPWBFA819JBE0

FU 1
IN

C2
A
BLUE FAN MOTOR
CN7
SECONDARY

PRIMARY
OUT
5

FAN MOTOR CAPACITOR


JP1 3
NR1 C1
1

C21
C3
VA JP2

95 Y X 0 7 5 E
JP4

C4 D6 DIP
R44

R43

R42

R41

R40
D1

D2
D3

D4

NF1
IN OUT
R26
CNR1
IC3 S
R5
RED
R4 FROM
- 24 V 15 9 FAN MOTOR
C20 C19
R3 ZD1 R23
SSR1
GND R25
ZD2
D7

R27

C6 C5 2 1 4 3 2
R1 7
THERMISTOR

R.P.M SIGNAL
JP13
PIPE TEMP

PC1
TH1

JP5
R.P.M
RC2

C16
R20
R21

R22

C18
D5

JP6
TH2

3
3 4 1 2
5V

JP7
JP15
Q1
C7

CN8
R24
JP14

TH2-1
R6 JP10
3

AC CLOCK 1POWER ON
R18
CN401

4
C8

AUX.
WIRE LESS JP11

C JP12

SW1
TH2-2
1

TIMER
R12
LED102

80

(YELLOW) CN-4 5 8
JP8

CN101 GND
C15

JP16
R19

R80 20 R81 32
JP17
JP18 R9
JP9 19 33
JP19
3

C13
ROOM TEMP THERMISTOR

PREHEAT
C9
TH1

Q2

(RED) R10 BZ
3

TION C14
R11 12 V
R17

LED101 OPERA
C101

D8

R16
JP20

DISPLAY CN1
Q3

OSC
LOUVER MOTOR
16
1
1

IC1
JP21

51
5
R32 R31

R33
R39

R36 R37
R34 R35

1
CN3

C17 64 C10 52
R39

R38

JP17
FREQUENCY

1
JP21

C102
JP25

JP23
RATING

RECEIVER UNIT C12 C11 R13


COOL

R15 R14 IC2 TEST


M
H

HEAT
FROM
LOUVER
MOTOR

Figure L-8 Printed Wiring Board for AY-X075E

17
AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E

(OPTION) FROM FROM FROM FROM


FROM DIODE BRIDGE PTC1 DIODE BRIDGE EARTH
WINTER KIT DB1 " " DB1 " " & PTC1 (BULKHEAD)

FROM
FAN MOTOR
FROM
TERMINAL
FROM BOARD " N "
ROTARY
VALVE WPE3
(QFS-AA026JBE0)
WPE1 (QFS-AA047JBE0)

FROM
TERMINAL
AE-X075E BOARD " 1 "
FROM
ELECTROLYTIC DSGY-A638JBK0
QPWBFA817JBE0 FROM

18
CAPACITOR TERMINAL
C1 " + " BOARD " 2 "
R26

30 25 20 15 10 5 1
FROM
ELECTROLYTIC
CAPACITOR

Figure L-9 Printed Wiring Board for AE-X075E


C1 " "

35 40 45 50 55 60

FROM
POWER
TRANSISTOR
MODULE PM1 " "
WPE2 (QFS-AA040JBE0)

TO
POWER (OPTION) FROM
TRANSISTOR FROM THERMISTOR
MODULE WINTER KIT
PM1 CN2
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

TO 4 POLES FROM FROM 4 POLES TO 4 POLES


TERMINAL TERMINAL TERMINAL TERMINAL FROM
BOARD " 2 " BOARD " L " BOARD " 1 " BOARD " N " FAN MOTOR

2.5 A 250 V DIP


DSGY A636JBK0
TRANSFORMER TR RY1
QPWBFA812JBE0

FU 1
IN

C2
A
BLUE FAN MOTOR
CN7
SECONDARY

PRIMARY
OUT
5

FAN MOTOR CAPACITOR


JP1 3
NR1 C1
1

C21
C3
VA JP2

95 Y X 0 9 5 E
JP4

C4 D6 DIP
R44

R43

R42

R41

R40
D1

D2
D3

D4

NF1
IN OUT
R26
CNR1
IC3 S
R5
RED
R4 FROM
- 24 V 15 9 FAN MOTOR
C20 C19
R3 ZD1 R23
SSR1
GND R25
ZD2
D7

R27

C6 C5 2 1 4 3 2
R1 7
THERMISTOR

R.P.M SIGNAL
JP13
PIPE TEMP

PC1
TH1

JP5
R.P.M
RC2

C16
R20
R21

R22

C18
D5

JP6
TH2

3
3 4 1 2
5V

JP7
JP15
Q1
C7

CN8
R24
JP14

TH2-1
R6 JP10
3

AC CLOCK 1POWER ON
R18
CN401

4
C8

AUX.
WIRE LESS JP11

C JP12

SW1
TH2-2
1

TIMER
R12
LED102

80

(YELLOW) CN-4 5 8
JP27
JP8

CN101 GND
C15

JP16
R19

R80 20 R81 32
JP17
JP18 R9
JP9 19 33
JP19
3

C13
ROOM TEMP THERMISTOR

PREHEAT
C9
TH1

Q2

(RED) R10 BZ
3

TION C14
R11 12 V
R17

LED101 OPERA
C101

D8

R16
JP20

DISPLAY CN1
Q3

OSC
LOUVER MOTOR
16
1
1

IC1
JP21

51
5
R32 R31

R33
R39

R36 R37
R34 R35

1
CN3

C17 64 C10 52
R39

R38

JP17
FREQUENCY

1
JP21

C102
JP25

JP23
RATING

RECEIVER UNIT C12 C11 R13


COOL

R15 R14 IC2 TEST


M
H

HEAT
FROM
LOUVER
MOTOR

Figure L-10 Printed Wiring Board for AY-X075E

19
AU-X075E/X095E
AH-X075E/X095E

AE-X075E/X095E
AY-X075E/X095E

(OPTION) FROM FROM FROM FROM


FROM DIODE BRIDGE PTC1 DIODE BRIDGE EARTH
WINTER KIT DB1 " " DB1 " " & PTC1 (BULKHEAD)

FROM
FAN MOTOR
FROM
TERMINAL
FROM BOARD " N "
ROTARY
VALVE
WPE3
(QFS-AA026JBE0)
WPE1 (QFS-AA047JBE0)

FROM
TERMINAL
AE-X095E BOARD " 1 "
FROM
ELECTROLYTIC DSGY-A632JBK0
QPWFBA806JBE0 FROM

20
CAPACITOR TERMINAL
C1 " + " BOARD " 2 "
R26

30 25 20 15 10 5 1
FROM
ELECTROLYTIC
CAPACITOR
C1 " "

Figure L-11 Printed Wiring Board for AE-X095E


35 40 45 50 55 60

FROM
POWER
TRANSISTOR
MODULE PM1 " " WPE2 (QFS-AA040JBE0)

TO
POWER (OPTION) FROM
TRANSISTOR FROM THERMISTOR
MODULE WINTER KIT
PM1 CN2
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

FUNCTIONS
b. Initial control
AH-X075E/X095E are not provided with the
The initial frequency is determined as shown in the
heating function.
tables below based on the difference between the
temperature adjustment setting at the beginning of
operation and the room temperature.
1. INDOOR UNIT After operation begins, normal control is performed
1-1 Temperature Adjustment and therefore the correspondences in the tables
a. Normal control below will not hold.
Proportional control (P control) Cooling Heating
Room Frequency Room Frequency
When the temperature zone changes, this control temp. Code temp. Code
changes the frequency by one rank to move closer zone zone
to the set value. c 9 k OFF
d 8 (Hot keep fan)
e 7 j 1
Integral control (I control) f 5 i 1
When the temperature zone has set time in the g 3 h 2
same zone, this control changes the frequency by h 2 g 3
i 1 f 4
one rank to move closer to the set value. (Excluding j OFF e 5
the h zone.) d 6
c 8
Dry b A
Room Frequency a B
Cooling temp. Code z C
c zone
+1.33
d e 4
+1.00
e f 3
+0.66
f g 2
7
+0.33
g h 1
SET VALUE
h i OFF
-0.33
i
-0.66
j
c. Temperature adjustment
The temperature adjustment range is changed by
changing the operating mode with the operation
switch.

Heating (1) Heating


k If the room temperature is in the z zone when
+1.66
operation begins, proportional/integral control is not
+1.00
j performed, and the machine runs at frequency code
c full power until the h zone is reached. When the h
+0.33
i zone is reached, the frequency changes to the
SET VALUE
h frequency code determined by fuzzy calculation,
g
-0.33 and after that proportional/integral control is
f
-0.66 performed.
e
-1.00
d
-1.33
c
(2) Cooling
-1.66
b
If the room temperature is in the c zone when
-2.00
a operation begins,proportional/integral control is not
-2.33
z performed, and the machine runs at frequency
code 9 power until the h zone is reached. When the
h zone is reached, the frequency changes to the
frequency code determined by fuzzy calculation,
and after thatproportional/integral control is
performed.
Dry
e
(3) Dry
f After operation begins, 2 minutes (running at the h
+1.33 zone) of the room temperature is stored in memory,
+1.00 f
and that becomes the set value.
+0.33 h
MEMORY SET VALUE
(4) Circulation
-1.00 The frequency code 0 is sent to the outdoor
i
machine, and only the fan of the indoor machine
runs, the compressor does not run.
21
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

1-2 Indoor fan control COOLING


This control uses the thermistor for the indoor heat
Fan speed : High / Med / Low
exchanger to control cold air blowing prevention, the
indoor fan, and overheating prevention.
11
Temperature of indoor heat exchanger

10
(˚C) H High
9
53 8
G

Fan speed
7
50 6 Med
F 5
47 4
E 3 Low
44 2
D Differential 1
38
C 3˚C OFF
32 OFF 1 2 3 4 5 6 7 8 9
B Frequency cord
26
A
Cold air blowing Fan speed : Automatic
prevention line
11
10
9
(1) Control for indoor overheating prevention 8
If the temperature of the indoor heat exchanger

Fan speed
7
exceeds the overheating prevention line during 6
5
heating due to the operating frequency or the nature 4
of the operation, this control lowers the frequency 3
2
by 4 to 15 Hz. When the temperature goes below 1
the overheating prevention line sixty seconds later, OFF
normal operation is restored. OFF 1 2 3 4 5 6 7 8 9
Frequency cord
Operating Overheating prevention line (°C)
frequency Over 50 Hz 50 to 43 Hz 43 to 37 Hz Below 37 Hz
During normal
operation 54 53 52 51
HEATING
During full
57 56 55 54 Fan speed : High / Med / Low
power operation
12
High
11
D-H
(2) Control for indoor freezing prevention 10
If the temperature of the indoor heat exchanger 9
Med
8
stays below approximately 0°C for four minutes D-H
Fan speed

7
during cooling or dry, this control stops the 6
Low
5
compressor. Over 2˚C the compressor will run 4
D-H

again. 3 C
2
1 B
(3) Control for cold air blowing prevention OFF
When heating begins, this control stops the indoor OFF 1 2 3 4 5 6 7 8 9 A B C
A

fan until the temperature of the indoor heat Frequency cord


exchanger reaches 26°C. It also stops the fan if the
Fan speed : Automatic
temperature goes below 23°C during operation.
12
(4) Indoor fan and operating frequency 11
G, H

The indoor fan has 12 speeds, and changing is 10 F


9 E
done in four stages, "Auto", "High", "Med", and 8
"Low". The relations between the indoor fan speed,
Fan speed

7 D
6
air quantity setting, operating frequency, and indoor 5
heat exchanger are shown in the following charts. 4 C
3
2
1 B
OFF A
OFF 1 2 3 4 5 6 7 8 9 A B C
Frequency cord

22
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

12
1-5 ON-timer
11 Dry The ON-timer is set by pressing the ON-timer button. In
10
order to attain the set temperature at the set time, the
operation starting time is corrected by neuro and fuzzy
9
computing one hour before the set time.
8
Fan speed

7
1-6 OFF-timer
6
The OFF-timer is set by pressing the OFF-timer button.
5 Operation is as follows:
4 e, f zone
g zone
Set temperature
3
2 h zone Cooling By fuzzy computing
i zone
Heating Set the shift up time
1
Cooling setting + 1°C
Final Heating setting - 3°C
0 1 2 3 4
Operating frequency code
Dry Same as above
12 (Final setting + 1°C)
11 Circulation

10 *During Heating
9 High
Timer set time
8
Fan speed

7
6 Med
5
3°C Room
4
1 temperature
3 Low
hour
2
1

Timer operation starts Stops


0
Operating frequency code *During Cooling / Dry
1-3 Hot keep Timer set time
If the room temperature is in the j or k zone during
heating, the compressor is turned on and off to prevent
overheating. Room
temperature
Zone Compressor intermittent time Fan 1°C
J 3 min. on - 3 min. off Same as Compressor 1
hour
After "3 min. on - 3 min.off"
is repeated 4 times, the
Timer operation starts Stops
compressor goes off, and
K 3 min. on - 8 min. off only the fan continues to
repeat “3 min. on - 8
1-7 Swing louvre
min.off”.
The louvre is moved by a stepping motor to perform
swing and fixing in the set position.
If the "FLOW DIRECTION" button is prossed during
swing, it will stop. If the "FLOW DIRECTION" button is
The fan goes off 30 seconds after the compressor goes prossed while it is stopped, it will swing.
off.
1-8 Restart control
1-4 Automatic operation Once the compressor stops, this control prevents it from
The operating mode and temperature setting are starting again for 3 minutes. It also prevents starting for
determined by the room temperature and the external 20 seconds immediately following plugging into the
air temperature. power outlet.
External air
0 10 18 31 34 temperature (°C)

Cooling
(25˚C)
26 HeatingHeating Heating Cooling Cooling
Dry
(24˚C) (23˚C) (22˚C) (26˚C) (27˚C)
(Room temperature
- 2°C)
21
Room
The external air temperature is determined by
temperature
detecting the temperature of the outdoor heat
(˚C)
exchanger.

23
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

1-9 One-hour operation (1) It is ON during operation, and when operation is


If this button is pressed when operation is stopped, stopped, goes OFF after a delay of 150 seconds
operation will begin and then stop after 1 hour. (not immediately).
If pressed when it is operating, will stop after one (2) The minimum OFF time of the relay is 30 seconds.
hour.
Air conditioner ON
1-10 Full power operation operation
OFF
Immediately begins cooling or heating at maximum
power and air flow. Full power stops after 1 hour. ON
Compressor
(During heating)
relay OFF
Operates at setting of 32°C.
(During cooling)
Operates at setting of 18°C. 150 sec.
1-11 Preheat It will not go ON again before 30 seconds elapses.
When heating is stopped, supplies a small amount (3) If air conditioner operation is turned on again during
of power to the compressor to make heating start
more quickly. Air conditioner ON ON
Operates when the indoor temperature sensor and operation OFF
external air sensor detect that the room temperature
ON ON
and outdoor heat exchange temperature are low Compressor
(below 18°C and 10°C, respectively). Stops when relay OFF
the compressor chamber temperature rises above
30°C. 150 sec. 30 sec.
Preheat does not operate for 2 hours after heating
is stopped. After that, it goes on for 165 minutes the 150 second delay before the compressor relay
and then stops for 15 minutes, repeatedly. goes off, the compressor relay will stay on.
At least 165 15
120 min min min

Air conditioner ON ON
operation OFF
ON
Compressor
relay
Air conditioner OFF 150 sec.

1-12 Power ON start


If a jumper wire is inserted into the place indicated
power ON on the indoor control board, and the
power plug is inserted. cooling or heating will be
automatically determined by the room temperature
sensor on the main unit, and operation will begin.
1-13 Compressor relay RY6

24
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

AU-X075E/X095E are not provided with the heating function.

2. OUTDOOR UNIT
2-1 Defrost operation
(1) Overview
Defrosting begins during heating if the conditions for compressor operation time and outdoor heat exchanger
temperature are met.
When defrosting begins, the indoor and outdoor fans stop.
Defrosting stops when the temperature of the outdoor heat exchanger goes above approximately 10˚C or defrosting
time exceeds 13 minutes.
Defrost Defrost Defrost
mask time mask time mask time

Heating
begins

Defrosting Defrosting
Max. 13 min. Max. 13 min.
(2) Defrosting conditions
The temperature of the outdoor heat exchanger is detected by a sensor, and if it stays in the preset defrost zone for
approximately 2 minutes, defrosting start is enabled.
If defrosting is enabled when the defrost mask time ends, defrosting is performed. If defrosting is not enabled, the
machine waits until defrosting is enabled.
Defrost mask times and defrost zones are as shown below.
The defrosting zone is an outdoor heat exchanger
Previous Current defrost
temperature of under approximately -4˚C.
defrosting time mask time
First time 40 min.
Second time 0.5 to 1.5 min. 90 min.
and thereafter 1.5 to 3.0 min. 50 min.
3.0 to 5.0 min. 40 min.
5.0 to 7.0 min. 30 min.
7.0 to 9.0 min. 25 min.
Over 9.0 min. 20 min.

(3) During defrosting


When defrosting begins, the compressor stops. Approximately 3 minutes later, the compressor reactivates in the
refrigeration cycle, and the outdoor heat exchanger is defrosted.
Each mode is as follows:
The outdoor fan is stopped
The operating frequency is as shown in the table below
The indoor fan is stopped
Model Frequency Model Frequency
AE-X095E, AU-X095E 95Hz AE-X075E, AU-X075E 90Hz

(4) Defrost stop


When defrosting time exceeds 13 minutes
When the temperature of the outdoor heat exchanger rises above approximately 10˚C
Defrost stop is determined by either of the above conditions, and the compressor is stopped.
At the same time, the outdoor fan go ON. The compressor is reactivated in the heating cycle 3 minutes after it was
stopped, and normal control resumes.

25
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

2-2 Frequency control


(1) AC current peak control
This control lowers the compressor frequency if the AC current exceeds the set values. If the current is below the set
values, the compressor frequency will not be raised above that frequency, as the maximum frequency, for 1 minute.

Model Set value


AE-X095E, AU-X095E During heating Approximately 7.0 A
AE-X075E, AU-X075E During cooling Approximately 6.5 A

(2) Control for prevention of indoor heat exchanger overheating


If the temperature of the indoor heat exchanger exceeds the overheating prevention line during heating due to the
operating frequency or the nature of the operation, the frequency is lowered by approximately 5 to 10 Hz. After that, the
frequency is lowered by approximately 5 to 10 Hz once every 60 seconds. When the temperature of the indoor heat
exchanger goes below the overheating prevention line, the frequency is raised by approximately 5 Hz once every 60
seconds, and normal operation is restored.
If the frequency is lowered to 35 Hz without the temperature of the indoor heat exchanger decreasing and this condition
lasts for 1 minute, the compressor will be stopped.
Overheating prevention line
Operating frequency
Above 50 Hz 50 to 43 Hz 43 to 37 Hz Below 37 Hz
During normal operation 54 53 52 51
During full power operation 57 56 55 54

(3) Control for prevention of outdoor heat exchanger overheating


If the temperature of the outdoor heat exchanger exceeds approximately 57°C during cooling, the operating frequency
is lowered by approximately 5 to 15 Hz. After that, the frequency is lowered by approximately 5 to 10 Hz once every 60
seconds. When the temperature of the outdoor heat exchanger goes below approximately 55˚C, the frequency is raised
by approximately 5 Hz once every 60 seconds, and normal operation is restored.
If the frequency is lowered to 35 Hz without the temperature of the outdoor heat exchanger decreasing and this
condition lasts for 1 minute, the compressor will be stopped.

(4) Control for prevention of discharge overheating


If the discharge temperature exceeds approximately 105°C during compressor operation, the operating frequency is
lowered by approximately 5 Hz. After that, the frequency is lowered by approximately 5 Hz once every 60 seconds.
When the temperature of the outdoor heat exchanger goes below approximately 104˚C, the frequency is raised by
approximately 5 Hz once every 60 seconds, and normal operation is restored.
If the frequency is lowered to 35 Hz without the discharge temperature decreasing and this condition lasts for 1 minute,
the compressor will be stopped.

(5) Control for prevention of indoor heat exchanger freezing


If the temperature of the indoor heat exchanger goes below approximately 5°C during cooling, the operating frequency
is lowered by approximately 5 Hz. After that, the frequency is lowered by approximately 5 Hz once every 60 seconds.
When the temperature of the indoor heat exchanger rises above approximately 5°C, the frequency is raised by
approximately 5 Hz once every 60 seconds, and normal operation is restored.
If the temperature of the indoor heat exchanger goes down to approximately 0°C and this condition continues for 4
minutes, the compressor is stopped. When the temperature rises above approximately 2˚C, normal operation is
restored.

26
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

2-3 Overcurrent protection


(1) Compressor lock detection
If the set value (3.0 A) of AC current is exceeded at 19 to 23 Hz when operation begins, operation is stopped. In this
case, the compressor outdoor fan does not stop, and 170 seconds after operation is stopped, another try will be made.
Three retries are allowed. On the fourth retry, a complete stop request signal is sent to the indoor unit, and the outdoor
unit will remain stopped until reset is performed. At this time, the 3-minute delay for control of the outdoor unit will not
function; therefore, do not cancel by removing the plug and cutting the power.

(2) DC overcurrent detection, AC overcurrent detection


To protect against overcurrent due to sudden changes in load, the compressor is stopped if the set value 30 A DC is
exceeded in the DC section, or the set value 8.5 A AC is exceeded in the AC section. In this case, the outdoor fan does
not stop, and 170 seconds after operation is stopped, another try will be made. Three retries are allowed. On the fourth
retry, a complete stop request signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is
performed. At this time, the 3-minute delay for control of the outdoor unit will not function; therefore, do not cancel by
removing the plug and cutting the power.

2-4 Compressor protector control


If the temperature of the compressor chamber exceeds 114°C, the compressor is stopped. In this case, the outdoor fan
does not stop, and when the compressor chamber temperature decreases to 100°C three minutes after operation is
stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop request signal is sent
to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3-minute delay for
control of the outdoor unit will not function; therefore, do not cancel by removing the plug and cutting the power.

2-5 Power transistor module protector


If the temperature of the chips in the power transistor module exceeds 105 °C, the compressor is stopped. In this case,
the outdoor fan does not stop, and when the temperature of the chips in the power transistor module decreases to 105
°C 170 seconds seconds after operation is stopped, another try will be made. Three retries are allowed. On the fourth
retry, a complete stop request signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is
performed. At this time, the 3-minute delay for control of the outdoor unit will not function; therefore, do not cancel by
removing the plug and cutting the power.

2-6 Power factor module


If a voltage error (over 400 V), current error (over 17 A), or temperature error (over 90°C) is detected in the power factor
module, 170 seconds the compressor is stopped. In this case, the outdoor fan does not stop, and 170 seconds after
operation is stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop request
signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3-
minute delay for control of the outdoor unit will not function; therefore, do not cancel by removing the plug and cutting
the power.

2-7 Serial signals


(1) Serial signals consist of all 96-bit signals.
(2) If the outdoor unit does not receive a serial signal, it will stop approximately 30 seconds later. Note that this is true only
of normal operation; in test mode, it does not stop and operation takes place based on the test mode commands.

2-8 Four-way rotary valve


The four-way rotary valve will not switch when there is a large difference in refrigerant pressure. To make the four-way
rotary valve switch normally, switching is delayed by approximately 3 minutes and the refrigerant pressure difference
is decreased first. Also, the temperature of the indoor heat exchanger at the time of compressor activation and the
temperature 150 minutes after activation are compared, and it is determined whether or not they are suitable for the
operating mode at that time. If they are not suitable, a four-way rotary valve error results and the compressor is
stopped.

27
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES

Operation Self diagnostic


display
NO Function
Description Detection Restart Restart Indoor Outdoor
time condition times
1 Indoor fan Stops operation if no revolution pulse When indoor Operation OFF No limit Yes No
lock signal is input from the indoor fan motor for fan is revolving
one minute.

Indoor fan Stops operation if the revolution pulse


rpm error signal from the indoor fan indicates low
rpm (approximately 300 rpm or less).

2 Indoor Lowers the operating frequency if the During cooling Automatically No limit No No
freezing temperature of the indoor heat exchanger and dry restarts when the
guard goes below 5°C during cooling. Stops the exchange
compressor if the temperature stays below temperature rises
0°C for 4 minutes. above the freezing
prevention
temperature (above
2°C)

3 Indoor Lowers the operating frequency if the During heating Automatically No limit No No
overheating temperature of the indoor heat exchanger restarts when the
control rises above the overheating temperature exchange
during heating. Stops the compressor if the temperature goes
temperature stays above the overheating below the
temperature for 1 minute at 35 Hz or less. overheating
Set values for overheating temperature temperature.
During normal operation: 51°C to 54°C
During full power operation: 54°C to
57°C

@@@@@@@
4 DC Stops the compressor if a current of During Automatically 4 times Yes Yes
overcurrent approximately 30 A or more flows in the compressor restarts after safety
power transistor module. Also stops the operation time (170 seconds)
compressor if the temperature of the
power transistor module is exceeds 105°C.

5 AC Lowers the operating frequency if the During Automatically 4 times Yes Yes
overcurrent compressor AC current exceeds compressor restarts after safety
7 A(X095E) or 6.5A(X075E). operation time (170 seconds)
Stops the compressor if the current
exceeds 7 A at 40 Hz or less.
Stops the compressor if the compressor
AC current exceeds 8.5 A(X095E) or
6.5A(X075E).

6 Compressor Stops the compressor if the compressor Immediately Automatically 4 times Yes Yes
lock AC current exceeds 3 A immediately after after restarts after safety
activating the compressor (at 19 to 23 Hz). compressor time (170 seconds)
activation.

28
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

Operation Self diagnostic


display
NO Function
Description Detection Restart Restart Indoor Outdoor
time condition times
7 Compressor Lowers the operating frequency if the During Automatically No limit No No
overheating temperature of the compressor chamber compressor restarts after safety
control thermistor (TH1) rises above 105°C. operation time (170 seconds)
Stops the compressor if the thermistor
stays above 110°C for 4 minutes, or 1
minute at 35 Hz or less.

8 Compressor Stops the compressor if the compressor During Automatically 4 times Yes Yes
high chamber thermistor is above 114°C. operation restarts when
temperature (Or when TH1 shorts) thermistor (TH1)
error temperature falls
below 100°C
(approximately 30
minutes)

9 Outdoor Lowers the operating frequency if the During Automatically No limit No No


overheating temperature of the outdoor heat exchanger compressor restarts after safety
control rises above 57°C during cooling. Stops the operation time ( (170 seconds)
compressor if the temperature stays above
57°C for 4 minutes, or 1 minute at 35 Hz or
less.

10 Outdoor Stops the compressor if an outdoor When Automatically 4 times Yes Yes
thermistor thermistor (excluding TH1) shorts. compressor is restarts after safety
short activated time (170 seconds)

11 Outdoor Stops the compressor if the circuit of an When Automatically 4 times Yes Yes
thermistor outdoor thermistor breaks. compressor is restarts after safety
open activated time (170 seconds)

12 AC abnormal Stops the compressor if if the operating During Automatically 4 times Yes Yes
current error frequency is above 85 Hz and the compressor restarts after safety
compressor current is below 1.0 A. operation time (170 seconds)

13 Serial signal Turns the compressor relay off if the indoor During Automatically No limit Yes
error unit does not receive a serial signal from operation restarts less than 8
the outdoor unit for 8 minutes. minutes after
operation stops

Stops the compressor if the outdoor unit During Restarts after No limit Yes
does not receive a serial signal from the operation reception of serial
indoor unit for 30 seconds. signal

14 Four-way When the rise and fall in the detected 2 minutes and Does not restart 4 times Yes Yes
valve error temperature of the outdoor heat exchanger 30 seconds
thermistor (TH2) do not agree with the after
operating cycle. compressor
activation

15 Power factor When an power factor module error input During Automatically 4 times Yes Yes
module is detected. compressor restarts after safety
(Active filter) operation time (170 seconds)
error

29
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

30
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

31
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

32
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

REFRIGERANT CYCLE

Indoor unit Evaporator


3

Flare coupling Flare coupling

valve valve

Strainer
s

Outdoor unit
Capillary tube

Silencer

Compressor
4
Condensor
1

2
Accumulator

Figure R-1. Refrigeration Cycle for AH-X075E/X095E

Indoor unit Evaporator


3

Flare coupling Flare coupling

valve valve

Silencer Strainer
s

Outdoor unit
Accumulator Capillary tube
4
1

Heating
Comp-
ressor

Cooling
Coil
Condensor
C
Reverse valve 2

Figure R-2. Refrigeration Cycle for AY-X075E/X095E

33
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

Standard conditions:
AH-X075E / AH-X095E
Indoor side Outdoor side
Dry-bulb Temp. (˚C) Relative Humidity (%) Dry-bulb Temp. (˚C) Relative Humidity (%)
Cooling 27 47 35 40

Temperature at each part and pressure in 3-way valve


AH-X075E AH-X095E
Operation Cool Operation Cool
mode (Max.) Cool mode (Max.) Cool

No. Hz 86 50 settle No. Hz 90 60 settle


1 96˚C 68˚C 1 100˚C 75˚C
2 43˚C 40˚C 2 45˚C 40˚C
3 11˚C 12˚C 3 11˚C 13˚C
4 14˚C 7˚C 4 15˚C 9˚C
3-way valve 3-way valve
pressure 4.4 5.9 pressure 4.5 5.7
(kg/cm2 G) (kg/cm2 G)

Dimension of Capillary tube


AH-X075E AH-X095E
O.D I.D. L O.D I.D. L
Capillary tube ø2.7 ø1.4 700 Capillary tube ø2.7 ø1.5 800

34
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

Standard conditions:
AY-X075E / AY-X095E
Indoor side Outdoor side
Dry-bulb Temp. (˚C) Relative Humidity (%) Dry-bulb Temp. (˚C) Relative Humidity (%)
Cooling 27 47 35 40
Heating 20 7 87

Temperature at each part and pressure in 3-way valve


AY-X075E
Operation Cool Heat
mode (Max.) (Max.) Cool Heat

No. Hz 86 more than 90 50 settle 60 settle


1 96˚C 98˚C 68˚C 55˚C
2 43˚C 1˚C 40˚C 3˚C
3 11˚C 35˚C 12˚C 35˚C
4 14˚C 0˚C 7˚C 2˚C
3-way valve
pressure 4.4 20.0 5.9 14.0
(kg/cm2 G)

AY-X095E
Operation Cool Heat
mode (Max.) (Max.) Cool Heat

No. Hz 90 more than 100 60 settle 60 settle


1 100˚C 100˚C 75˚C 55˚C
2 45˚C 0˚C 40˚C 3˚C
3 11˚C 35˚C 13˚C 35˚C
4 15˚C 0˚C 9˚C 2˚C
3-way valve
pressure 4.5 20.0 5.7 14.0
(kg/cm2 G)

Dimension of Capillary tube


AY-X075E AY-X095E
O.D I.D. L O.D I.D. L
Capillary tube ø2.7 ø1.4 700 Capillary tube ø2.7 ø1.5 800

35
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

PERFORMANCE CURVES

NOTE: 1) Indoor fan speed: Hi


2) Vertical adjustment louver "45˚", Horizontal adjustment louver "front"
3) Indoor air temp. : Colling 27˚C

(Running frequency: 68HZ) (Running frequency: 88Hz)

1200 1200
Input(W)

Input(W)
1000 1000

800 800

600 600

Outlet air temp.(˚C)

Outlet air temp.(˚C)


14 14

12 12

10 10
Cooling capacity(kW)

Cooling capacity(kW)
2.6 2.8

2.4 2.6

2.2 2.4

2.0 2.2

25 30 35 40 25 30 35 40
Outside air temp.(˚C) Outside air temp.(˚C)

Figure P-1. At Cooling for AH-X075E Figure P-2. At Cooling for AH-X095E

36
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

NOTE: 1) Indoor fan speed: Hi


2) Vertical adjustment louver "45˚", Horizontal adjustment louver "front"
3) Indoor air temp. : Colling 27˚C

(Running frequency: 68HZ) (Running frequency: 88Hz)

1200 1200
Input(W)

Input(W)
1000 1000

800 800

600 600

Outlet air temp.(˚C)

Outlet air temp.(˚C)


14 14

12 12

10 10
Cooling capacity(kW)

Cooling capacity(kW)
2.6 2.8

2.4 2.6

2.2 2.4

2.0 2.2

25 30 35 40 25 30 35 40
Outside air temp.(˚C) Outside air temp.(˚C)

Figure P-3. At Cooling for AY-X075E Figure P-4. At Cooling for AY-X095E

(Running frequency: 89Hz) (Running frequency: 96Hz)

1400 1400
Input(W)
Input(W)

1200 1200

1000 1000

Outlet air temp.(˚C)


Outlet air temp.(˚C)

800 45 800 45

40 40

35 35
Heating capacity(kW)
Heating capacity(kW)

3.6 3.8

3.2. 3.4

2.8 3.0

2.4 2.6

-5 0 5 10 -5 0 5 10
Outside air temp.(˚C) Outside air temp.(˚C)

Figure P-5. At Heating for AY-X075E Figure P-6. At Heating for AY-X095E

37
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

DISASSEMBLING PROCEDURE
FOR INDOOR UNIT MODEL AH-X075E/X095E AND AY-X075E/X095E

CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING

1. Using the narrow slotted screwdriver or similar, remove 3. Open the open panel, and remove the right air filter.
the screw cover from the front panel.

How to remove the screw cover 4. Remove one inner screw.


a. Press the top of the screw cover with the flat-tipped Note: During reassembly, don’t tighten the screw
screwdriver (or nail, etc). strongly, or it will become idle.
b. Insert the flat-tipped screwdriver (or nail, etc) into the
lower clearance, and pull and lift it toward you for
removal.

b
Screw cover

5. Remove the fastening screw which retains the cable,


and remove the cord.
Note: During reassembly, install the holder after
2. Remove two screws from the front panel. installing the front panel. This will make it easier
to assemble the front panel.

38
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
6. After closing the open panel, open the vertical adjustment 9. Remove the control box cover.
louver and pull out the bottom of the front panel toward Holding its bottom, pull and disengage the upper hook
you. toward the bottom.
Lifting the front panel, strongly pull the top toward you.
Making the front panel parallel to the main body, strongly
pull it toward you for removal.
To install the front panel, place the bottom of the front
panel under the open vertical adjustment louver, and
press in the front panel, parallel to the cabinet. When
pressing it in, take care to prevent the top of the blow-out
port of the drain pan from being caught by the front panel.

10.Remove the ground wire. (One screw)


Note: During reassembly, take care for the direction
of the lead wire.

7. Remove the unit-to-unit wiring from the terminal board.


(Loosen the screw with the screwdriver, and pull out the
wiring.)

11.Remove the protect cover for the dew.


Note: During reassembly, verify that the dew on the
pipe is recovered to the drain pan.

8. Remove one fastening screw from the control box cover.

39
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
12. Remove the thermostat of the evaporator. 15.Remove six fastening screws of the control box, and
(Pull it out after peeling off the thermoseal.) remove the control box.

13.Cut the tie band of the lead wire. 16.Remove the fastening screws of the drain pan. (Two
screws on the left side).

14.Remove two connectors of the fan motor and one of 17.Turn the cap area of the drain hose counterclockwise,
louver motor. and remove it from the drain pan.

Drain hose

Drain pan
Projection
Groove

During installation, turn the drain hose to the state of the


“engagement position”.
After reinstallation, verify that it is securely fastened.

To disconned To reconnect

40
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

18.Pull down the drain pan toward you for removal.

19.Remove two fastening screws of the evaporator. 21.Loosen the fan fastening screw, and remove the fan.

20.Move the evaporator to the right, and release it from two <Cautionary points for assembling the fan>
hooks. Free the evaporator, and pull down the cross-flow a. When inserting the shaft of the cross-flow fan into the
fan and motor toward you. Remove them together. (If it metal, take care to prevent injuring the inner surface
is tried to remove the fan alone, it will damage the inner of the metal.
surface of the metal to prevent removing the fan.) b. Before fastening the motor shaft and fan, insert the
shaft into contact with the fan boss.

Fan boss

Motor shaft

Fan

41
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

22. To remove the evaporator, remove the tube holder on the 3. Remove the cord holder fastening screw of the power
rear side of the cabinet, slightly lift the left side, slide it to supply cord.
the right, and remove it from the cabinet, pulling it toward
you.

4. Remove the terminal board fastening screw of the power


supply cord.
How to remove the electric control box.
1. Remove the indicator assembly.
(Press and spread the upper hook, and the indicator will
be ready for removal.)

5. Remove the thermostat holder from the control box.

2. Remove the fastening screw of the terminal board.

42
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

6. Remove the board fastening screws. Drain pan and related


How to remove the gear box assembly
Remove two screws which fasten the gear box assembly.
Note When installing the gear box assembly, fit it,
aligning the notch shape of the groove of the
vertical adjusment louver.

the angle of transformer

7. Pull out the board.

How to remove the vertical adjustment louver


Slightly fall down the hinge area, deflect the louver, and
remove it at one place. Remove the shaft from each of the
left and right sides.

43
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

SERVICING PROCEDURE
FOR OUTDOOR UNIT MODEL AU-X075E/X095E AND AE-X075E/X095E

CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING

1. Remove the lid of the control box. (2 screws)


3. Remove the front panel assembly.
Disconnect the unit-to-unit wiring from the terminal board.
Pulling the bottom toward you, disengage 2 hooks on the
rear surface.

LX-BZA176JBE0

4. Remove 11 screws which fasten the rear panel assembly.


2. Free the front panel assembly.
(Even though the rear panel assembly is not removed,
Remove 2 screws from each of the right and left sides
most of the services are possible.)
and one screw from the front side.

5. Cut the tie band. (2 places)

44
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

6. Disconnect the connector. (4 places) 9. Remove 2 screws which fasten the motor angle.
Disconnect the Faston terminal. (10 places) Pull up the motor angle for removal.
(During reassembling, treat the lead wire to prevent it
from being in contact with the propeller fan.)

10. Remove 3 motor fastening screws, and remove the


motor.

Remove the 2 screws of the control PWB, and the control


circuit will be ready for removal from the control box.

7. Remove 2 fastening screws of the control box. 11. Remove the bulk head.
Remove 2 small screws which fasten the ground cable. Remove 2 fastening screws. Lifting the bulk head, remove
Remove the electric battery box. 2 inner hooks.

Ground cable LX-BZA175JBE0

8. Remove the outdoor fan. 12. Remove 2 screws which fasten the choke coil, and
remove the choke coil.

45
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

13. Remove the compressor cover. (Remove four staples.) 16. Remove the front panel assembly.
Orifice 2 screws 4 hooks
Control cover 4 screws
Wire guard 4 screws
Remove these screws and disengage these hooks.

4 screws

2 screws

14. Remove the thermostat of the heat exchanger.


Heat exchange pipe thermistor
4 hook
30‘ 50mm

17. Cautions when replacing the Power Factor Module,


Power Transistor Module, or Diode Bridge
(1) The screws should be firmly tightened at the
torque of 8 to 10 kg f cm (78.4 to 98 N).
Joint tube
(2) For the Power Transistor Module or Diode Bridge,
Heat exchange pipe thermistor be sure to insert the silicon sheet between it and
fixed position radiator plate.
(3) For the Power Factor Module, the silicon grease
15. (AE-X075E/X095E only) should be evenly applied between it and radiator
Remove the coil of the four-way valve. plate.
After removing the fastening spring of the four-way
valve, pull up the coil for removal.
Note: During reassembling, engage the projection
of the main body of the four-way valve into the
groove of the coil. Take care for the polarity of
the coil wiring.

Groove

Projection

46
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

47
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

48
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

49
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

50
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

REPLACEMENT PARTS LIST (AH-X075E/AH-X095E)

REF. NO. PART NO. DESCRIPTION Q'TY CODE


CABINET AND UNIT PARTS
1- 1 CMOT-A263JBE0 Fan motor sub assembly 1 BH
1- 2 PGUMMA071JBE0 Motor cushion 1 AN
1- 3 CHLD-A050JBK0 Bearing assembly 1 AG
1- 4 DCHS-A233JBK0 Cabinet assembly 1 AX
1- 5 NFANCA058JBE0 Cross flow fan 1 AS
1- 6 CSRA-A375JBK0 Drain pan assembly 1 BE
1- 7 DSRA-A186JBK0 Drain pan sub assembly 1 AV
1- 8 MJNTPA058JBFA Louver link 2 AC
1- 9 MLOV-A184JBFA Horizontal adjustment louver 10 AB
1- 10 MLOV-A172JBFA Vertical adjustment louver 1 AH
1- 11 MLOV-A173JBFA Vertical adjustment louver 1 AK
1- 12 GGAD-A029JBTA Fan guard 1 AX
1- 13 LHLD-A197JBFA Louver holder 2 AX
1- 14 NBRG-A010JBFA Louver bushing 2 AA
1- 15 PBOX-A186JBK0 Louver gear assembly 1 BA
1- 16 CHOS-A004JBK0 Drain hose assembly 1 AM
1- 17 PPACGA010JBE0 O ring 1 AB
1- 18 DCOV-A138JBFA Drain pan cover 1 AM
1- 19 RMOT-A061JBE0 Louver motor 1 AS
1- 20 PGUMMA110JBE0 Drain cap 1 AD
1- 21 CWAK-B443JBK0 Front panel assembly 1 AU
1- 22 CPNL-A114JBK0 Open panel assembly 1 AM
1- 23 HBDG-A059JBEA Badge 1 AF
1- 24 DDEC-A033JBK0 Display cover assembly 1 AH
1- 25 PFILMA088JBEA Air filter 1 AK
1- 25 PFILMA090JBEA Air filter 1 AK
1- 26 LHLD-A302JBFA Tube holder 1 AD
1- 27 LHLD-A303JBFA Tube holder 1 AD
1- 28 TSPC-B795JBR0 Name badge [AH-X075E] 1 AH
1- 28 TSPC-B792JBR0 Name badge [AH-X095E] 1 AH
1- 29 TLABKB679JBR0 Number card [AH-X075E] 1 AB
1- 29 TLABKB677JBR0 Number card [AH-X095E] 1 AB
1- 30 PGUMMA082JBE0 Motor cushion 1 AD
1- 31 GWAK-A203JBFA Front panel 1 AQ
1- 32 PCOV-A306JBF0 Protect cover 1 AE
CONTROL BOX
2- 1 LHLD-A281JBFA Cord holder 1 AC
2- 2 PBOX-A182JBF0 Control box 1 AN
2- 3 LHLD-A313JBF0 Cord holder 1 AC
2- 4 LHLD-A282JBF0 Thermistor holder 1 AG
2- 5 PCOV-A300JBF0 Thermistor holder cover 1 AB
2- 6 HPNLCA578JBFA Control box cover 1 AF
2- 7 HPNLCA595JBEA Control panel 1 AC
2- 8 PCOV-A278JBF0 LED holder 1 AH
2- 9 TLABCA726JBR0 Wiring diagram 1 AC
2- 10 DSGY-A642JBK0 Electric control board [AH-X075E] 1 BM
2- 10 DSGY-A641JBK0 Electric control board [AH-X095E] 1 BE
2- 11 QACC-A176JBE0 Source code 1 AY
2- 12 QTAN-A152JBE0 Terminal board 1 AN
2- 13 QTAN-A186JBE0 4 poles terminal board 1 AP
2- 14 QW-VZC486JBE0 Terminal wire L 1 AF
2- 15 QW-VZC487JBE0 Terminal wire N 1 AE
2- 16 QW-VZC488JBE0 Main relay wire 1 AE
2- 17 QW-VZC489JBE0 Earth lead 1 AF
2- 18 QW-VZC500JBE0 Louver motor wire 1 AF
2- 19 QW-VZC406JBE0 Fan motor wire 1 AK
CYCLE PARTS
3- 1 CPIPCA353JBK0 Pipe assembly 1 AX
3- 2 PSEN-A004JBK0 Flare nut assembly 1 AE
3- 3 PSEN-A005JBK0 Flare nut assembly 1 AG
3- 4 PVLV-A082JBE0 Flare union 1 AF
3- 5 PVLV-A083JBE0 Flare union 1 AG
3- 6 DEVA-A020JBK0 Evaporator assembly 1 BP

51
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

REF. NO. PART NO. DESCRIPTION Q'TY CODE


ACCESSORY PARTS
4- 1 CRMC-A358JBE0 Remote controller 1 BC
4- 2 FCOV-A013JBFA Screw cover 2 AB
4- 3 LX-NZ0247JBE0 Special nut 1 AB
4- 4 XTNUZ40P20000 Tapping screw 1 AB
4- 5 GLEGGA008JBE0 Anti-vibration rubber 4 AE
4- 6 LPFT-A029JBF0 Drain hose adpter 1 AD
4- 7 PPLTNA030JBP0 Mounting plate 1 AL
4- 8 XTTSD45P30000 Long screw 6 AA
4- 9 TINSEA087JBR0 Operation manual 1 AM
4- 10 TINS-A327JBR0 Installation manual 1 AD
SCREWS
5- 1 LX-BZA075JBE0 Special screw 1 AA

HOW TO ORDER REPLACEMENT PARTS

To have your order filled prompty and correctly, please furnish the following information.

1. MODEL NUMBER 2. REF. NO.


3. PART NO. 4. DESCRIPTION

52
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

1 2 3 4 5 6

INDOOR UNIT

A 1-4 A

3-6

4-7

B B

1-26
3-2 4-10
3-3
1-32
2-2
C 4-9 C
2-4
5-1
2-5
1-6

2-11
2-6 1-20
2-13
D 2-7 D

2-12 1-9
1-8
2-8 1-17
2-10
1-18 1-16

E
1-14 E
1-5

1-3 1-15
1-10
1-19

2-19
F F

1-30
1-2
1-11
1-1
1-26 4-1

G G

1-31

H 1-23 H

1-22
1-24

1 2 3 4 5 6

53
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

REPLACEMENT PARTS LIST (AU-X075E/AU-X095E)

REF. NO. PART NO. DESCRIPTION Q'TY CODE


CONTROL BOX PARTS AND ELECTRIC PARTS
1- 1 CMOTLA485JBE0 Fan motor 1 BF
1- 4 DSGY-A643JBK0 Electric control board [AU-X075E] 1 BP
1- 4 DSGY-A639JBK0 Electric control board [AU-X095E] 1 BH
1- 5 QTAN-A186JBE0 Terminal board (4P) 1 AP
1- 7 QW-VZC471JBE0 Compressor wire 1 AN
1- 8 QW-VZC472JBE0 Wire assembly 1 AS
1- 9 QW-VZC473JBE0 Active filter wire 1 AF
1- 10 RC-AZA046JBE0 Capacitor 1 BE
1- 11 RH-DZA117JBE0 Diode bridge 1 AM
1- 12 RH-HZ0011JBE0 Ptc thermistor 1 AN
1- 13 RH-TZA145JBE0 Power transistor module (IPM) 1 BU
1- 14 RH-TZA106JBE0 Power factor module 1 BL
1- 15 QW-VZC474JBE0 Choke coil wire 1 AH
1- 16 RTHM-A022JBE0 Compressor thermistor 1 AN
1- 17 RTHM-A236JBE0 Thermistor assembly 1 AP
1- 18 RTRN-A199JBE0 Choke coil 1 BE
1- 19 PBOX-A180JBF0 Control box 1 AR
1- 20 LBND-A014JBE0 Wire fixing band 4 AA
1- 21 MSPR-A102JBE0 Spring 1 AE
1- 22 PCOV-A304JBF0 Sheet 1 AD
1- 23 PRDAFA072JBE0 Heat sink for IPM 1 AQ
1- 24 PRDAFA073JBE0 Heat sink for DB 1 AH
1- 25 PSHEGA011JBE0 Rubber for DB 1 AB
1- 27 RFIL-A060JBE0 Ferrite core 3 AF
1- 28 RFIL-A064JBE0 Ferrite core 1 AF
CABINET AND UNIT PARTS
2- 1 LANGKA050JBP0 Fan motor angle 1 AM
2- 2 PFPFPB087JBE0 Motor angle cushion 1 AC
2- 3 GCAB-A119JBFA Rear cabinet 1 AW
2- 4 LHLD-0261JBM0 Cord holder 1 AB
2- 6 GCAB-A118JBFA Front cabinet 1 BG
2- 7 GGAD-A028JBTA Fan guard AY
2- 8 PCOV-A279JBP0 Control box cover 1 AL
2- 9 PGID-A042JBFA Orifice 1 AP
2- 10 PSEL-A841JBE0 Gasket 1 AE
2- 11 PSEL-A877JBE0 Gasket 1 AC
2- 12 TLABBA111JBRA Sharp badge 1 AH
2- 13 CCHS-A501JBTA Base pan assembly 1 AG
2- 14 PFTA-A034JBFA Control box cover 1 AM
2- 15 PSHE-A134JBE0 Protect sheet 1 AD
2- 16 MSPR-A027JBE0 Spring 1 AB
2- 17 MSPR-A046JBE0 Spring 1 AC
2- 18 NFANPA041JBE0 Propeller fan 1 AU
2- 19 FSKR-A005JBK0 Bulkhead 1 AQ
2- 20 TLABKB683JBR0 Number card [AU-X075E] 1 AB
2- 20 TLABKB682JBR0 Number card [AU-X095E] 1 AB
2- 21 TSPC-B794JBR0 Name badge [AU-X075E] 1 AH
2- 21 TSPC-B793JBR0 Name badge [AU-X095E] 1 AH
2- 22 PSEL-A879JBE0 Gasket 1 AD
2- 23 PFPFPB149JBE0 Insulator 1 AC
2- 24 TLABCA752JBR0 Wiring diagram 1 AD
2- 26 PSEL-A880JBE0 Insulator 1 AC
CYCLE PARTS
3- 2 CVLV-A316JBK0 Capillary tube assembly [AU-X075E] 1 AP
3- 2 CVLV-A329JBK0 Capillary tube assembly [AU-X095E] 1 AQ
3- 3 DCON-A007JBP0 Condensor assembly 1 BN
3- 4 DVLV-A252JBK0 3 way valve unit 1 AX
3- 5 LX-NZA034JBE0 Service nut 1 AD
3- 6 LX-NZA081JBE0 Bonnet 2 AG
3- 7 DVLV-A253JBK0 2 way valve unit 1 AW
3- 9 FCMPRA035JBK0 Compressor assembly (2-17, 3-20 and 3-21 included) 1 CF
3- 10 GLEG-A057JBE0 Compressor cushion 3 AD
3- 11 PSPF-A451JBE0 Compressor cover 1 AX
3- 12 PSPF-A462JBE0 Sound proof cover 1 AG
3- 13 PSEN-A004JBK0 Flare nut assembly 1 AE
3- 14 PSEN-A005JBK0 Flare nut assembly 1 AG
3- 15 PGUMSA069JBE0 Damper rubber 1 AE

54
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

REF. NO. PART NO. DESCRIPTION Q'TY CODE


3- 16 PGUMSA222JBE0 Damper rubber 1 AL
3- 17 PSEL-A878JBE0 Cushion 1 AD
3- 18 CPIPCA373JBK0 Suction pipe assembly 1 AZ
3- 19 CPIPCA374JBK0 Discharge pipe assembly 1 AW
3- 20 PGUMSA033JBE0 Damper rubber B 1 AK
3- 21 PGUMS0170JBE0 Damper rubber 1 AF
3- 22 PGUM-0034JBE0 Damper rubber U3 1 AG
SCREWS AND NUTS
4- 1 LX-BZA091JBE0 Special screw [AU-X075E] 9 AA
4- 1 LX-BZA091JBE0 Special screw [AU-X095E] 9 AA
4- 2 LX-BZA072JBE0 Special screw 4 AB
4- 3 LX-BZA107JBE0 Special screw 1 AC
4- 4 LX-BZA166JBE0 Special screw 6 AB
4- 5 LX-NZA026JBE0 Special screw 3 AC
4- 6 LX-BZA075JBE0 Special screw 2 AA
4- 7 LX-BZA091JBE0 Special screw 7 AA
4- 8 LX-BZA131JBE0 Special screw 11 AB
4- 9 LX-BZA166JBE0 Special screw [AU-X075E] 7 AB
4- 9 LX-BZA166JBE0 Special screw [AU-X095E] 7 AB
4- 10 LX-NZA110JBE0 Special nut 1 AB
4- 11 XTSSF40P12000 Special nut 7 AB
4- 12 LX-BZA175JBE0 Special screw 1 AC
4- 13 LX-BZA176JBE0 Special screw 1 AC

HOW TO ORDER REPLACEMENT PARTS

To have your order filled prompty and correctly, please furnish the following information.

1. MODEL NUMBER 2. REF. NO.


3. PART NO. 4. DESCRIPTION

55
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

1 2 3 4 5 6

OUTDOOR UNIT
A A
1-27

1-9
1-14

1-13
1-11
1-23
1-25
1-26
1-24 1-21
B B
1-28
2-3
1-7

1-22

1-4

C
2-4 2-14 C
1-10

1-5

2-26
1-12 1-19
4-13
2-1
2-2 3-3
2-15
D D

4-4
2-18
3-2 2-21

1-16
3-20
2-17 2-16

4-10 3-19 1-17


E 1-1 E
3-17
3-21
2-23 3-18
1-15
3-13
3-9 3-6
2-19
4-5 3-14
3-15 3-4
2-9 3-10 3-16 3-6
3-5
2-6
3-12
1-18
4-12
F F
2-12
2-13

4-2
2-22

G 4-3 G
2-11

2-8 3-11

2-7

H 2-24 H

2-10

1 2 3 4 5 6

56
AH-X075E/X095E
AU-X075E/X095E
REPLACEMENT PARTS LIST (AY-X075E/AY-X095E) AY-X075E/X095E
AE-X075E/X095E

REF. NO. PART NO. DESCRIPTION Q'TY CODE


CABINET AND UNIT PARTS
1- 1 CMOT-A263JBE0 Fan motor sub assembly 1 BH
1- 2 PGUMMA071JBE0 Motor cushion 1 AN
1- 3 CHLD-A050JBK0 Bearing assembly 1 AG
1- 4 DCHS-A233JBK0 Cabinet assembly 1 AX
1- 5 NFANCA058JBE0 Cross flow fan 1 AS
1- 6 CSRA-A375JBK0 Drain pan assembly 1 BE
1- 7 DSRA-A186JBK0 Drain pan sub assembly 1 AV
1- 8 MJNTPA058JBFA Louver link 2 AC
1- 9 MLOV-A184JBFA Horizontal adjustment louver 10 AB
1- 10 MLOV-A172JBFA Vertical adjustment louver 1 AH
1- 11 MLOV-A173JBFA Vertical adjustment louver 1 AK
1- 12 GGAD-A029JBTA Fan guard 1 AX
1- 13 LHLD-A197JBFA Louver holder 2 AX
1- 14 NBRG-A010JBFA Louver bushing 2 AA
1- 15 PBOX-A186JBK0 Louver gear assembly 1 BA
1- 16 CHOS-A004JBK0 Drain hose assembly 1 AM
1- 17 PPACGA010JBE0 O ring 1 AB
1- 18 DCOV-A138JBFA Drain pan cover 1 AM
1- 19 RMOT-A061JBE0 Louver motor 1 AS
1- 20 PGUMMA110JBE0 Drain cap 1 AD
1- 21 CWAK-B443JBK0 Front panel assembly 1 AU
1- 22 CPNL-A114JBK0 Open panel assembly 1 AM
1- 23 HBDG-A059JBEA Badge 1 AF
1- 24 DDEC-A033JBK0 Display cover assembly 1 AH
1- 25 PFILMA088JBEA Air filter 1 AK
1- 25 PFILMA090JBEA Air filter 1 AK
1- 26 LHLD-A302JBFA Tube holder 1 AD
1- 27 LHLD-A303JBFA Tube holder 1 AD
1- 28 TSPC-B790JBR0 Name badge [AY-X075E] 1 AH
1- 28 TSPC-B733JBR0 Name badge [AY-X095E] 1 AH
1- 29 TLABKB680JBK0 Number card [AY-X075E] 1 AC
1- 29 TLABKB681JBK0 Number card [AY-X095E] 1 AC
1- 30 PGUMMA082JBE0 Motor cushion 1 AD
CONTROL BOX
2- 1 LHLD-A281JBFA Cord holder 1 AC
2- 2 PBOX-A182JBF0 Control box 1 AN
2- 3 LHLD-A313JBF0 Cord holder 1 AC
2- 4 LHLD-A282JBF0 Thermistor holder 1 AG
2- 5 PCOV-A300JBF0 Thermistor holder cover 1 AB
2- 6 HPNLCA578JBFA Control box cover 1 AF
2- 7 HPNLCA595JBEA Control panel 1 AC
2- 8 PCOV-A278JBF0 LED holder 1 AH
2- 9 TLABCA726JBR0 Wiring diagram 1 AC
2- 10 DSGY-A640JBK0 Electric control board [AY-X075E] 1 BM
2- 10 DSGY-A636JBK0 Electric control board [AY-X095E] 1 BM
2- 11 QACC-A176JBE0 Source code 1 AY
2- 12 QTAN-A152JBE0 Terminal board 1 AN
2- 13 QTAN-A186JBE0 4 poles terminal board 1 AP
2- 14 QW-VZC486JBE0 Terminal wire L 1 AF
2- 15 QW-VZC487JBE0 Terminal wire N 1 AE
2- 16 QW-VZC488JBE0 Main relay wire 1 AE
2- 17 QW-VZC489JBE0 Earth lead 1 AF
2- 18 QW-VZC500JBE0 Louver motor wire 1 AF
2- 19 QW-VZC406JBE0 Fan motor wire 1 AK
CYCLE PARTS
3- 1 CPIPCA353JBK0 Pipe assembly 1 AX
3- 2 PSEN-A004JBK0 Flare nut assembly 1 AE
3- 3 PSEN-A005JBK0 Flare nut assembly 1 AG
3- 4 PVLV-A082JBE0 Flare union 1 AF
3- 5 PVLV-A083JBE0 Flare union 1 AG
3- 6 DEVA-A020JBK0 Evaporator assembly 1 BP

57
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

REF. NO. PART NO. DESCRIPTION Q'TY CODE


ACCESSORY PARTS
4- 1 CRMC-A357JBE0 Remote controller 1 BC
4- 2 FCOV-A013JBFA Screw cover 2 AB
4- 3 LX-NZ0247JBE0 Special nut 1 AB
4- 4 XTNUZ40P20000 Tapping screw 1 AB
4- 5 GLEGGA008JBE0 Anti-vibration rubber 4 AE
4- 6 LPFT-A029JBF0 Drain hose adpter 1 AD
4- 7 PPLTNA030JBP0 Mounting plate 1 AL
4- 8 XTTSD45P30000 Long screw 6 AA
4- 9 TINSEA082JBR0 Operation manual 1 AM
4- 10 TINS-A327JBR0 Installation manual 1 AD
SCREWS
5- 1 LX-BZA075JBE0 Special screw 1 AA

HOW TO ORDER REPLACEMENT PARTS

To have your order filled prompty and correctly, please furnish the following information.

1. MODEL NUMBER 2. REF. NO.


3. PART NO. 4. DESCRIPTION

58
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

1 2 3 4 5 6

INDOOR UNIT

A 1-4 A

3-6

4-7

B B

1-26
3-2 4-10
3-3
1-32
2-2
4-9
C 2-4 C
5-1
2-5
1-6

2-11
2-6 1-20
2-13
2-7
D D
2-12 1-9
1-8
2-8 1-17
2-10
1-18 1-16

1-14
E 1-5 E

1-3 1-15
1-10
1-19

2-19
F F
1-30
1-2
1-11
1-1
1-26 4-1

G G
1-31

1-23
H H

1-22
1-24

1 2 3 4 5 6

59
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

REPLACEMENT PARTS LIST (AE-X075E/AE-X095E)

REF. NO. PART NO. DESCRIPTION Q'TY CODE


CONTROL BOX PARTS
1- 1 CMOTLA485JBE0 Fan motor 1 BF
1- 2 QW-VZC475JBE0 4 way valve coil wire 1 AF
1- 3 RCIL-A050JBE0 4 way valve coil 1 AX
1- 4 DSGY-A638JBK0 Electric control board [AE-X075E] 1 BP
1- 4 DSGY-A632JBK0 Electric control board [AE-X095E] 1 BK
1- 5 QTAN-A186JBE0 Terminal board (4P) 1 AP
1- 7 QW-VZC471JBE0 Compressor wire 1 AN
1- 8 QW-VZC472JBE0 Wire assembly 1 AS
1- 9 QW-VZC473JBE0 Power factor module wire 1 AF
1- 10 RC-AZA046JBE0 Capacitor 1 BE
1- 11 RH-DZA117JBE0 Diode bridge 1 AM
1- 12 RH-HZ0011JBE0 Ptc thermistor 1 AN
1- 13 RH-TZA145JBE0 Power transistor module(IPM) 1 BU
1- 14 RH-TZA106JBE0 Power factor module(Active filter) 1 BL
1- 15 QW-VZC474JBE0 Choke coil wire 1 AH
1- 16 RTHM-A022JBE0 Compressor thermistor 1 AN
1- 17 RTHM-A230JBE0 Thermistor assembly 1 AQ
1- 18 RTRN-A199JBE0 Choke coil 1 BE
1- 19 PBOX-A180JBF0 Control box 1 AR
1- 20 LBND-A014JBE0 Wire fixing band 4 AA
1- 21 MSPR-A102JBE0 Spring 1 AE
1- 22 PCOV-A304JBF0 Sheet 1 AD
1- 23 PRDAFA072JBE0 Heat sink for Power transistor module 1 AQ
1- 24 PRDAFA073JBE0 Heat sink for DB 1 AH
1- 25 PSHEGA011JBE0 Rubber for DB 1 AB
1- 27 RFIL-A060JBE0 Ferrite core 3 AF
1- 28 RFIL-A064JBE0 Ferrite core 1 AF
CABINET AND UNIT PARTS
2- 1 LANGKA050JBP0 Fan motor angle 1 AM
2- 2 PFPFPB087JBE0 Motor angle cushion 1 AC
2- 3 GCAB-A119JBFA Rear cabinet 1 AW
2- 4 LHLD-0261JBM0 Cord holder 1 AB
2- 6 GCAB-A118JBFA Front cabinet 1 BG
2- 7 GGAD-A028JBTA Fan guard AY
2- 8 PCOV-A279JBP0 Control box cover 1 AL
2- 9 PGID-A042JBFA Orifice 1 AP
2- 10 PSEL-A841JBE0 Gasket 1 AE
2- 11 PSEL-A877JBE0 Gasket 1 AC
2- 12 TLABBA111JBRA Sharp badge 1 AH
2- 13 CCHS-A501JBTA Base pan assembly 1 AG
2- 14 PFTA-A034JBFA Control box cover 1 AM
2- 15 PSHE-A134JBE0 Protect sheet 1 AD
2- 16 MSPR-A027JBE0 Spring 1 AB
2- 17 MSPR-A046JBE0 Spring 1 AC
2- 18 NFANPA041JBE0 Propeller fan 1 AU
2- 19 FSKR-A005JBK0 Bulkhead 1 AQ
2- 20 TLABKB685JBK0 Number card [AE-X075E] 1 AB
2- 20 TLABKB684JBK0 Number card [AE-X095E] 1 AB
2- 21 TSPC-B791JBR0 Name badge [AE-X075E] 1 AH
2- 21 TSPC-B736JBR0 Name badge [AE-X095E] 1 AH
2- 22 PSEL-A879JBE0 Gasket 1 AD
2- 23 PFPFPB149JBE0 Insulator 1 AC
2- 24 TLABCA751JBR0 Wiring diagram 1 AD
2- 26 PSEL-A880JBE0 Insulator 1 AC
CYCLE PARTS
3- 1 DVLV-A264JBK0 Reverse valve sub assembly(Assembly of 3-23 to 3-32) 1 BE
3- 2 CVLV-A316JBK0 Capillary tube assembly [AE-X075E] 1 AP
3- 2 CVLV-A329JBK0 Capillary tube assembly [AE-X095E] 1 AQ
3- 3 DCON-A007JBP0 Condensor assembly 1 CD
3- 4 DVLV-A252JBK0 3 way valve unit 1 AX
3- 5 LX-NZA034JBE0 Service nut 1 AD
3- 6 LX-NZA081JBE0 Bonnet 2 AG
3- 7 DVLV-A253JBK0 2 way valve unit 1 AW
3- 9 FCMPRA035JBK0 Compressor assembly (2-17, 3-20 and 3-21 included) 1 CF
3- 10 GLEG-A057JBE0 Compressor cushion 3 AD
3- 11 PSPF-A451JBE0 Compressor cover 1 AX
3- 12 PSPF-A462JBE0 Sound proof cover 1 AG

60
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

REF. NO. PART NO. DESCRIPTION Q'TY CODE


3- 13 PSEN-A004JBK0 Flare nut assembly 1 AE
3- 14 PSEN-A005JBK0 Flare nut assembly 1 AG
3- 15 PGUMSA069JBE0 Damper rubber 1 AE
3- 16 PGUMSA222JBE0 Damper rubber 1 AL
3- 17 PSEL-A878JBE0 Cushion 1 AD
3- 20 LBSHCA005JBE0 Terminal bushing 1 AA
3- 21 MSPRPA011JBE0 Spring 1 AF
3- 22 PGUMS0170JBE0 Damper rubber 1 AF
3- 23 PSEL-A876JBE0 Insulator 1 AC
SCREWS AND NUTS
4- 1 LX-BZA091JBE0 Special screw [AE-X075E] 9 AA
4- 1 LX-BZA091JBE0 Special screw [AE-X095E] 9 AA
4- 2 LX-BZA072JBE0 Special screw 4 AB
4- 3 LX-BZA107JBE0 Special screw 1 AC
4- 4 LX-BZA166JBE0 Special screw 5 AB
4- 5 LX-NZA026JBE0 Special screw 3 AC
4- 6 LX-BZA075JBE0 Special screw 2 AA
4- 7 LX-BZA091JBE0 Special screw 7 AA
4- 8 LX-BZA131JBE0 Special screw 11 AB
4- 9 LX-BZA166JBE0 Special screw [AE-X075E] 7 AB
4- 9 LX-BZA166JBE0 Special screw [AE-X095E] 7 AB
4- 10 LX-NZA110JBE0 Special nut 1 AB
4- 11 XTSSF40P12000 Special nut 7 AB
4- 12 LX-BZA175JBE0 Special screw 2 AC
4- 13 LX-BZA176JBE0 Special screw 1 AC

HOW TO ORDER REPLACEMENT PARTS

To have your order filled prompty and correctly, please furnish the following information.

1. MODEL NUMBER 2. REF. NO.


3. PART NO. 4. DESCRIPTION

61
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

1 2 3 4 5 6

OUTDOOR UNIT
A 1-27 A

1-9
1-14

1-13
1-11
1-23
1-26 1-25
1-24 1-21
B B
1-28
2-3
1-7

1-22
1-4

2-4 2-14
C 1-10 C

1-5
4-13

2-26
1-12 1-19
2-1
2-2 3-3
2-15
D D
4-4

2-18
3-2 2-21
3-20 3-21 1-3
3-1
1-16

2-17 2-16

4-10 3-17 1-17


1-1
E E

2-23
1-15 3-13
2-19 3-9 3-6
4-5 3-15 3-14
3-4
2-9 3-7 3-6
3-10 3-16 3-5
2-6
3-12
1-18
4-12
F 2-12 F
2-13

4-2
2-22

2-11 4-3
G G

2-8 3-11

2-7

2-24
H H

2-10

1 2 3 4 5 6

'95 SHAP CORP. (4U0.50E) Printed in Japan


62
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

63
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

64
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E

'95 SHAP CORP. (4U0.50E) Printed in Japan


65

You might also like