You are on page 1of 46

LSM20 SINGLE PHASE

ELECTRICITY SMART METER


Item MoE specification Company specification Page No.
General specification:
Single and three phase energy smart meters, designed for LSM Series Active-Reactive Electric Electricity Meters can
measuring and registration of active, reactive and measure and record active import energy. Voltage and
apparent energy for direct connection network, and to be current measurement, and energy calculation is carried out
remotely controlled from a main data collection center. by the microprocessor in the meter. If energy is in reverse
The customer can get the consumption information direction, the import meter takes its absolute value and
timely by (HAN) and IHD (in-Home Display option) in assumes it as positive. The import-export meter, however,
1 order to make a policy decision for efficient use of energy. measures and stores the data of import and export energy Page 4
And the energy suppliers can get the information timely separately. Additionally, reactive energy, apparent energy
or regularly by WAN and MDMS as well, so that they can can also be measured and recorded. Program memory is
manage the energy supply properly and provide better fully protected for fraud attempts and tamper with the
service. Energy smart meter is provided with the metering program code.
ability, and the most important advantage is two-way
communication ability.

Environmental specifications:
Ambient temperature: Operating Temperature Range: -40⁰C + 85⁰C
Highest max. (in the shade): (+55 deg.C.(About 6 hours a
2 day)) Page 35
Lowest min. (-10 deg.C)
Max Yearly average: (+30 deg.C)
Sun Temperature Operating Temperature Range: -40⁰C + 85⁰C
3 Black object under direct sunshine may attain a Page 35
temperature of (+85 deg.C)
Air Humidity Relative Air Humidity: 95%
Max: (92% at 40 deg.C)
4 Page 35
Min: (12%)
Yearly average: (44%)
Altitude Till 2000 m from sea level
5 Page 35
from sea level up to (1000m)

Technical Requirement:
Features: The smart energy meters have many features including those related to (AMl) functions as follows:
MEASUREMENT LSM series capable of measuring;
Page 4
- Metering import\export, active\reactive, energy in four - Active energy in all 4 quadrants as import energy or
&
quadrants and demand. import/export energy.
6 Page 5
- Measuring instantaneous voltage current active power, - Reactive energy in all 4 quadrants as reactive import
&
reactive power, apparent power, power factor, Vrms, Irms energy or reactive import/export energy
Page 7
frequency,

Page 1 of 6
- Support maximum 8 tariffs. TOU of total import\export, - Total import and export active power, total import and
active energy, reactive energy. export reactive power. Calculation period is programmable.
- Metering data will be refreshed every second. - Instantaneous voltage, current, active power, reactive
- Metering data is stored in EEPROM, store the maximum power, apparent power, power factor, frequency for each
active demand with time and data stamps. phase or total three phase.
- Cumulative demand indication. - Advanced Tariff (Optional): LSM meters optionally have
advanced tariffs structure. 8 different tariff
profiles can be defined for each day in a week and specified
holidays.
- Eeprom or Flash Ic is used for data backup and log records.
- Reactive energy of Q1+Q2 and Q3+Q4 quadrants. (3.8.0
and 4.8.0)
Communication interface Optical Port:
- Optical communication port comply with IEC 62056-21 - Optical port feature enables data transfer and
Module-E protocol and supports local data exchange and programming in compliance with EN 61107 communication
reading. protocol.
- RS485 port – RS232 port, UART interfaces. - RS485 Communication Port: In case there is only one
- Ethernet port meter connected to the data line, the meter can be readout
- Optical fiber port small form-factor pluggable (SFP) for using the format “/?!CRLF” via RS485 protocol.
connecting meter to DCU via fiber optic cable. - Pluggable Ethernet Module: It is designed as an external
- For a detachable modem, the meter provides with the Ethernet module. It can be easily plugged and detached to
isolated signal interface for data exchange and supplies meters which have an external module support. All
the power source to the modem. connection steps are done automatically.
- The meter can connect to the modem such as PLC, GPRS - Pluggable Optical Fiber Port Module: It is designed as
3G-4G –RF Zigbee or Xbee (the products must be an external Optical Fiber Port module. It can be easily
certified Zigbee complained platform as well as Zigbee plugged and detached to meters which have an external
certified product certification), -M-BUS and else. module support. All connection steps are done
- The meter provides AES, SHA-DLMS-HLS-(AES-128- automatically. Pages 14-16-
7
GCM) security. PLC Communication: The meter can have an integrated RF 24-25
- The protocol employed shall use only open system module to support RF communication. Then, it can be
architecture based on publically available international readout and controlled using a Data Concentrator(DC) or a
standards and freely available to any third party. GSM Modem and from LUNA Metrum remotely.
- Meters shall use a protocol that allows it to be No setup or connection is required for PLC communication
automatically detected (Plug and play) when connected on the meter side.
to a communication bus e.g. using IEC 62056, DLMS GPRS Communication Module: The meter can have an
\COSEM under IDIS certificate, or OSGP (the meter must integrated GPRS module to support GPRS communication.
have underground conformance test tool “OCTT” that Then, meter data can be readout and meter can be
have been validated and accepted by NMI certain) controlled from LUNA Metrum remotely over GPRS.
-The communication interface could be modified due to RF Communication: The meter can have an integrated RF
the rapid development in the communication and module to support RF communication. Then, it can be
technology field. readout and controlled using a Data Concentrator(DC) or a
GSM Modem and from LUNA Metrum remotely.
DLMS Communication: The meter supports DLMS
Communication over communication ports.
Firmware upgrade Firmware Upgrade
8 Firmware can be updated locally by optical port as well as LSM meters can optionally support firmware upgrade. Page 25
remotely upgraded in accordance with the Firmware can be updated locally by optical port or can be

Page 2 of 6
DLMS\COSEM or OSGP identification system and updated by remotely with using PLC, RF, GSM or any other
interface classes. communication interface.
Service disconnect \reconnect Latching Relay
- Switch relay ON\OFF 10000 times with Imax current - The electricity of the meter can be
9 Page 18
- The meter can be remotely off & on electricity supply connected/disconnected immediately or at a certain time,
from a central data center. remotely or locally by the latching relay inside the meter.
Load control Auto Disconnect LR on Over Current
- If the overcurrent is higher than the configurable LSM Series meters can optionally support disconnecting
10 Page 20
threshold is detected, the disconnect switch will be the latching relay of the meter in case over current occurs.
disconnected immediately.
Anti-tampering Anti-tampering
- The meter is sealed with no hardware interface or - Magnetic tamper detection is supported.
component exposed. The last 10 intervals when magnetic field is applied and the
- Various anti-tamper events such as terminal cover \ top number of magnetic interventions are stored in the non-
cover opening, magnetic fields disturbance and neutral volatile memory of the meter.
current and balanced can be detected. - There are daily credit loading and loading attempt limits
- When these events happen, alarm will be triggered and in the meter. After too many loading attempts or too many
corresponding events will be recorded. credit loading processes, the meter blocks loading of credit
Page 8
until the next day.
&
- The first main cover opening date and time information is
Page 9
stored in the non-volatile memory of the meter. It can be
&
read by OBIS code “96.70”.
Page 13
11 - LSM series meters can optionally support detection and
&
recording of neutral current events. When the magnitude
Page 19
of the neutral current is measured at least 0.5A greater
&
than the magnitude of the vectorial sum of phase, neutral
Page 22
current event records its beginning time and the neutral
current miss-match icon ‘n’ is blinked on the LCD of the
meter during the event. When the neutral current event
ends, its end time is recorded and its counter is
incremented.
- Buzzer: It is used for audible alarm functions of the meter.
For example if meter terminal cover is removed, meter can
produce alarm tone for a defined period of time if this
feature is turned on.
Calendar and clock Calendar and clock
- Calendar and clock are related to a time control and - all events are related with specified timing, and all events
management system. all data related to data and time, has different sensing time to be able to prevent erroneous
including leap years and deviation of the local time to detection. Page 7
generalized time reference (Greenwich Mean Time - LSM meters support Gregorian, Hijri and Persian &
12 (GMT)), are controlled by this module. Time deviation calendars. All records and calendar events are stored Page 18
between local time and standard time could vary with according to the calendar type. Default calendar of the &
season meter is Gregorian. Page 29
- Real time clock has 0.5 S per day accuracy according to - Real time clock is in compliance with EN62054-21
IEC 62054-21. This clock could be synchronized with HES (former EN 61038) standard. The maximum time deviation
(Head End System) by remote communication. is ±0.5 second daily at 23°C temperature.

Page 3 of 6
- Display format for data information is “DD-MM-YY” - time screen and date screen: is “DD-MM-YY” and for time
and for time is “HH-MM-SS” is “HH-MM-SS”
- In case of power outage, the calendar power will be - The meter operates with one main battery and optional
powered and by an internal super – capacitor and then by secondary battery. The battery / batteries provides
battery whose minimum standby life is over 15 years necessary power supply in case of absence of line power
without any user’s operations. (battery life: Operating: 10 years, shelf: 4 years)
- If the battery is failed or in low level voltage, low battery
icon on LCD screen will flash and this event will be
recorded.
- Load surveys and event logs will always use standard
time for the data stamp.
- If the time is changed for DST (daylight saving time)
start or end, conducts TOU metering function adjusted
time.
Time of use TOU Time of use TOU
- The meter support programmable 2 sets of tariff - Main Tariffs and Tariff Intervals: LSM Series Active-
structure, up to 8 tariffs for maximum demand, kWh and Reactive Electric Electricity Meters are able to split day
kAVh energy, etc. time, and store measurement data for 4 tariffs and 8 billing
- According to IEC 62056-62, active season, week, day periods for weekdays, Saturdays and Sundays separately.
table, tables for different selectable. - Advanced Tariff: LSM meters optionally have advanced
- Each tariff rate programmable for different periods of tariffs structure. 8 different tariff profiles can be defined
the day. for each day in a week and specified holidays.
- User who has sufficient permission can read TOU - Data can be received over the meters via IEC 62056
scheme by communication port. - communication ports are available to readout the meter.
But only the user who has highest security authorization - Eeprom or Flash Ic is used for data backup and log records.
with password can set the TOU scheme.
If the scheme is incorrected programed, such as time set Pages 4-5-6-
13
overlap in same day-ID or tariff exceeds 8, the setting will 7
be rejected.
- The new programmed TOU scheme will be activated at
the designated time, and the meter will immediately
register metering data by the new tariff
- The meters support with calendar clock capability &
memory to support TOU & outage recording functions,
demand management functions, logic capability for
advanced application of integrated disconnect, self-
diagnostic features as well as tamper-evident features &
communication interfacing facility with security features.

Billing Billing
- Only users with correct password can set the billing - Authorized personnel can write only the parameters to
data-time. the meter using the meter password.
14 - Energy and maximum demand - The maximum demand is stored as the maximum demand Pages 5-6
- Consumption and accumulated dept. of the previous month, at the end of each billing period.
Then, this para- meter is cleared by the meter. This process
is done automatically at the end of month, if the

Page 4 of 6
- When the designated data-time arrives, monthly billing maximum demand is not reset manually within that month.
and daily billing would execute according to present LSM series meters stores the maximum demand and date
billing present time. and time of the maximum demand for the last 24 months.
- If a monthly billing happens in power failure, the meter
will execute billing after power restore.
- More than 12 months of billing data for tracking, billing
period is programmable.
- Bidders should also make suggestions on the most
appropriate methods off bill delivery.
Profiles for energy and power quality Load profile
- Up to 8 programmable channels for energy and demand LSM meters store the load profile data in its non-volatile
load profiles storage capacity: 260 days for 1 channel (15 memory for the past 90 days with 15-minute period, 180
15 min period). days for 30-minute period and 360 days for 60-minute Page 6
- Programmable profiles period (typically 5, 10, 30 or 60 period by default. The load profile memory can be extended
minutes). by request to support storing of over 20 years of load
profile data.
Event record Event record
- The meter support more than 20 kinds of event record - Meter Status Recorders: LSM Series Meters have 4
with time stamp. status codes for reading the meter information, errors,
- Power off and power on. disconnected\reconnected warnings and features.
Pages 9-13-
16 remotely locally\locally or over threshold. - Meter logs: Meter keeps logs of various errors and events
24
- Multiple utility controlled password protection with in its non-volatile memory.
access records with both correct and incorrect - password security levels: LSM meters optionally support
Communication module change. multiple password levels for writing parameters to the
meters. Each password level has different purposes.
LED LED
17 - Three LEDs for active energy to be available, reactive - Active Power Consumption LED Page 26
energy and alarm signal output. - Reactive Power Consumption LED
LCD LCD
- The meter has segment type LCD with configurable - LCD Backlight: The backlight is turned on when menu
backlight brightness. button is pressed or optionally on read or write attempt on
- not more than 8 digits display for data display. the meter if electricity is available.
18 - the content display will be clearly indication on the - The meter displays energy data and other parameters on Pages 18-26
nameplate of meter. its 5-integer (optionally 6 integer), 3-decimal digit LCD
screen. It also displays symbols for the notifications
described above. Detailed information about LCD can be
found in the LCD Screen Information section

Technical Specifications
Service Type ( Single-phase two-wire wire (1P2W), Service type: monophase 2 wire meter direct connected.
19 Page 35
Direct Connected )

20 Terminal Connection ( Bottom Connected ) Bottom connected Page 36 & 34

21 Accuracy class :- Class 1 for kWh & Class 2 for kVA/h Accuracy class :- Class 1 for kWh & Class 2 for kVA/h Page 35

Meter Constant :- 1600 imp/kWh (default) Configurable Test output 1000 imp/kWh (default)
22 Page 35
from 1000 imp/kwh to 8000 imp/kwh Configurable meter constant property can be added.

23 Frequency :- 50 Hz ± 5 % Nominal Frequency Hz: 50 Hz ± %2 Page 35

Page 5 of 6
24 Real-time clock :- ≤ 0.5seconds per day (<5 ppm) RTC: ±0.5 seconds daily Page 7

25 Display :- LCD with backlight LCD with backlight Page 18

26 Operating temperature :- -40⁰C ~ 70⁰C Operating temperature :- -40⁰C ~ 85⁰C Page 35

Limited temperature ranges of storage: Limited temperature ranges of storage:


27 Page 35
-40⁰C ~ 85⁰C -40⁰C ~ 85⁰C

28 Relative humidity:- ≤ 95% RH Relative humidity:- 95% Page 35

29 Ingress protection :- IP54 without suction Protection Class: IP54 OUTDOOR Page 35

30 Insulation protection :- Class II Insulation protection :- Class II Page 35

31 Meter life :- (More than 15 years) Meter life +15 years Pages 36

32 Data retention :- >20 years Load profile records up to 20 years Page 36

Battery life :- 15 years (internal built-in battery) - Battery life: (lithium type)
33 Page 35
Lithium type or other advance. Operating 10 years \ shelf 5 years

34 Enclosure material :- Poly carbonate + Glass fiber Raw material: Poly carbonate + Glass fiber Page 36

35 Dimensions :- (142 x 224 x 72) mm Dimensions: 198.90mm \ 123.80 mm\ 77.49mm Page 36

36 Weight :- ≤ 1.1kg Weight: 571 gr Page 35

Input voltage: Voltage:


Nominal Voltage (Un) AC 240V Nominal voltage: 240V
37 Pages 35
Operating voltage 70% ~ 120% Un Operating voltage 70% ~ 120% Un
Power Consumption in voltage circuit :- ≤ 1.5W Power Consumption in voltage circuit :- ≤ 1.5W
Input Current: Current:
Basic Current (Ib) 5 A Nominal current 5(100) A
38 Max. current (Imax) 100 A Starting current 20A Pages 35
Starting current 20 mA Power Consumption in current circuit :- ≤ 0.5 VA
Power Consumption in current circuit :- ≤ 0.5 VA

Page 6 of 6
MONOPHASE SERIES

ELECTRONIC ELECTRICITY METERS


FUNCTIONAL DESCRIPTION V1.0

LUNA ELEKTRİK ELEKTRONİK SANAYİ VE TICARET A.Ş. | A.O.S.B. 10001 Sokak No: 9 Çiğli\İZMİR
Revision History

Version Date Comments

00.01 12.06.2019 First Edition


1. GENERAL FEATURES______________________________________________ 4
1.1. Metrology__________________________________________________________ 4
1.2. Software Version______________________________________________________ 4
1.3. Tariffs_______________________________________________________________ 4
1.3.1. Main Tariffs and Tariff Intervals_______________________________________________ 4
1.3.2. Advanced Tariff (Optional)___________________________________________________ 5
1.3.3. Passive Tariffs (Optional)____________________________________________________ 5

1.4. Maximum Demand_____________________________________________________5


1.5. Load Profile___________________________________________________________6
1.6. Writing Parameters of the Meter_________________________________________ 6
1.7. RTC_________________________________________________________________ 7
1.8. Battery Operation_____________________________________________________ 7
1.9. Logs and Info__________________________________________________________7
1.9.1. Phase Interruptions, Phase Sequence and Reverse Current Detection_________________ 7
1.9.2. Phase Failure Notice________________________________________________________ 8
1.9.3. Phase Active Energy Records_________________________________________________ 8
1.9.4. Main Cover and Terminal Cover Openings_______________________________________8
1.9.5. Advanced Terminal Cover Opening Event (Optional)_______________________________8
1.9.6. RTC Failures_______________________________________________________________8
1.9.7. Magnetic Interventions_____________________________________________________ 9
1.9.8. Production Date___________________________________________________________ 9
1.9.9. Meter Status Recorders_____________________________________________________ 9
1.9.10. Meter Logs_____________________________________________________________ 13

1.10. Optional Integrated Features__________________________________________ 14


1.10.1. Import-Export Energy Measurement_________________________________________ 14
1.10.2. RS485 Communication Port________________________________________________ 14
1.10.3. DLMS Communication____________________________________________________ 16
1.10.4. PLC Communication______________________________________________________ 16
1.10.5. RF Communication_______________________________________________________ 16
1.10.6. GPRS Communication Module______________________________________________ 16
1.10.7. Calendar Support________________________________________________________ 18
1.10.8. kWh Limitation__________________________________________________________ 18
1.10.9. LCD Baclight____________________________________________________________ 18
1.10.10. Latching Relay__________________________________________________________ 18
1.10.11. Non-Volatile Memory____________________________________________________ 18
1.10.12. Buzzer________________________________________________________________ 19
1.10.13. Over- Under Voltage Record______________________________________________ 19
1.10.14. Over Current Record_____________________________________________________19
1.10.15. Auto Disconnect LR on Over/Under Voltage__________________________________ 20
1.10.16. Auto Disconnect LR on Over Current (Consumption Limitation)___________________ 20
1.10.17. Auto Disconnect on Very High Voltage______________________________________ 21
1.10.18. Meter Write Logs_______________________________________________________ 21
1.10.19. Programmable LCD______________________________________________________ 21
1.10.20. Modifiable LCD Fraction__________________________________________________ 22
1.10.21. Relay Output___________________________________________________________ 22
1.10.22. Neutral Measurement___________________________________________________ 22
1.10.23. Demand Reset Button____________________________________________________22
1.10.24. Harmonic Measurement__________________________________________________22
1.10.25. Pulse Outputs__________________________________________________________ 23
1.10.26. External Menu Scroll Button_______________________________________________23
1.10.27. Production Date________________________________________________________ 23
1.10.28. Instantaneous Active Power and Reactive Power______________________________ 23
1.10.29. Prepayment___________________________________________________________ 23
1.10.30. Password Security Levels_________________________________________________ 24
1.10.31. Pluggable Module Support________________________________________________ 24
1.10.31.1. Pluggable PLC Module________________________________________________ 25
1.10.31.2. Pluggable RF Module_________________________________________________ 25
1.10.31.3. Pluggable GSM Module_______________________________________________ 25
1.10.31.4. Pluggable Ethernet Module____________________________________________25
1.10.31.5. Pluggable Optical Fiber Port Module_____________________________________25
1.10.32. Firmware Upgrade______________________________________________________ 25

2. OPERATING ELEMENTS___________________________________________26
3. SECURITY NOTICES______________________________________________ 27
4. LCD SCREEN INFORMATION_______________________________________ 27
5. MENUS_______________________________________________________ 28
6. PHYSICAL DIMENSIONS OF THE METER______________________________ 33
7. CONNECTIONS_________________________________________________ 34
8. GENERAL MECHANICAL SCHEME___________________________________ 34
9. TECHNICAL SPECIFICATIONS_______________________________________35
MANUFACTURER INFORMATION:
LUNA ELEKTRİK ELEKTRONİK SAN. VE TİC. A.Ş.
10001 Str. No:9 Atatürk O.S.B.
35620 Çiğli / İzmir - TÜRKİYE
Tel: +90 232 472 15 45 Fax: +90 232 472 15 50
www.lunatr.com

SERVICES:

Main Technical Service:


LUNA ELEKTRİK ELEKTRONİK SAN. VE TİC. A.Ş.
10001 Str. No:9 Atatürk O.S.B.
35620 Çiğli / İzmir - TÜRKİYE
Tel: +90 232 472 15 45 Fax: +90 232 472 15 50

1
ATTENTION
READ THE MANUAL CAREFULLY BEFORE
OPERATING THE METER
The assembly of LSM Series Active-Reactive Single Phase meter should be
in accordance with to the connection schemes in the manual and exe- cuted
by authorized personnel. Otherwise, the warranty does not cover any
damage costs to the meter.
The compatibility of the meter to the energy lines and facility where as-
sembly takes place should be verified by authorized personnel. Incorrect
meter choice and connection damages the meter. Such meters are out of
warranty cover.
LUNA Electronic Electricity Active Meters have five (5) year warranty co-
vering any manufacturing defects. In case of intervention by any individual
or organization apart from authorized personnel defined by Central Meter
Calibration Station, the warranty will be void.
Defects due to misuse of determined technical features in user’s manual of
LUNA Electronic Electricity Meters (usage out of range set in the manual)
are not considered under cover of warranty.
LSM Series Active-Reactive Multi Tariff Single Phase Electronic Electricity
Meters are, Hardware and software of, designed by R&D department of
LUNA and manufactured by itself.
LSM Series Active-Reactive Single Phase Electronic Electricity Meters sa-
tisfies the requirements of 2004/22/AT Measuring Tool Article, EN 50470
standards.
LUNA ELEKTRIK ELEKTRONIK SAN. and TIC. A.S has no liability if the
operating instructions in the manual are not complied.
In the following cases warranty will be void
Warranty is void if seals of LUNA ELEKTRIK ELEKTRONIK SAN. and TIC.
A.S are broken.
Damages to the mechanical and electronical structure of the meter due to
external interference are out of warranty cover.
All physical damage during the mounting of the meter (fractures, cracks) are
out of warranty cover.
All damages caused during mounting by unauthorized personnel is out of
warranty cover.
2
INTRODUCTION
General Safety Precautions
SEALS AND SCREWS OF ELECTRONIC ELECTRICITY METERS, SEALED
BY LUNA ELEKTRIK ELEKTRONIK SAN. and TIC. A.S AND ELECTRIC
DISTRIBUTION COMPANY, MUST BY NO MEANS BE OPENED, EXCEPT
FROM AUTHORIZED PERSONNEL, AFTER BEING ENERGIZED.
• The mounting of the meter should be executed by expert personnel
provided with technical information in accordance with connection schemes
and safety regulations in the manual.
• There’s danger of electric shock in live electronic electricity meters
connector covers and near the electricity board where connection is made.
• Energy should be turned off during mounting and demounting of the meter.
• For longer life and smooth usage of the mounted Electronic Electricity
Meter board regulations defined by the electricity distribution company must
be complied. Humidity, direct exposure to sunlight, rain and cold should be
avoided.
• As electricity measurement are performed using electronic components, to
avoid any damage, no physical impact should be applied to the meter.
• Despite having OUTDOOR feature, LSM40 Active-Reactive Three Phase
Electronic Electricity meters should by no means be exposed to immersion.
Outer surfaces of the meters should be cleaned by solvents.
• All meters are calibrated in accordance with defined articles and regulations.
No other routine maintenance by the client is necessary.
• Meters by no means should be opened by the user and interve- ned for
repair.
• Optical port interface on the meters should only be used for data transfer
set by electric distribution company regulations.
• Although humidity and temperature are not a concern during storage, it is
not advised to keep the meters at maximum values of these parameters.

3
1.GENERAL FEATURES
1.1.Metrology
LSM Series Active-Reactive Electric Electricity Meters can measure and
record active import energy. Voltage and current measurement, and energy
calculation is carried out by the microprocessor in the meter. If energy is in
reverse direction, the import meter takes its absolute value and assumes it as
positive. The import-export meter, however, measures and stores the data of
import and export energy separately. Additionally, reactive energy, apparent
energy can also be measured and recorded. Program memory is fully
protected for fraud attempts and tamper with the program code.

LSM series capable of measuring;


- Active energy in all 4 quadrants as import energy or import/export energy.
- Reactive energy in all 4 quadrants as reactive import energy or reactive
import/export energy
- Total import and export active power, total import and export reactive power.
Calculation period is programmable.
- Instantaneous voltage, current, active power, reactive power, apparent power,
power factor, frequency for each phase or total three phase.
- Reactive energy of Q1+Q2 and Q3+Q4 quadrants. (3.8.0 and 4.8.0)

1.2. Software Version


Meter Software version can be readout from e-meter via OBIS code 96.97.

1.3. Tariffs
1.3.1. Main Tariffs and Tariff Intervals
LSM Series Active-Reactive Electric Electricity Meters are able to split day
time, and store measurement data for 4 tariffs and 8 billing periods for
weekdays, Saturdays and Sundays separately. The measured energy is
added to both total tariff (T) and the corresponding tariff (T1, T2, T3 or T4).
The tariff information can be viewed on LCD or read out using the OBIS
codes from 1.8.0 to 1.8.4 (import) and from 2.8.0 to 2.8.4 (export**) in the
format: (000000.000*kWh)
1.8.0 and 2.8.0 gives the total tariff (T) information and 1.8.1,... ,1.8.4 and
2.8.1,..., 2.8.4 gives T1, T2, T3, T4 information of import energy and export
energy respectively.

4
At the end of each month, T, T1, T2, T3 and T4 data is automatically stored
in the non-volatile memory of the meter as the previous month’s record. Last
24 months’ data is always stored in the non-vo- latile memory automatically.
The previous months’ tariff data can be read using OBIS codes from 1.8.1*1
to 1.8.4*24 (import) and from 2.8.1*1 to 2.8.4*24 (export**). For instance,
1.8.1*1 OBIS code corresponds to the previous month’s Import Tariff 1
record; the last 24 month’s Import T1 parameter can be read with OBIS
codes from 1.8.1*1 to 1.8.1*24.
Tariff intervals are pre-programmed as follows Tariff 1: 06:00 - 17:00
Tariff 2: 17:00 - 22:00
Tariff 3: 22:00 - 06:00
Tariff 4: -
Automatic daylight saving is active by default. It can be disabled using the
OBIS code 96.98(10) and re-enabled with 96.98(00).
In case extra intervals or tariff changes are needed, it can only be performed
by authorized personnel using optical port interface.

1.3.2. Advanced Tariff (Optional)


LSM meters optionally have advanced tariffs structure. 8 different tariff
profiles can be defined for each day in a week and specified holidays.
Likewise, 8 different season profiles can be defined and 4 different weekly
profiles can be defined for seasons. Different tariffs can be assigned for each
day in a week. Unlimited holidays can be defined for the next 10 years.

1.3.3. Passive Tariffs (Optional)


Passive tariffs are used in order to change the used tariffs structure after a
certain date. LSM meter reading software is used to create and write the
passive tariffs structure, in the same format as the active advanced tariffs
structure. In addition to the passive tariffs structure, the activation date needs
to be written for the passive tariffs to be activated when required. Once the
time of activation comes, the passive tariffs are overwritten to the active
tariffs in the memory of the meter, and the passive tariffs data and the
activation date are deleted.

1.4. Maximum Demand


The maximum demand is stored as the maximum demand of the previous
month, at the end of each billing period. Then, this para- meter is cleared by
the meter. This process is done automatically at the end of month, if the
maximum demand is not reset manually within that month. LSM series meters
stores the maximum demand and date and time of the maximum demand for
the last 24 months. The current value of maximum demand and its date and

5
time can be viewed on LCD or read out using the OBIS codes 1.6.0 (import)
and
2.6.0 (export). The previous months’ information can be read out with the OBIS
codes from 1.6.0*1 to 1.6.0*24 (import) and from 2.6.0*1 to 2.6.0*24 (export).
The maximum demand information is read in the following format
(000.000*kW)(YY-MM-DD,HH:mm)

1.5. Load Profile


LSM meters store the load profile data in its non-volatile memory for the past
90 days with 15 minute period, 180 days for 30 minute period and 360 days for
60 minute period by default. The load profile memory can be extended by
request to support storing of over 20 years of load profile data.
The meter recognizes the following format:
<SOH>R5<STX>P1(YYMMDDHHmm;YYMMDDHHmm)()<ETX><BCC>
and responds in the following format:
<STX>R5(XX)
(YYYY-MM-DD)(HH:MM)(XXXXXX.XXX*kWh)
(YYYY-MM-DD)(HH:MM)(XXXXXX.XXX*kWh)
...
<ETX><BCC>

1.6. Writing Parameters of the Meter


Authorized personnel can write only the following parameters to the meter
using the meter password:

 Meter Date
 Meter Time
 Meter Day of the Week
 Tariff Intervals
 Tariff Hours
 Maximum Demand Period
 Load Profile Period
 Automatic Daylight Saving Parameter
 New Password
Other than the parameters above, none of the meter parameters can be
changed in any way.

6
1.7. RTC
RTC is in compliance with EN62054-21 (former EN 61038) standard. The
maximum time deviation is ±0.5 second daily at 23°C temperature.

1.8. Battery Operation


The meter operates with one main battery and optional secondary battery. The
battery / batteries provide necessary power supply in case of absence of line
power. Battery powered supply allows the meter to be awaken with Menu
Button in the absence of phase energy. While the LCD is on, the meter data
can be viewed on the LCD, or can be read out using optical port.
The battery condition can be read by OBIS code “96.6.1”. The data in the
response from the meter is:
96.6.1(0) : battery is empty,96.6.1(1) : battery level is OK.

1.9. Logs and Info


Eeprom or Flash Ic is used for data backup and log records. The meter keeps
logs of the following information in its non-volatile memory:
1.9.1. Phase Interruptions, Phase Sequence and Reverse
Current Detection
The start and end-time of phase interruptions are stored in the non-volatile
memory of the meter. The meter records the date and time of last 10 phase
interruptions. The number of total phase interruptions and the total phase-off
duration can be read by OBIS code “96.7.1” and 96.77.11 respectly, the date
and time information of last 10 phase interruptions can be read by OBIS
codes from “96.77.1*1” to 96.77.1*10”.

Three phase meters check phase sequence continuously. If phase sequence


is not correct then it is shown on LCD. In this state L1L2L3 segments blink
continuously. Event start date and time are recorded to related obis code.
Event finish date and time will be recorded when the phase sequence are
fixed and three phase applied to meter. . Related obis codes can be found on
Obis Code List.

Three phase meters detect if any phase is connected to neutral input of


meter instead of phase input. In this state related phase segment (L1, L2 or
L3) blinks continuously. Authorized personnel needs to change neutral line
cable and blinking line to be able to get the right connection.

7
Meters are able to sense current direction. If one or more phases have
reverse current then start date and time of this event is recorded to related
obis code. In this state, reverse current is shown on LCD and related line
current segments blink continuously. Event finish date and time will be
recorded when related phase currents are positive. Related obis codes can
be found on Obis Code List.

Please note that all events has different sensing time to be able to prevent
erroneous detection.

1.9.2. Phase Failure Notice


If there is no consumption record on any phase for 30 days, phase failure
message is received. For this failure 98.11 OBIS code is used.

1.9.3. Phase Active Energy Records


Total active energy consumed from ever phase is measured and re- corded
separately. This value is shown on the screen for every phase. These values
are hold by OBIS code and can be taken through the optic port. OBIS codes
used for these values:
For active power hold from L1 phase: 21.8.0 For active power hold from L2
phase: 41.8.0
For active power hold from L3 phase: 61.8.0

1.9.4. Main Cover and Terminal Cover Openings


The first main cover opening date and time information is stored in the
non-volatile memory of the meter. It can be read by OBIS code
“96.70”.Terminal cover opening date and time of current and past 24 months
are recorded in the non-volatile memory. The current information can be read
by OBIS code “96.71” and the past information can be read by OBIS codes
from “96.71*1” to “96.71*24”. Main cover and terminal cover detection is also
possible when the power is not applied to meter.

1.9.5. Advanced Terminal Cover Opening Event (Optional)


The last 30 terminal cover opening events in the last month are recorded
along with the date and time of occurence. The current record can be read
by 96.91 OBIS code, while the previous month’s records are read using
96.91*1,. ,96.91*12 OBIS codes.

1.9.6. RTC Failures

8
When RTC failure occurred, a clock icon is displayed on the LCD. In this
failure condition, the meter only records to T1 tariff. The icon disappears and
the fault is cleared when date and time information is written to the meter.
The meter can optionally display a constant message on its screen in this
case unless the menu button is pressed and auto scrolling is off.

1.9.7. Magnetic Interventions


The last 10 intervals when magnetic field is applied and the number of
magnetic interventions are stored in the non-volatile memory of the meter.
The number of magnetic interventions can be read by OBIS code “96.80”
and the date and time information of last magnetic interventions can be read
by OBIS codes from “96.80*1” to 96.80*10”.

1.9.8. Production Date


The production date is stored in the memory and can be read with OBIS
code “96.1.3”.

1.9.9. Meter Status Recorders


LSM Series Meters have 4 status codes for reading the meter information,
errors, warnings and features. The statuses have the following OBIS codes:
F.F.0: Critical Meter Errors F.F.1: Warnings
F.F.2: Meter Information F.F.3: Meter Features
Each status has a structure in the form of FFFFFFFFh. One F cor- responds
to 4 bits in binary and each bit is either 1 or 0. The meaning of each bit which
is set is described below:
From right to Left (LSB to MSB):
F F F F F F F F → 1111 1111 1111 1111 1111 1111 1111 1111
STATUS0:
1: meter time was/is invalid
1: rtc module error occured
1: meter is uncalibrated
1: reserved

1: soft reset occured


1: hard reset occured
1: reserved
1: meter supply is out of range

1: error in metrology current measurement section


1: error in metrology voltage measurement section

9
1: communication error with metrology IC
1: fatal metrology error occured

1: checksum error occured within consumption data


1: checksum error occured within 1st backup of consumption data
1: flash memory write error occured
1: other fatal errors occured

1: external memory error occured


1: reserved
1: PLC module error occured
1: RF module error occured

1: RS485 port error occured


1: meter is locked to any intervention
1: reserved
1: reserved

1: extremely high demand value recorded


1: extremely high energy consumption recorded
1: reserved
1: reserved

1: general system error occured


1: reserved
1: reserved
1: reserved
STATUS1:
1: over voltage is applied on at least one of the phases of the meter currently
1: under voltage is applied on at least one of the phases of the meter currently
1: over current is drawn by the consumer currently
1: the current on at least one of the phases is reversed

1: phase sequence is correct


1: phase R is on
1: phase S is on
1: phase T is on

1: phase RST off event started


1: phase R off event started
1: phase S off event started
1: phase T off event started

10
1: active energy limit reached
1: reactive energy limit reached
1: at least one of the phase currents in the poly-phase meter is unbalanced with respect to the average
current of all phases
1: at least one of the phase voltages in the poly-phase meter is unbalanced with respect to the average
voltage of all phases

1: 00 = battery 1 empty, 01 = battery 1 level low, 11 = battery 1 level good


1:
1: 00 = battery 1 empty, 01 = battery 1 level low, 11 = battery 1 level good
1:

1: maximum demand limit exceeded


1: reactive energy consumption limit exceeded
1: considerable amount of neutral current is drawn
1: reserved

1: tariff settings are written to the meter


1: date/time is written to the meter
1: other parameter is written to the meter
1: reserved

1: reserved
1: reserved
1: reserved
1: reserved
STATUS2:
1: parameter(s) written to the meter locally
1: parameter(s) written to the meter remotely
1: meter time synchronized locally
1: meter time synchronized remotely

1: Main cover of the meter is currently open


1: Main cover of the meter has been opened
1: Terminal cover of the meter is currently open
1: Terminal cover of the meter has been opened

1: Strong magnetic field is currently being applied


1: Strong magnetic field has been applied
1: reserved
1: reserved

11
1: Latching relay is connected
1: Latching relay status has been changed
1: Latching relay error occurred
1: reserved

1: PLC module is connected to the PLC network


1: RF module is connected to the RF network
1: reserved
1: reserved

1: reserved
1: reserved
1: reserved
1: reserved

1: reserved
1: reserved
1: reserved
1: reserved

1: reserved
1: reserved
1: reserved
1: reserved
STATUS3:
1: RS485 communication is supported
1: RF communication is supported
1: PLC communication is supported
1: Plug&Play communication module is supported

1: Latching Relay is supported


1: EEPROM is supported
1: SPI flash is supported
1: Software upgrade is not supported

1: Export energy measurement feature is enabled


1: Reactive energy measurement is supported
1: Load Profile recording is supported
1: reserved

1: LCD backlight is supported


1: Advanced phase interruptions feature is supported.

12
1: Holiday tariff feature is supported
1: LCD sub-menu is supported

1: Advanced log feature is supported


1: DLMS communication is supported
1: If 1, 10000 impulse mode; if 0, 1000 impulse mode
1: reserved

1: reserved
1: reserved
1: reserved
1: reserved

1: Over and under voltage detection are supported


1: Over current detection is supported
1: Magnetic tamper detection is supported
1: Daylight saving time feature is enabled

1: reserved
1: reserved
1: reserved
1: reserved

The statuses can also be easily read with the LSM meter reading software
using the Status tab. After reading the statuses, the bits which are set appear
in bold on the left with their meanings. Note that, some of the status bits
may not be available in all meter models.
Optionally, the meter status registers can also be displayed on the LCD.

1.9.10. Meter Logs


Meter keeps logs of various errors and events in its non-volatile me- mory.
These logs can be read using 96.75*1(00),..., 96.75*150(00) OBIS codes.
The log data is in (YY-MM-DD,hh:mm:ss |<error code>) format.
The complete logs can be read by asking the meter 96.75*X(00) OBIS code
starting with X as 1, and incrementing X until an empty log data (--------,--: |--)
is received or X reaches 150. The basic error codes
are as follows:
01: Current energy consumption values inconsistent
02: Extreme energy consumption value measured
06: Meter is initialized
07: Hard reset occured
08: Soft reset occured
13
12: EEPROM write error
16: Meter is programmed
19: RF module malfunctioned
20: PLC module malfunctioned
24: Battery 1 level dropped to critical level
25: Battery 2 level droped to critical level
33: Error reading time backup
35: Load profile structure error
38: RTC module malfunctioned
40: Flash memory write error
50: Meter firmware upgraded
51: SPI Flash write error
52: Total energy consumption value increased too much in a short time.

1.10. Optional Integrated Features


1.10.1. Import-Export Energy Measurement
LSM series meters can optionally measure energy bi-directionally. The
measured export energy is recorded apart from the import tariffs and added
to the total export active tariff -T and the corresponding export tariff from -T1,
-T2, -T3, -T4. The export reactive consumptions are also recorded
separately from the import reactive consumptions and added to the -Ri, -Rc
export reactive tariffs. The export energy in- formation can be viewed on the
LCD following the related OBIS codes (2.8.0, ..., 2.8.4, 7.8.0, 6.8.0). Export
-T, -T1, -T2, -T3, -T4, -Ri (inductive), -Rc (capacitive) consumptions have
OBIS codes of 2.8.0, 2.8.1, 2.8.2, 2.8.3, 2.8.4, 7.8.0, 6.8.0 respectively. The
export measurement values are displayed with a negative (-) sign to the left
(-T, -T1, -T2,-T3, -T4, -Ri, -Rc).
Export measurement feature can be turned on by writing 1 or turned off by
writing 0 to 96.74.18 OBIS code. After export feature is disabled or enabled,
the past load profile data is erased. If export feature is enabled, import and
export consumptions are recorded; however, if export feature is disabled,
only the import consumption is recorded, which significantly increases the
maximum number of records the load profile can hold compared to
import-export.

1.10.2. RS485 Communication Port


In case there is only one meter connected to the data line, the meter can be
readout using the format “/?!CRLF” via RS485 protocol. On the other hand, if
multiple meters are connected to the same data line, the meters can be read

14
individually using the format “/?XXXXXXXX!CR- LF” where XXXXXXXX is
the serial number of the meter to be readout.

15
1.10.3. DLMS Communication
The meter supports DLMS Communication over communication ports.

1.10.4. PLC Communication


The meter can have an integrated PLC module to support PLC com-
munication. Then, it can be readout and controlled using a Data Con-
centrator(DC) and from LUNA Metrum remotely.
The PLC module uses CENELEC A band and DCSK modulation for power
line communication. It supports communication speed of up to 2.5kbps.
No setup or connection is required for PLC communication on the meter
side.

1.10.5. RF Communication
The meter can have an integrated RF module to support RF communication.
Then, it can be readout and controlled using a Data Concentrator(DC) or a
GSM Modem and from LUNA Metrum remotely.
The RF module uses 868MHz ISM band and a custom protocol by LUNA
meters for communication. It supports communication speed of up to
200kbps.
No setup or connection is required for RF communication on the meter side.

1.10.6. GPRS Communication Module


The meter can have an integrated GPRS module to support GPRS
communication. Then, meter data can be readout and meter can be
controlled from LUNA Metrum remotely over GPRS.
Hardware specifications:
•Quad-Band GSM/GPRS /EDGE GSM850/ GSM900/ DCD1800/
PCS1900Mhz
•GPRS-EDGE connection: Multi-slot class 12, Mobile station class B
Dynamic IP and Static IP compatible
•4MB (upgradable upon request) non-volatile memory Local USB port
(optional)
•GSM Module control with external microprocessor
•Automatic GSM Module control and reset (Soft-reset and Hard-reset)

16
•1 Relay output 10A/250VAC (optional)
•External GSM antenna
•Opportunity to use internal and external box aerial. High receiver power
•By local meter reading feature; opportunity of Modem and meter connection
control on site (optional)
•Reading other meters through RS485 (optional) Software specifications:
•Compatible with various AMR software. JSON , XML communication
protocol support
•Full control and software update remotely or from USB port, locally
•Opportunity to authorize modem for task of reading 120 meters
•Interior task handler, Recording 50 OBIS packet on modem.
•Defining remotely and locally connection parameters
•Data compaction and enciphering feature (optional)
•lntegrated RTC module
•Finding position automatically through surrounding base stations (patented}
•Receiving time clock automatically from connected base station (patented}
•lnstant, periodic, repetitive scheduled task running feature Remotely exit
control
•Log records
•Notices tor instant meter and modem alarm
USB output for local connection and RS485 connection tor reading
various meters beside available meter, is presented as optional and
attached if requested.
SIM Card input of GSM/GPRS module integrated on LSM series meter
and external RS485 connection are located under meters’ terminal cover
and preserved by seal to avoid unauthorized interference.
external aerial, mili run aut and RS485 connection are located under
meters’ terminal cover and preserved by seal to avoid unauthorized
interference.

Antenna

17
1.10.7. Calendar Support
LSM meters support Gregorian, Hijri and Persian calendars. All records and
calendar events are stored according to the calendar type. Default calendar
of the meter is Gregorian.

1.10.8. kWh Limitation


If the meter includes this feature, it is activated by default. It can be disabled
by writing 0 or re-activated by writing 1 to 96.74.22 OBIS code. When the
subscriber reaches the monthly consumption limit defined in 96.73.30 OBIS
code, the subscriber’s electricity will be disconnected if the feature is enabled.
If the Consumption Limitation Repeat (96.74.24) feature is enabled (value 1),
the electricity can be reconnected for Allowed Button Connect Count
(96.73.33) times by pushing the menu button of the meter. The limit is reset
at the end of each month.

1.10.9. LCD Baclight


The backlight is turned on when menu button is pressed or optionally on read
or write attempt on the meter if electricity is available.

1.10.10. Latching Relay


The electricity of the meter can be connected/disconnected immediately or
at a certain time, remotely or locally by the latching relay inside the meter.
The latching relay state can be changed by the below OBIS code and data
through optical port/RS485/smart communication mo- dule.
96.74(0X)(YY-MM-DD)(000000)
{
{

Opareting Date Operator


Optional ID Optional
where X = 0 for connect or X = 1 for disconnect operation. Entering an
operator ID is optional. Additionally, if the latching relay is to be connected
immediately, there is no need to enter an action time while writing the OBIS;
while, a date-time of operation can be written as in the above format if
needed.

1.10.11. Non-Volatile Memory


For higher memory requirements the meter may have addtional non-volatile
memory IC.

18
1.10.12. Buzzer
It is used for audible alarm functions of the meter. For example if meter
terminal cover is removed, meter can produce alarm tone for a defined
period of time if this feature is turned on.

1.10.13. Over- Under Voltage Record


LSM series meters can optionally support detection and recording of over
voltage and under voltage events. When instant voltage exceeds the defined
over voltage parameter (96.73.20) value or falls below the defined under
voltage parameter (96.73.21) value, over voltage or under voltage event
records the beginning time of the respective event. When the over or under
voltage condition ends, the end time of the respective event is recorded and
the counter and total duration of that event are updated. The start-end time
of over voltage and under voltage events can be read using the OBIS codes
of 96.77.30*1,...,12 and 96.77.40*1,...,12 respectively. The total number and
duration of over voltage events can be read with OBIS codes of 96.77.30 and
96.77.31, whereas those of under voltage events can be read using the
OBIS codes of 96.77.40 and 76.77.41 respectively.
All of the Over Voltage and Under Voltage parameters can be changed
through Features tab of the meter reading software. The parameters related
to over and under voltage events that can be changed are as follows:
val_ov(96.73.20): The value of voltage over which over-voltage is detected
val_uv(96.73.21): The value of voltage below which under-voltage is
detected
ouv_record_delay(96.73.24): the minimum duration of an over/under
voltage event to start or end recording.

1.10.14. Over Current Record


LSM series meters can optionally support detection and recording of over
current events. When instant current exceeds the defined over current
parameter (96.73.22) value, over current event records the beginning time of
the event. When the over current condition ends, the end time of the event is
recorded and the counter and total duration of the event are updated. The
start-end time of over current events can be read using the OBIS codes of
96.77.50*1,...,12. The total number and duration of over current events can
be read with OBIS codes of
96.77.50 and 96.77.51 respectively.
All of the Over Current parameters can be changed through Features tab
of the meter reading software. The parameters related to over current
events that can be changed are as follows:
val_oi(96.73.22): The value of current over which over current is detected

19
oi_record_delay(96.73.24): the minimum duration of an over current event to
start or end recording.

1.10.15. Auto Disconnect LR on Over/Under Voltage


LSM Series meters can optionally support disconnecting the latching relay of
the meter in case over/under voltage occurs. If this feature is supported in
the meter, feat_lr_auto_ouv_err(96.74.20) OBIS code can be read or written
to. The descriptions of the related OBIS codes for this feature are as below:
feat_lr_auto_ouv_err(96.74.20): if 0, auto disconnecting on over/ under
voltage is disabled; if 1, auto disconnects on over/under vol- tage and
connects back at nominal voltage for counter_lr_auto_ ouv(96.73.23) times
and then doesn’t reconnect after the next discon- nection on over/under
voltage; if 2, auto disconnects on over/under voltage and connects back at
nominal voltage without limit; if 3, auto disconnects on over/under voltage
and connects back at nominal voltage for counter_lr_auto_ouv (96.73.23)
times and then doesn’t disconnect after that.
counter_lr_auto_ouv(96.73.23): the number of times the meter is
disconnected or connected if feat_lr_auto_ouv_err (96.74.20) is 1 or 3
dur_lr_auto_ouv_err(96.73.26): the event duration after which the
latching-relay of the meter will be disconnected if feat_lr_auto_ouv_
err(96.74.20) is not 0 or limit is not reached in limiting modes (1 and 3)
feat_lr_reset_limit_endofmonth(96.74.21): If this feature is enabled (value
1), the number of times the meter was disconnected/connected is reset and
the blocking of lr is removed at the end of every month. Additionally, if a
manual disconnection (by optical port or remotely) is issued, the over/under
voltage event cannot reconnect the lr until the end of the month if this feature
is enabled.

1.10.16. Auto Disconnect LR on Over Current (Consumption


Limitation)
LSM Series meters can optionally support disconnecting the latching relay of
the meter in case over current occurs. If this feature is supported in the meter,
feat_lr_auto_oi_err(96.74.21) OBIS code can be read or written to. The
descriptions of the related OBIS codes for this feature are as below:
feat_lr_auto_oi_err(96.74.21): if 0, auto disconnecting on over current is
disabled; if 1, auto disconnects on over current and con- nects back after
dur_lr_off(96.73.29) seconds for counter_lr_auto_ oi(96.73.37) times and
then doesn’t reconnect after the next disconnection on over current; if 2, auto
disconnects on over current and connects back after dur_lr_off(96.73.29)
seconds without limit; if 3, auto disconnects on over current and connects
back after dur_lr_ off(96.73.29) seconds for counter_lr_auto_oi(96.73.37)
times and then doesn’t disconnect after that.
counter_lr_auto_oi(96.73.37): the number of times the meter is dis-
connected or connected if feat_lr_auto_oi_err(96.74.21) is 1 or 3
20
dur_lr_auto_oi_err(96.73.27): the event duration after which the
latching-relay of the meter will be disconnected if feat_lr_auto_oi_
err(96.74.21) is not 0 or limit is not reached in limiting modes (1 and 3)
feat_lr_reset_limit_endofmonth(96.74.21): If this feature is enabled (value
1), the number of times the meter was disconnected/connected is reset and
the blocking of lr is removed at the end of every month. Additionally, if a
manual connection (by optical port or remotely) is issued, the over current
event doesn’t disconnect the lr until the end of the month; if a manual
disconnection is issued, the lr stays dis- connected forever until the next
manual connection command if this feature is enabled.

1.10.17. Auto Disconnect on Very High Voltage


If this feature is supported in the meter, 96.74.26 OBIS code can be read or
written to. If this feature is supported and enabled in the meter (value 1),
when more than 320V is applied to the monophase meter for 3 seconds, the
meter disconnects its latching relay to protect the consumer’s devices. It
reconnects its latching relay if less than 320V is applied to the monophase
meter for 3 seconds.
This feature works independently from Over/Under Voltage Record feature.
Moreover, this feature overrides Auto Disconnect LR on Over/ Under Voltage
(96.74.20) feature. In other words, if both features (96.74.26 and 96.74.20)
are enabled, 96.74.26 feature will be used; whereas, if 96.74.26 is disabled
(value 0) and 96.74.20 is enabled (value 1), 96.74.20 feature will be used.

1.10.18. Meter Write Logs


LSM series meters can keep logs of the writings to the meter, along with their
date-time, password level, operator id and OBIS code including its data. The
writing log is read in (YY-MM-DD,
hh:mm|A1|000000|<OBIS code with data>) format, where A is the password
level (0,1,2).
The complete writing logs can be read by asking the meter 96.92*X(00)
OBIS code starting with X as 1, and incrementing X until an empty writing log
data (00-00-00,00:00|00|000000) is received.

1.10.19. Programmable LCD


LSM series meters have an optional feature that allows configuration of lcd
pages as desired. The customer can select which OBIS code values to
display on LCD in which order. The Programmable LCD tab in LSM GUI
software is used to define the lcd pages by entering their OBIS codes in
desired order, seperately for main menu and sub menu.
Contact the manufacturer to request non-standard OBIS codes to be
displayable on LCD.

21
1.10.20. Modifiable LCD Fraction
The number of integers and decimals displayed on LCD for consumption
data can optionally be modified using the OBIS code 96.90.7(XY), where X
is number of integers and Y is number of decimals to display.

1.10.21. Relay Output


A relay output is available if requested. It can be opened or closed by
96.74.1 obis code. Relay has two output connector on meter cover. These
are NO or NC and COMMON relay pins. If relay is switched on then output
connectors will be in closed or open state. The relay has two output
connectors on meter cover as NO and COMMON relay pins. The relay can
be switched on or off by writing 1 or 0 to 96.74.1 OBIS code, respectively.

1.10.22. Neutral Measurement


LSM series meters can optionally support detection and recording of neutral
current events. When the magnitude of the neutral current is measured at
least 0.5A greater than the magnitude of the vectorial sum of phase, neutral
current event records its beginning time and the neutral current miss-match
icon ‘n’ is blinked on the LCD of the meter during the event. When the neutral
current event ends, its end time is recorded and its counter is incremented.
The start-end time of neutral current events can be read using the OBIS
codes of 96.77.9*1,...,10. The total number of neutral current events can be
read with OBIS code of 96.77.60.

1.10.23. Demand Reset Button


Manually performs month-end operations, resets demand. With this button,
the past month information about invoice periods can be given. Example
1.8.1 * 1 The OBIS value indicates the T1 consumption rate for the previous
invoice period.
If any manual reset is not performed inside a month then automatic demand
reset occurs at the end of the month. Tx tariff values are recorded as
previous month parameters, actual demand value, date and time also
recorded as previous month demand parameters, then actual demand value,
date and time is set to zero for new month record.
In addition, month end operations can be performed with optical port or
remote communication. The user who has security authorization with
password can perform execution of month end operations via optical port
interface or remote communication interface.

1.10.24. Harmonic Measurement


LSM series meters can optionally measure the total harmonic distortion
(THD) for voltage and current. The voltage THD values for R, S, T phases
22
have OBIS codes of 32.7.1, 52.7.1, 72.7.1; the current THD values for R, S,
T phases have OBIS codes of 31.7.1, 51.7.1, 71.7.1 respectively. They can
be read by their corresponding OBIS codes and can optionally be displayed
on the LCD of the meter.

1.10.25. Pulse Outputs


Pulse outputs are Opto-isolated. The output is connected to fully isolated two
terminals of the meter. + is connected to A terminal and - is connected to the
B terminal.
Monophase meters have 1 active pulse output, three-phase meters have 1
active and 1 reactive pulse output by default.
Pulse Output is configured as 500p/kWh (2Wh/Pulse) by default. It can be
factory programmed to a different value by request of the customer.

1.10.26. External Menu Scroll Button


The meter has the internal menu button and an external menu button output.
External menu output is used for remote menu switching if the meter is
mounted in a place difficult to reach.

1.10.27. Production Date


The production date of the meter can be read with OBIS code of 96.1.3. The
year of production can optionally be displayed on the LCD with the same
OBIS code.

1.10.28. Instantaneous Active Power and Reactive Power


Absolute instantaneous active and reactive power can optionally be
displayed on the LCD sub menu. For three phase meters, absolute
instantaneous active power for phases R, S and T are displayed with OBIS
codes of 35.7.0, 55.7.0 and 75.7.0 respectively. If the three pha- se meter
has reactive measurement support, absolute instantaneous reactive power
for phases R, S and T are also displayed with OBIS codes of 37.7.0, 57.7.0
and 77.7.0 respectively.

1.10.29. Prepayment
LSM meters support prepayment feature which requires the subscriber to
load credit into the meter in order to use electricity. If the meter doesn’t have
any credit loaded in it or if the credit in it is used up, the internal relay of the
meter will power off the electricity of customer. The relay will be activated
again if credit is loaded again to the meter.

23
Prepayment feature in meters can be activated or deactivated by encrypted
writing to the meter. If prepayment feature is disabled, the relay of the meter
turns on electricity of subscriber. If the prepayment feature of the meter is
enabled, the meter must be loaded not to power off electricity.
The credit is loaded or called back with AES encryption using PC software or
remotely from HES in either kWh or currency format. The credit is loaded
together with the current unit price value. The meters with prepayment
feature allow calling back the whole or partial amount of credit within the
meter.
The total amount of credit in the meter can be read in kWh or currency format
with OBIS code of U.1.10 or U.1.13 respectively. The current unit price
written in the meter is read with OBIS code of U.1.40. The current credit and
unit price are displayed on the LCD of the meter.
There are daily credit loading and loading attempt limits in the meter. After
too many loading attempts or too many credit loading processes, the meter
blocks loading of credit until the next day.
The logs of the credits loaded into the meter or called back can be read with
U.1.75*1,...,10 OBIS code.
LSM meters can optionally support multiple credits. Multiple credit fe- ature is
mainly used when different unit price and credit amount are required for
different source of electricity (i.e. generator).

1.10.30. Password Security Levels


LSM meters optionally support multiple password levels for writing
parameters to the meters. Each password level has different purposes as
below.
Level 1: Used for writing general basic parameters such as load profile
interval, demand period etc.
Level 0A: Used for subscriber relevant parameters such as relay con-
nect/disconnect, credit loading.
Level 0B: Used for removing meter lock states.
Level 0C: Used for writing date-time and related parameters.
Level 2: Master password. It has permission for writing every parameter
except credit loading and other credit related writing.

1.10.31. Pluggable Module Support


LSM20, LSM45 and LSM55 type of meters has plug and play module slot.
This feature gives an option to user for using alternative communication
module with same meter. RF, PLC, Ethernet, GSM or other communication
modules can be used and can be changed without replacing the meter.
Module can be plugged and detached easily. In addition, module is designed
to mount under the terminal cover so that it can be sealed by authorized
24
personnel. Modules can be changed without cutting off the power of meter.
Initilization and completion of registration is automatically done when the
module is mounted to meter and power is applied. Then, data concentrator
or head-end system can directly communicate with meter.
Communication modules have internal watchdog control mechanism to be
able to prevent hanging situations. External PLC, RF, GSM, Ethernet
modules may have additional RS485 communication port if requested.

1.10.31.1. Pluggable PLC Module


It is designed as an external PLC module. It can be easily plugged and
detached to meters which have an external module support. It has the same
communication properties with internal PLC module. Section 1.10.4 can be
taken as a reference.

1.10.31.2. Pluggable RF Module


It is designed as an external RF module. It can be easily plugged and
detached to meters which have an external module support. It has the same
communication properties with internal RF module. Section 1.10.5 can be
taken as a reference.

1.10.31.3. Pluggable GSM Module


It is designed as an external GSM module. It can be easily plugged and
detached to meters which have an external module support. It has the same
communication properties with internal GSM module. Section 1.10.6 can be
taken as a reference.

1.10.31.4. Pluggable Ethernet Module


It is designed as an external Ethernet module. It can be easily plugged and
detached to meters which have an external module support. All connection
steps are done automatically.

1.10.31.5. Pluggable Optical Fiber Port Module


It is designed as an external Optical Fiber Port module. It can be easily plugged and
detached to meters which have an external module support. All connection steps
are done automatically

1.10.32. Firmware Upgrade


LSM meters can optionally support firmware upgrade. Firmware can be
updated locally by optical port or can be updated by remotely with using PLC,
RF, GSM or any other communication interface.
25
2. OPERATING ELEMENTS
2.1.LCD
The meter displays energy data and other parameters on its 5-integer
(optionally 6 integer), 3-decimal digit LCD screen. It also displays symbols for
the notifications described above. Detailed information about LCD can be
found in the LCD Screen Information section.

2.2.Menu Button
The LCD menus can be browsed by pressing the menu button.

2.3.Active Power Consumption LED


Active led pulse output can be used for active power accuracy control. Each
light pulse indicates 1 Wh active power consumption if meter is designated as
1000imp/kWh. Each light pulse indicates 0.1Wh active power consumption if
meter is designated as 10.000imp/kWh.

2.4.Reactive Power Consumption LED (On Active-Reactive


Model)
Reactive led pulse output can be used for reactive power accuracy control.
Each light pulse indicates 1 VArh reactive power consumption if meter is
designated as 1000imp/kVArh. Each light pulse indicates 0.1VArh reactive
power consumption if meter is designated as 10.000imp/kVArh.
Total Reactive power can be indicated with one LED output or reactive
inductive and reactive capacitive power can be indicated with two leds
separately.

2.5.Optical Port
Optical port feature enables data transfer and programming in compliance with
EN 61107 communication protocol.
A receiver and a transmitter diode is used for optical communication.
Communication interface provides all index info, index and demand data from
past months, and enables officials to make authorized changes.
Optical port uses totally independent port for communication. Other port
communication doesn’t affect optical port interface and communication can be
realized at the same time without having any disruption or delay.

26
2.6.Sealing Spots
Embedded spots are found on the meter case to prevent intervention to the
meter.

3. SECURITY NOTICES
The meters should be mounted/dismounted by authorized personnel. The
energy should be cut off while mounting/dismounting the meters.
After the mounting the meters, in case of intervention by any individual or
organization apart from authorized personnel, the non-volatile memory will
record this intervention.

4. LCD SCREEN INFORMATION


Generally, LCD of the three phase meters indicates 6 integers and 3 decimals
and LCD of the monophase meters indicates 5 integers and 3 decimals.
Integer and decimal values can optionally be modified with designated obis
code (Detailed in clause 1.10.20). In addition, monophase meters may have 6
integers and 3 decimals on LCD if requested.

Option 1

Option 2

Option 3

27
5. MENUS
5.1.Main Menu
When the device is connected to energy, the list indicating Total Import Active
Energy menu will appear in terms of kWh on the LCD screen. At 5 second
intervals T1, T2, T3, T4, Reactive Inductive, Reactive Capacitive, Demand,
Total Export, Export T1, Export T2, Export T3, Export T4, Export Reactive
Inductive, Export Reactive Capacitive, Export Demand, Date, Time and Serial
Number menus will appear on the screen respectively and scroll automatically.
TOTAL CONSUMPTION TARIFF T
The menu that shows the total amount of energy
consumed in the other defined tarif zones.

TARIFF T1
The menu is as records of the energy used at the
specified time interval.

TARIFF T2
The menu is as records of the energy used at the
specified time interval.

TARIFF T3
The menu is as records of the energy used at the
specified time interval.

TARIFF T4
Menu reserved for weekend and season tariff that
the distribution company will prepare and take into
action.

REACTIVE-INDUCTIVE SCREEN
Indicates the consumed reactive- inductive
energy.

REACTIVE-CAPACITIVE SCREEN
Indicates the consumed reactive-
capacitive energy.

DEMAND SCREEN
Indicates maximum positive active energy
demand value for determined time interval.

EXPORT T TOTAL TARIFF


The menu that shows total export energy amounts,
28
recorded from other defined tarif segments.

EXPORT T1 TARIFF
The menu is as records of the export
energy used at the specified time interval.

EXPORT T2 TARIFF
The menu is as records of the export
energy used at the specified time interval.

EXPORT T3 TARIFF
The menu is as records of the export
energy used at the specified time interval.

EXPORT T4 TARIFF
Menu reserved for weekend and season tariff
that the distribution company will prepare and
take into action.

EXPORT REACTIVE - INDUCTIVE SCREEN


Indicates the consumed export reactive inductive
energy

EXPORT REACTIVE - CAPACITIVE SCREEN


Indicates the consumed reactive- capacitive
energy.

DATE SCREEN
Indicates the date of the meter

TIME SCREEN
Indicates the time of the meter

SERIAL NO SCREEN
Indicates the serial number of the
meter.

29
5.2.Notification
TERMINAL COVER REMOVAL NOTIFICATION
The visual on this notice on the screen indicates that terminal cover previously
opened. In case of unauthorized execution of this process, warranty will be
invalid and penalty fees may be incurred.

MAIN COVER REMOVAL NOTIFICATION


It indicates that main cover is opened. In case of unauthorized execution of this
process, warranty will be void and penalty fees may be incurred.

LOW BATTERY NOTIFICATION


This notice appears on the screen when the battery level is lower than a certain
voltage level. When you see this sign, please inform authorized personnel
and/or organization.

REAL TIME CLOCK FAILURE NOTIFICATION


This sign means Real-time clock is disrupted for any reason. In
this case, the meters write the values at the “Tarif T1”.

MAGNETIC INTERVENTION NOTIFICATION


This sign means there is a magnetic intervention to the meter.

COMMUNICATION NOTIFICATION
If the meter is able to communicate the icon is displayed
on the screen.

WARNING NOTIFICATION

LATCHING RELAY NOTIFICATION


Energy connected,
Energy disconnected
the status of latching relay is shown as above.
STATUS NOTIFICATION

MONEY NOTIFICATION
For prepaid meters, this symbol is shown on the display if
credit is loaded.

30
RTC ERROR NOTICE
Appears and remains on the lcd
persistently after a real-time-clock
error occurs.

MAGNETIC INTERVENTION NOTICE


Shown on the screen If there is
magnetic intervention on meter.
Stays on the screen continuously.

NOTE: LCD screen display can be changed upon request.

5.3.Sub Menu
To display ”Sub Menu” on the screen, press and hold the menu button of the
meter for 4 seconds. In the sub-menu; Voltage, Current, Power Factor,
Frequency information and previous month information of T, T1,T2, T3, T4,
Reactive inductive, Reactive Capacitive, Demand will appear onthe screen
respectively and scroll automatically. To quit ”Sub Menu”, press and hold the
menu button of the meter for 4 seconds.

Instant voltage screen

Instant current screen

Instant power factor screen

Instant frequency screen

Total consumed active energy in previous


month menu (T blinks)

31
Total consumed energy T1 tarif in previous
month menu (T1blinks)

Total consumed energyT2 tarif inprevious


month menu (T2 blinks)

Total consumed energy T3 tarif in previous


month menu (T3 blinks)

Total consumed energy T4 tarif in previous


month menu (T4 blinks)

Total consumed energy Reactive-Inductive in


previous month menu

Total consumed energy Reactive-Capacitive


in previous month menu

Total demand in previous month menu (P


blinks)

Demand reset count

Demand reset date

Demand reset time

32
On the meters that have bidirectional communication (import-export) feature,
previous month energy data of expert energy is screened respectively on
submenu.

6.PHYSICAL DIMENSIONS OF THE METER

33
7.CONNECTIONS

8.GENERAL MECHANICAL SCHEME

34
9.TECHNICAL SPECIFICATIONS
TYPE LSM20
Service Type Single phase 2 wire meter
Direct connected
Nominal Voltage 240VAC
AC

Operating 70% Un....120% Un


Voltage

Nominal Current (max) AC 5(100)A


Starting Current mA 20mA

Test Output 1000 imp/kWh

Power Consumption in voltage circuit :- ≤ 1.5W


Power Consumption
Power Consumption in current circuit :- ≤ 0.5 VA
Nominal 50 Hz ± %2
Frequency Hz

Method of Directly connected to primary


Measurement active-reactive meter

Accuracy Class Class 1 for kWh & Class 2 for kVA/h

LCD Screen 6 integers, 3 decimals

Communication RS485 / RF / GSM


Protocol (optional)

P&P RS485 / RF /
Comm. Modules GSM/ETH.

Protection Class IP54 OUTDOOR


Insulation protection Class II
Relative Humidity %95
Sea level altitude Till 1000 m from sea level

Operating -40 °C...+85 °C


Temperature Range

T1 Tarif T1 (06:00-17:00)

T2 Tarif T2 (17:00-22:00)

T3 Tarif T3 (22:00-06:00)

Daylight Last Sunday of March from 02:00 to 03:00


Saving Time Last Sunday of October from 03:00 to 02:00

Battery Life Operating: 10 years, shelf: 5 years


(lithium type)
Weight 571 gr

35
LSM20
Single Phase Import-Export / Ac�ve Reac�ve Meter
Smart Meter structure appropriate for pluggable communica�on modules

Technical Specifica�ons Integrated Op�onal Features

Single phase 2 wire meter RS485 communica�on port


Ac�ve-Reac�ve / Import-Export RF-ID module op�on
Ac�ve Class:B/C Reac�ve Class: 2 DLMS-Cosem support
Direct connected An� magne�c (AML)
5(100)A current Detec�on and record of magne�c interven�ons
240VAC reference voltage Latching relay (100A)
1000imp/kWh - 1000imp/kVArh LCD backlight
-40°C...+85°C temp. range Export energy measurement
IP54 protec�on class
188 segments LCD screen
Op�cal port communica�on
15m/90days - 30m/180days - 60m/360days
Op�onal Pluggable Modules
Load Profile record periods
Meter life +15 years
PLC communica�on module
Enclosure material Poly carbonate + Glass
GSM communica�on module
fiber
RF communica�on module
Terminal Connection: Bottom Connected
Ethernet module
Neutral measurement
Load profile records up to 20 years

36