You are on page 1of 86

Job No. : Sheet No.

: Revision :

1 1-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

DESIGN OF FLOOR BEAM 1 (FB - 1) TRIBUTARY AREA

DESIGN UNIT : METRIC

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 200.00 ksm = 1.9614 KN 4.00 mx 2.25 m


x
m2

LL = 17.65 KN
LL = 7.85 KN/m

Lr = 1.00 KN x 4.00 mx 2.25 m


m2

Lr = 9.00 KN
Lr = 4.00 KN/m

DEAD LOAD:

Weight of Slab = 21.15 KN


Weight of Finish = 5.40 KN
Weight of Ceiling = 0.90 KN
Weight of Beam = 7.52 KN
TOTAL DL = 34.97 KN
TOTAL DL = 8.74 KN/m

Wu = 1.2 DL + 1.6 LL + 0.5 Lr


Wu = 25.04 KN

Mu = Wu L2 L = 4.00 Meters
;
8

Mu = 50.09 KN-m

Rn = Mu Ø = 0.90
;
Ø b d2 b = 250.00 mm
d = 360.00 mm
Rn = 1.7177 Mpa
Job No. : Sheet No. : Revision :

1 2-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

ρ = 0.85 fc' 2 Rn fc' = 20.68 Mpa


x 1- 1 ;
fy 0.85 fc' fy = 275.00 Mpa

ρ = 0.0066

ρmin = 1.4 / fy
ρmin = 0.0051

ρь = ß 0.85 fc' (600) ; ß = 0.85


fy (600 + fy)

ρь = 0.0373

300 mm
250
ρmax = 0.75 ρь
ρmax = 0.0279
3 - 16 mm Ø RSB Top Bars
since ► ρmin < ρ < ρmax
500 mm

0.0051 0.0066 0.0279


► Steel yields
400

2 - 12 mm Ø RSB Extra Cut Bars


then : ►►► As = ρ b d 3 - 16 mm Ø RSB Bottom Bars
As = ρ b d ; ρ = 0.0066
b = 250.00 mm Stirrups Spacing : 3@0.05, 3@0.10, 3@0.15,
d = 360.00 mm and rest @ Every 0.20 m On Center

As = 592.68 mm2 FB-1 MIDSPAN CROSS SECTION

Reinforcement:

Use ►►► 2 - 12 mm Ø RSB ; As = 226.19 mm2


3 - 16 mm Ø RSB ; As = 603.19 mm2

TOTAL As = 829.38 mm2 > 592.68 mm2

T= C
As fy = 0.85 fc' ab
a= As fy = 228,079.63 = 51.90 mm
0.85 fc' b 4,394.50

Mu = Ø As fy (d - a/2)
= 68.57 x 106 N-mm
Mu = 68.57 KN-m > 50.09 KN-m (SAFE) ♦■♦ DESIGN OK!
Job No. : Sheet No. : Revision :

1 3-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

Check for Shear :

Wu = 25.04 KN
L = 4.00 m
d = 360.00 mm

Vu = Wu L - Wu d (shear at distance "d" from support)


2

Vu = 50.09 - 9.02
Vu = 41.07 KN = 41072.09 Newton

Vc = 1
fc' xbd
6

Vc = 68212.9 Newton

Ø Vc = 57981.0 Newton

Ø Vc
= 28990.48 Newton = 28.99 KN
2

Vu > Ø Vc
2
41.07 > 28.99 ( It needs web reinforcement)

Vs = Vu
- Vc
Ø

Vs = -19892.79 Newton

Using 10 mm Ø RSB Stirrups :

S = Av fy d
Vs

Av = 2 Õ d2
= 157.08 mm 2
4
S = -781.7346 mm
Use Max. S = d = 180.00 mm
2
Note: Use Stirrups Spacing : 3@0.05, 3@0.10, 3@0.15,
and rest @ Every 0.20 m On Center for much Safer Design

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556 MR. & MRS. ROBERT A. MONOY
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN
Revision :

TRIBUTARY AREA
Revision :

3 - 16 mm Ø RSB Top Bars

2 - 12 mm Ø RSB Extra Cut Bars


3 - 16 mm Ø RSB Bottom Bars
Revision :

APPROVED BY :

MR. & MRS. ROBERT A. MONOY


PROJECT OWNER
ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN
Job No. : Sheet No. : Revision :

1 1-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

DESIGN OF FLOOR BEAM 2 (FB - 2) TRIBUTARY AREA

DESIGN UNIT : METRIC

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 200.00 ksm = 1.9614 KN 1.00 mx 0.85 m


x
m2

LL = 1.67 KN
LL = 1.96 KN/m

Lr = 1.00 KN x 1.00 mx 0.85 m


m2

Lr = 0.85 KN
Lr = 1.00 KN/m

DEAD LOAD:

Weight of Slab = 2.00 KN


Weight of Finish = 0.51 KN
Weight of Ceiling = 0.09 KN
Weight of Beam = 1.88 KN
TOTAL DL = 4.47 KN
TOTAL DL = 4.47 KN/m

Wu = 1.2 DL + 1.6 LL + 0.5 Lr


Wu = 9.01 KN

Mu = Wu L2 L = 1.00 Meters
;
8

Mu = 1.13 KN-m

Rn = Mu Ø = 0.90
;
Ø b d2 b = 200.00 mm
d = 260.00 mm
Rn = 0.0925 Mpa
Job No. : Sheet No. : Revision :

1 2-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

ρ = 0.85 fc' 2 Rn fc' = 20.68 Mpa


x 1- 1 ;
fy 0.85 fc' fy = 275.00 Mpa

ρ = 0.0003

ρmin = 1.4 / fy
ρmin = 0.0051

ρь = ß 0.85 fc' (600) ; ß = 0.85


fy (600 + fy)

ρь = 0.0373

250 mm
300
200
ρmax = 0.75 ρь
ρmax = 0.0279
3 - 12 mm Ø RSB Top Bars
since ► ρmin > ρ < ρmax
400 mm

0.0051 0.0003 0.0279


► Steel yields
500
300

then : ►►► As = ρ b d 3 - 12 mm Ø RSB Bottom Bars


As = ρ b d ; ρ = 0.0051
b = 200.00 mm Stirrups Spacing : 3@0.05, 3@0.10, 3@0.15,
d = 260.00 mm and rest @ Every 0.20 m On Center

As = 264.73 mm2 FB-2 MIDSPAN CROSS SECTION

Reinforcement:

Use ►►► 3 - 12 mm Ø RSB ; As = 339.29 mm2

TOTAL As = 339.29 mm2 > 264.73 mm2

T= C
As fy = 0.85 fc' ab
a= As fy = 93,305.30 = 26.54 mm
0.85 fc' b 3,515.60

Mu = Ø As fy (d - a/2)
= 20.72 x 106 N-mm
Mu = 20.72 KN-m > 1.13 KN-m (SAFE) ♦■♦ DESIGN OK!
Job No. : Sheet No. : Revision :

1 3-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

Check for Shear :

Wu = 9.01 KN
L = 1.00 m
d = 260.00 mm

Vu = Wu L - Wu d (shear at distance "d" from support)


2

Vu = 4.50 - 2.34
Vu = 2.16 KN = 2161.26 Newton

Vc = 1
fc' xbd
6

Vc = 39411.9 Newton

Ø Vc = 33500.1 Newton

Ø Vc
= 16750.06 Newton = 16.75 KN
2

Vu > Ø Vc
2
2.16 > 16.75 ( It needs web reinforcement)

Vs = Vu
- Vc
Ø

Vs = -36869.24 Newton

Using 10 mm Ø RSB Stirrups :

S = Av fy d
Vs

Av = 2 Õ d2
= 157.08 mm 2
4
S = -304.6223 mm
Use Max. S = d = 130.00 mm
2
Note: Use Stirrups Spacing : 3@0.05, 3@0.10, 3@0.15,
and rest @ Every 0.20 m On Center for much Safer Design

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556 MR. & MRS. ROBERT A. MONOY
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN
Revision :

TRIBUTARY AREA
Revision :

3 - 12 mm Ø RSB Top Bars

3 - 12 mm Ø RSB Bottom Bars


Revision :

APPROVED BY :

MR. & MRS. ROBERT A. MONOY


PROJECT OWNER
ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN
Job No. : Sheet No. : Revision :

1 1-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

DESIGN OF ROOF BEAM 1 (RB - 1) TRIBUTARY AREA

DESIGN UNIT : METRIC

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

ROOF LIVE LOAD:

Lr = 1.00 KN x 4.00 mx 3.00 m


m2

Lr = 12.00 KN
Lr = 4.00 KN/m

DEAD LOAD:

Weight of Roof = 20.40 KN


Weight of Finish = 7.20 KN
Weight of Ceiling = 1.20 KN
Weight of Beam = 5.64 KN
TOTAL DL = 34.44 KN
TOTAL DL = 8.61 KN/m

Wu = 1.2 DL + 1.6 LL + 0.5 Lr


Wu = 12.33 KN

Mu = Wu L2 L = 4.00 Meters
;
8

Mu = 24.66 KN-m

Rn = Mu Ø = 0.90
;
Ø b d2 b = 200.00 mm
d = 260.00 mm

Rn = 2.0270 Mpa
Job No. : Sheet No. : Revision :

1 2-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

ρ = 0.85 fc' 2 Rn fc' = 20.68 Mpa


x 1- 1 ;
fy 0.85 fc' fy = 275.00 Mpa

ρ = 0.0079

ρmin = 1.4 / fy
ρmin = 0.0051

ρь = ß 0.85 fc' (600) ; ß = 0.85


fy (600 + fy)

ρь = 0.0373

250 mm
300
200
ρmax = 0.75 ρь
ρmax = 0.0279
3 - 12 mm Ø RSB Top Bars
since ► ρmin < ρ < ρmax
400 mm

0.0051 0.0079 0.0279


► Steel yields
500
300

2 - 12 mm Ø RSB Bottom Bars


then : ►►► As = ρ b d 3 - 12 mm Ø RSB Bottom Bars
As = ρ b d ; ρ = 0.0079
b = 200.00 mm Stirrups Spacing : 3@0.05, 3@0.10, 3@0.15,
d = 260.00 mm and rest @ Every 0.20 m On Center

As = 408.36 mm2 RB-1 MIDSPAN CROSS SECTION

Reinforcement:

Use ►►► 3 - 12 mm Ø RSB ; As = 339.29 mm2


2 - 12 mm Ø RSB ; As = 226.19 mm2

TOTAL As = 565.49 mm2 > 408.36 mm2

T= C
As fy = 0.85 fc' ab
a= As fy = 155,508.84 = 44.23 mm
0.85 fc' b 3,515.60

Mu = Ø As fy (d - a/2)
= 33.29 x 106 N-mm
Mu = 33.29 KN-m > 24.66 KN-m (SAFE) ♦■♦ DESIGN OK!
Job No. : Sheet No. : Revision :

1 3-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

Check for Shear :

Wu = 12.33 KN
L = 4.00 m
d = 260.00 mm

Vu = Wu L - Wu d (shear at distance "d" from support)


2

Vu = 24.66 - 3.21
Vu = 21.46 KN = 21457.68 Newton

Vc = 1
fc' xbd
6

Vc = 39411.9 Newton

Ø Vc = 33500.1 Newton

Ø Vc
= 16750.06 Newton = 16.75 KN
2

Vu > Ø Vc
2
21.46 > 16.75 ( It needs web reinforcement)

Vs = Vu
- Vc
Ø

Vs = -14167.57 Newton

Using 10 mm Ø RSB Stirrups :

S = Av fy d
Vs

Av = 2 Õ d2
= 157.08 mm 2
4
S = -792.7396 mm
Use Max. S = d = 130.00 mm
2
Note: Use Stirrups Spacing : 3@0.05, 3@0.10, 3@0.15,
and rest @ Every 0.20 m On Center for much Safer Design

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556 MR. & MRS. ROBERT A. MONOY
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN
Revision :

TRIBUTARY AREA
Revision :

3 - 12 mm Ø RSB Top Bars

2 - 12 mm Ø RSB Bottom Bars


3 - 12 mm Ø RSB Bottom Bars
Revision :

APPROVED BY :

MR. & MRS. ROBERT A. MONOY


PROJECT OWNER
ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN
Job No. : Sheet No. : Revision :

1 1-2
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

DESIGN OF COLUMN 1 (C-1)

DESIGN UNIT : METRIC TRIBUTARY AREA

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Top & Bottom Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 4.80 KN x 4.00 mx 3.00 m


m2

LL = 57.60 KN

Lr = 1.00 KN x 4.00 mx 3.00 m


m2

Lr = 12.00 KN

DEAD LOAD:

Weight of Roof = 20.40 KN


Weight of Slab = 56.40 KN
Weight of Finish = 14.40 KN
Weight of Ceiling = 2.40 KN
Weight of Beam = 45.12 KN
TOTAL DL = 138.72 KN

Pu = 1.2 DL + 1.6 LL + 0.5 Lr


Pu = 264.62 KN

Pu = Ø Pn ; Ø = 0.70 (For Tied Column)


Pn = 0.80 Po (For Tied Column)

■▪▪■ Assume Column Section : 250 mm x 400 mm with 8 -16 Ø mm RSB

Ø Pn = Capacity of Column
Ø Pn = 0.70 * ( 0.80 Po )
= 0.70*(0.80 * (0.85 fc' (Ag - Ast ) + Ast fy)))
Ø Pn = 1216.24 KN

since ► Ø Pn > Pu
1216.24 KN > 264.62 KN ♦■♦ DESIGN OK!

Job No. : Sheet No. : Revision :

1 2-2
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

Tie Reinforcement

■ minimum size
► 10 mm Ø for bar diameter ≤ 32 mm Ø
► 12 mm Ø for larger bars and bundled bars

■▪▪■ Since main vertical bar diameter is 16 mm Ø

Use ►►► 10 mm Ø for tie reinforcement

Spacing of Ties

► S ≤ 16 db ; db = main vertical bar diameter


► S ≤ 48 ds ; ds = diameter of tie reinforcement
► S ≤ least dimension

■▪▪■ Using 10 mm Ø tie reinforcement

► 16 db = 16(16) = 256 mm
► 48 ds = 48(10) = 480 mm
► least column dimension = 200 mm

Use ►►► 10 mm Ø tie reinforcement space @ every 200 mm O.C.

250 mm

2 - 16 mm Ø Vertical Bars
2 - 16 mm Ø Vertical Bars
400 mm

2 - 16 mm Ø Vertical Bars
2 - 16 mm Ø Vertical Bars

Note: Use Lateral Ties Spacing: 2 - 3@0.05, 3@0.10,


3@0.15,and rest @ Every 0.20 m On Center
for much safer design

COLUMN 1 (C-1) CROSS SECTION

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556 MR. & MRS. ROBERT A. MONOY
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN

BAR SIZE AREA PIECES SAY TOTAL AREA


10 78.54 #REF! #REF! PIECES #REF! mm2
12 113.10 #REF! 4 PIECES 452.39 mm2
16 201.06 #REF! 8 PIECES 1608.50 mm2
20 314.16 #REF! 4 PIECES 1256.64 mm2
22 380.13 #REF! 8 PIECES 3041.06 mm2
25 490.87 #REF! 8 PIECES 3926.99 mm2
28 615.75 #REF! #REF! PIECES #REF! mm2
32 804.25 #REF! #REF! PIECES #REF! mm2
36 1017.88 #REF! #REF! PIECES #REF! mm2
40 1256.64 #REF! #REF! PIECES #REF! mm2
50 1963.50 #REF! #REF! PIECES #REF! mm2
Revision :

TRIBUTARY AREA
Revision :

APPROVED BY :
MR. & MRS. ROBERT A. MONOY
PROJECT OWNER
ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN

1608.50
Job No. : Sheet No. : Revision :

1 1-2
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

DESIGN OF COLUMN 3 (C-3)

DESIGN UNIT : METRIC TRIBUTARY AREA

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Top & Bottom Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 4.80 KN x 4.00 mx 2.00 m


m2

LL = 38.40 KN

Lr = 1.00 KN x 4.00 mx 2.00 m


m2

Lr = 8.00 KN

DEAD LOAD:

Weight of Roof = 13.60 KN


Weight of Finish = 4.80 KN
Weight of Ceiling = 0.80 KN
Weight of Beam = 15.04 KN
TOTAL DL = 34.24 KN

Pu = 1.2 DL + 1.6 LL + 0.5 Lr


Pu = 106.53 KN

Pu = Ø Pn ; Ø = 0.70 (For Tied Column)


Pn = 0.80 Po (For Tied Column)

■▪▪■ Assume Column Section : 250 mm x 300 mm with 6 - 12 Ø mm RSB

Ø Pn = Capacity of Column
Ø Pn = 0.70 * ( 0.80 Po )
= 0.70*(0.80 * (0.85 fc' (Ag - Ast ) + Ast fy)))
Ø Pn = 836.10 KN

since ► Ø Pn > Pu
836.10 KN > 106.53 KN ♦■♦ DESIGN OK!

Job No. : Sheet No. : Revision :

1 2-2
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

Tie Reinforcement

■ minimum size
► 10 mm Ø for bar diameter ≤ 32 mm Ø
► 12 mm Ø for larger bars and bundled bars

■▪▪■ Since main vertical bar diameter is 12 mm Ø

Use ►►► 10 mm Ø for tie reinforcement

Spacing of Ties

► S ≤ 16 db ; db = main vertical bar diameter


► S ≤ 48 ds ; ds = diameter of tie reinforcement
► S ≤ least dimension

■▪▪■ Using 10 mm Ø tie reinforcement

► 16 db = 16(12) = 192 mm
► 48 ds = 48(10) = 480 mm
► least column dimension = 250 mm

Use ►►► 10 mm Ø tie reinforcement space @ every 192 mm O.C.

250 mm

6 - 12 mm Ø Vertical Bars
3000 mm

Note: Use Lateral Ties Spacing: 3@0.05, 3@0.10,


3@0.15,and rest @ Every 0.20 m On Center
for much safer design

COLUMN 3 (C-3) CROSS SECTION

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556 MR. & MRS. ROBERT A. MONOY
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN

BAR SIZE AREA PIECES SAY TOTAL AREA


10 78.54 #REF! #REF! PIECES #REF! mm2
12 113.10 #REF! 6 PIECES 678.58 mm2
16 201.06 #REF! 0 PIECES 0.00 mm2
20 314.16 #REF! 4 PIECES 1256.64 mm2
22 380.13 #REF! 8 PIECES 3041.06 mm2
25 490.87 #REF! 8 PIECES 3926.99 mm2
28 615.75 #REF! #REF! PIECES #REF! mm2
32 804.25 #REF! #REF! PIECES #REF! mm2
36 1017.88 #REF! #REF! PIECES #REF! mm2
40 1256.64 #REF! #REF! PIECES #REF! mm2
50 1963.50 #REF! #REF! PIECES #REF! mm2
Revision :

TRIBUTARY AREA
Revision :

Note: Use Lateral Ties Spacing: 3@0.05, 3@0.10,

APPROVED BY :
MR. & MRS. ROBERT A. MONOY
PROJECT OWNER
ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN
Job No. : Sheet No. : Revision :

1 1-2
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

DESIGN OF COLUMN 3 (C-3)

DESIGN UNIT : METRIC TRIBUTARY AREA

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
C3F3
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Top & Bottom Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 4.80 KN x 2.50 mx 2.00 m


m2

LL = 24.00 KN

Lr = 1.00 KN x 2.50 mx 2.00 m


m2

Lr = 5.00 KN

DEAD LOAD:

Weight of Roof = 8.50 KN


Weight of Finish = 3.00 KN
Weight of Ceiling = 0.50 KN
Weight of Beam = 15.04 KN
TOTAL DL = 27.04 KN

Pu = 1.2 DL + 1.6 LL + 0.5 Lr


Pu = 73.35 KN

Pu = Ø Pn ; Ø = 0.70 (For Tied Column)


Pn = 0.80 Po (For Tied Column)

■▪▪■ Assume Column Section : 150 mm x 250 mm with 6 - 12 Ø mm RSB

Ø Pn = Capacity of Column
Ø Pn = 0.70 * ( 0.80 Po )
= 0.70*(0.80 * (0.85 fc' (Ag - Ast ) + Ast fy)))
Ø Pn = 466.96 KN

since ► Ø Pn > Pu
466.96 KN > 73.35 KN ♦■♦ DESIGN OK!

Job No. : Sheet No. : Revision :

1 2-2
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

Tie Reinforcement

■ minimum size
► 10 mm Ø for bar diameter ≤ 32 mm Ø
► 12 mm Ø for larger bars and bundled bars

■▪▪■ Since main vertical bar diameter is 12 mm Ø

Use ►►► 10 mm Ø for tie reinforcement

Spacing of Ties

► S ≤ 16 db ; db = main vertical bar diameter


► S ≤ 48 ds ; ds = diameter of tie reinforcement
► S ≤ least dimension

■▪▪■ Using 10 mm Ø tie reinforcement

► 16 db = 16(12) = 192 mm
► 48 ds = 48(10) = 480 mm
► least column dimension = 250 mm

Use ►►► 10 mm Ø tie reinforcement space @ every 192 mm O.C.

150 mm

6 - 12 mm Ø Vertical Bars
250 mm

Note: Use Lateral Ties Spacing: 3@0.05, 3@0.10,


3@0.15,and rest @ Every 0.20 m On Center
for much safer design

COLUMN 3 (C-3) CROSS SECTION

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556 MR. & MRS. ROBERT A. MONOY
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN

BAR SIZE AREA PIECES SAY TOTAL AREA


10 78.54 #REF! #REF! PIECES #REF! mm2
12 113.10 #REF! 6 PIECES 678.58 mm2
16 201.06 #REF! 0 PIECES 0.00 mm2
20 314.16 #REF! 4 PIECES 1256.64 mm2
22 380.13 #REF! 8 PIECES 3041.06 mm2
25 490.87 #REF! 8 PIECES 3926.99 mm2
28 615.75 #REF! #REF! PIECES #REF! mm2
32 804.25 #REF! #REF! PIECES #REF! mm2
36 1017.88 #REF! #REF! PIECES #REF! mm2
40 1256.64 #REF! #REF! PIECES #REF! mm2
50 1963.50 #REF! #REF! PIECES #REF! mm2
Revision :

TRIBUTARY AREA
Revision :

Note: Use Lateral Ties Spacing: 3@0.05, 3@0.10,

APPROVED BY :
MR. & MRS. ROBERT A. MONOY
PROJECT OWNER
ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN
Job No. : Sheet No. : Revision :

1 1-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

DESIGN OF FOOTING FOUNDATION 1 (F - 1)

DESIGN UNIT : METRIC TRIBUTARY AREA

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 75.00 mm Minimum Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 4.80 KN x 4.00 mx 3.00 m


m2

LL = 57.60 KN

DEAD LOAD:

Weight of Roof = 20.40 KN


Weight of Slab = 56.40 KN
Weight of Finish = 14.40 KN
Weight of Ceiling = 2.40 KN
Weight of Beam = 45.12 KN
TOTAL DL = 138.72 KN

Assume : Weight of Footing to be 8% of Column Load

Weight of Footing = 15.71 KN


Total Load = 212.03 KN

Total Load
Required Area =
Allowable Soil Bearing Capacity

Required Area = 2.21 m2


L2 = 2.21 m2
L = 1.49 m

Say ►►► 1.50 x m 1.50 m Footing Dimension


Job No. : Sheet No. : Revision :

1 2-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

►►► Using Footing Size of 1.50 m x 1.50 m

Area = 2.25 m2

Pu = 1.2 DL + 1.6 LL + 0.5 Lr


Pu = 258.62 KN

Net Ultimate Upward Soil Pressure = Pu 258.62


= = 114.94 KPa
Area 2.25

Allowable Ultimate Soil Pressure = 96.00 x 258.62


= 117.10 KPa
212.03

since ► Allowable Ultimate Soil Pressure > Net Ultimate Upward Soil Pressure
117.10 KPa > 114.94 Kpa ♦■♦ DESIGN OK!

Compute "d" by Punching Shear

Assume : d = 0.275 m ; t = 0.35 m

1+ 2 fc' long side of column


Allowable Punching Shear, Vc = where ßc =
ßc 6 short side of column

0.275
1 fc'
Allowable Punching Shear, Vc =
3
►►► Use whichever is lesser

1+ 2 fc' 400.00
Vc = ; ßc = = 1.6
ßc 6 250.00

Vc = 1.71 MPa

Vc = 1 fc'
3

Vc = 1.52 MPa

►►► Vc = 1.52 MPa

Vu
Actual Punching Shear, Vn =
Ø bo d

Vu = 114.94 x ( 1.50 )2 - (( 0.25 + 0.275 )*( 0.40 + 0.275 ) = 217.89 MPa

bo = ( 0.25 + 0.275 )*( 2 ) + ( 0.40 + 0.275 )*( 2 ) = 2.40 m

Vn = Vu Ø = 0.85
;
Ø
Vn = 256.34 MPa
Job No. : Sheet No. : Revision :

1 3-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

Vc = 1 fc' ( 1.2 )* ( 0.35 )


6

Vc = 397.91 KN

d = Vn
Vc bo

d = 0.268 m < 0.275 m ♦■♦ DESIGN OK!

Reinforcement

As = ρbd ; b = 1500.00 mm
d = 275.00 mm
ρmin = 1.4 / fy
ρmin = 0.0051

As = 2100.00 mm2

Use ►►► 11 - 16 mm Ø Reinforcing Steel Bars Equaly Space Bothways


on 0.35 m Thick x 1.50 m x 1.50 m Footing Foundation

TOTAL As = 2,211.68 mm2 > 2,100.00 mm2 ♦■♦ DESIGN OK!

CONCRETE COL COLUMN AND


SEE COL DETAILS FOOTING

FIN GD LINE

FILL FILL
VARIES

NAT GD LINE
1.50 MIN (VARIES)

.075 .30 .075


75mm THK COMPACTED BASE COURSE
(3/4 Ø - 1 1/2 Ø GRAVEL BED

STD 90°
HOOK
0.30M

75 CLEAR
.075

GRAVEL BED

FOOTING REINF SEE SCH


SEE SCHEDULE COMPACTED SUBGRADE
OR NATURAL GROUND

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556 MR. & MRS. ROBERT A. MONOY
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN

BAR SIZE AREA PIECES SAY TOTAL AREA


10 78.54 #REF! #REF! PIECES #REF! mm2 1350 1050
12 113.10 #REF! 7 PIECES 791.68 mm2 9 7
16 201.06 #REF! 11 PIECES 2211.68 mm2 1256.637
20 314.16 #REF! 11 PIECES 3455.75 mm2 402.1239
22 380.13 #REF! #REF! PIECES #REF! mm2 1658.761
25 490.87 #REF! #REF! PIECES #REF! mm2
28 615.75 #REF! #REF! PIECES #REF! mm2
32 804.25 #REF! #REF! PIECES #REF! mm2
36 1017.88 #REF! #REF! PIECES #REF! mm2
40 1256.64 #REF! #REF! PIECES #REF! mm2 1850
50 1963.50 #REF! #REF! PIECES #REF! mm2 168.1818

2672.25 1350
6.75
402
Job No. : Sheet No. : Revision :

1 1-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

DESIGN OF FOOTING FOUNDATION 2 (F - 2)

DESIGN UNIT : METRIC TRIBUTARY AREA

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 75.00 mm Minimum Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 4.80 KN x 4.00 mx 2.00 m


m2

LL = 38.40 KN

DEAD LOAD:

Weight of Roof = 13.60 KN


Weight of Finish = 4.80 KN
Weight of Ceiling = 0.80 KN
Weight of Beam = 5.64 KN
TOTAL DL = 24.84 KN

Assume : Weight of Footing to be 8% of Column Load

Weight of Footing = 5.06 KN


Total Load = 68.30 KN

Total Load
Required Area =
Allowable Soil Bearing Capacity

Required Area = 0.71 m2


L2 = 0.71 m2
L = 0.84 m

Say ►►► 1.00 x m 1.00 m Footing Dimension


Job No. : Sheet No. : Revision :

1 2-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

►►► Using Footing Size of 1.00 m x 1.00 m

Area = 1.00 m2

Pu = 1.2 DL + 1.6 LL + 0.5 Lr


Pu = 91.25 KN

Net Ultimate Upward Soil Pressure = Pu 91.25


= = 91.25 KPa
Area 1.00

Allowable Ultimate Soil Pressure = 96.00 x 91.25


= 128.26 KPa
68.30

since ► Allowable Ultimate Soil Pressure > Net Ultimate Upward Soil Pressure
128.26 KPa > 91.25 Kpa ♦■♦ DESIGN OK!

Compute "d" by Punching Shear

Assume : d = 0.225 m ; t = 0.30 m

1+ 2 fc' long side of column


Allowable Punching Shear, Vc = where ßc =
ßc 6 short side of column

1 fc'
Allowable Punching Shear, Vc =
3
►►► Use whichever is lesser

1+ 2 fc' 300.00
Vc = ; ßc = = 1.2
ßc 6 250.00

Vc = 2.02 MPa

Vc = 1 fc'
3

Vc = 1.52 MPa

►►► Vc = 1.52 MPa

Vu
Actual Punching Shear, Vn =
Ø bo d

Vu = 91.25 x ( 1.00 )2 - (( 0.25 + 0.225 )*( 0.30 + 0.225 ) = 68.49 MPa

bo = ( 0.25 + 0.225 )*( 2 ) + ( 0.30 + 0.225 )*( 2 ) = 2.00 m

Vn = Vu Ø = 0.85
;
Ø
Vn = 80.58 MPa
Job No. : Sheet No. : Revision :

1 3-3
Engineer : Date :
Job Title : Two-Storey Apartment Type Building Checked : Date :
Location : Bo. Bahay Hari, Marilao, Bulacan Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Robert A. Monoy File : Dt/Tm :

Vc = 1 fc' ( 1.0 )* ( 0.30 )


6

Vc = 227.38 KN

d = Vn
Vc bo

d = 0.177 m < 0.225 m ♦■♦ DESIGN OK!

Reinforcement

As = ρbd ; b = 1000.00 mm
d = 225.00 mm
ρmin = 1.4 / fy
ρmin = 0.0051

As = 1145.45 mm2

Use ►►► 7 - 16 mm Ø Reinforcing Steel Bars Equaly Space Bothways


on 0.30 m Thick x 1.00 m x 1.00 m Footing Foundation

TOTAL As = 1,407.43 mm2 > 1,145.45 mm2 ♦■♦ DESIGN OK!

CONCRETE COL COLUMN AND


SEE COL DETAILS FOOTING

FIN GD LINE

FILL FILL
VARIES

NAT GD LINE
1.50 MIN (VARIES)

.075 .30 .075


75mm THK COMPACTED BASE COURSE
(3/4 Ø - 1 1/2 Ø GRAVEL BED

STD 90°
HOOK
0.30M

75 CLEAR
.075

GRAVEL BED

FOOTING REINF SEE SCH


SEE SCHEDULE COMPACTED SUBGRADE
OR NATURAL GROUND

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556 MR. & MRS. ROBERT A. MONOY
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BO. BAHAY HARI, MARILAO, BULACAN

BAR SIZE AREA PIECES SAY TOTAL AREA


10 78.54 #REF! #REF! PIECES #REF! mm2 1050
12 113.10 #REF! 6 PIECES 678.58 mm2 7
16 201.06 #REF! 7 PIECES 1407.43 mm2 1256.637
20 314.16 #REF! 11 PIECES 3455.75 mm2 402.1239
22 380.13 #REF! #REF! PIECES #REF! mm2 1658.761
25 490.87 #REF! #REF! PIECES #REF! mm2
28 615.75 #REF! #REF! PIECES #REF! mm2
32 804.25 #REF! #REF! PIECES #REF! mm2
36 1017.88 #REF! #REF! PIECES #REF! mm2
40 1256.64 #REF! #REF! PIECES #REF! mm2 1850
50 1963.50 #REF! #REF! PIECES #REF! mm2 168.1818

2672.25 1350
6.75
402
AP E X L IN E OF ROOF

Job No. : Sheet No. : Revision :

2 .7 0
6 .1 0
TOP OF BE AM (MAS TER BEDROOM)

SEE A2 3 /8 FOR DETAIL

3 .0 0
1 1-4
F
12

. 4 00 . 8. 4 6 0
FFL (MAS TER BEDROOM)

1 .2 6 FIN . GR AD E L INE

FFL ( KITCHEN)
N ATUR A L G RADE LINE Engineer : Date :
Job Title : A Proposed Split Level 4-Bedroom Residence Checked : Date :
Location : Brgy. Dizol, San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Bert Sevilla File : Dt/Tm :

DESIGN OF SUSPENDED TWO-WAY SLAB (S-2) TRIBUTARY AREA

DESIGN UNIT : METRIC C C'1

6.00
F

3.00 3.00

DESIGN DATA :

8
C1F1 B-1 C1F1 B-1 C1F1

TWO-WAY TWO-WAY

3.00
SLAB SLAB

B-1

-1
-1

-1
B

B
S-2 S-2
C3 F2

4.50
B-1 B-1

5'a
C1F1

fc' = 20.68 MPa (3,000 Psi)


TRELLIS
up up ABOVE

1.50
5
C1F1 B-1 C1F1

fy = 275.00 MPa Grade 40 Reinforcing Bar LOWER

qs = 96.00 KPa Soil Bearing Capacity


Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

Minimum Thickness = perimeter of panel


180

Minimum Thickness = 66.67 mm say 100.00 mm

DEAD LOAD:
Try 100 mm Slab
Dead Load = 2.35 KPa

LIVE LOAD:

Live Load = 4.80 KN/m2

W = 1.4 DL + 1.7 LL
W = 3.30 + 8.16
W = 11.46 KN

Considering 1 meter strip


W = 11.46 KN/m

m= Ls = 3.00 = 1.0
Lb 3.00

Negative Moments From Table (Negative Moments at Continuous Edge), Case 4

Negative Cs = 0.050
Negative Cb = 0.050

Ms = Cs wLs2
Ms = 0.050 (11.46)(32)
Ms = 5.16 KN-m

Mb = Cb wLb2
Mb = 0.050 (11.46)(32)
Mb = 5.16 KN-m
AP E X L IN E OF ROOF

Job No. : Sheet No. : Revision :

2 .7 0
6 .1 0
TOP OF BE AM (MAS TER BEDROOM)

S EE A2 3/8 FOR DETAIL

. 4 00 . 8. 4 6 0 3 . 0 0
F
12
1 2-4
FFL (MAS T ER BEDROOM)

1 .2 6
Engineer : Date :
FIN . GR AD E LINE
FFL (K ITCHEN)
NATUR AL G RADE LINE

Job Title : A Proposed Split Level 4-Bedroom Residence Checked : Date :


Location : Brgy. Dizol, San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Bert Sevilla File : Dt/Tm :

Along Short Direction: Along Long Direction:


+ WDL = 3.30 + WDL = 3.30
+ MsDL = 0.027 (3.30) (3)2 + MbDL = 0.027 (3.30) (3)2
+ MsDL = 0.80 KN-m + MbDL = 0.80 KN-m

+ WLL = 8.16 + WLL = 8.16


+ MsLL = 0.032 (8.16) (3) 2 + MbLL = 0.032 (8.16) (3)2
+ MsLL = 2.35 KN-m + MbLL = 2.35 KN-m

+ MTS = 0.80 + 2.35 + MbT = 0.80 + 2.35


+ MTS = 3.15 KN-m + MbT = 3.15 KN-m

Negative Moments at Discontinuous Edges Equal 1/3 of Positive Moment

- MS = (1/3) * (3.15) - Mb = (1/3) * (3.15)


- MS = 1.05 KN-m - Mb = 1.05 KN-m

Along Short Direction:


1. Midspan:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 3.15 KN-m

3150000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.03
w - 0.59 w2 = 0.03
0.59 w -w + 0.03 = 0
2

w2 -1.69 w + 0.051 = 0

By Quadratic Equation:
w = 0.0307

ρ = w fc' = 0.0023
fy

As = ρbd
As = 0.0023 (1000) (75)
As = 173.34 mm 2

Use 10 mm Bar Diameter

1000 Õ d2 173.34
S 4 =

S= 453.09 mm say 400 mm


Job No. : Sheet No. : Revision :
A P E X L IN E OF R OOF

2 .7 0
6 .1 0
T OP OF BE AM (M AS T E R B E DROOM )

. 4 0 0 . 84 60 3 . 0 0
S EE A 2 3 /8 F OR DE T AIL

F
12

F FL (M AS TER BEDR OOM)

1 .2 6
1 3-4
F IN. GR AD E L INE
F F L ( K ITC HE N)
NA T UR A L G R A DE LINE

Engineer : Date :
Job Title : A Proposed Split Level 4-Bedroom Residence Checked : Date :
Location : Brgy. Dizol, San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Bert Sevilla File : Dt/Tm :

2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 5.16 KN-m

5160000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.05
w - 0.59 w2 = 0.05
0.59 w2 -w + 0.05 = 0
w2 -1.69 w + 0.0835 = 0
w = 0.0510

ρ = w fc' = 0.0038
fy

As = ρbd
As = 0.0038 (1000) (75)
As = 287.46 mm 2

Use 12 mm Bar Diameter

1000 Õ d2 287.46
S 4 =

S= 393.44 mm say 350.00 mm On Center

3. Discontinuous Edge:

Use 3 times the spacing of midspan (moment is only 1/3 of midspan)


S = 3(500) = 1200 mm > 500 mm (ACI Code)
Bent up two of every three bars from the bottom steel

Along Long Direction:


1. Midspan d = 75 - 6 = 69.00 mm
Mu = Ø fc' bd w (1-0.59w)
2

Mu = 3.15 KN-m

3150000 = 0.90 (20.68) (1000) (69)2 w (1-0.59w)


w (1 - 0.59 w) = 0.04
w - 0.59 w2 = 0.04
0.59 w2 -w + 0.23 = 0
w2 -1.69 w + 0.3954 = 0
w = 0.0364

ρ = w fc' = 0.0027
fy
As = ρbd
As = 0.0211 (1000) (69)
2
As = 189.07 mm 2

Job No. : Sheet No. : Revision :


A P E X L IN E OF R OOF

2 .7 0
6 .1 0
T OP OF BE AM (M AS T E R B E DROOM )

. 4 0 0 . 84 60 3 . 0 0
S EE A 2 3 /8 F OR DE T AIL

F
12

F FL (M AS TER BEDR OOM)

1 .2 6
1 4-4
F IN. GR AD E L INE
F F L ( K ITC HE N)
NA T UR A L G R A DE LINE

Engineer : Date :
Job Title : A Proposed Split Level 4-Bedroom Residence Checked : Date :
Location : Brgy. Dizol, San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Bert Sevilla File : Dt/Tm :

Use 10 mm Bar Diameter

1000 Õ d2 189.07
=
S 4

S= 415.41 mm say 400.00 mm On Center

2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 5.16 KN-m

5160000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.05
w - 0.59 w = 2
0.05
0.59 w2 -w + 0.05 = 0
w2 -1.72 w + 0.0835 = 0
w= 0.0510

ρ = w fc' = 0.0038
fy

As = ρbd
As = 0.0038 (1000) (75)
As = 287.46 mm 2

Use 12 mm Bar Diameter

1000 Õ d2 287.46
=
S 4

S= 393.44 mm say 350.00 mm On Center

3. Discontinuous Edge:

Use 3 times the spacing of midspan (moment is only 1/3 of midspan)


S = 3(100) = 1200.00 mm > 500 mm (ACI Code)
Bent up two of every three bars from the bottom steel

Note : For better and safer design of two-way slab, adopt the design on the plan.

PREPARED BY : PRC REG. NO. : 0093332 APPROVED BY :


DATE OF REG. : 05-30-2002
VALIDITY : 09-27-2009
PTR NO. : 8406619 MR. & MRS. BERT SEVILLA
ANDY G. GAGELONIA ISSUED ON : 02-18-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BRGY. DIZOL, SAN JOSE CITY, N.E.
Revision :

TRIBUTARY AREA

C C'1 F

6.00
3.00 3.00

C1F1 B-1 C1F1 B-1 C1F1

TWO-WAY TWO-WAY
3.00

B-1 SLAB SLAB

-1
-1

-1
B

B
S-2 S-2
C3 F2
4.50

B-1 B-1
5'a

C1F1
TRELLIS
up up ABOVE
1.50
5

C1F1 B-1 C1F1

LOWER
Revision :
Revision :
Revision :

APPROVED BY :
MR. & MRS. BERT SEVILLA
PROJECT OWNER
ADDRESS: BRGY. DIZOL, SAN JOSE CITY, N.E.
Job No. : Sheet No. : Revision :

2 . 0 0. 3 2
MAI N APEX L I NE

3 .2 0 2 .3 2
SECOND ARY APEX LI NE

1 . 1 13 . 6 1 2 . 0 5
F I N. CON C. R OOF L EDGE L I NE

2 .6 7
T OP OF ROO F BE AM L I NE
L OW ER APEX L I NE

8 .7 2
L OW ER T OP OF RO OF B EAM L I
N E

5 .9 5
FI
N . SEC OND F L OOR LI NE F I N. S EC OND F L OOR LI NE

4 .3 3
3 .2 0
1 1-4

0 .7 0
FI
N . G ROU ND FLOO R L I
N E F I N. GR OUND F L OO R L I
N E

0 .7 0
FI
N . G ARAGE / LA ND DEV' T L I NE FI N. GAR AGE / LAN D DEV'
T L I NE

F R ONT EL EVA TI ON
scale 1:1 0 0 m ts

Engineer : Date :
Job Title : Proposed Two-Storey Residential Building Checked : Date :
Location : Lot 32 Blk 10, Canterbury St., Hillborugh Vill., Alabang, Muntinlupa Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Alexis Agoncillo File : Dt/Tm :

DESIGN OF SUSPENDED TWO-WAY SLAB (S-1) TRIBUTARY AREA

DESIGN UNIT : METRIC


C C'1 F

6.00
DESIGN DATA : 3.00 3.00

fc' = 20.70 MPa (3,000 Psi)

8
C1F1
fy = 414.00 MPa Grade 40 Reinforcing Bar
B-1 C1F1 B-1 C1F1

TWO-WAY TWO-WAY

qs = 96.00 KPa Soil Bearing Capacity

3.00
SLAB SLAB

B-1

B-1
B-1

B-1
S-1 S-1
C3 F2

4.50
Wc = 23.50 MPa Weight of Concrete B-1 B-1

5'a
C1F1
TRELLIS
Cc = 40.00 mm Concrete Cover up up

1.50
ABOVE

5
C1F1 B-1 C1F1

LOWER
LOAD COMPUTATIONS :

Minimum Thickness = perimeter of panel


180

Minimum Thickness = 150.00 mm say 150.00 mm

DEAD LOAD:
Try 150 mm Slab
Dead Load = 3.532 KPa

LIVE LOAD:

Live Load = 6.56 KN/m2

W = 1.4 DL + 1.7 LL
W = 3.30 + 8.16
W = 16.10 KN

Considering 1 meter strip


W = 16.10 KN/m

m= Ls = 6.00 = 0.8
Lb 7.50

Negative Moments From Table (Negative Moments at Continuous Edge), Case 4

Negative Cs = 0.071
Negative Cb = 0.029

Ms = Cs wLs2
Ms = 0.071 (16.10)(62)
Ms = 41.14 KN-m

Mb = Cb wLb2
Mb = 0.029 (16.1)(32)
Mb = 26.26 KN-m
Job No. : Sheet No. : Revision :

2 . 0 0. 3 2
MAI N APEX L I NE

3 .2 0 2 .3 2
SECOND ARY APEX LI NE

1 . 1 13 . 6 1 2 . 0 5
F I N. CON C. R OOF L EDGE L I NE

2 .6 7
T OP OF ROO F BE AM L I NE
L OW ER APEX L I NE

8 .7 2
L OW ER T OP OF RO OF B EAM L I
N E

5 .9 5
FI
N . SEC OND F L OOR LI NE F I N. S EC OND F L OOR LI NE

4 .3 3
1 2- 4

3 .2 0
0 .7 0
FI
N . G ROU ND FLOO R L I
N E F I N. GR OUND F L OO R L I
N E

0 .7 0
FI
N . G ARAGE / LA ND DEV' T L I NE FI N. GAR AGE / LAN D DEV'
T L I NE

F R ONT EL EVA TI ON
sc ale 1: 100 mt s

Engineer : Date :
Job Title : Proposed Two-Storey Residential Building Checked : Date :
Location : Lot 32 Blk 10, Canterbury St., Hillborugh Vill., Alabang, Muntinlupa Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Alexis Agoncillo File : Dt/Tm :

Along Short Direction: Along Long Direction:


+ MsDL = 0.039 (4.94) (6)2 + WDL = 4.94
+ MsDL = 6.94 KN-m + MbDL = 0.016 (4.94) (7.5)2
+ MsLL = 0.048 (11.15) (6)2 + MbDL = 4.45 KN-m
+ MsLL = 19.27 KN-m
+ WLL = 11.15
+ MTS = 0.80 + 2.35 + MbLL = 0.020 (11.15) (7.5)2
+ MTS = 26.21 KN-m + MbLL = 12.55 KN-m

+ MbT = 4.45 + 12.55


+ MbT = 17.00 KN-m

Negative Moments at Discontinuous Edges Equal 1/3 of Positive Moment

- MS = (1/3) * (26.21) - Mb = (1/3) * (17.00)


- MS = 8.74 KN-m - Mb = 5.67 KN-m

Along Short Direction:


1. Midspan:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 26.21 KN-m

26210000 = 0.90 (20.68) (1000) (125)2 w (1-0.59w)


w (1 - 0.59 w) = 0.09
w - 0.59 w2 = 0.09
0.59 w2 -w + 0.09 = 0
w2 -1.69 w + 0.153 = 0

By Quadratic Equation:
w = 0.0960

ρ = w fc' = 0.0048
fy

As = ρbd
As = 0.0048 (1000) (125)
As = 599.90 mm 2

Use 12 mm Bar Diameter

1000 Õ d2 599.90
S 4 =

S= 188.53 mm say 180 mm On Center


Job No. : Sheet No. : Revision :

2 . 0 0. 3 2
MAI N APEX L I NE

3 .2 0 2 .3 2
SECOND ARY APEX LI NE

1 . 1 13. 6 12. 0 5
F I N. CON C. R OOF L EDGE L I NE

2 .6 7
T OP OF ROO F BE AM L I NE
L OW ER APEX L I NE

8 .7 2
L OW ER T OP OF RO OF B EAM L I
N E

5 .9 5
FI
N . SEC OND F L OOR LI NE F I N. S EC OND F L OOR LI NE

4 .3 3
3 .2 0
1 3- 4
0 .7 0
FI
N . G ROU ND FLOO R L I
N E F I N. GR OUND F L OO R L I
N E

0 .7 0
FI
N . G ARAGE / LA ND DEV' T L I NE FI N. GAR AGE / LAN D DEV'
T L I NE

F R ONT EL EVA TI ON
scale 1:1 0 0 m ts

Engineer : Date :
Job Title : Proposed Two-Storey Residential Building Checked : Date :
Location : Lot 32 Blk 10, Canterbury St., Hillborugh Vill., Alabang, Muntinlupa Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Alexis Agoncillo File : Dt/Tm :

2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 41.14 KN-m

12460000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.12
w - 0.59 w2 = 0.12 0.20339
0.59 w2 -w + 0.12 = 0
w2 -1.72 w + 0.2034 = 0
w = 0.1277

ρ = w fc' = 0.0064
fy

As = ρbd
As = 0.0096 (1000) (75)
As = 478.88 mm 2

Use 10 mm Bar Diameter

1000 Õ d2 478.88
S 4 =

S= 164.01 mm say 100.00 mm On Center

3. Discontinuous Edge:

Use 3 times the spacing of midspan (moment is only 1/3 of midspan)


S = 3(200) = 540 mm > 500 mm (ACI Code)
Bent up two of every three bars from the bottom steel

Along Long Direction:


1. Midspan d = 100 - 6 = 94.00 mm
Mu = Ø fc' bd w (1-0.59w)
2

Mu = 17.00 KN-m

4870000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.02
w - 0.59 w2 = 0.02
0.59 w2 -w + 0.10 = 0
w2 -1.72 w + 0.169 = 0
w= 0.105

ρ = w fc' = 0.0053
fy
As = ρbd
As = 0.0079 (1000) (94)
2
As = 493.50 mm 2

MAIN AP EX LINE

2 .0 0 0 .3 2
2 .3 2
SECONDARY APEX LINE

FIN. CONC. ROOF LEDGE LINE Job No. : Sheet No. : Revision :

1 .1 3 1 .6 2 1 .0 5
TOP OF ROOF BEA M LINE
LOWER APEX LINE

2 .6 7
3 .2 0
8 .7 2

LOWER TOP OF ROOF BEAM LINE

FIN. SECOND FLOOR LINE FIN. SECOND FLOOR L INE

1 4- 4

5 .9 5
4 .3 3
3 .2 0

Engineer : Date :
FIN. GROUND FLOOR LINE FIN. GROUND FLOOR LINE
0 .7 0

FIN. GARAGE / LAND DE V'T LINE FIN. GARAGE / LAND DEV'T L INE

0 .7 0
Job Title : Proposed Two-Storey Residential Building FRONT ELEVATION
scale 1:100 mts Checked : Date :
Location : Lot 32 Blk 10, Canterbury St., Hillborugh Vill., Alabang, Muntinlupa Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Alexis Agoncillo File : Dt/Tm :

Use 10 mm Bar Diameter

1000 Õ d2 493.50
=
S 4

S= 159.15 mm say 100.00 mm On Center

2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 26.26 KN-m

6090000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.06
w - 0.59 w =2
0.06
0.59 w2 -w + 0.06 = 0
w2 -1.72 w + 0.1017 = 0
w= 0.0613

ρ = w fc' = 0.0031
fy

As = ρbd
As = 0.0046 (1000) (75)
As = 229.88 mm 2

Use 10 mm Bar Diameter

1000 Õ d2 229.88
=
S 4

S= 341.66 mm say 200.00 mm On Center

3. Discontinuous Edge:

Use 3 times the spacing of midspan (moment is only 1/3 of midspan)


S = 3(100) = 300.00 mm On Center

Note : For better and safer design of two-way slab, adopt the design on the plan.

PREPARED BY : PRC REG. NO. : 0093332 APPROVED BY :


DATE OF REG. : 05-30-2002
VALIDITY : 09-27-2009
PTR NO. : 8406619 MR. & MRS. ALEXIS AGONCILLO
ANDY G. GAGELONIA ISSUED ON : 02-18-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: SAN JOSE CITY, NUEVA ECIJA
Revision :

TRIBUTARY AREA

C C'1 F

6.00
3.00 3.00
8

C1F1 B-1 C1F1 B-1 C1F1

TWO-WAY TWO-WAY
3.00

SLAB SLAB
B-1

B-1
B-1

B-1

S-1 S-1
C3 F2
4.50

B-1 B-1
5'a

C1F1
TRELLIS
up up
1.50

ABOVE
5

C1F1 B-1 C1F1

LOWER
Revision :
Revision :
Revision :

APPROVED BY :
MR. & MRS. ALEXIS AGONCILLO
PROJECT OWNER
ADDRESS: SAN JOSE CITY, NUEVA ECIJA