You are on page 1of 4

OxyM Oxygen Mixer

Air/Oxygen Blender for the NICU

Save Gas, Time and Money.


A Perfect Mixing of O2 for a Variety of Application
The Quality, Reliability and Versatility of OxyM Blenders are
designed as per the standard to meet the ICU & NICU requirements.
Dual Flow Meter
The OxyM Blender with integrated owmeters
specically designed for use in the NICU.
The 0-15LPM owmeter on the left can be used to
connect to a Resuscitator nCPAP, BCPAP. The owmeter
on the right,which can be xed in 0-15, 0-3.5 or 0-1.0LPM,
can be used to connect an infant nasal cannula.
Bleed Turn ON/OFF
The OxyM blenders unique features is the bleed knob can be ON/OFF by
pushing the knob. It is saving time and reduce frustration,
because there are no parts to disconnect and misplace, and the OxyM
Blender is always ready to use.
nice 5005
Low Flow Blender
nice 5010 (Low Flow Blender Specic for
NICU Applications)
Optional : Flow meter
0-15 LPM Primary Left Side.
0-1/ 0-3 LPM Auxiliary Right Side.
Perfect for NICU and Newborn nursery
or for a ow of 30 Ipm or less. Increased
accuracy at even the lowest ow range.
nice 5010
High/Low Flow Blender
Optional : Flow meter
0-15 LPM Primary Left Side.
0-1/0-3 LPM Auxiliary Right Side.
Versatile dual range blender. Ideal for
equipment needing ows of 120 Ipm,
yet also capable of increased accuracy nice 5005
even at a low ow range.

nice 5010
High-ow blender with
(30+30) cascade ow meter (optional)

nice 5005 Low Flow Blender


with Cascade Flow meter
Air Oxygen blender for Heart Lung /
Neonatal Care has been specially designed
with 10 lpm and 1 lpm cascade ow meter
at a resolution of 100 ml with +3% _ FIO2
accuracy at any set point and Oxygen
concentration control 21 to 100%.
It features gas supply failure alarm and has
a minimum bleed of 2.5 lpm facilitated with
bleed ON/OFF facility.

nice 5010 High Flow Blender


with Cascade Flow meter

Air Oxygen Blender for high ow therapy


has been specially designed with 60 LPM
nice 5005
ow meter (30 + 30 Lpm) at precise low-ow blender
resolution 2.5 litres with +3% _ FiO 2 with (10+1) lpm
accuracy at any given set point and Oxygen cascade ow
Concentration control 21 to 100% it also meter (optional)
features an gas supply failure alarm and
has a minimum bleed of 3 lpm facilitated
with bleed ON/OFF facility.
nice 5005
Air Oxygen Blender for Bubble CPAP, nasal CPAP
High Flow Therapy Applications

nice 5005
Air Oxygen Blender for
Infant 'T' Piece Resuscitator & Humidier
To Provide continuous supply of Air and
Oxygen Blender Gas for Bubble CPAP
and T Piece Resuscitator.

Unique Features
nice 5005 and nice 5010 have gas savings ON/OFF bleed feature.
Available in very low to high ow capability.
Suited to specialty and general needs.
Mounting Solutions for all situations.
All blender are equipped with an audible alarm.

Applications
OxyM Medical Air/O2 blenders combine compressed Medical Air and Oxygen to deliver blended pressurized gas at a
precise oxygen concentration (FIO2) rm by the user.
All Device equipped with a unique gas bleed ON/OFF switch to increase accuracy when needed, conserve gas,
save money and time.
These blenders are suitable for respiratory applications including routine therapy, ventilator gas and supply, Bubble CPAP,
SiPAP, nCPCP Resuscitator and critically -limited NICU procedures.
nice Neotech offer different models with multiple Outlet ports that deliver the same highly accurate selected FiO2.
Most models can be customized to include the owmeter attachment with a variety of ow rates available.
The blenders contains an audible alarm which warns the user if either of the gas sources changes by more than
20 PSI from the other.
Air and Oxygen blenders require a Bleed for good accuracy at low ow range less than 15 lpm. The Bleed ON
a blender is activated by the knob, which is placed on the right port. This facility avoids the blended gas being
into the air when the blender is not in use.
(0 to 3 lpm)
88-00-139

Flow meter
(optional)
O2 Pressure Regulator Air Pressure Regulator
Air Inlet Hose
(optional) (optional)
50-05-131 50-05-130 (0 to 15 lpm) (optional) 50-20-171
88-00-105

Blender Blender Blender


Oxygen Inlet Hose Pole Mounting Bracket Rail Mounting Bracket Wall Mounting Bracket
(optional) 30-20-067 (optional) 50-05-129 (optional) 50-05-140 (optional) 50-05-127

Specications
nice 5005 nice 5010
Oxygen Concentration Range 21-100% 21-100%
FiO2 Accuracy _
+3% of full scale _
+3% of full scale
Alarm Activation bypass _ PSI
When supply pressure differs 20+2 _ PSI
When supply pressure differs 20+2
Alarm Type Reed alarm, 80db minimum at 1 foot Reed alarm, 80db minimum at 1 foot
Primary Outlet Flow Range (left
Up to 30 LPM Up to 120 LPM
side Outlet)
Auxiliary Outlet Flow Range (Right
side Outlet) 0-30 LPM 2-120 LPM
2
Bleed Flow at 50 PSI (3.5kg/cm ) 2.5 to 3.5 LPM 10 to 12 LPM
Inlet Gas Supply Pressure 30 to 75 PSIG (2.1 to 5.3kg/cm2) 30 to 75 PSIG (2.1 to 5.3kg/cm2)
DISS (Standard) DISS (Standard)
Gas Inlet Fittings
NIST (Optional) NIST (Optional)
Operating Temperature 15 to 40°C 15 to 40°C
Storage Temperature -20 to 60°C -20 to 60°C
Operating Humidity 15 to 95% noncondensing 15 to 95% noncondensing
Storage Humidity 0 to 95 % noncondensing 0 to 95 % noncondensing
MDD - Product Classication Class llb Class llb
Quality Management System ISO 13485 ISO 13485
Device Specic standard ISO 11195 ISO 11195
Dimension (Excluding ttings) 9cm (H) X 6cm (W) X 9.5cm (D) 9cm (H) X 6cm (W) X 9.5cm (D)
Weight 1.25 kg 1.25 kg
nice 5020
Number of ports Two Two
T - Piece Resuscitator
with Blender
74-00-021, Rev 03

An ISO 13485 Certified Company (With Design)