You are on page 1of 4

PSV Calculation Report - Gas / Vapor Relief Sizing Case

PSV General Data

Item 100 PSV 001 A Design Code ASME VIII

Service Design Temperature 75.00 °C

Fluid Feed Gas @TPL4 Relief Phase Vapor Fire Case False

Valve Type Pilot Operated Sizing Method Vapor Emergency Blocked Outlet

Body Mat'l Carbon Steel Rupt. Disk False Discharge To Flare

Fluid Properties @ Relieving PSV Coefficients

Spec Heat Ratio (K) 1.2643 Molecular Weight 19.28 C 343.5 Kb 1.000
8 0
Gas Compressibility (Z) 0.9007 Viscosity 0.0136 cP Kd 0.975 Kc 1.000
0 0

Process Data @ Relieving

Atm. Pressure 1.01 barA Superimposed Const. 1.01 barA


Back Press.
Var. 0.00 bar
Relieving Flow 128900.00 kg/h

Relieving Temp 50.00 °C Builtup Back Press 4.50 bar

Set Pressure 45.00 barG Total Back Press 4.50 barG

Over Pressure 16.0 % Max. Allowable Back Press: 33.75 barG

Valve Sizing Results

Type of Flow Critical Selected Orifice 41.16 cm² % Used 89.8 %

Calculated Orifice 36.96 cm²


Orifice Designation 4 "# 600 P 6 "# 150
Noise 121.83 dBA @ 30.00 m
Reaction Forces 14130.13 N

Inlet / Outlet Lines Sizing Results

N.D. Eq. Calc. Calc. Max Avg Avg Exit Crit. Crit.
I.D. Rough.
Sch. Length Flow DP DP vel. Rho v2 Vel. Vel. Press.
(in)
(in) mm m kg/h bar bar m/s kg/m/s² m/s m/s barG

IN 6 80 5.76 0.0457 5.00 143535.81 0.39 1.35 63.43 150376.99 - - -

OUT 24 STD 23.25 0.0457 5.00 143535.81 0.01 33.75 189.79 27627.16 196.35 419.74 0.60

Calculation Notes

Record 1 of 4 8/8/2019 10:59:33 PM


PSV Calculation Report - Gas / Vapor Relief Sizing Case

PSV General Data

Item 100 PSV 001 B Design Code ASME VIII

Service Design Temperature 75.00 °C

Fluid Feed Gas @TPL4 Relief Phase Vapor Fire Case False

Valve Type Pilot Operated Sizing Method Vapor Emergency Blocked Outlet

Body Mat'l Carbon Steel Rupt. Disk False Discharge To Flare

Fluid Properties @ Relieving PSV Coefficients

Spec Heat Ratio (K) 1.2643 Molecular Weight 19.28 C 343.5 Kb 1.000
8 0
Gas Compressibility (Z) 0.9007 Viscosity 0.0136 cP Kd 0.975 Kc 1.000
0 0

Process Data @ Relieving

Atm. Pressure 1.01 barA Superimposed Const. 1.01 barA


Back Press.
Var. 0.00 bar
Relieving Flow 128900.00 kg/h

Relieving Temp 50.00 °C Builtup Back Press 4.50 bar

Set Pressure 47.25 barG Total Back Press 4.50 barG

Over Pressure 10.5 % Max. Allowable Back Press: 35.44 barG

Valve Sizing Results

Type of Flow Critical Selected Orifice 41.16 cm² % Used 89.8 %

Calculated Orifice 36.96 cm²


Orifice Designation 4 "# 600 P 6 "# 150
Noise 121.83 dBA @ 30.00 m
Reaction Forces 14130.13 N

Inlet / Outlet Lines Sizing Results

N.D. Eq. Calc. Calc. Max Avg Avg Exit Crit. Crit.
I.D. Rough.
Sch. Length Flow DP DP vel. Rho v2 Vel. Vel. Press.
(in)
(in) mm m kg/h bar bar m/s kg/m/s² m/s m/s barG

IN 6 80 5.76 0.0457 5.00 143535.81 0.37 1.42 60.47 143366.52 - - -

OUT 24 STD 23.25 0.0457 5.00 143535.81 0.01 35.44 189.79 27627.16 196.35 419.74 0.60

Calculation Notes

Record 2 of 4 8/8/2019 10:59:33 PM


PSV Calculation Report - Gas / Vapor Relief Sizing Case

PSV General Data

Item 100 PSV 001 C Design Code ASME VIII

Service Design Temperature 75.00 °C

Fluid Feed Gas @TPL4 Relief Phase Vapor Fire Case False

Valve Type Pilot Operated Sizing Method Vapor Emergency Blocked Outlet

Body Mat'l Carbon Steel Rupt. Disk False Discharge To Flare

Fluid Properties @ Relieving PSV Coefficients

Spec Heat Ratio (K) 1.2643 Molecular Weight 19.28 C 343.5 Kb 1.000
8 0
Gas Compressibility (Z) 0.9007 Viscosity 0.0136 cP Kd 0.975 Kc 1.000
0 0

Process Data @ Relieving

Atm. Pressure 1.01 barA Superimposed Const. 1.01 barA


Back Press.
Var. 0.00 bar
Relieving Flow 128900.00 kg/h

Relieving Temp 50.00 °C Builtup Back Press 4.50 bar

Set Pressure 47.25 barG Total Back Press 4.50 barG

Over Pressure 10.5 % Max. Allowable Back Press: 35.44 barG

Valve Sizing Results

Type of Flow Critical Selected Orifice 41.16 cm² % Used 89.8 %

Calculated Orifice 36.96 cm²


Orifice Designation 4 "# 600 P 6 "# 150
Noise 121.83 dBA @ 30.00 m
Reaction Forces 14130.13 N

Inlet / Outlet Lines Sizing Results

N.D. Eq. Calc. Calc. Max Avg Avg Exit Crit. Crit.
I.D. Rough.
Sch. Length Flow DP DP vel. Rho v2 Vel. Vel. Press.
(in)
(in) mm m kg/h bar bar m/s kg/m/s² m/s m/s barG

IN 6 80 5.76 0.0457 5.00 143535.81 0.37 1.42 60.47 143366.52 - - -

OUT 24 STD 23.25 0.0457 5.00 143535.81 0.01 35.44 189.79 27627.16 196.35 419.74 0.60

Record 3 of 4 8/8/2019 10:59:33 PM


PSV Calculation Report - Gas / Vapor Relief Sizing Case

Calculation Notes

Record 4 of 4 8/8/2019 10:59:33 PM