DEAERATOR TROUBLESHOOTING AND


PREVENTIVE MAINTENANCE

Home (https://www.engineeringequipmentindia.com) 

Deaerator Troubleshooting and Preventive Maintenance

DEAERATOR TROUBLESHOOTING AND PREVENTIVE


MAINTENANCE
 posted by: DEEPA KASTURIRANGAN  JULY 9, 2019  NO COMMENTS

Topics on this blog

1. Theory of Deaeration
2. Spray and Tray Cascading System
3. Deaerator Trouble Shooting
4. Preventive Maintenance of Deaerator

Deaerator is an equipment used for the removal of impurities from feed water like dissolved oxygen, carbon
monoxide, carbon dioxide and content of Sulphur.  In addition to removing free oxygen and dissolved gases, a
Deaerator provides the advantage of heating boiler feedwater. Expansion and contraction of heating surfaces and the
thermal shock are reduced and also a reduction in fuel consumption by adding hot feedwater to a boiler.

THEORY OF DEAERATION

Dissolved gas is removed by reducing the partial pressure of that particular gas in the surrounding atmosphere.
The solubility of any gas dissolved in any is directly proportional to the partial pressure of gas above the liquid.
The heating system is provided with trays, steam header inside the Deaerator.
The rst row of trays are designed to act as a condensing stage which allows only the non-condensable gases
to escape and vent losses of steam is appreciably controlled.

The Deaerator is made of two parts:


– In the upper tank, deaeration is done and the water is heated

– In the lower tank, deaerated feed water is stored.

SPRAY & TRAY CASCADING SYSTEM

In order to accomplish a high degree of ef cient deaeration, water is sprayed through various spray nozzles
arranged below the water header.
When water enters the nozzle at pressure, ne mist generated by whirling action of vanes.
Mist so created passes through various stages of trays arranged in rows.
Incoming steam not only heats the tray but also removes dissolved gases.

By the time water reaches

1. Stage 5 – Devoid of O2& CO.


2. Stage 7 – Co2
3. Stage 8 – So2

Condensation of steam is reduced to the negligible degree because of already preheated water and most of the
steam remains at vapour.

DEAERATOR TROUBLESHOOTING/ PROBLEMS IN DEAERATOR

Why Oxygen O2 Level is High in Deaerator?

A heater is speci ed to ensure minimum O2 levels of 7 ppb.

The Oxygen level can go high in the Deaerator if there are any loose ttings which result in the air in ltration.

The other reasons for High O2 can be because of Trays not installed properly in place, O² inlet not in accordance with
speci ed designed conditions, Water inlet temperature can be too low, Spray valves not installed correctly.

Even if the stabilization period is insuf cient the O2 levels will be high. The improper venting can also cause High
Oxygen level in a deaeration system.

Why the outlet temperature of Deaerator low?

The calibration of the thermometer can be wrong which can show the incorrect Thermometer reading.

If the steam ow is insuf cient, Heater will be ooding or if the Inlet Flow is not piped correctly the temperature can
indicate low temperature.

The ratio of the Steam and water should be correct for the correct outlet temperature.

If the Pipe and Valve sizing in not correct the spray valves will not function properly to give proper temperature.

It is good to check all valve and control settings, and inlet ows and temperatures periodically to prevent damage.

 
Why there is Excessive Pressure uctuation in Deaerator?

Steam Pressure Reducing Valve, downcomer, and equalizer may be improperly sized or calibrated.

The Inlet steam pressure can be too high or too low or there could be excessive inlet temperature variation to cause
uctuation.

Even if the heater is ooding there could be excessive pressure uctuation. The design should be within the design
range to avoid pressure uctuation.

Why Water Hammering in Deaerator?

Water hammering can happen when the designing is not as per the parameters.

The inlet ows mixing just prior to Deaerator inlet can cause water hammering it is better to design to mix ows
farther upstream of Deaerator.

High inlet velocities and Improper pipe design is also the reason for water hammering.

It is good to redesign as per the HEI parameters.

Why Carbon Di Oxide CO2 is high in Deaerator?

High CO2 at the inlet then the CO2 would be higher in the Deaerator.

If the ph level of incoming water is High the CO2 will be higher, than, it is good to lower the ph level by controlling
the level of dozing in the DM plant to reduce the CO2.

CO2 will be high if the venting is improper.

Why Iron Oxide in Deaerator?

A possible reason for Iron oxide in Deaerator could be due to incoming Condensate or system corrosion which can
happen if positive pressure is not maintained in the Deaerator.

Frequent shutdowns can cause Iron Oxide in Deaerator.

Higher Oxygen levels in Deaerator can also result in Iron Oxide.

The vent piping should be short and as vertical as possible to avoid Iron Oxide in Deaerator.

The vent ow should be proper to avoid water carryover which could also be the reason for Iron oxide.

Why Sudden/ unexpected Deaerator storage tank level excursions?

The reason for sudden storage tank level excursions can be due to the malfunctioning of the control systems.
It is also good to check the over ow level and boiler feed pump operation to rectify the malfunctioning over ow or
improper boiler.

Even if there is a Pressure uctuation the Deaerator tank would be ooding.

Why Deaerator Tray Upsets/ Tray Abuse?

Tray abuse is created when much colder condensate suddenly enters the feed box and is sprayed in the spray chamber,
rapidly lowering pressures just above the trays. This results in ashing and both steam and water want to move-up
rapidly or even violently through the trays.

The typical tray design features a series of level trays having multiple slots with raised lips. In this arrangement water
falling vertically in a thin lm to the tray below hits the tray surface and must travel horizontally before falling to the
next tray.

The Tray Upset problem may arise when the partial pressure above the water in the storage tank drops enough to
permit ashing of the stored water allowing a mixture of steam and water to shoot quickly.

PREVENTIVE MAINTENANCE OF DEAERATOR

1. Check the ph level in DM plant


2. Check for the Thermometer calibration
3. Check the ttings all valve and control settings.
4. Check the blocks in vents
5. Check all inlet ows and temperatures
6. Check steam supply
7. Check Steam and water ratio and check for restrictions
8. Check all valve and control settings
9. Check Pipe and valve sizing
10. Check ow level and boiler feed pump operation

Categories Blog (https://www.engineeringequipmentindia.com/category/blog/)

Post comment

Name
E-mail

Message

POST COMMENT RESET

About EEI

Engineering equipment India group having of ce in Chennai, India is a pioneer in manufacturing, design & detail
engineering and providing quick solution to boiler breakdown. We are experts in Re-Engineering. EEI group is a
manufacturer and supplier of Process Industry Equipment, Power & Steam Generation Equipment, Pulp & Paper
Equipment, Chemical Plant Equipment and Oil & Gas Field Equipment. Flue gas De-sulphurisation system,
Incinerators, Heat Exchangers, and Pressure Vessels is our speciality. We also undertake Operations & Maintenance in
India.

All rights reserved - Engineering Equipment India

(https://www.facebook.com/engineeringequipmentindia/)
(https://www.linkedin.com/company/engineeringequipmentindia)
 

You might also like