DESIGN OF FLOOR BEAM 1 (B - 1) TRIBUTARY AREA

DESIGN UNIT : METRIC

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 15.00 KN 5.00 mx 3.00 m


x
m2

LL = 225.00 KN
LL = 75.00 KN/m

Lr = 1.00 KN x 5.00 mx 3.00 m


m2

Lr = 15.00 KN
Lr = 5.00 KN/m

DEAD LOAD:

Weight of Slab = 35.25 KN


Weight of Finish = 9.00 KN
Weight of Ceiling = 1.50 KN
Weight of Beam = 17.63 KN
TOTAL DL = 63.38 KN
TOTAL DL = 12.68 KN/m

Wu = 1.2 DL + 1.6 LL + 0.5 Lr


Wu = 137.71 KN

Mu = Wu L2 L = 3.00 Meters
;
8

Mu = 154.92 KN-m

Rn = Mu Ø = 0.90
;
Ø b d2 b = 200.00 mm
d = 400.00 mm

Rn = 5.3793 Mpa
ρ = 0.85 fc' 2 Rn fc' = 20.68 Mpa
x 1- 1 ;
fy 0.85 fc' fy = 275.00 Mpa

ρ = 0.0241

ρmin = 1.4 / fy
ρmin = 0.0051

ρь = ß 0.85 fc' (600) ; ß = 0.85


fy (600 + fy)

ρь = 0.0373

250 mm
300
200
ρmax = 0.75 ρь
ρmax = 0.0279
3 - 16 mm Ø RSB Top Bars
since ► ρmin < ρ < ρmax

500 mm
0.0051 0.0241 0.0279
► Steel yields

400
2 - 16 mm Ø RSB Bottom Bars
then : ►►► As = ρ b d 3 - 16 mm Ø RSB Bottom Bars
As = ρ b d ; ρ = 0.0241
b = 200.00 mm Stirrups Spacing : 5@0.05, 10@0.10, 10@0.15,
d = 400.00 mm and rest @ Every 0.20 m On Center

As = 1,928.56 mm2 B-1 MIDSPAN CROSS SECTION

Reinforcement:

Use ►►► 8 - 16 mm Ø RSB ; As = 2,513.27 mm2

TOTAL As = 2,513.27 mm2 > 1,928.56 mm2

T= C
As fy = 0.85 fc' ab
a= As fy = 691,150.38 = 196.60 mm
0.85 fc' b 3,515.60

Mu = Ø As fy (d - a/2)
= 187.67 x 106 N-mm
Mu = 187.67 KN-m > 154.92 KN-m (SAFE) ♦■♦ DESIGN OK!

Check for Shear :

Wu = 137.71 KN
L = 3.00 m
d = 400.00 mm

Vu = Wu L - Wu d (shear at distance "d" from support)


2
Vu = 206.57 - 55.08
Vu = 151.48 KN = 151481.00 Newton

Vc = 1
fc' xbd
6

Vc = 60633.7 Newton

Ø Vc = 51538.6 Newton

Ø Vc
= 25769.32 Newton = 25.77 KN
2

Vu > Ø Vc
2
151.48 > 25.77 ( It needs web reinforcement)

Vs = Vu
- Vc
Ø

Vs = 117579.3 Newton

Using 10 mm Ø RSB Stirrups :

S = Av fy d
Vs

Av = 2 Õ d2
= 157.08 mm 2
4
S = 146.9542 mm
Use Max. S = d = 200.00 mm
2
Note: Use Stirrups Spacing : 5@0.05, 10@0.10, 10@0.15,
and rest @ Every 0.20 m On Center for much Safer Design

Prepared by :

FLOYD C. ANTOLIN
Civil Engineer

PRC No. : 107439


VALIDITY : 7/17/2012
PTR No. : 153781
ISSUED AT : SCM
ISSUED ON : 1/27/2011
TIN NO : 227-827-369
DESIGN OF ROOF BEAM 1 (RB - 1) TRIBUTARY AREA

DESIGN UNIT : METRIC

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

ROOF LIVE LOAD:

Lr = 1.00 KN x 3.00 mx 5.00 m


m2

Lr = 15.00 KN
Lr = 3.00 KN/m

DEAD LOAD:

Weight of Roof = 25.50 KN


Weight of Finish = 9.00 KN
Weight of Ceiling = 1.50 KN
Weight of Beam = 4.23 KN
TOTAL DL = 40.23 KN
TOTAL DL = 13.41 KN/m

Wu = 1.2 DL + 1.6 LL + 0.5 Lr


Wu = 17.59 KN

Mu = Wu L2 L = 5.00 Meters
;
8

Mu = 54.98 KN-m

Rn = Mu Ø = 0.90
;
Ø b d2 b = 200.00 mm
d = 300.00 mm

Rn = 3.3935 Mpa
ρ = 0.85 fc' 2 Rn fc' = 20.68 Mpa
x 1- 1 ;
fy 0.85 fc' fy = 275.00 Mpa

ρ = 0.0138

ρmin = 1.4 / fy
ρmin = 0.0051

ρь = ß 0.85 fc' (600) ; ß = 0.85


fy (600 + fy)

ρь = 0.0373

250 mm
300
200
ρmax = 0.75 ρь
ρmax = 0.0279
2 - 16 mm Ø RSB Top Bars
since ► ρmin < ρ < ρmax

400 mm
0.0051 0.0138 0.0279
► Steel yields 500
300
2 - 16 mm Ø RSB Bottom Bars
then : ►►► As = ρ b d 2 - 16 mm Ø RSB Bottom Bars
As = ρ b d ; ρ = 0.0138
b = 200.00 mm Stirrups Spacing : 5@0.05, 5@0.10, 5@0.15,
d = 300.00 mm and rest @ Every 0.20 m On Center

As = 830.28 mm2 RB-1 MIDSPAN CROSS SECTION

Reinforcement:

Use ►►► 6 - 16 mm Ø RSB ; As = 1,206.37 mm2

TOTAL As = 1,206.37 mm2 > 830.28 mm2

T= C
As fy = 0.85 fc' ab
a= As fy = 331,752.18 = 94.37 mm
0.85 fc' b 3,515.60

Mu = Ø As fy (d - a/2)
= 75.49 x 106 N-mm
Mu = 75.49 KN-m > 54.98 KN-m (SAFE) ♦■♦ DESIGN OK!

Check for Shear :

Wu = 17.59 KN
L = 5.00 m
d = 300.00 mm

Vu = Wu L - Wu d (shear at distance "d" from support)


2

Vu = 43.98 - 5.28
-
Vu = 38.70 KN = 38702.40 Newton
Vc = 1
fc' xbd
6

Vc = 45475.3 Newton

Ø Vc = 38654.0 Newton

Ø Vc
= 19326.99 Newton = 19.33 KN
2

Vu > Ø Vc
2
38.70 > 19.33 ( It needs web reinforcement)

Vs = Vu
- Vc
Ø

Vs = 56.96729 Newton

Using 10 mm Ø RSB Stirrups :

S = Av fy d
Vs

Av = 2 Õ d2
= 157.08 mm 2
4
S = 227482.6 mm
Use Max. S = d = 150.00 mm
2
Note: Use Stirrups Spacing : 5@0.05, 5@0.10, 5@0.15,
and rest @ Every 0.20 m On Center for much Safer Design

Prepared by :

FLOYD C. ANTOLIN
Civil Engineer

PRC No. : 107439


VALIDITY : 7/17/2012
PTR No. : 153781
ISSUED AT : SCM
ISSUED ON : 1/27/2011
TIN NO : 227-827-369
DESIGN OF CANTILEVER BEAM 1 (CB - 1)

DESIGN UNIT : METRIC

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

ROOF LIVE LOAD:

Lr = 1.00 KN x 3.00 mx 5.00 m


m2

Lr = 15.00 KN
Lr = 3.00 KN/m

DEAD LOAD:

Weight of Roof = 25.50 KN


Weight of Finish = 9.00 KN
Weight of Ceiling = 1.50 KN
Weight of Beam = 4.23 KN
TOTAL DL = 40.23 KN
TOTAL DL = 13.41 KN/m

Wu = 1.2 DL + 1.6 LL + 0.5 Lr


Wu = 17.59 KN

Mu = Wu L2 L = 5.00 Meters
;
8

Mu = 54.98 KN-m

Rn = Mu Ø = 0.90
;
Ø b d2 b = 200.00 mm
d = 400.00 mm

Rn = 1.9089 Mpa

ρ = 0.85 fc' 2 Rn fc' = 20.68 Mpa


x 1- 1 ; fy =
fy 0.85 fc' 275.00 Mpa

ρ = 0.0074
ρmin = 1.4 / fy
ρmin = 0.0051

ρь = ß 0.85 fc' (600) ; ß = 0.85


fy (600 + fy)

ρь = 0.0373

250 mm
300
200
ρmax = 0.75 ρь
ρmax = 0.0279
2 - 16 mm Ø RSB Top Bars
since ► ρmin < ρ < ρmax

300 mm
0.0051 0.0074 0.0279
► Steel yields

500
400
2 - 16 mm Ø RSB Bottom Bars
then : ►►► As = ρ b d 2 - 16 mm Ø RSB Bottom Bars
As = ρ b d ; ρ = 0.0074
b = 200.00 mm Stirrups Spacing : 5@0.05, 5@0.10, 5@0.15,
d = 400.00 mm and rest @ Every 0.20 m On Center

As = 589.25 mm2 CB-1 MIDSPAN CROSS SECTION

Reinforcement:

Use ►►► 6 - 16 mm Ø RSB ; As = 1,206.37 mm2

TOTAL As = 1,206.37 mm2 > 589.25 mm2

T= C
As fy = 0.85 fc' ab
a= As fy = 331,752.18 = 94.37 mm
0.85 fc' b 3,515.60

Mu = Ø As fy (d - a/2)
= 105.34 x 106 N-mm
Mu = 105.34 KN-m > 54.98 KN-m (SAFE) ♦■♦ DESIGN OK!

Check for Shear :

Wu = 17.59 KN
L = 5.00 m
d = 400.00 mm

Vu = Wu L - Wu d (shear at distance "d" from support)


2

Vu = 43.98 - 7.04
Vu = 36.94 KN = 36943.20 Newton

Vc = 1
fc' xbd
6
6
Vc = 60633.7 Newton

Ø Vc = 51538.6 Newton

Ø Vc
= 25769.32 Newton = 25.77 KN
2

Vu > Ø Vc
2
36.94 > 25.77 ( It needs web reinforcement)

Vs = Vu
- Vc
Ø

Vs = -17171.1 Newton

Using 10 mm Ø RSB Stirrups :

S = Av fy d
Vs

Av = 2 Õ d2
= 157.08 mm 2
4
S = -1006.27 mm
Use Max. S = d = 200.00 mm
2
Note: Use Stirrups Spacing : 5@0.05, 5@0.10, 5@0.15,
and rest @ Every 0.20 m On Center for much Safer Design

Prepared by :

FLOYD C. ANTOLIN
Civil Engineer

PRC No. : 107439


VALIDITY : 7/17/2012
PTR No. : 153781
ISSUED AT : SCM
ISSUED ON : 1/27/2011
TIN NO : 227-827-369
2 - 16 mm Ø RSB Top Bars

2 - 16 mm Ø RSB Bottom Bars


2 - 16 mm Ø RSB Bottom Bars
DESIGN OF COLUMN

DESIGN UNIT : METRIC TRIBUTARY AREA

DESIGN DATA :

fc' = 20.68 MPa (3,000 Psi)


fy = 275.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Top & Bottom Concrete Cover

LOAD COMPUTATIONS :

LIVE LOAD:

LL = 15.00 KN x 5.00 mx 3.00 m


m2

LL = 225.00 KN

Lr = 1.00 KN x 5.00 mx 3.00 m


m2

Lr = 15.00 KN

DEAD LOAD:

Weight of Roof = 25.50 KN


Weight of Slab = 35.25 KN
Weight of Finish = 9.00 KN
Weight of Ceiling = 1.50 KN
Weight of Beam = 19.74 KN
TOTAL DL = 90.99 KN

Pu = 1.2 DL + 1.6 LL + 0.5 Lr


Pu = 476.69 KN

Pu = Ø Pn ; Ø = 0.70 (For Tied Column)


Pn = 0.80 Po (For Tied Column)

■▪▪■ Assume Column Section : 200 mm x 400 mm with 8 -16 Ø mm RSB

Ø Pn = Capacity of Column
Ø Pn = 0.70 * ( 0.80 Po )
= 0.70*(0.80 * (0.85 fc' (Ag - Ast ) + Ast fy)))
Ø Pn = 1077.34 KN

since ► Ø Pn > Pu
1077.34 KN > 476.69 KN ♦■♦ DESIGN OK!
Tie Reinforcement

■ minimum size
► 10 mm Ø for bar diameter ≤ 32 mm Ø
► 12 mm Ø for larger bars and bundled bars

■▪▪■ Since main vertical bar diameter is 16 mm Ø

Use ►►► 10 mm Ø for tie reinforcement

Spacing of Ties

► S ≤ 16 db ; db = main vertical bar diameter


► S ≤ 48 ds ; ds = diameter of tie reinforcement
► S ≤ least dimension

■▪▪■ Using 10 mm Ø tie reinforcement

► 16 db = 16(16) = 256 mm
► 48 ds = 48(10) = 480 mm
► least column dimension = 350 mm

Use ►►► 10 mm Ø tie reinforcement space @ every 256 mm O.C.

200 mm
400 mm

8 - 16 mm Ø Vertical Bars

Note: Use 2 - Lateral Ties with Inner Ties Space @ Every 5@0.05,
10@0.10, 10@0.15,and rest @ Every 0.20 m On Center
for much safer design

CROSS SECTION

Prepared by :

FLOYD C. ANTOLIN
Civil Engineer

PRC No. : 107439


VALIDITY : 7/17/2012
PTR No. : 153781
ISSUED AT : SCM
ISSUED ON : 1/27/2011
TIN NO : 227-827-369
2 .0 0
0 .5 0
3 .2 0
3 .2 0
3 .5 0
0 .3 0 Job No. : Sheet No. : Revision :

FRONT ELEVATION
scale 1 :200 mts
Engineer : Date :
Job Title : Proposed Construction of Two-Storey Commercial Building Checked : Date :
Location : San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : File : Dt/Tm :

DESIGN OF FOOTING FOUNDATION 1 (F - 1)

10.00
DESIGN UNIT : METRIC TRIBUTARY AREA
HIGH DISPLAY

DESIGN DATA : AREA

5.28
fc' = 20.68 MPa (3,000 Psi)
fy = 275.00 MPa Grade 40 Reinforcing Bar INTERMEDIATE BEAM
(SAME AS B-2)
INTERMEDIATE BEAM
(SAME AS B-2)
INTERMEDIATE BEAM
(SAME AS B-2)
INTERMEDIATE BEAM
(SAME AS B-2)

B-1

B-1
B-1
qs = 96.00 KPa Soil Bearing Capacity

12.00
Wc = 23.50 MPa Weight of Concrete

6.00
COLUMN 1 (C-1)
Cc = 75.00 mm Minimum Concrete Cover B-2
COUNTER

B-3
LOAD COMPUTATIONS :
ENTRANCE

2.01
LIVE LOAD:

2.50
second floor line

0.50
LL = 15.00 KN x 5.00 mx 3.00 m 21.29

m2

LL = 225.00 KN

DEAD LOAD:

Weight of Roof = 25.50 KN


Weight of Slab = 35.25 KN
Weight of Finish = 9.00 KN
Weight of Ceiling = 1.50 KN
Weight of Beam = 11.28 KN
TOTAL DL = 82.53 KN

Assume : Weight of Footing to be 8% of Column Load

Weight of Footing = 24.60 KN


Total Load = 332.13 KN

Total Load
Required Area =
Allowable Soil Bearing Capacity

Required Area = 3.46 m2


L2 = 3.46 m2
L = 1.86 m

Say ►►► 1.20 x m 1.20 m Footing Dimension


►►► Using Footing Size of 1.20 m x 1.20 m

Area = 1.44 m2

Pu = 1.2 DL + 1.6 LL + 0.5 Lr


Pu = 459.04 KN

Net Ultimate Upward Soil Pressure = Pu 459.04


= = 318.78 KPa
Area 1.44

Allowable Ultimate Soil Pressure = 96.00 x 459.04


= 132.68 KPa
332.13

since ► Allowable Ultimate Soil Pressure > Net Ultimate Upward Soil Pressure
132.68 KPa > 318.78 Kpa ♦■♦ DESIGN OK!

Compute "d" by Punching Shear

Assume : d = 0.325 m ; t = 0.40 m

1+ 2 fc' long side of column


Allowable Punching Shear, Vc = where ßc =
ßc 6 short side of column

1 fc'
Allowable Punching Shear, Vc =
3
►►► Use whichever is lesser

1+ 2 fc' 400.00
Vc = ; ßc = = 1
ßc 6 400.00

Vc = 2.27 MPa

Vc = 1 fc'
3

Vc = 1.52 MPa

►►► Vc = 1.52 MPa

Vu
Actual Punching Shear, Vn =
Ø bo d

Vu = 318.78 x ( 2.50 )2 - (( 0.40 + 0.325 )*( 0.40 + 0.325 ) = 1824.79 MPa

bo = ( 0.40 + 0.325 )*( 2 ) + ( 0.40 + 0.325 )*( 2 ) = 2.90 m

Vn = Vu Ø = 0.85
;
Ø

Vn = 2146.81 MPa

Vc = 1 fc' ( 2.5 )* ( 0.40 )


6

Vc = 757.92 KN
d = Vn
Vc bo

d = 0.977 m < 0.325 m ♦■♦ DESIGN OK!

Reinforcement

As = ρbd ; b = 1200.00 mm
d = 325.00 mm
ρmin = 1.4 / fy
ρmin = 0.0051

As = 1,985.45 mm2

Use ►►► 15 - 25 mm Ø Reinforcing Steel Bars Equaly Space Bothways


on 0.40 m Thick x 2.50 m x 2.50 m Footing Foundation

TOTAL As = 7,363.11 mm2 > 1,985.45 mm2 ♦■♦ DESIGN OK!

CONCRETE COL COLUMN AND


SEE COL DETAILS FOOTING

FIN GD LINE

FILL FILL
VARIES

NAT GD LINE
1.50 MIN (VARIES)

.075 .30 .075


75mm THK COMPACTED BASE COURSE
(3/4 Ø - 1 1/2 Ø GRAVEL BED

STD 90°
HOOK
0.30M

75 CLEAR
.075

GRAVEL BED

FOOTING REINF SEE SCH


SEE SCHEDULE COMPACTED SUBGRADE
OR NATURAL GROUND

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: SAN JOSE CITY, NUEVA ECIJA
DESIGN OF FOOTING FOUNDATION 2 (F - 2)

10.00
DESIGN UNIT : METRIC TRIBUTARY AREA

15.00
AREA UNLOADING

DESIGN DATA : LOADING BAY

roll up door
STAFF
ENTRANCE

7.70
fc' = 20.68 MPa (3,000 Psi) INTERMEDIATE BEAM INTERMEDIATE BEAM INTERMEDIATE BEAM INTERMEDIATE BEAM INTERMEDIATE BEAM
(SAME AS B-2) (SAME AS B-2) (SAME AS B-2) (SAME AS B-2) (SAME AS B-2)

fy = 275.00 MPa Grade 40 Reinforcing Bar

B-1

B-1

B-1

B-1
qs = 96.00 KPa Soil Bearing Capacity

12.00
canopy line

Wc = 23.50 MPa Weight of Concrete


Cc = 75.00 mm Minimum Concrete Cover B-2

7.00
COUNTER 5.28

B-3
LOAD COMPUTATIONS : COLUMN 2 (C-2)

4.06
ENTRANCE F-2 UP

2.01

2.01
second floor line
LIVE LOAD:
21.29

LL = 7.20 KN x 5.28 mx 2.05 m


m2

LL = 77.93 KN

DEAD LOAD:

Weight of Roof = 18.40 KN


Weight of Finish = 6.49 KN
Weight of Ceiling = 1.08 KN
Weight of Beam = 6.74 KN
TOTAL DL = 32.72 KN

Assume : Weight of Footing to be 8% of Column Load

Weight of Footing = 8.85 KN


Total Load = 119.51 KN

Total Load
Required Area =
Allowable Soil Bearing Capacity

Required Area = 1.24 m2


L2 = 1.24 m2
L = 1.12 m

Say ►►► 1.50 x m 1.50 m Footing Dimension


►►► Using Footing Size of 1.50 m x 1.50 m

Area = 2.25 m2

Pu = 1.2 DL + 1.6 LL + 0.5 Lr


Pu = 163.96 KN

Net Ultimate Upward Soil Pressure = Pu 163.96


= = 72.87 KPa
Area 2.25

Allowable Ultimate Soil Pressure = 96.00 x 163.96


= 131.71 KPa
119.51

since ► Allowable Ultimate Soil Pressure > Net Ultimate Upward Soil Pressure
131.71 KPa > 72.87 Kpa ♦■♦ DESIGN OK!

Compute "d" by Punching Shear

Assume : d = 0.275 m ; t = 0.35 m

1+ 2 fc' long side of column


Allowable Punching Shear, Vc = where ßc =
ßc 6 short side of column

1 fc'
Allowable Punching Shear, Vc =
3
►►► Use whichever is lesser

1+ 2 fc' 500.00
Vc = ; ßc = = 1.667
ßc 6 300.00

Vc = 1.67 MPa

Vc = 1 fc'
3

Vc = 1.52 MPa

►►► Vc = 1.52 MPa

Vu
Actual Punching Shear, Vn =
Ø bo d

Vu = 72.87 x ( 1.50 )2 - (( 0.30 + 0.275 )*( 0.50 + 0.275 ) = 131.49 MPa

bo = ( 0.30 + 0.275 )*( 2 ) + ( 0.50 + 0.275 )*( 2 ) = 2.70 m

Vn = Vu Ø = 0.85
;
Ø

Vn = 154.69 MPa

Vc = 1 fc' ( 1.5 )* ( 0.35 )


6

Vc = 397.91 KN
d = Vn
Vc bo

d = 0.144 m < 0.275 m ♦■♦ DESIGN OK!

Reinforcement

As = ρbd ; b = 1500.00 mm
d = 275.00 mm
ρmin = 1.4 / fy
ρmin = 0.0051

As = 2100.00 mm2

Use ►►► 10 - 20 mm Ø Reinforcing Steel Bars Equaly Space Bothways


on 0.35 m Thick x 1.50 m x 1.50 m Footing Foundation

TOTAL As = 3,141.59 mm2 > 2,100.00 mm2 ♦■♦ DESIGN OK!

CONCRETE COL COLUMN AND


SEE COL DETAILS FOOTING

FIN GD LINE

FILL FILL
VARIES

NAT GD LINE
1.50 MIN (VARIES)

.075 .30 .075


75mm THK COMPACTED BASE COURSE
(3/4 Ø - 1 1/2 Ø GRAVEL BED

STD 90°
HOOK
0.30M

75 CLEAR
.075

GRAVEL BED

FOOTING REINF SEE SCH


SEE SCHEDULE COMPACTED SUBGRADE
OR NATURAL GROUND

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: SAN JOSE CITY, NUEVA ECIJA
2 .0 0
0 .5 0
3 .2 0
3 .2 0
3 .5 0
0 .3 0 Job No. : Sheet No. : Revision :

FRONT ELEVATION
scale 1: 200 mts
Engineer : Date :
Job Title : Proposed Construction of Two-Storey Commercial Building Checked : Date :
Location : San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : File : Dt/Tm :

DESIGN OF SUSPENDED TWO-WAY SLAB (S-1) TRIBUTARY AREA

DESIGN UNIT : METRIC

DESIGN DATA : INTERMEDIATE BEAM INTERMEDIATE BEAM


(SAME AS B-2)
5.28
INTERMEDIATE BEAM
(SAME AS B-2)
INTERMEDIATE BEAM
(SAME AS B-2)

B-1
B-1

B-1
SLAB 1 (S-1)

3.91
fc' = 20.68 MPa (3,000 Psi)
fy = 275.00 MPa Grade 40 Reinforcing Bar
B-2
COUNTER

B-3

B-3

B-3

B-3
qs = 96.00 KPa Soil Bearing Capacity COLUMN 2 (C-2)

Wc = 23.50 MPa Weight of Concrete


B-2
ENTRANCE

second floor line

Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

Minimum Thickness = perimeter of panel


180

Minimum Thickness = 102.11 mm say 125.00 mm

DEAD LOAD:
Try 100 mm Slab
Dead Load = 2.94 KPa

LIVE LOAD:

Live Load = 7.20 KN/m2

W = 1.4 DL + 1.7 LL
W = 4.12 + 12.24
W = 16.36 KN/m

Considering 1 meter strip


W = 16.36 KN/m

m= Ls = 3.91 = 0.7
Lb 5.28

Negative Moments From Table (Negative Moments at Continuous Edge), Case 2

Negative Cs = 0.074
Negative Cb = 0.017

Ms = Cs wLs2
Ms = 0.074 (16.36)(3.912)
Ms = 18.51 KN-m

Mb = Cb wLb2
Mb = 0.017 (16.36)(5.282)
Mb = 7.75 KN-m

Along Short Direction: Along Long Direction:


+ WDL = 4.12 + WDL = 4.12
+ MsDL = 0.030 (4.12) (3.91)2 + MbDL = 0.007 (4.12) (5.28)2
+ MsDL = 1.89 KN-m + MbDL = 0.80 KN-m

+ WLL = 12.24 + WLL = 12.24


+ MsLL = 0.049 (12.24) (3.91)2 + MbLL = 0.012 (12.24) (5.28)2
+ MsLL = 5.99 KN-m + MbLL = 4.09 KN-m

+ MTS = 1.89 + 5.99 + MbT = 0.80 + 4.09


+ MTS = 7.88 KN-m + MbT = 4.90 KN-m

Negative Moments at Discontinuous Edges Equal 1/3 of Positive Moment

Note : There is No Discontinuous Edge

Along the Short Direction:


1. Midspan:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 7.88 KN-m

7880000 = 0.90 (20.68) (1000) (100)2 w (1-0.59w)


w (1 - 0.59 w) = 0.04
w - 0.59 w2 = 0.04
0.59 w2 -w + 0.04 = 0
w2 -1.69 w + 0.072 = 0

By Quadratic Equation:
w = 0.0436

ρ = w fc' = 0.0033
fy

As = ρbd
As = 0.0033 (1000) (100)
As = 327.76 mm 2

Use 12 mm Bar Diameter

1000 Õ d2 327.76
S 4 =

S= 345.06 mm say 300.00 mm


2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 18.51 KN-m

18510000 = 0.90 (20.68) (1000) (100)2 w (1-0.59w)


w (1 - 0.59 w) = 0.10
w - 0.59 w2 = 0.10
0.59 w2 -w + 0.05 = 0
w2 -1.69 w + 0.1686 = 0
w = 0.1064

ρ = w fc' = 0.0080
fy

As = ρbd
As = 0.0080 (1000) (100)
As = 800.47 mm 2

Use 12 mm Bar Diameter

1000 Õ d2 800.47
S 4 =

S= 141.29 mm say 120.00 mm On Center

3. Discontinuous Edge:

Note : There is No Discontinuous Edge

Along the Long Direction:


1. Midspan d = 125 - 6 = 119.00 mm
Mu = Ø fc' bd w (1-0.59w)
2

Mu = 4.90 KN-m

4900000 = 0.90 (20.68) (1000) (119)2 w (1-0.59w)


w (1 - 0.59 w) = 0.02
w - 0.59 w2 = 0.02
0.59 w2 -w + 0.02 = 0
w2 -1.69 w + 0.032 = 0
w = 0.0189

ρ = w fc' = 0.0014
fy
As = ρbd
As = 0.0014 (1000) (119)
As = 168.74 mm 2

Use 10 mm Bar Diameter

1000 Õ d2 168.74
S 4 =

S= 465.46 mm say 450.00 mm On Center


2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 7.75 KN-m

7750000 = 0.90 (20.68) (1000) (100)2 w (1-0.59w)


w (1 - 0.59 w) = 0.04
w - 0.59 w =
2
0.04
0.59 w -w + 0.04 = 0
2

w2 -1.69 w + 0.0706 = 0
w= 0.0428

ρ = w fc' = 0.0032
fy

As = ρbd
As = 0.0032(1000) (100)
As = 322.21 mm 2

Use 10 mm Bar Diameter

1000 Õ d2 322.21
=
S 4

S= 243.75 mm say 220.00 mm On Center

3. Discontinuous Edge:

Note : No Discontinuous Edge

Note : For better and safer design of two-way slab, adopt the design on the plan.

PREPARED BY : PRC REG. NO. : 0087307 APPROVED BY :


DATE OF REG. : 06-14-2000
VALIDITY : 09-16-2012
PTR NO. : 8421556
EDWIN S. SALIGANAN ISSUED ON : 09-10-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: SAN JOSE CITY, NUEVA ECIJA
Job No. : Sheet No. : Revision :

1 1-4
Engineer : Date :
Job Title : A Proposed Split Level 4-Bedroom Residence Checked : Date :
Location : Brgy. Dizol, San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Bert Sevilla File : Dt/Tm :

DESIGN OF SUSPENDED TWO-WAY SLAB (S-1) TRIBUTARY AREA

DESIGN UNIT : METRIC

DESIGN DATA : INTERMEDIATE BEAM INTERMEDIATE BEAM


(SAME AS B-2)
5.28
INTERMEDIATE BEAM
(SAME AS B-2)
INTERMEDIATE BEAM
(SAME AS B-2)

B-1

B-1

B-1
SLAB 1 (S-1)

3.91
fc' = 20.70 MPa (3,000 Psi)
fy = 414.00 MPa Grade 40 Reinforcing Bar
B-2
COUNTER

B-3

B-3

B-3
B-3
qs = 96.00 KPa Soil Bearing Capacity COLUMN 2 (C-2)

Wc = 23.50 MPa Weight of Concrete


B-2
ENTRANCE

second floor line

Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

Minimum Thickness = perimeter of panel


180

Minimum Thickness = 150.00 mm say 150.00 mm

DEAD LOAD:
Try 150 mm Slab
Dead Load = 3.532 KPa

LIVE LOAD:

Live Load = 6.56 KN/m2

W = 1.4 DL + 1.7 LL
W = 4.94 + 11.15
W = 16.10 KN/m

Considering 1 meter strip


W = 16.10 KN/m

m= Ls = 6.00 = 0.8
Lb 7.50

Negative Moments From Table (Negative Moments at Continuous Edge), Case 2

Negative Cs = 0.071
Negative Cb = 0.029

Ms = Cs wLs2
Ms = 0.074 (16.36)(3.912)
Ms = 41.14 KN-m

Mb = Cb wLb2
Mb = 0.017 (16.36)(5.282)
Mb = 26.26 KN-m
AP E X L IN E OF ROOF

Job No. : Sheet No. : Revision :

2 .7 0
6 .1 0
TOP OF BE AM (MAS TER BEDROOM)

S E E A2 3 /8 FOR DETAIL

. 4 00 . .8 4 6 0 3 . 0 0
F
12
1 2-4
FFL (MAS TE R BEDROOM)
1 .2 6
Engineer : Date :
FIN . GR AD E LINE
FFL (KITCHEN)
NATUR AL G RADE LINE

Job Title : A Proposed Split Level 4-Bedroom Residence Checked : Date :


Location : Brgy. Dizol, San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Bert Sevilla File : Dt/Tm :

Along Short Direction: Along Long Direction:


+ WDL = 4.94 + WDL = 4.94
+ MsDL = 0.039 (4.94) (6)2 + MbDL = 0.016 (4.94) (7.5)2
+ MsDL = 6.94 KN-m + MbDL = 4.45 KN-m

+ WLL = 11.15 + WLL = 11.15


+ MsLL = 0.048 (11.15) (6) 2 + MbLL = 0.02 (11.15) (7.5)2
+ MsLL = 19.27 KN-m + MbLL = 12.55 KN-m

+ MTS = 1.89 + 5.99 + MbT = 0.80 + 4.09


+ MTS = 26.21 KN-m + MbT = 17.00 KN-m

Negative Moments at Discontinuous Edges Equal 1/3 of Positive Moment

Note : There is No Discontinuous Edge

Along Short Direction:


1. Midspan:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 26.21 KN-m

26210000 = 0.90 (20.70) (1000) (125)2 w (1-0.59w)


w (1 - 0.59 w) = 0.09
w - 0.59 w2 = 0.09
0.59 w -w + 0.09 = 0
2

w2 -1.69 w + 0.153 = 0

By Quadratic Equation:
w = 0.0957

ρ = w fc' = 0.0048
fy

As = ρbd
As = 0.0048 (1000) (125)
As = 598.27 mm 2

Use 12 mm Bar Diameter

1000 Õ d2 598.27
S 4 =

S= 189.04 mm say 180.00 mm


Job No. : Sheet No. : Revision :
A P E X L IN E OF R OOF

2 .7 0
6 .1 0
T OP OF BEAM (MA S T ER BE D
R OOM )

. 40 0 . 8 4 60 3 . 0 0
S EE A 2 3 /8 F OR DE T AIL

F
12

F FL (M AS TER BEDR OOM)

1 .2 6
1 3-4
F IN. GR AD E LINE
F F L ( KI TC HE N)
NA T UR A L GR ADE LINE

Engineer : Date :
Job Title : A Proposed Split Level 4-Bedroom Residence Checked : Date :
Location : Brgy. Dizol, San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Bert Sevilla File : Dt/Tm :

2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 41.14 KN-m 18510000

18510000 = 0.90 (20.68) (1000) (100)2 w (1-0.59w)


w (1 - 0.59 w) = 0.10
w - 0.59 w2 = 0.10
0.59 w2 -w + 0.05 = 0
w2 -1.69 w + 0.1686 = 0
w = 0.1063

ρ = w fc' = 0.0053
fy

As = ρbd
As = 0.0080 (1000) (100)
As = 531.68 mm 2

Use 12 mm Bar Diameter

1000 Õ d2 531.68
S 4 =

S= 212.72 mm say 150.00 mm On Center

3. Discontinuous Edge:

Note : There is No Discontinuous Edge

Along Long Direction:


1. Midspan d = 125 - 6 = 119.00 mm
Mu = Ø fc' bd w (1-0.59w)
2

Mu = 17.00 KN-m

4900000 = 0.90 (20.68) (1000) (94)2 w (1-0.59w)


w (1 - 0.59 w) = 0.02
w - 0.59 w2 = 0.02
0.59 w2 -w + 0.02 = 0
w2 -1.69 w + 0.032 = 0
w = 0.0188

ρ = w fc' = 0.0009
fy
As = ρbd
As = 0.0014 (1000) (119)
2
As = 112.08 mm 2

Job No. : Sheet No. : Revision :


A P E X L IN E OF R OOF

2 .7 0
6 .1 0
T OP OF BEAM (MA S T ER BE D
R OOM )

. 40 0 . 8 4 60 3 . 0 0
S EE A 2 3 /8 F OR DE T AIL

F
12

F FL (M AS TER BEDR OOM)

1 .2 6
1 4-4
F IN. GR AD E LINE
F F L ( KI TC HE N)
NA T UR A L GR ADE LINE

Engineer : Date :
Job Title : A Proposed Split Level 4-Bedroom Residence Checked : Date :
Location : Brgy. Dizol, San Jose City, Nueva Ecija Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Bert Sevilla File : Dt/Tm :

Use 10 mm Bar Diameter

1000 Õ d2 112.08
=
S 4

S= 700.74 mm say 470.00 mm On Center

2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 26.26 KN-m 7750000

7750000 = 0.90 (20.68) (1000) (100)2 w (1-0.59w)


w (1 - 0.59 w) = 0.04
w - 0.59 w = 2
0.04
0.59 w2 -w + 0.04 = 0
w2 -1.69 w + 0.0706 = 0
w= 0.0428

ρ = w fc' = 0.0021
fy

As = ρbd
As = 0.0032(1000) (100)
As = 214.02 mm 2

Use 10 mm Bar Diameter

1000 Õ d2 214.02
=
S 4

S= 366.97 mm say 250.00 mm On Center

3. Discontinuous Edge:

Note : For better and safer design of two-way slab, adopt the design on the plan.

PREPARED BY : PRC REG. NO. : 0093332 APPROVED BY :


DATE OF REG. : 05-30-2002
VALIDITY : 09-27-2009
PTR NO. : 8406619 MR. & MRS. BERT SEVILLA
ANDY G. GAGELONIA ISSUED ON : 02-18-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: BRGY. DIZOL, SAN JOSE CITY, N.E.
Revision :

TRIBUTARY AREA

5.28
INTERMEDIATE BEAM INTERMEDIATE BEAM INTERMEDIATE BEAM INTERMEDIATE BEAM
(SAME AS B-2) (SAME AS B-2) (SAME AS B-2)
B-1

B-1

B-1
SLAB 1 (S-1)
3.91

B-2
COUNTER
B-3

B-3

B-3
B-3

COLUMN 2 (C-2)
B-2
ENTRANCE

second floor line


Revision :
Revision :
Revision :

APPROVED BY :
MR. & MRS. BERT SEVILLA
PROJECT OWNER
ADDRESS: BRGY. DIZOL, SAN JOSE CITY, N.E.
Job No. : Sheet No. : Revision :

1 1-4
Engineer : Date :
Job Title : Proposed Two-Storey Residential Building Checked : Date :
Location : Lot 32 Blk 10, Canterbury St., Hillborugh Vill., Alabang, Muntinlupa Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Alexis Agoncillo File : Dt/Tm :

DESIGN OF SUSPENDED TWO-WAY SLAB (S-1) TRIBUTARY AREA

DESIGN UNIT : METRIC

DESIGN DATA :

fc' = 20.70 MPa (3,000 Psi)


fy = 276.00 MPa Grade 40 Reinforcing Bar
qs = 96.00 KPa Soil Bearing Capacity
Wc = 23.50 MPa Weight of Concrete
Cc = 40.00 mm Concrete Cover

LOAD COMPUTATIONS :

Minimum Thickness = perimeter of panel


180

Minimum Thickness = 150.00 mm say 150.00 mm

DEAD LOAD:
Try 150 mm Slab
Dead Load = 3.532 KPa

LIVE LOAD:

Live Load = 6.56 KN/m2

W = 1.4 DL + 1.7 LL
W = 3.30 + 8.16
W = 16.10 KN

Considering 1 meter strip


W = 16.10 KN/m

m= Ls = 6.00 = 0.8
Lb 7.50

Negative Moments From Table (Negative Moments at Continuous Edge), Case 4

Negative Cs = 0.071
Negative Cb = 0.029

Ms = Cs wLs2
Ms = 0.071 (16.10)(62)
Ms = 41.14 KN-m

Mb = Cb wLb2
Mb = 0.029 (16.1)(32)
Mb = 26.26 KN-m
Job No. : Sheet No. : Revision :

2 . 00 0. 3 2
MAI N APEX L I NE

3 .2 0 2 .3 2
SECON DARY APEX LI NE

1 . 1 13 . 6 1 2 . 0 5
F I N. CON C. R OOF L EDGE L I NE

2 .6 7
TO P OF ROO F BEAM LIN E
L O WER AP E
X L I NE

8 .7 2
L OW ER T OP OF RO OF BEAM L I NE

5 .9 5
FI
N . SECO ND F L OOR L I NE F I N. S ECOND F L OO R LI NE

4 .3 3
1 2- 4

3 .2 0
0 .7 0
FI
N . G ROUND FL OO R LIN E FI N. GR OUND F L OO R LI NE

0 .7 0
FI
N . G ARAGE / LA ND DEV' T L I NE FIN . GA RAGE / LAN D DEV' T L I NE

F R ONT E LEV ATI ON


sca l
e 1 :10 0 mt s

Engineer : Date :
Job Title : Proposed Two-Storey Residential Building Checked : Date :
Location : Lot 32 Blk 10, Canterbury St., Hillborugh Vill., Alabang, Muntinlupa Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Alexis Agoncillo File : Dt/Tm :

Along Short Direction: Along Long Direction:


+ MsDL = 0.039 (4.94) (6)2 + WDL = 4.94
+ MsDL = 6.94 KN-m + MbDL = 0.016 (4.94) (7.5)2
+ MsLL = 0.048 (11.15) (6)2 + MbDL = 4.45 KN-m
+ MsLL = 19.27 KN-m
+ WLL = 11.15
+ MTS = 0.80 + 2.35 + MbLL = 0.020 (11.15) (7.5)2
+ MTS = 26.21 KN-m + MbLL = 12.55 KN-m

+ MbT = 4.45 + 12.55


+ MbT = 17.00 KN-m

Negative Moments at Discontinuous Edges Equal 1/3 of Positive Moment

- MS = (1/3) * (26.21) - Mb = (1/3) * (17.00)


- MS = 8.74 KN-m - Mb = 5.67 KN-m

Along Short Direction:


1. Midspan:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 26.21 KN-m

26210000 = 0.90 (20.68) (1000) (125)2 w (1-0.59w)


w (1 - 0.59 w) = 0.09
w - 0.59 w2 = 0.09
0.59 w2 -w + 0.09 = 0
w2 -1.69 w + 0.153 = 0

By Quadratic Equation:
w = 0.0960

ρ = w fc' = 0.0072
fy

As = ρbd
As = 0.0048 (1000) (125)
As = 899.85 mm 2

Use 12 mm Bar Diameter

1000 Õ d2 899.85
S 4 =

S= 125.68 mm say 180 mm On Center


Job No. : Sheet No. : Revision :

2 . 00 0. 3 2
MAI N APEX L I NE

3 .2 0 2 .3 2
SECON DARY APEX LI NE

1 . 113 . 612 . 0 5
F I N. CON C. R OOF L EDGE L I NE

2 .6 7
TO P OF ROO F BEAM LIN E
L O WER AP E
X L I NE

8 .7 2
L OW ER T OP OF RO OF BEAM L I NE

5 .9 5
FI
N . SECO ND F L OOR L I NE F I N. S ECOND F L OO R LI NE

4 .3 3
3 .2 0
1 3- 4
0 .7 0
FI
N . G ROUND FL OO R LIN E FI N. GR OUND F L OO R LI NE

0 .7 0
FI
N . G ARAGE / LA ND DEV' T L I NE FIN . GA RAGE / LAN D DEV' T L I NE

F R ONT E LEV ATI ON


s c al
e 1 :1 0 0 mts

Engineer : Date :
Job Title : Proposed Two-Storey Residential Building Checked : Date :
Location : Lot 32 Blk 10, Canterbury St., Hillborugh Vill., Alabang, Muntinlupa Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Alexis Agoncillo File : Dt/Tm :

2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 41.14 KN-m

12460000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.12
w - 0.59 w2 = 0.12 0.20339
0.59 w2 -w + 0.12 = 0
w2 -1.72 w + 0.2034 = 0
w = 0.1277

ρ = w fc' = 0.0096
fy

As = ρbd
As = 0.0096 (1000) (75)
As = 718.31 mm 2

Use 10 mm Bar Diameter

1000 Õ d2 718.31
S 4 =

S= 109.34 mm say 100.00 mm On Center

3. Discontinuous Edge:

Use 3 times the spacing of midspan (moment is only 1/3 of midspan)


S = 3(200) = 540 mm > 500 mm (ACI Code)
Bent up two of every three bars from the bottom steel

Along Long Direction:


1. Midspan d = 100 - 6 = 94.00 mm
Mu = Ø fc' bd w (1-0.59w)
2

Mu = 17.00 KN-m

4870000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.02
w - 0.59 w2 = 0.02
0.59 w2 -w + 0.10 = 0
w2 -1.72 w + 0.169 = 0
w= 0.105

ρ = w fc' = 0.0079
fy
As = ρbd
As = 0.0079 (1000) (94)
2
As = 740.25 mm 2

MAIN A PEX LINE

2 .0 0 0 .3 2
2 .3 2
SECONDARY APEX LINE

FIN. CONC. ROOF LEDGE LINE Job No. : Sheet No. : Revision :

1 .1 3 1 .6 2 1 .0 5
TOP OF ROOF B EAM LINE
LOWER AP EX LINE

2 .6 7
3 .2 0
8 .7 2

LOWER TOP OF ROOF BEAM LINE

FIN. SECOND FLOOR LINE FIN. SECOND FLOOR LINE

1 4- 4

5 .9 5
4 .3 3
3 .2 0

Engineer : Date :
FIN. GROUND FLOOR LINE FIN. GROUND FLOOR LINE
0 .7 0

FIN. GARAGE / LAND DEV 'T LINE FIN. GA RAGE / LA ND DEV'T LINE

0 .7 0
Job Title : Proposed Two-Storey Residential Building FRONT ELEVATION
scale 1:100 mts Checked : Date :
Location : Lot 32 Blk 10, Canterbury St., Hillborugh Vill., Alabang, Muntinlupa Approved : Date :
Subject : Structural Design Analysis Client : Mr. & Mrs. Alexis Agoncillo File : Dt/Tm :

Use 10 mm Bar Diameter

1000 Õ d2 740.25
=
S 4

S= 106.10 mm say 100.00 mm On Center

2. Continuous Edge:
Mu = Ø fc' bd2 w (1-0.59w)
Mu = 26.26 KN-m

6090000 = 0.90 (20.68) (1000) (75)2 w (1-0.59w)


w (1 - 0.59 w) = 0.06
w - 0.59 w =2
0.06
0.59 w2 -w + 0.06 = 0
w2 -1.72 w + 0.1017 = 0
w= 0.0613

ρ = w fc' = 0.0046
fy

As = ρbd
As = 0.0046 (1000) (75)
As = 344.81 mm 2

Use 10 mm Bar Diameter

1000 Õ d2 344.81
=
S 4

S= 227.78 mm say 200.00 mm On Center

3. Discontinuous Edge:

Use 3 times the spacing of midspan (moment is only 1/3 of midspan)


S = 3(100) = 300.00 mm On Center

Note : For better and safer design of two-way slab, adopt the design on the plan.

PREPARED BY : PRC REG. NO. : 0093332 APPROVED BY :


DATE OF REG. : 05-30-2002
VALIDITY : 09-27-2009
PTR NO. : 8406619 MR. & MRS. ALEXIS AGONCILLO
ANDY G. GAGELONIA ISSUED ON : 02-18-2009 PROJECT OWNER
Civil Engineer ISSUED AT : Science City of Muñoz, N.E. ADDRESS: SAN JOSE CITY, NUEVA ECIJA
Revision :

TRIBUTARY AREA
Revision :
Revision :
Revision :

APPROVED BY :
MR. & MRS. ALEXIS AGONCILLO
PROJECT OWNER
ADDRESS: SAN JOSE CITY, NUEVA ECIJA

You might also like