This document provides the technical specifications for a 1x185rm NYY 0.6/1.0 (1.2) kV cable. The cable has a stranded compacted copper conductor with PVC insulation and an FRLS PVC sheath. Key specifications include a conductor cross-sectional area of 185 mm2, operating temperature range of -15°C to 70°C, insulation resistance of 36.7 M.ohm.km, and ability to carry 460A in free air at 350C. The cable complies with IEC 60502-1 and IEC 60228 standards.
This document provides the technical specifications for a 1x185rm NYY 0.6/1.0 (1.2) kV cable. The cable has a stranded compacted copper conductor with PVC insulation and an FRLS PVC sheath. Key specifications include a conductor cross-sectional area of 185 mm2, operating temperature range of -15°C to 70°C, insulation resistance of 36.7 M.ohm.km, and ability to carry 460A in free air at 350C. The cable complies with IEC 60502-1 and IEC 60228 standards.
This document provides the technical specifications for a 1x185rm NYY 0.6/1.0 (1.2) kV cable. The cable has a stranded compacted copper conductor with PVC insulation and an FRLS PVC sheath. Key specifications include a conductor cross-sectional area of 185 mm2, operating temperature range of -15°C to 70°C, insulation resistance of 36.7 M.ohm.km, and ability to carry 460A in free air at 350C. The cable complies with IEC 60502-1 and IEC 60228 standards.
TECHNICAL SPECIFICATION OF 1x185rm NYY 0.6/1.0 (1.
2) kV Cable
TYPE & SIZE OF CABLE
NYY 1x185rm (mm2)
VOLTAGE GRADE, U0/U (Um)
0.6/1.0 (1.2) kV
RELEVANT STANDARDS
IEC 60502-1, IEC 60228
TECHNICAL SPECIFICATION
Cross-sectional area of conductor, nominal 185 mm2
Number of core 1 core Material Annealed copper Maximum conductor temperature in normal operation 700C Conductor Class of conductor Class 2 Shape of conductor Stranded Circular Compacted Minimum Number of wire (manufacturing) 30 (37) Minimum & maximum diameter of conductor 15.3-16.8 mm Material PVC Thickness, nominal 2.2 mm Insulation Thickness, minimum 1.88 mm Color of insulation Black Material PVC Color Black Sheath Thickness, nominal 2.2 mm Thickness, minimum 1.77 mm Overall diameter, approximate 26.4 ± 2 mm Electrical Characteristics Other Characteristics D.C resistance of conductor at 200C, 0.0991 ohm/km Minimum bending radius 12 x Overall diameter maximum Insulation resistance constant ki at 200C, 36.7 M.ohm.km Operating temperature -15℃ to 70℃ minimum A.C. Voltage test for 05 minutes (2.5 U0+2 3.5 kV Standard packing length/ Drum 1000 Meter Wooden Drum kV) Current carrying capacity- Signature a. in free air at 350C (Open) 460 A b. in ground at 300C (Direct buried) 390 A Date Conductor : Stranded Circular Com Insulation : PVC (Black) Conductor : Stranded Circular Compacted Sheath Copper : FRLS PVC (Black) Insulation : PVC (Black) Sheath : FRLS PVC (Black)