Item number Service Size Unit Price Qty Extended Price


001 10M $ 56,825.27 1 $56,825.27

SCOPE OF SUPPLY: Only the material detailed in this quotation is being offered. No assumption should be made that
anything not specifically defined is included.

VALIDITY: This quotation is valid for 30 days.

PRICE: The price quoted is for all items purchased at one time. Partial orders may be subject to a price adjustment.

PAYMENT TERMS: 2 % 10 days, net 30 days.

FREIGHT: Please see individual item price sheets.

PACKAGING: Please see individual item price sheets.

SHIPMENT: Approximately 10 to 12 weeks after our acceptance of your written purchase order.

WARRANTY: 12 months from commissioning or 18 months from shipment whichever is the sooner.

START-UP: Not included.

EXPORT CONTROL: The commodities, technology or software in this Quotation are subject to the U.S. Export
Administration Regulations (EAR). Exporting from the United States may require an export license. Diversion of these items
contrary to U.S. law is prohibited. Please contact us if you have any questions.

TERMS AND CONDITIONS: Our standard terms and conditions are attached.

Page 2 of 31
Customer : Customer Technical Offer
cv Project name : Encompass 2.0 - 20.2.4
SAN SALVADOR Sal

Item number 001 Size / Stages /


Quote number CLN03082020 Pump speed

Pump
Qty Description
1 Vertical Turbine Fire Pump 10M
COS
Conditions of service
Flow: 250 USgpm (57 m3/h)
Pressure required at flange: 125 psi (8.62 bar)
Pump Speed: 1770 RPM
Maximum lift: 8.43 ft. (2.57 m.)
Bowl pressure: 128.65 psi (8.87 bar)
Overall Length: 118.11 in (9.84 ft. / 3 m.)
UL Listed: Yes
FM Approved: Yes
Elevation: 2263.77952756 ft. (690 m.)
Ambient temp: 93.2°F (34°C)
Pump BHP: 44 Hp
Overall length confirmation: Confirming overall length of pump is 118.11 in (9.84 ft. / 3 m.) as measured from the bottom of the soleplate to
the bottom of the suction strainer.
Fire pump configuration
Pump
Vertical pump module
Bowl assembly: 6 stage, 10M
Basket Strainer: Bronze
Discharge head: 16.5" X 6", "CT"
Discharge head rating: 125 Lb.
Threaded column: Length 5 Ft., Size 6"
Open line shaft: Length 5 Ft., Size 1"
Total column: Length 4.55 Ft.
Fittings module: Discharge pressure gauge & 2" Automatic air release valve

Driver
Qty Description
1 Driver
Driver type
Is pump discharge pressure less than 80psi at 150% of rated flow?: No
Will the pump discharge water temperature be greater than 100° F?: No
Engine: Clarke JU4H-UFH0 73HP 1760rpm 12V, Heat exchanger cooled, Emission level Tier 1
Cooling loop adders: Standard cooling loop
Engine Kit number: KIT F4002
Driver options
Available HP: 65.49
Water jacket heater / Battery charger voltage: 115 Volt
Drive shaft: CDS20-SC UL Driveshaft w/ Flange & Guard
Battery type: Lead acid
Engine battery volt: 12 Volt DC
Engine frequency operation: 60 Hz

: +52 667 759 0470 · :

Page 3 of 31
Customer SAN SALVADOR Customer Technical Offer
Encompass 2.0 - 20.2.4
Project name : Sal
Gear drive
Qty Description
1 Driver
Gear box
Gear box: Randolph G60, 1:1 - Includes non-reverse ratchet
Gear box shipping: Ship from factory

Fire Pump Controller


Qty Description
1 Fire pump controller
Fire pump controller
Fire pump controller: Tornatech GPD
Battery Voltage: 12V
Fire pump controller - alarm and indicators
Standard LED's
AC power on
Main switch in auto
Battery 1 failure Battery
2 failure Charger 1
failure Charger 2 failure
Engine low oil pressure
Engine high oil pressure
Engine overspeed
Engine run

Engine fail to start Fail


when running Pump
room alarm Deluge valve
Weekly test Controller
trouble Standard alarm
contacts Engine run

Engine trouble
Controller trouble
Pump room alarm
Fire pump controller - additional option selections
Enclosure: NEMA 2
Space heater: None
Pressure transducer: Pressure transducer and run test solenoid valve for fresh water rated for 0-500 psi (factory calibrated)
Low fuel level float switch: None
High fuel level float switch: None
Base mounted controllers: No
Pump control function: None
Float switch: None
Labelling language: English
Modbus: Modbus TCP/IP provision

Jockey Pump
Qty Description
1 Jockey pump Pump
and Motor Pump type:
Submersible
: +52 667 759 0470 · :

Page 4 of 31
Customer Customer Technical Offer
Encompass 2.0 - 20.2.4
Project name : SAN SALVADOR
Jockey Pump
Qty Description
Flow rate: 2.5 USgpm
TDH: 135 psi: 135.0 psi
JP Details: L20P4FH, 60 Hz, 1.5 Hp.
Frequency: 60 Hz
Phase: Three
Motor Voltage: 230 Volt
Jockey pump motor: 3-Wire Motor, 60 Hz, 3 Ph, 230 Volt, 1½ Hp, without magnetic starter
Watson McDaniel relief valve: 1/2"
Controller
JP controller details: Tornatech Model JP3, Across-The-Line, 230V, 3 Phase, 60 Hz, 1.5 Hp

Jockey Pump Controller


Qty Description
1 Jockey pump
Controller
Manufacturer: Tornatech
Starting method: Across-The-Line
Voltage: 230 V
Horsepower: 1.5Hp
Jockey pump controller
options Enclosure: NEMA 2
Pressure switch: Pressure transducer 0-600psi 316SST
Wetted parts: None
Labeling language: English
Space heater: None
Pump control function: None

System Accessories
Qty Description
1 Driver Accessories
Diesel engine Muffler:
Industrial grade
Fuel tank: Single wall, 119 US gallon tank, 105 usable US gallons, NFPA 20 & UL 142 (per NFPA 20 & UL 142)
Fuel tank Diameter: 24 inches: 24
Accessories System
Accessories Hose valve
manifold: None Angle type
hose valves: None
Ball drip valve: 0.5" ball drip valve
Main relief valve: 3", 125 lb, Kunkle valve Flow range (250 - 500 US GPM)
Enclosed waste cone details: 3" X 5", waste cone
Flow meter details: Global Vision Venturi type, Grooved, 250 GPM, size 4"
Vertical turbine water level kit: None

Engineering Tests
Qty Description
1 Testing and Certifications
Driver and Engineering Tests / SASO Compliance
Driver to be used for engineering tests: Calibrated test lab motor
Engineering tests

: +52 667 759 0470 · :

Page 5 of 31
Customer Customer Technical Offer
Encompass 2.0 - 20.2.4
Project name :SAN SALVADOR
Engineering Tests
Qty Description
Certified performance test
Performance test of Bowl Assembly, non-witnessed
Hydrostatic test of Bowl and Head, non-witnessed

Weight, Freight, Boxing


Qty Description
1 Fire pump weight: 1125 lb / 510.29 kg
Driver weight: 1435 lb / 650.91 kg
Muffler weight: 0 lb / 0 kg
Fuel tank weight: 302 lb / 136.99 kg
Fire pump controller weight: 250 lb / 113.4 kg
Gear box weight: 345 lb / 156.49 kg
Jockey pump weight: 11 lb / 4.99 kg
Jockey pump motor weight: 23 lb / 10.43 kg
Watson McDaniel relief valve weight: 2 lb / 0.91 kg
Discharge gauge weight: 2 lb / 0.91 kg
Jockey pump controller weight: 0 lb / 0 kg
Ball drip valve weight: 2 lb / 0.91 kg
Main relief valve weight: 95 lb / 43.09 kg
Waste cone weight: 42 lb / 19.05 kg
Flow meter weight: 10 lb / 4.54 kg
Total weight: 3633 lb / 1647.9 kg

The Equipment referenced in the attached quote or proposal is specifically designed and dimensioned for, and intended only to be installed in Large
Scale Fixed Installations (LSFI) as that term is defined in RoHS (EU Directive 2011/65) as such Directive may be amended from time to time.

The Buyer by placing its order warrants and represents, and shall ensure that any customer of the Buyer to whom the Buyer resells or otherwise
assigns the Equipment warrants and represents, that (i) the Equipment will be solely and exclusively installed in combination with other equipment,
sub-systems, apparatus and/or devices which are intended to be a part of a “large scale” installation (*Examples of “large scale” installations may
include but are not limited to installations which (a) are too large to be moved in an ISO 20 foot container because the total sum of its parts as
transported is larger than 5,71m x 2,35m x 2,39m; (b) are too heavy to be moved by a 44 tonne road truck; (c) have a rated power greater than 375
kW; and/or (d) require cranes to be completely installed); (ii) the installation in which the Equipment will be utilized will be assembled, installed, and
de-installed by professionals holding the requisite knowledge, experience, and licenses necessary to undertake and complete the work related to the
installation; and (iii) the overall system in which the Equipment will be included will be used permanently in a pre-defined and dedicated location.

The Buyer further acknowledges and agrees that Pentair is relying on the above warranties and representations by Buyer as a material inducement
to sell the Equipment to Buyer, and Buyer will defend, indemnify, and hold Pentair harmless from and against any and all claims, losses, fines,
decrees, penalties, and/or causes of action arising out of or related to breach of the above warranties and representations, including but not limited to
those brought by any governmental or quasi-governmental authority.

: +52 667 759 0470 · :

Page 6 of 31
Customer Pump Performance Curve
Encompass 2.0 - 20.2.4
Project name : Sal

36
Power - kW

27 Power

18

200
Minimum Continuous Stable Flow
180
Max allowable flow
Preferred operating region
160 179 mm
60 67 73
140
77 79 80
171 mm
80
Head - psi

120
79 77
100 152 mm
73

80 67

60

40

20

0
-m
N

H
P
S

8
NPSH3
0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190
4

Flow - m3/h

Item number : 001 Size : 10M


Service : Stages :6
Quantity :1 Driver type : Engine
G&G
Quote number :INDSUTRIAL Frequency : 60
Date last saved : 03 Aug 2020 5:42 PM Speed : 1770 rpm
Flow, rated : 56.78 m3/h Based on curve number : 10_TURB_2260_1800_SS Rev 180719
Differential head/pressure, rated @ Bowl : 128.6 psi Efficiency : 65.52 %
Suction lift : 2.57 m Max Shutoff per NFPA : 180.1 psi
Lift strategy : Min req'd water level Power driver, minimum : 32.81 kW
Head/Pressure @ discharge flange : 125.0 psi
150% of rated flow : 85.17 m3/h
65% of rated head @ bowl : 83.62 psi

Page 7 of 31
Encompass 2.0 - 20.2.4

General Arrangement

GEAR

MODEL AG AH AI RATIO

G60 678 291 457 1:1

BOWL ASSEMBLY, COLUMN & SHAFTING


NUMBER NOMINAL
OAL OF COLUMN V W Y Z
STAGES DIA
118.11023628 6 152 1,460 152 254 533

DISCHARGE HEAD & BASEPLATE


DISCH
"BD" SIZE A B C F G H N S T U
SIZ
E
419 6 SDC 584 289 254 38.10 25.40 22.22 26.99 610 533 435

ENGINE
MODEL AA AB AF AL AN CA CB CC CD CE CS HD HP
JU4H-UFH0 813 381 127 102 25.40 1,016 NA 762 907 57.40 371 514 1,143
Notes:
1. FLANGE RATINGS ARE EITHER 125# OR 250# AS DESIGNATED IN THE CERTIFICATION BLOCK BELOW FOR EACH ORDER SUBMITTAL.
2. NOT FOR CONSTRUCTION, INSTALLATION, OR APPLICATION PURPOSED UNLESS CERTIFIED.
3. DIMENSIONS SHOWN MAY VARY DUE TO NORMAL MANUFACTURING TOLERANCES.
4. BASES ARE DESIGNED TO HAVE FULL CONTACT WITH GROUT OR A SOLE PLATE GROUTED IN PLACE.
5. CD, CE & SHAFTING LENGTH DIMENSIONED TO FACE OF DRIVE FLANGE.

Pump Information Quote Information


Bowl Size: 10M Stages: 6 Listing: UL&FM Customer G&G INDUSTRIAL
Flow: 56.78 m3/h Pressure: 125.0 psi Max Lift: 2.57 m Quote Number 1210532
Engine Model: JU4H-UFH0 Power: 54.44 kW Flange Rating: 125 Lb. Job Name Sal
Engine mfg.: Clarke Gear mfg. : Randolph RPM: 1770 rpm - -
- - - - Disch Size: 6 SDC Item Number 001
Certified for: - Certified by: - Quote Date 08/03/2020
Page 8 of 31
Section 914 Page 101
Date April 1, 2006

Application & Reference Data


Typical Specifications

Section 914
Vertical Turbine Fire Pump

Page 9 of 31
Section 914 Page 102 Typical Specifications
Date April 1, 2006 Vertical Turbine
Fire Pump
Motor Driven

VERTICAL
Contractor shall furnish and install a quantity of _____ Fairbanks Nijhuis ________ stage, ________ Model (Underwriters Laboratories Listed) (Underwriters
Laboratories of Canada Listed) (Factory Mutual Approved) water lubricated vertical turbine fire pump(s). Each unit shall include a bowl assembly, strainer, column

and shaft, surface discharge head, vertical hollow shaft electrical motor, automatic air release valve, discharge pressure gauge, and automatic motor controller.

CONDITIONS OF SERVICE
The pump(s) shall be rated for _____ GPM at ______ PSI at the discharge head centerline. The maximum lift below (distance from the discharge head centerline
to the minimum low water level) will not exceed ______ feet. The distance from the top of the pump mounting pad to the bottom of the sump or reservoir shall be
____ feet. The unit(s) will be installed at _____ feet elevation above sea level with a maximum ambient temperature of _____ degrees F.

PUMP CONSTRUCTION
DISCHARGE HEAD
The discharge head shall be Class 30 cast iron with a separate cast iron foundation plate, and shall be furnished with a grease lubricated packing box and ANSI
(125 lb.) (250 lb.) standard discharge flange. To prevent damage to the shaft when installing or removing the motor, a separate motor shaft shall be furnished
and shall be connected to the headshaft at a point above the packing box with a threaded coupling. The headshaft shall be furnished with a stainless steel
sleeve where it passes through the packing box. The discharge head shall be provided with a ______” NPT tap for packing box drainage. The discharge head
shall be hydrostatically tested 1-1/2 times the maximum working pressure but in no case less than 250 PSI

COLUMN PIPE
Pump column pipe shall be furnished in sections not exceeding 10 feet in length with straight threads and sleeve
type couplings. Pipe weights shall be not less than specified in NFPA #20.

LINESHAFT
Open, water lubricated construction shall be used where the distance from the discharge head to the static water level does not exceed 50 feet.
Lineshaft shall be furnished in sections not exceeding 10 feet in length. Lineshaft shall be SAE 1045 steel of adequate size to transmit the horsepower
and thrust required and shall have renewable shaft sleeves. The lineshaft shall run in neoprene bearings housed in bronze bearing retainers.

BOWL ASSEMBLY
The pump bowls shall be Class 30 cast iron with bronze bowl wearing rings, bronze enclosed impellers and steel impeller lock collets. The pump shaft
shall be 416 stainless steel supported by bronze bowl bearings. The bowl assembly shall be hydrostatically tested to 1-1/2 times the maximum working
pressure but in no case less than 250 PSI. The bowl assembly shall be performance tested and certified performance curves supplied.

STRAINER
A bronze basket strainer with a free area of at least 4 times the suction area and with openings to restrict the passage of a 1/2” sphere shall also be supplied.

ELECTRIC MOTOR
Electric motor(s) shall be of the
weather protected Type 1, vertical hollow shaft design with non-reverse ratchet and 1.15 service factor, _____ RMP, and wound
for ____ phase, _____ hertz, _____ volts. Motor(s) shall be of the (across-the-line) (part-winding) (wye-delta) (primary resistor) (auto-transformer) (soft start)
type starting and sizing so as not to exceed the permissible loading limits of NFPA #20 (or Factory Mutual Loss Prevention Data Sheet 3-
7N) at any point on the pump performance curve. Motor(s) shall be provided with thrust bearings having an average life of 5 years
continuous operation and capable of sustaining the maximum pump downthrust. Maximum motor horsepower shall not exceed ______ HP.

Page 10 of 31
Section 914 Page 103
Typical Specifications
Date April 1, 2006
Vertical Turbine
Fire Pump
Motor Driven

CONTROLLER
The electric motor controller shall be arranged to start the fire pump motor automatically on loss of system pressure with (automatic stop) (manual stop). (For
sprinkler or standpipe systems where an automatically controlled pumping unit constitutes the sole supply, the controller shall be wired for manual shutdown. Manual
shutdown shall also be provided where required by the authority jurisdiction.) It shall be supplied with a circuit breaker rated not less than __________ AIC at

_____ phase, ______ hertz, ______ volts.


The magnetic starting contactor shall be of the (choose one:):

1.Across-the-line type. 5. Wye-Delta open transition reduced voltage type.

2.Primary resistor reduced voltage type. 6. Wye-Delta closed transition reduced voltage type.

3.Primary reactor reduced voltage type. 7. Auto transformer reduced voltage type.

4.Part winding reduced voltage start type. 8. Solid state soft start reduced voltage type.

ACCESSORIES
Furnish each pump with the following fittings or accessories:
1.3-1/2” dial discharge pressure gauge.
2.Minimum 1-1/2” automatic air and vacuum release valve.
3.Pressure recorder as required by Factory Mutual and NFPA #20, common to all pumps.
4.Hose valve manifold with a set of 2-1/2” hose valves, caps and chains, or flowmeter common to all pumps.
5.Water level testing device common to all pumps.

STANDARDS
All equipment furnished and the complete installation shall be in accordance with NFPA #20 and/or (UL448) (ULC 448) (Factory Mutual Approved Standard #1312).

Pump(s) and controller(s) shall bear the (UL) (ULC) (FM) mark.

Page 11 of 31
Section 914 Page 104 Typical Specifications
Date April 1, 2006 Vertical Turbine
Fire Pump
Engine Driven

GENERAL
Contractor shall furnish and install a quantity of _____ Fairbanks Nijhuis ________ stage, ________ Model (Underwriters Laboratories Listed) (Underwriters
Laboratories of Canada Listed) (Factory Mutual Approved) water lubricated vertical turbine fire pump(s). Each unit shall include a bowl
assembly, strainer, column and shaft, surface discharge head, vertical hollow shaft right angle gear, gear to engine flexible shaft with guard,
automatic air release valve, discharge pressure gauge, and diesel engine with fuel and starting systems and automatic engine controller.

CONDITIONS OF SERVICE
The pump(s) shall be rated for _____ GPM at ______ PSI at the discharge head centerline. The maximum lift below (distance from the discharge head centerline
to the minimum low water level) will not exceed ______ feet. The distance from the top of the pump mounting pad to the bottom of the sump or reservoir shall be
____ feet. The unit(s) will be installed at _____ feet elevation above sea level with a maximum ambient temperature of _____ degrees F.

PUMP CONSTRUCTION
DISCHARGE HEAD
The discharge head shall be Class 30 cast iron with a separate cast iron foundation plate, and shall be furnished with a grease lubricated packing box and ANSI
(125 lb.) (250 lb.) standard discharge flange. To prevent damage to the shaft when installing or removing the motor, a separate motor shaft shall be furnished
and shall be connected to the headshaft at a point above the packing box with a threaded coupling. The headshaft shall be furnished with a stainless steel
sleeve where it passes through the packing box. The discharge head shall be provided with a ______” NPT tap for packing box drainage. The discharge head
shall be hydrostatically tested 1-1/2 times the maximum working pressure but in no case less than 250 PSI

COLUMN PIPE
Pump column pipe shall be furnished in sections not exceeding 10 feet in length with straight threads and sleeve
type couplings. Pipe weights shall be not less than specified in NFPA #20.

LINESHAFT
Open, water lubricated construction shall be used where the distance from the discharge head to the static water level does not exceed 50 feet.
Lineshaft shall be furnished in sections not exceeding 10 feet in length. Lineshaft shall be SAE 1045 steel of adequate size to transmit the horsepower
and thrust required and shall have renewable shaft sleeves. The lineshaft shall run in neoprene bearings housed in bronze bearing retainers.

BOWL ASSEMBLY
The pump bowls shall be Class 30 cast iron with bronze bowl wearing rings, bronze enclosed impellers and steel impeller lock collets. The pump shaft
shall be 416 stainless steel supported by bronze bowl bearings. The bowl assembly shall be hydrostatically tested to 1-1/2 times the maximum working
pressure but in no case less than 250 PSI. The bowl assembly shall be performance tested and certified performance curves supplied.

STRAINER
A bronze basket strainer with a free area of at least 4 times the suction area and with openings to restrict the passage of a 1/2” sphere shall also be supplied.

GEAR
A vertical hollow shaft right angle gear with a non-reverse ratchet shall be furnished to match the mounting dimensions of the discharge head.
The gear shall have adequate thrust and horsepower ratings to transmit the maximum thrust and horsepower required by the pump.

Page 12 of 31
Typical Specifications Section 914 Page 105
Date April 1, 2006
Vertical Turbine
Fire Pump
Engine Driven

ENGINE
Diesel engine(s) shall be equal to ______Model ______rated ______HP at _____ RPM at 300 feet above sea level and 77 degrees F and shall be
(Underwriters Laboratories Listed) (Factory Mutual Approved). Each engine shall be provided with electric starting equipment and a charging alternator.
The factory supplied heat exchanger piping loop complete with required strainers, a pressure gauge, a pressure reducing valve, and a bypass line shall
be installed between the pump discharge head and the engine heat exchanger by the installing contractor. Each engine shall be furnished with lead-acid
starting batteries, battery rack and cables, a flexible exhaust connector and industrial type silencer. Furnish each engine with a jacket water heater.

FLEXIBLE SHAFT
A flexible shaft, with engine and gear flanges, shall be furnished to connect the engine to the gear. The shaft shall be adequately sized to transmit the

maximum pump brake horsepower at the engine speed with a minimum bearing life of 2500 hours. The shaft shall be protected by a shaft guard.

CONTROLLER
The diesel engine controller shall be arranged to start the fire pump motor automatically on loss of system pressure with (automatic stop) (manual stop). (For sprin-
kler or standpipe systems where an automatically controlled pumping unit constitutes the sole supply, the controller shall be wired for manual shutdown. Manual
shutdown shall also be provided where required by the authority jurisdiction.) An automatic weekly test timer shall also be standard. The controller shall be furnished
with a built-in battery charger capable of restoring the batteries from a fully discharged condition to a fully charged condition within twenty-four (24) hours.

FUEL SYSTEM
Furnish an above ground fuel tank with a capacity equal to one gallon per horsepower plus 5% volume for expansion
and 5% volume for sump. Furnish the tank with an indicating fuel level gauge. Provide flexible fuel line connectors at
the engine and fuel line connections at the fuel tank. (Fuel lines to be provided by the installing contractor.)

ACCESSORIES
Furnish each pump with the following fittings or accessories:
1.3-1/2” dial discharge pressure gauge.
2.Minimum 1-1/2” automatic air and vacuum release valve.
3.Main relief valve with closed waste cone.
4.Discharge tee with relief valve elbow.
5.Pressure recorder as required by Factory Mutual and NFPA #20, common to all pumps.
6.Hose valve manifold with a set of 2-1/2” hose valves, caps and chains, or flowmeter common to all pumps.
7.Water level testing device common to all pumps.

STANDARDS
All equipment furnished and the complete installation shall be in accordance with NFPA #20 and/or (UL448) (ULC 448) (Factory Mutual Approved Standard #1312).

Pump(s) and controller(s) shall bear the (UL) (ULC) (FM) mark.

Page 13 of 31
Section 914 Page 106 Technical Data
Date April 1, 2006 Vertical Turbine
Fire Pump

250 - 300 GPM 10M


NUMBER OF STAGES 4 5 6 7 8 9 10 11 12 13 14 15
Bowl O.D. (in.) 9.63 9.63 9.63 9.63 9.63 9.63 9.63 9.63 9.63 9.63 9.63 9.63
Bowl Kt/(lbs./Foot) 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8
Bowl Ka/(lbs.) 63.2 79 94.8 110.6 126.4 142.2 158 173.8 189.6 205.4 221.2 237
Bowl Shaft Diameter 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16
Lineshaft Diameter (1)` 1 1 1 1 1 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4
Lineshaft Ks/Foot 2.8 2.8 2.8 2.8 2.8 4.2 4.2 4.2 4.2 4.2 4.2 4.2
"SDC" Discharge Head Size (2) 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 N/A N/A N/A N/A N/A N/A N/A N/A
"LAD" Discharge Head Size (2) 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6 16-1/2x6
Column O.D. (in.) 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8
Column Weight/Foot (lbs.) 18.97 18.97 18.97 18.97 18.97 18.97 18.97 18.97 18.97 18.97 18.97 18.97
Column Wall Thickness (in.) 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28

400 GPM 10M


NUMBER OF STAGES 4 5 6 7 8 9 10
Bowl O.D. (in.) 9.63 9.63 9.63 9.63 9.63 9.63 9.63
Bowl Kt/(lbs./Foot) 3.8 3.8 3.8 3.8 3.8 3.8 3.8
Bowl Ka/(lbs.) 63.2 79 94.8 110.6 126.4 142.2 158
Bowl Shaft Diameter 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16
Lineshaft Diameter (1)` 1 1 1 1 1 1-1/4 1-1/4
Lineshaft Ks/Foot 2.8 2.8 2.8 2.8 2.8 4.2 4.2
"SDC" Discharge Head Size (2) 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 N/A N/A N/A
"LAD" Discharge Head Size (2) 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6
Column O.D. (in.) 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8
Column Weight/Foot (lbs.) 18.97 18.97 18.97 18.97 18.97 18.97 18.97
Column Wall Thickness (in.) 0.28 0.28 0.28 0.28 0.28 0.28 0.28

500 GPM 11M


NUMBER OF STAGES 4 5 6 7 8 9 10 11 12
Bowl O.D. (in.) 10.86 10.86 10.86 10.86 10.86 10.86 10.86 10.86 10.86
Bowl Kt/(lbs./Foot) 5.02 5.02 5.02 5.02 5.02 5.02 5.02 5.02 5.02
Bowl Ka/(lbs.) 88 110 132 154 176 198 220 242 264
Bowl Shaft Diameter 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16
Lineshaft Diameter (1)` 1-1/4 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2
Lineshaft Ks/Foot 4.2 4.2 4.2 4.2 6.0 6.0 6.0 6.0 6.0
"SDC" Discharge Head Size (2) (3) 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 N/A N/A N/A N/A
"LAD" Discharge Head Size (2) 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6
Column O.D. (in.) 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8 6-5/8
Column Weight/Foot (lbs.) 18.97 18.97 18.97 18.97 18.97 18.97 18.97 18.97 18.97
Column Wall Thickness (in.) 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28

1. For setting using more than 50 feet of column and lineshafting, consult the Factory to ensure adequate lineshaft size.
2. Discharge heads are equipped with dual registers to accommodate drivers from 10" through 24" BD.
3. U.L. Listed Only.
Page 14 of 31
914
Section Page 107
Technical Data
Date April 1, 2006
Vertical Turbine
Fire Pump

750 GPM 12M


NUMBER OF STAGES 3 4 5 6 7 8 9 10
Bowl O.D. (in.) 12.26 12.26 12.26 12.26 12.26 12.26 12.26 12.26
Bowl Kt/(lbs./Foot) 6.33 6.33 6.33 6.33 6.33 6.33 6.33 6.33
Bowl Ka/(lbs.) 88.5 118 147.5 177 206.5 236 265.5 295
Bowl Shaft Diameter 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16
Lineshaft Diameter (1)` 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-11/16 1-11/16 1-11/16
Lineshaft Ks/Foot 4.2 4.2 6.0 6.0 6.0 8.1 8.1 8.1
"LAD" Discharge Head Size (2) 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6
Column O.D. (in.) 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8
Column Weight/Foot (lbs.) 24.7 24.7 24.7 24.7 24.7 24.7 24.7 24.7
Column Wall Thickness (in.) .277 .277 .277 .277 .277 .277 .277 .277

750 GPM 14M


NUMBER OF STAGES 3 4 5 6 7 8 9
Bowl O.D. (in.) 14 14 14 14 14 14 14
Bowl Kt/(lbs./Foot) 8.41 8.41 8.41 8.41 8.41 8.41 8.41
Bowl Ka/(lbs.) 112.5 150 187.5 225 262.5 300 337.5
Bowl Shaft Diameter 1-15/16 1-15/16 1-15/16 1-15/16 1-15/16 1-15/16 1-15/16
Lineshaft Diameter (1)` 1-1/4 1-1/2 1-1/2 1-11/16 1-11/16 1-11/16 1-15/16
Lineshaft Ks/Foot 4.2 6.0 6.0 8.1 8.1 8.1 10.6
"SDC" Discharge Head Size (2) 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 N/A N/A N/A
"LAD" Discharge Head Size (2) 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8
Column O.D. (in.) 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8
Column Weight/Foot (lbs.) 24.7 24.7 24.7 24.7 24.7 24.7 24.7
Column Wall Thickness (in.) .277 .277 .277 .277 .277 .277 .277

1.For setting using more than 50 feet of column and lineshafting, consult the Factory to ensure adequate lineshaft size.
2. Discharge heads are equipped with dual registers to accommodate drivers from 10" through 24" BD.
3. U.L. Listed Only. (750 12M)

Page 15 of 31
Section 914 Page 107.1 Technical Data
Date April 1, 2006 Vertical Turbine
Fire Pump

1000 GPM 12M


NUMBER OF STAGES 3 4 5 6 7 8 9
Bowl O.D. (in.) 12.26 12.26 12.26 12.26 12.26 12.26 12.26
Bowl Kt/(lbs./Foot) 6.33 6.33 6.33 6.33 6.33 6.33 6.33
Bowl Ka/(lbs.) 88.5 118 147.5 177 206.5 236 265.5
Bowl Shaft Diameter 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16
Lineshaft Diameter (1)` 1-1/4 1-1/2 1-1/2 1-1/2 1-11/16 1-11/16 1-11/16
Lineshaft Ks/Foot 4.2 6.0 6.0 6.0 8.1 8.1 8.1
"LAD" Discharge Head Size (2) 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6 16-1/2 x6
Column O.D. (in.) 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8
Column Weight/Foot (lbs.) 24.7 24.7 24.7 24.7 24.7 24.7 24.7
Column Wall Thickness (in.) .277 .277 .277 .277 .277 .277 .277

1000 GPM 14M


NUMBER OF STAGES 3 4 5 6 7 8 9
Bowl O.D. (in.) 14 14 14 14 14 14 14
Bowl Kt/(lbs./Foot) 8.41 8.41 8.41 8.41 8.41 8.41 8.41
Bowl Ka/(lbs.) 112.5 150 187.5 225 262.5 300 337.5
Bowl Shaft Diameter 1-15/16 1-15/16 1-15/16 1-15/16 1-15/16 1-15/16 1-15/16
Lineshaft Diameter (1)` 1-1/4 1-1/2 1-1/2 1-11/16 1-11/16 1-11/16 1-15/16
Lineshaft Ks/Foot 4.2 6.0 6.0 8.1 8.1 8.1 10.6
"SDC" Discharge Head Size (2) 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 N/A N/A N/A
"LAD" Discharge Head Size (2) 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8
Column O.D. (in.) 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8
Column Weight/Foot (lbs.) 24.7 24.7 24.7 24.7 24.7 24.7 24.7
Column Wall Thickness (in.) .277 .277 .277 .277 .277 .277 .277

1. For setting using more than 50 feet of column and lineshafting, consult the Factory to ensure adequate lineshaft size.
2. Discharge heads are equipped with dual registers to accommodate drivers from 10" through 24" BD.
3. U.L. Listed Only. (1000 GPM 12 M)

Page 16 of 31
Section 914 Page 107.2
Date April 1, 2006

THIS PAGE LEFT INTENTIONALLY BLANK

Page 17 of 31
Section 914 Page 108 Technical Data
Date April 1, 2006 Vertical Turbine
Fire Pump

1250 GPM 13H


NUMBER OF STAGES 4 5 6 7 8 9 10
Bowl O.D. (in.) 12.9 12.9 12.9 12.9 12.9 12.9 12.9
Bowl Kt/(lbs./Foot) 12.02 12.02 12.02 12.02 12.02 12.02 12.02
Bowl Ka/(lbs.) 173.2 216.5 259.8 303.1 346.4 389.7 433
Bowl Shaft Diameter 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16
Lineshaft Diameter (1)` 1-1/2 1-1/2 1-11/16 1-11/16 1-11/16 1-15/16 1-15/16
Lineshaft Ks/Foot 6 6 8.1 8.1 8.1 10.6 10.6
"SDC" Discharge Head Size (2) 16-1/2x8 16-1/2x8 16-1/2x8 N/A N/A N/A N/A
"LAD" Discharge Head Size (2) 16-1/2x8 16-1/2x8 16-1/2x8 16-1/2x8 16-1/2x8 16-1/2x8 16-1/2x8
Column O.D. (in.) 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8
Column Weight/Foot (lbs.) 24.7 24.7 24.7 24.7 24.7 24.7 24.7
Column Wall Thickness (in.) 0.277 0.277 0.277 0.277 0.277 0.277 0.277

1500 GPM 13H


NUMBER OF STAGES 4 5 6 7 8 9 10
Bowl O.D. (in.) 12.9 12.9 12.9 12.9 12.9 12.9 12.9
Bowl Kt/(lbs./Foot) 12.02 12.02 12.02 12.02 12.02 12.02 12.02
Bowl Ka/(lbs.) 173.2 216.5 259.8 303.1 346.4 389.7 433
Bowl Shaft Diameter 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16 1-11/16
Lineshaft Diameter (1)` 1-1/2 1-1/2 1-11/16 1-11/16 1-11/16 1-15/16 1-15/16
Lineshaft Ks/Foot 6.0 6.0 8.1 8.1 8.1 10.6 10.6
"SDC" Discharge Head Size (2) 16-1/2 x8 16-1/2 x8 16-1/2 x8 N/A N/A N/A N/A
"LAD" Discharge Head Size (2) 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8 16-1/2 x8
Column O.D. (in.) 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8 8-5/8
Column Weight/Foot (lbs.) 24.7 24.7 24.7 24.7 24.7 24.7 24.7
Column Wall Thickness (in.) 0.277 0.277 0.277 0.277 0.277 0.277 0.277

1. For setting using more than 50 feet of column and lineshafting, consult the Factory to ensure adequate lineshaft size.
2. Discharge heads are equipped with dual registers to accommodate drivers from 10" through 24" BD.

Page 18 of 31
Section 914 Page 109
Technical Data
Date April 1, 2006
Vertical Turbine
Fire Pump

2000 GPM 15H


NUMBER OF STAGES 3 4 5 6
Bowl O.D. (in.) 15.0 15.0 15.0 15.0
Bowl Kt/(lbs./Foot) 14.47 14.47 14.47 14.47
Bowl Ka/(lbs.) 160.2 213.6 267 320.4
Bowl Shaft Diameter 1-15/16 1-15/16 1-15/16 1-15/16
Lineshaft Diameter (1)` 1-1/2 1-11/16 1-15/16 1-15/16
Lineshaft Ks/Foot 6.0 8.1 10.6 10.6
"SDC" Discharge Head Size (2) (3) 16-1/2 x10 16-1/2 x10 16-1/2 x10 N/A
"LAD" Discharge Head Size (2) 20x10 20x10 20x10 20x10
Column O.D. (in.) 10-3/4 10-3/4 10-3/4 10-3/4
Column Weight/Foot (lbs.) 31.2 31.2 31.2 31.2
Column Wall Thickness (in.) 0.279 0.279 0.279 0.279

2000 GPM 17M


NUMBER OF STAGES 3 4 5 6
Bowl O.D. (in.) 16.92 16.92 16.92 16.92
Bowl Kt/(lbs./Foot) 21.08 21.08 21.08 21.08
Bowl Ka/(lbs.) 195 260 325 390
Bowl Shaft Diameter 2-3/16 2-3/16 2-3/16 2-3/16
Lineshaft Diameter (1)` 1-11/16 1-15/16 1-15/16 2-3/16
Lineshaft Ks/Foot 8.1 10.6 10.6 13.6
"LAD" Discharge Head Size (2) 20x10 20x10 20x10 20x10
Column O.D. (in.) 12-3/4 12-3/4 12-3/4 12-3/4
Column Weight/Foot (lbs.) 43.77 43.77 43.77 43.77
Column Wall Thickness (in.) 0.330 0.330 0.330 0.330

2500 GPM 15H 3000 GPM 17H


NUMBER OF STAGES 3 4 5 NUMBER OF STAGES 3
Bowl O.D. (in.) 15.0 15.0 15.00 BOWL O.D. (IN.) 16.92
Bowl Kt/(lbs./Foot) 14.47 14.47 14.47 BOWL KT (LBS./ FOOT) 18.54
Bowl Ka/(lbs.) 160.2 213.6 267 BOWL KA (LBS.) 210.3
Bowl Shaft Diameter 1-15/16 1-15/16 1-15/16 BOWL SHAFT DIAMETER 2 3/16
Lineshaft Diameter (1)` 1-11/16 1-15/16 1-15/16 LINESHAFT DIAMETER (1) 2 3/16
Lineshaft Ks/Foot 8.1 10.6 10.6 LINESHAFT KS / FOOT 13.6
"SDC" Discharge Head Size (2) (3) 16-1/2 x10 16-1/2 x10 16-1/2 x10 "LS" DISCHARGE HEAD SIZE 24-1/2X12
"LAD" Discharge Head Size (2) 20x10 20x10 20x10 COLUMN O.D. (IN.) 12 3/4
Column O.D. (in.) 10-3/4 10-3/4 10-3/4 COLUMN WEIGHT / FOOT (LBS.) 43.77
Column Weight/Foot (lbs.) 31.2 31.2 31.2 COLUMN WALL THICKNESS (IN.) 0.33
Column Wall Thickness (in.) 0.279 0.279 0.279

1. For setting using more than 50 feet of column and lineshafting, consult the Factory to ensure adequate lineshaft size.
2. Discharge heads are equipped with dual registers to accommodate drivers from 10" through 24" BD.
3. U.L. Listed Only. (2000 GPM 15 H, 2500 GPM 15 H)

Page 19 of 31
Section 914 Page 110 Technical Data
Date April 1, 2006 Vertical Turbine
Fire Pump

3000 GPM 19A 3500 GPM 19A


NUMBER OF STAGES 2 3 NUMBER OF STAGES 2 3
Bowl O.D. (in.) 18-3/4 18-3/4 Bowl O.D. (in.) 18-3/4 18-3/4
Bowl Kt/(lbs./Foot) 30 30 Bowl Kt/(lbs./Foot) 30 30
Bowl Ka/(lbs.) 180 260 Bowl Ka/(lbs.) 180 260
Bowl Shaft Diameter 2-3/16 2-3/16 Bowl Shaft Diameter 2-3/16 2-3/16
Lineshaft Diameter (1)` 1-15/16 2-3/16 Lineshaft Diameter (1)` 1-15/16 2-3/16
Lineshaft Ks/Foot 10.6 13.6 Lineshaft Ks/Foot 10.6 13.6
"SDH" Discharge Head Size 24-1/2x12 24-1/2x12 "SDH" Discharge Head Size 24-1/2x12 24-1/2x12
Column O.D. (in.) 12-3/4 12-3/4 Column O.D. (in.) 12-3/4 12-3/4
Column Weight/Foot (lbs.) 43.77 43.77 Column Weight/Foot (lbs.) 43.77 43.77
Column Wall Thickness (in.) 0.33 0.33 Column Wall Thickness (in.) 0.33 0.33

4000 GPM 19B 4500 GPM 19B


NUMBER OF STAGES 2 3 NUMBER OF STAGES 2 3
Bowl O.D. (in.) 18-3/4 18-3/4 Bowl O.D. (in.) 18-3/4 18-3/4
Bowl Kt/(lbs./Foot) 30 30 Bowl Kt/(lbs./Foot) 30 30
Bowl Ka/(lbs.) 180 260 Bowl Ka/(lbs.) 180 260
Bowl Shaft Diameter 2-3/16 2-3/16 Bowl Shaft Diameter 2-3/16 2-3/16
Lineshaft Diameter (1)` 1-15/16 2-3/16 Lineshaft Diameter (1)` 1-15/16 2-3/16
Lineshaft Ks/Foot 10.6 13.6 Lineshaft Ks/Foot 10.6 13.6
"SDH" Discharge Head Size (2) (3) 24-1/2x12 24-1/2x12 "SDH" Discharge Head Size (2) (3) 24-1/2x12 24-1/2x12
Column O.D. (in.) 12-3/4 12-3/4 Column O.D. (in.) 12-3/4 12-3/4
Column Weight/Foot (lbs.) 43.77 43.77 Column Weight/Foot (lbs.) 43.77 43.77
Column Wall Thickness (in.) 0.33 0.33 Column Wall Thickness (in.) 0.33 0.33

1. For setting using more than 50 feet of column and lineshafting, consult the Factory to ensure adequate lineshaft size.
2. Discharge heads are equipped with dual registers to accommodate drivers from 16-1/2" through 24" BD.

3. U.L. Listed Only.

Page 20 of 31
Construction Features Section 914 Page 111
Date April 1, 2006
Vertical Turbine
Fire Pump

Type Vertical Multi-Stage Turbine


Rotation Counter-clockwise, Viewed from Driven End
Bowls Diffuser Type, Suction Case and Intermediate Bowls with Wearing Rings,
Suction Threaded, for Strainer or Flared for Clip On Strainer
Impellers Enclosed Type, Single Suction
Bearings, Bowl Sleeve Type, Water Lubricated
Shaft, Bowl Water Lubricated
Column Pipe Threaded
Coupling, Column Pipe Threaded, Sleeve Type
Shaft, Line Open, Water Lubricated (1)
Coupling, Lineshaft Thread or Flanged connection, Surface Type (Refer to Factory)
Sleeve, Lineshaft Straight
Bearing, Lineshaft Straight, Water Lubricated (1)
Retainer, Bearing One Piece Cast, Inter-Locked by Column Joints (For open water-lubricated) (1)
Foundation Plate Suitable for Grouting, with Discharge Head Mounting Surface
Discharge Head Flanged Connection, Surface Type
Stuffing Box Packed, with Bushing and Seal Tap
Gland One Piece
Auxiliary Connections, Heat Exchanger and Packing Box Drain
Discharge Head
Coupling, Driver Gib Key with Locknut
Strainer Threaded, Basket or Cornucopia; Clip-On Basket
(1)Oil lubricated when static water level is 50 to 200 feet below datum. Water
level datum greater than 200 feet is not approved for fire pump service.

Page 21 of 31
Section 914 Page 112 Assembly Drawing
Date April 1, 2006 Vertical Turbine
Fire Pump

1
10M, 11M, 12M, 13H, & 15H
22 SDC Discharge Head – Water Lubrication Only
7

6 ITEM DESCRIPTION MATERIAL


9 1 Adjusting Nut Steel
15
6 Water Slinger Neoprene
7 Discharge Head Cast Iron
8
8 Capscrew, Packing Box Steel Gr. 2
17
9 Gland Half Bronze
11
11 Gasket, Packing Box Tag Board
17A
12 12 Pre Lube Plug (2) Cast Iron
13 13 Sleeve, Top Shaft Stainless Steel
14
14 Foundation Plate Cast Iron
15 Packing Syn. Graphite Impreg.
19 17 Packing Box Cast Iron
21
17A Bushing, Packing Box Bronze
31 19 Top Shaft Steel
28 21 Column Pipe, Top Steel
24
25 22 Coupling, Lineshaft Steel
26 23 Lineshaft Steel
29 24 Coupling, Column Steel
23
31 25 Bearing Retainer Bronze
30 26 Bearing Neoprene
54A 28 Column Pipe, Intermediate Steel
29 Sleeve, Intermediate Shaft Stainless Steel
30 Column Pipe, Bottom Steel
31 Coupling, Pump Shaft Steel
32 Pump Shaft Stainless Steel
34
34 Bearing, Top Bowl Bronze
55
35 Bearing, Intermediate Bowl Bronze
98
36 Bowl, Intermediate Cast Iron
35
38 Impeller Bronze
36 39 Lock Collet, Impeller Steel
39 40 Bell, Suction Cast Iron
38 41 Bearing, Suction Bell Bronze
40 42 Strainer Bronze
32 42A Clip, Strainer Bronze
88
54A Flange, Adapter Cast Iron
55 Bowl, Top Cast Iron
42A
58 Sand Collar Steel
58
59 Plug, Suction Bell Cast Iron
41
88 Set Screw, Sand Collar Steel
59 98 Bowl, Wear Ring Bronze
42

Page 22 of 31
Sectional Drawing Section 914 Page 113
Date April 1, 2006
Vertical Turbine
Fire Pump

10M, 11M, 12M, 13H, & 15H


LAD Discharge Head – Water Lubrication Only
1
22
ITEM DESCRIPTION MATERIAL
7
1 Adjusting Nut Steel
6 6 Water Slinger Neoprene
9 7 Discharge Head Cast Iron
15 8 Capscrew, Packing Box Steel Gr. 2
8 9 Gland Half Bronze
17 11 Gasket, Packing Box Tag Board
11 12 Pre Lube Plug (2) Cast Iron
17 A 13 Sleeve, Top Shaft Stainless Steel
13 14 Foundation Plate Cast Iron
12
16 15 Packing Syn. Graphite Impreg.
14 16 Gasket, Top Flange Tag Board
18
17 Packing Box Cast Iron
19
21 17A Bushing, Packing Box Bronze
18 Flange, Top Column Cast Iron
31
19 Top Shaft Steel
28
24 21 Column Pipe, Top Steel
25 22 Coupling, Lineshaft Steel
26
29
23 Lineshaft Steel
23 24 Coupling, Column Steel
31 25 Bearing Retainer Bronze
30
5 4A 26 Bearing Neoprene
28 Column Pipe, Intermediate Steel
29 Sleeve, Intermediate Shaft Stainless Steel
30 Column Pipe, Bottom Steel
31 Coupling, Pump Shaft Steel
34 32 Pump Shaft Stainless Steel
55 34 Bearing, Top Bowl Bronze
98 35 Bearing, Intermediate Bowl Bronze
35 36 Bowl, Intermediate Cast Iron
38 Impeller Bronze
36
39 Lock Collet, Impeller Steel
39
40 Bell, Suction Cast Iron
38
41 Bearing, Suction Bell Bronze
40
42 Strainer Bronze
32 42A Clip, Strainer Bronze
88 54A Flange, Adapter Cast Iron
4 2A 55 Bowl, Top Cast Iron
58 58 Sand Collar Steel
41 59 Plug, Suction Bell Cast Iron
59
88 Set Screw, Sand Collar Steel
98 Bowl, Wear Ring Bronze
42

Page 23 of 31
Section 914 Page 114
Date April 1, 2006

THIS PAGE LEFT INTENTIONALLY BLANK

Page 24 of 31
Assembly Drawing Section 914 Page 115
Date April 1, 2006
Vertical Turbine
Fire Pump

1
19A & 19B
22
SDH Discharge Head – Water Lubrication Only
7
6
ITEM DESCRIPTION MATERIAL
8 1 Adjusting Nut Bronze
9 6 Water Slinger Neoprene
11 7 Discharge Head Cast Iron
15 8 Capscrew, Packing Box Steel Gr. 2
9 Gland Half Bronze
17 11 Gasket, Packing Box Tag Board
12
17A
12 Pre Lube Plug Cast Iron
16 14 Foundation Plate Cast Iron
14 15 Packing Acrylic
16 Gasket, Top Flange Tag Board
18
19 17 Packing Box Cast Iron
21 17A Bushing, Packing Box Bronze
18 Flange, Top Column Cast Iron
31
28 19 Top Shaft Stainless Steel
24 21 Column Pipe, Top Steel
26
22 Coupling, Lineshaft Steel
29
23 23 Lineshaft Steel
24 Coupling, Combination Cast Iron
31
26 Bearing Neoprene
30
28 Column Pipe, Intermediate Steel
29 Sleeve, Intermediate Shaft Stainless Steel
5 4A
30 Column Pipe, Bottom Steel
31 Coupling, Pump Shaft Steel
34 32 Pump Shaft Stainless Steel
55 34 Bearing, Top Bowl Bronze
98
35 Bearing, Intermediate Bowl Bronze
36 Bowl, Intermediate Cast Iron
35
38 Impeller Bronze
36
39 Gib Key, Impeller Stainless Steel
39 40 Bell, Suction Cast Iron
38 41 Bearing, Suction Bell Bronze
40 42 Strainer Bronze
32 42A Machine Screw, Strainer Stainless Steel
54A Flange, Adapter Cast Iron
42A 55 Bowl, Top Cast Iron
58 Sand Collar Rubber
58
59 Plug, Suction Bell Cast Iron
41
98 Bowl, Wear Ring Bronze
59
42

Page 25 of 31
Section 914 Page 116 Material Specifications
Date April 1, 2006 Vertical Turbine
Fire Pump

ITEM DESCRIPTION MATERIAL SPECIFICATION


1 Adjusting Nut Steel A108GR12L14
6 Water Slinger Neoprene Commerical
7 Discharge Head Cast Iron A48-CL30
8 Packing Capscrew Steel Grade 2 Commercial
9 Gland Half Bronze B584 AL836
11 Gasket Packing Box Tag Board Commercial
12 Pre-Lube Plug (2) Cast Iron Commercial
13 Sleeve Top Shaft Stainless Steel AISI 304
14 Floor Plate Cast Iron A48-CL30
15 Packing Syn. Graphite Impreg. Commercial
16 Gasket Top Flange Tag Board Commercial
17 Packing Box Cast Iron A48-CL30
17A Bushing Packing Box Bronze B505 AL932
18 Flange Top Column Cast Iron A48-CL30
19 Top Shaft Steel AISI 1045
21 Top Column Pipe Steel A53 or A120
22 Coupling Lineshaft Steel A108 GR12L14
23 Lineshaft Steel AISI 1045
24 Coupling Column Steel A53 or A120
25 Bearing Retainer Bronze B584 AL836
26 Bearing Neorprene Commercial
28 Column Pipe, Intermediate Steel A53 or A120
29 Sleeve Intermediate Shaft Stainless Steel AISI 304
30 Column Pipe, Bottom Steel A53 or A120
31 Coupling Pump Shaft Steel A108 GR12L14
32 Pump Shaft Stainless Steel AISI 416
34 Bearing Top Bowl Bronze B505 AL932
35 Bearing Intermediate Bowl Bronze B505 AL932
36 Bowl Intermediate Cast Iron A48-CL30
38 Impeller Bronze (3) B584 AL836
39 Lock Collet Impeller Steel A108 GR12L14
40 Bell Suction Cast Iron A48-CL30
41 Bearing Suction Bell Bronze B505 AL932
42 Strainer Brass Commercial
42A Clip, Strainer Brass Commercial
54A Flange Adapter Cast Iron A48-CL30
55 Top Bowl Cast Iron A48-CL30
58 Sand Collar Steel A108 GR12L14
59 Plug Suction Bell Cast Iron Commercial
88 Set Screw, Sand Collar Steel SAE Bolt Steel
98 Bowl Wear Ring Bronze B505 AL932
NOTE:
1. All material specifications are ASTM except where specified and are for description of chemistry only.
2. When applied with diesel engine driver, remove plug and connect to engine heat exchanger for cooling water.

3.Manufacturer’s option to furnish bronze, per B548-AL875.


Subject to change without notice.

Page 26 of 31
Typical Specifications Section 914 Page 117
Date April 1, 2006
Vertical Turbine
Fire Pump
Motor Driven

A standard length (type SL) flexible drive shaft is required to connect the fire pump engine to the right angle gear when applied with a vertical turbine pump.
To select the correct shaft size:
1.Select the engine speed in the left hand column.
2. Follow the row to the right to a horsepower value which meets or exceeds the requirements of your application. (Note: These
values include a 2.0 service factor, angle not to exceed 3 degrees, and a B-10 bearing life expectation of 2500 hours.
3.Follow the column up to select the correct shaft size.

SHAFT SIZE SERIES


48 55 61 71 81 88 91
1750 103 132 201 274 382 527 744
1900 108 138 211 286 401 553
Engine 2100 116 149 227 309 430 594 838
Speeds 2200 120 154
2300 124 158 242 330 459 633
2400 127 163
2600 135 173
2800 142 182
3000 149 191
Standard Shaft Length 24” 24” 24” 24” 36” 36” 36”

Page 27 of 31
Section 914 Page 118
Date April 1, 2006

THIS PAGE LEFT INTENTIONALLY BLANK

Page 28 of 31
PENTAIR FLOW AND FILTRATION SOLUTIONS TERMS AND CONDITIONS OF SALE

LEGAL EFFECT: The following terms and conditions are a part of this Seller’s point of shipment. Buyer will pay all transportation charges. Seller's
order. Additional or different terms of Buyer's purchase order or other form of quoted prices are based on shipment immediately upon readiness, with no
acceptance or any other form of Buyer are rejected in advance and shall not delays or storage. Work which has been suspended or stored for the Buyer's
become a part of the Order. Seller's quotation is an offer to sell under the convenience may be billed in place, and applicable storage charges shall
terms and conditions stated herein. All offers to purchase by Buyer or orders accrue. If Buyer does not furnish exact shipping instructions, Seller will
or contracts of sale resulting from such Quotations are subject to final select, in its discretion, the means of shipment. Seller will not be liable for
acceptance in writing by an Officer of the Seller. Seller's rights and remedies any loss resulting from such selection. The time of delivery is an estimate
under this Quotation and the Order are in addition to, not in substitution of, all only, and Seller may change such time if Seller does not receive the
other rights and remedies available to Seller under any applicable provision of information and approvals necessary to proceed with the manufacture of the
law, regulation or court decision. Seller may suspend its performance of the equipment. Buyer agrees to inspect all deliveries immediately. Any claim for
Order if Buyer defaults in the performance of its duties under the Order or shortages or damage must be made in writing within five (5) days after Buyer
under any other agreement between the Buyer and Seller. No employee, receives a shipment, and if not made, shall be deemed waived. Any other
agent, dealer, or distributor of Seller has any authority to change or enlarge claim by Buyer, other than claims under the WARRANTY stated below, shall
the terms of this Quotation or the Order. No change shall be valid unless it is be made within thirty (30) days after Buyer receives shipment, and if not
in writing and signed by an authorized Officer of Seller. In the event that any made shall be deemed waived. Seller is not responsible for loss or damage in
provision of these terms and conditions is deemed to be invalid or transit after having received an "In Good Order" receipt from the carrier.
unenforceable, the parties agree that such invalidity or unenforceability shall Buyer will make all claims for loss or damage in transit against the carrier.
not invalidate or render unenforceable the remainder of these terms and SHIPMENT UPON READINESS: Seller’s quoted prices are based on
conditions, and the remaining terms and conditions shall continue in full force shipment immediately upon readiness, with no delays or storage. Work that
and effect. Unless otherwise mutually agreed, the terms of any Order resulting has been suspended or stored for the Buyer’s convenience shall be billed in
from this Quotation shall be interpreted and enforced in accordance with the place, and applicable storage charges shall accrue. Promise date, shipment
laws applicable at the Seller's Home Office or primary U. S. management date or completion of manufacture date of the equipment may be changed
location. only with Seller’s written consent. If shipment is delayed at Buyer’s request,
SCOPE OF SUPPLY: As an equipment supplier, Seller will provide Buyer will make any payments due under the Order as if the equipment has
equipment per (1) Seller's quotation only, or (2) where approved in writing by been shipped on the date when it was ready for shipment. If completion of
an engineer-employee of Seller, per the technical portion of the specifications manufacture is delayed at Buyer’s request, Seller may require payment
as submitted, clarified and approved by Seller. Any terms and conditions according to percentage of completion. Buyer shall have the risk of loss with
other than those stated herein are excluded. Buyer is fully responsible for respect to equipment held for Buyer, and Seller may charge Buyer for storage.
(including payment of the cost of) installation of all equipment sold under INSURANCE: Buyer shall bear all risk of and responsibility for damage or
this order. loss to the equipment after Seller delivers the equipment to the carrier at its
ASSIGNMENT: No assignment or transfer of interests of any part of this point of shipment. Buyer agrees to provide and maintain adequate insurance
contract shall be valid without the expressed written consent of both parties. for the equipment supplied under the Order to fully protect Seller's interest
CANCELLATION: Buyer cannot cancel or alter the Order without the during the time between delivery and final payment. Loss or damage by fire
Seller's written consent. If Seller grants such consent, Buyer will reimburse or other causes during such period shall not relieve Buyer from its obligations
Seller for all of Seller's losses and expenses caused by such cancellation or under the Order. Upon request, Seller will provide Buyer with its standard
alteration, including without limitation all of Seller's additional costs caused ACORD Certificate of Insurance. Seller cannot name others as additional
by changes in design or specifications, or by product revisions, and all insureds.
consequential damages incurred by Seller as a result of such cancellation or TITLE AND LIEN RIGHTS: If Buyer defaults in its obligations under the
alteration. If Buyer cancels the Order, Buyer shall pay Seller (i) a minimum Order before the price (including any notes given therefore) of the equipment
cancellation charge of 15 percent of the purchase price; and (ii) any has been fully paid in cash, Seller may take any and all actions permitted by
damages and expenses described in this paragraph that exceed 15 percent of law to protect its interests including, where permissible, repossession of such
the purchase price. equipment. Seller agrees to indemnify Buyer from liens filed by Seller's
PRICES: Unless otherwise mutually agreed in writing, prices quoted by the workforce or subcomponent vendors. Seller's statements of conditional, partial
Seller shall be firm for a period of 60 days after quotation, or, after receipt of or complete lien waivers, consistent with payments received, will be furnished
an acceptable purchase order from the Buyer, for the duration of the contract, on request. The furnishing of such waivers shall not be a condition precedent
not to exceed one year after the Seller's receipt of the purchase order. to payment. Buyer agrees to cooperate fully with Seller in the filing of any
TERMS OF PAYMENT: Unless otherwise mutually agreed, the terms of financial statements or other documents necessary to perfect such interests and
payment shall be 100% net 30 days after shipment, paid from the Seller's liens.
invoices, contingent on approval by the Seller's Credit Manager. These terms PATENT INFRINGEMENT: Seller will defend Buyer and the user of the
apply to partial and complete shipments. Buyer agrees to make full payment equipment to the extent of any rightful claim that any equipment and parts of
under these terms without setoff. Monies held beyond these terms may be Seller's manufacture furnished under the Order infringe upon any published
subject to interest at the maximum legal rate, and may result in lien United States patent, and Seller will pay all damages and costs awarded by a
proceedings or the termination of warranties and suspension of services. If, in court of competent jurisdiction with respect to such claim. The Buyer or user
Sellers judgment, Buyer's financial condition at the time the equipment is must promptly notify Seller of any such claim, and cooperate fully with Seller
ready for shipment does not warrant the extension of credit to Buyer, Seller in the defense of such claim, or Seller will have no duty under this paragraph.
may require full payment, in cash or via letter of credit, prior to making Buyer will defend and indemnify Seller against patent infringement claims
shipment. If Seller does not receive full cash payment within fifteen (15) days relating to equipment and parts that are not manufactured by Seller to the
after it notifies Buyer that such payment is required and that the equipment is same extent as Seller agrees to defend and indemnify Buyer with respect to
ready for shipment, Seller may cancel the Order as to any unshipped item. In patent infringement claims relating to equipment and parts of Seller's
that event, Buyer will pay Seller the cancellation charges, damages and manufacture.
expenses, as described under CANCELLATION. Buyer will pay all costs and DESIGN RIGHTS: Seller sells and transfers ownership of the agreed
expenses, including reasonable attorney fees, incurred by Seller in collecting equipment and services only; not the design rights, development data, patents,
any amounts due, including interest, if any proceeding is initiated by or tooling, patterns, methods or copyrights. All such rights in data are expressly
against Buyer under any Bankruptcy, insolvency, and/or collection activities. reserved. In lieu of such rights, Seller will provide use of such form, fit and
TAXES: Seller's quoted prices do not include any present and future sales, function information as is necessary for the Buyer's approval, installation, fit-
use, occupation, license, excise, and other taxes, permits, tariffs, duties, or up and operation of the equipment.
fees with respect to the sale, delivery or use of the equipment. Any applicable WARRANTY: Seller warrants equipment (and its component parts) of its
taxes or fees will be charged at rates in effect at time of shipment. Seller is own manufacture against defects in materials and workmanship under normal
required by law to collect all applicable sales and use taxes unless an use and service for one (1) year from the date of installation or start-up, or for
appropriate exemption certificate is provided by the Buyer. Seller's quoted eighteen (18) months after the date of shipment, whichever occurs first. Seller
prices include all taxes and permits applicable throughout the manufacturing does not warrant accessories or components that are not manufactured by
process. Seller; however, to the extent possible, Seller will assign to Buyer its rights
SHIPMENT: Except as otherwise mutually agreed, domestic shipment will under the original manufacturer's warranty, without recourse to Seller. Buyer
be EXW, Seller's point of shipment, international shipments will be FCA must give Seller notice in writing of any alleged defect covered by this

Pentair Flow and Filtration Solutions Terms of Sale 06/2016 KC-585 06/2016
Page 29 of 31
PENTAIR FLOW AND FILTRATION SOLUTIONS TERMS AND CONDITIONS OF SALE

warranty (together with all identifying details, including the serial number, collateral, consequential, incidental, or special damages or for loss of profits,
the type of equipment, and the date of purchase) within thirty (30) days of the or for actual losses or for loss of production or progress of construction,
discovery of such defect during the warranty period. No claim made more regardless of the cause of such damages or losses. In any event, Seller's
than 30 days after the expiration of the warranty period shall be valid. aggregate total liability under the Order or otherwise shall not exceed the
Guarantees of performance and warranties are based on the use of original contract price.
equipment manufactured (OEM) replacement parts. Seller assumes no ACTS OF GOD: Seller shall in no event be liable for delays in delivery of
responsibility or liability if alterations, non-authorized design modifications the equipment or other failures to perform caused by fires, acts of God,
and/or non-OEM replacement parts are incorporated If requested by Seller, strikes, labor difficulties, acts of governmental or military authorities, delays
any equipment (or its component parts) must be promptly returned to Seller in transportation or procuring materials, or causes of any kind beyond Seller's
prior to any attempted repair, or sent to an authorized service station control.
designated by Seller, and Buyer shall prepay all shipping expenses. Seller COMPLIANCE WITH LAW: With respect to the purchase, sale, resale
shall not be liable for any loss or damage to goods in transit, nor will any and servicing of these goods, Buyer shall comply with all applicable laws,
warranty claim be valid unless the returned goods are received intact and trade embargos, regulations, orders and other restrictions and - without
undamaged as a result of shipment. Repaired or replaced material returned to limiting the generality of the foregoing - do the following.
customer will be shipped EXW (Domestic Shipments) or FCA (International (a) No Improper Means of Obtaining Business. Pentair and Buyer
Shipments)., Seller's factory. Seller will not give Buyer credit for parts or intend that no payments or transfers of value shall be made which
equipment returned to Seller, and will not accept delivery of any such parts or have the purpose or effect of public or commercial bribery,
equipment, unless Buyer has obtained Seller's approval in writing. acceptance of or acquiescence in extortion or kickbacks, or other
The warranty extends to repaired or replaced parts of Seller's manufacture for unlawful or improper means of obtaining business.
ninety (90) days or for the remainder of the original warranty period (b) No Bribes; Anti-Boycott Laws. Buyer will not, directly or
applicable to the equipment or parts being repaired or replaced, whichever is indirectly, pay, offer, authorize or promise any monies or anything
greater. This warranty applies to the repaired or replaced part and is not of value (such as gifts, contributions, travel, or entertainment) to
extended to the product or any other component of the product being any person or organization, including any employee of Buyer’s or
repaired. Repair parts of its own manufacture sold after the original warranty Pentair’s customers, or any Government Official (which includes
period are warranted for a period of one (1) year from shipment against any employee or official of any governmental authority,
defects in materials and workmanship under normal use and service. This government owned or controlled entity, public international
warranty applies to the replacement part only and is not extended to the organization or political party; or any candidate for political office)
product or any other component of the product being repaired. Seller may for the purpose of improperly influencing their acts or decisions.
substitute new equipment or improve part(s) of any equipment judged Buyer will take appropriate actions to ensure that any person
defective without further liability. All repairs or services performed by Seller, representing or acting under its instruction or control (“Buyer’s
which are not covered by this warranty, will be charged in accordance with Agents”) will also comply with this Section. The Buyer will not
Seller's standard prices then in effect. request customer to take any action which is prohibited or
THIS WARRANTY IS THE SOLE WARRANTY OF SELLER AND penalized under any U.S. anti-boycott law or regulation, and any
SELLER HEREBY EXPRESSLY DISCLAIMS AND BUYER WAIVES such apparent request will be deemed null and void. Nothing in
ALL OTHER WARRANTIES EXPRESSED, IMPLIED IN LAW OR this Agreement or in any such apparent request will be construed
IMPLIED IN FACT, INCLUDING ANY WARRANTIES OF to require or to constitute an agreement by customer to take action
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. which is prohibited or penalized under any U.S. anti-boycott law or
Seller's sole obligation under this warranty shall be, at its option, to repair or regulation.
replace any equipment (or its component parts) which has a defect covered by (c) No Kickbacks. No part of the payment of any amounts payable
this warranty, or to refund the purchase price of such equipment or part. under this Agreement will be distributed to Pentair, its affiliates or
Under the terms of this warranty, Seller shall not be liable for (a) customers, or any of its employees or their family members.
consequential, incidental, collateral, special or liquidated losses or damages; (d) No Conflicts. Except as disclosed in writing to Pentair (in a
(b) equipment conditions caused by normal wear and tear, abnormal questionnaire response or otherwise), Buyer represents that it does
conditions of use, accident, neglect, or misuse of said equipment; (c) the not have any reason to believe that there are any potential conflicts
expense of, and loss or damage caused by, repairs or alterations made by of interest regarding its relationship with Pentair, such as family
anyone other than the Seller; (d) damage caused by abrasive materials, members who could potentially benefit from the commercial
chemicals, scale deposits, corrosion, lightning, improper voltage, mishandling, relationship established by this Agreement; and neither Buyer, nor
or other similar conditions; (e) any loss, damage, or expense relating to or any of Buyer’s Agents, are or have any family members who are
resulting from installation, removal or reinstallation of equipment; (f) any Government Officials in a position to influence your commercial
labor costs or charges incurred in repairing or replacing defective equipment relationship with Pentair.
or parts, including the cost of reinstalling parts that are repaired or replaced by (e) Accurate Books and Records. Buyer will maintain complete and
Seller; (g) any expense of shipment of equipment or repaired or replacement accurate books and records in accordance with generally accepted
parts; or (h) any other loss, damage or expense of any nature. accounting principles in Buyer’s jurisdiction, consistently applied,
The above warranty shall not apply to any equipment which may be separately properly and accurately recording all payments made by Buyer or
covered by any alternate or special warranties. Buyer’s Agents in performance of this Agreement or related to it,
INDEMNIFICATION: Seller shall defend, indemnify and hold harmless and any commission, compensation, reimbursement, or other
Buyer from and against any and all Liabilities arising out of (1) Seller’s payment made by or on behalf of Pentair to Buyer or Buyer’s
negligence, (2) Seller’s violation of laws, rules, ordinances or regulations, (3) Agents. Buyer will maintain a system of internal accounting
Seller’s misrepresentation, misapplication, installation or maintenance of the controls reasonably designed to ensure that it maintains no off-the-
products; or (4) death of or injury to any person, or damage to any property, book accounts and that its assets are used only in accordance with
resulting from, or relating to, Seller products or services … all except to the its management directives.
extent same is alleged to have been caused by the negligence of Buyer, its (f) Notification. Buyer will notify Pentair promptly if (a) Buyer or
affiliates or their officers, directors, employees or agents. Buyer shall defend, any of Buyer’s Agents have reason to believe that a breach of this
indemnify and hold harmless Seller from and against any and all Liabilities Section has occurred or is likely to occur; or (b) if any conflicts of
arising out of Buyer’s negligence or violation of applicable laws, rules, interest arise after the signing of this Agreement, including if any
ordinances or regulations (including those described below). of Buyer’s Agents or their family members become a government
PERFORMANCE: In the absence of Certified Pump Performance Tests, official or political party candidate in a position to influence
equipment performance is not warranted or guaranteed. Performance curves Buyer’s commercial relationship with Pentair. Buyer will send all
and other information submitted to Buyer are approximate and no warranty or such notices to ethics@pentair.com or to such other location as
guarantee shall be deemed to arise as a result of such submittal. All testing Pentair may designate in writing.
shall be done in accordance with Seller's standard policy under Hydraulic (g) Compliance Certification. Buyer will, when and as may be
Institute procedures. requested by Pentair from time to time, provide to Pentair a written
LIABILITY LIMITATIONS: Under no circumstances shall the Seller have certification in form and substance satisfactory to Pentair that
any liability under the Order or otherwise for liquidated damages or for Buyer is in compliance with this Section.

Pentair Flow and Filtration Solutions Terms of Sale 06/2016 KC-585 06/2016
Page 30 of 31
PENTAIR FLOW AND FILTRATION SOLUTIONS TERMS AND CONDITIONS OF SALE

(h) No Payments for Improper Activities. Pentair will not be termination of the Agreement by Pentair, as described above, will
required under any circumstances to take any action or make any not constitute a breach of any of Pentair’s obligations under this
payments that Pentair believes, in good faith, would cause it or its Agreement, and the parties hereby waive any and all claims against
affiliated companies to be in violation of any Anti-Corruption Pentair for any loss, cost or expense related thereto.
Laws (Anti-Corruption Laws include, collectively, the United
States Foreign Corrupt Practices Act, laws under the OECD Anti- US EXPORT NOTIFICATIONS:
Bribery Convention and local anti-corruption laws). If Pentair at All sales of goods or technology are in compliance with the Export
any time believes, in good faith, that a breach of any of the Administration Regulations of the United States. Diversion contrary to U.S.
representations and warranties in this Section has occurred or may law is prohibited Seller will not participate in the Arab League Boycott
occur, Pentair may withhold any commission, compensation, against Israel. Seller therefore assumes the following to be correct – and
reimbursement, or other payment until such time as Pentair has Seller will interpret the fact of Buyer ordering from Seller to confirm Buyer
received confirmation to its reasonable satisfaction that no breach agreement to follow these same rules. The purchased goods will be used
has occurred or will occur. Pentair shall not be liable to Buyer for solely by civil end users for civil end use, and will not be used in relation to
any claim, losses, or damages whatsoever related to Pentair’s nuclear, biological, chemical, or terror-related weapons or missiles capable of
decision to withhold any commission, compensation, delivering those weapons (unless further described below). The goods will not
reimbursement, or other payment under this provision. be re-exported or sold to a third party unless further described below. Buyer
(i) Audit Rights. If Pentair at any time believes, in good faith, that shall not request or expect Anti-Israel language (as desired by the Arab
Buyer has breached the warranties, representations or agreements League Boycott against Israel) in any communications with the seller at all.
in this Section, then Pentair will have the right to audit Buyer‘s These regulations do apply, no matter whether Buyer is the ultimate
books and records related to this Agreement in order to verify consignee and end user of these products, Buyer will not be re-selling them,
Buyer’s compliance with the provisions of this Section. The audit or Buyer is a contracted distributor, intending to re-sell these goods to
will be performed by individuals selected by Pentair. However, customers within your own country who are also legal customers in the eyes
upon request by Buyer, Pentair will select in its sole discretion an of the United States, or a contracted distributor intending to re-sell these
independent third party to conduct an audit in order to certify to goods to customers in multiple countries, who are also legal customers in the
Pentair that no breach has occurred or will occur. Buyer will fully eyes of the United States.
cooperate in any audit conducted by or on behalf of Pentair. ACCEPTANCE: These terms and conditions shall constitute the entire
(j) Termination Rights. Any breach of the warranties, agreement, and all other terms and conditions of any origin are excluded.
representations or agreements in this Section will constitute Unless otherwise advised by the Buyer within ten days after Seller's
grounds for immediate termination of this Agreement and any acknowledgment of an order, Seller will proceed with processing of such
Order for cause by Pentair and no commission, compensation, order with the understanding that the Buyer is in full agreement with all
reimbursement or other payment will be due to Buyer. Buyer will provisions stated herein.
indemnify and hold Pentair harmless against any actions, legal Transaction terms: Incoterms 2010 Rules.
claims, demands, proceedings, losses, damages, costs, expenses Dates: This invoice date represents the date of cargo pickup from Seller’s
and other liabilities of whatever nature resulting from Buyer’s facility.
breach of the representations, warranties and agreements contained • On domestic sales: Transfer of both title and risk of loss shall
in the Section. occur upon pickup from seller’s site.
(k) Data Privacy Consent. Buyer consents to the collection, • On international sales: Transfer of both title and risk of loss shall
processing and international transfer of data and information occur upon entry into international waters, international airspace, or the
related to the business relationship between it and Pentair, crossing of an international border, with the sole exception of banked
including the transfer of personally identifiable data (for example transactions (L/C, DAA, DAP) in which case the transfer of title occurs upon
names, email addresses, telephone numbers) to and between exchange of documents at the bank window, and the transfer of risk of loss
Pentair and its affiliates wherever they may be located throughout occurs upon entry into international water, international airspace, or the
the world, for the purposes of allowing Pentair and its affiliates to crossing of an international border.
evaluate Buyer’s experience and qualifications and implement any Marine Insurance: The party responsible for paying the main transportation
business. Buyer has the right to: (a) request access to this data; (b) shall provide full cargo insurance coverage – defined as door-to-door, ‘A’
rectify or cancel any inaccurate or expired data; and (c) object to cover, all risk, marine, war, strike and riot – regardless of the shipping terms,
any processing that does not conform to these purposes. Buyer with the exception of CFR/CPT Incoterms, in which insurance is the buyer’s
may exercise its rights by writing to Pentair at ethics@pentair.com responsibility. Therefore, on E and F terms, plus CFR and CPT, the buyer
or to such other location as Pentair may designate. shall provide full cargo insurance coverage, and on D terms, plus CIF and
(l) Prohibited Trade. Buyer will not sell, re-export or transfer any CIP, the seller shall provide full cargo insurance coverage.
products or technical information or services supplied under this For destinations and/or cargo on which governmental or insurance restrictions
Agreement to any other countries except in full compliance with require additional approvals and/or premiums, or a split in coverage other
all applicable governmental requirements, including but not limited than house-to-house, the responsible party/parties shall take such additional
to applicable economic sanctions and constraints administered by measures to ensure that the shipment is appropriately covered.
the U.S. Treasury Department and applicable export control U.S. Export Controls: If intended for export, all goods and technology are
measures administered by the U.S. Department of Commerce and exported in accordance with the Export Administration Regulations of the
U.S. Department of State, any other U.S. government agencies, United States. Diversion contrary to U.S. law is prohibited.
and measures administered by the European Union or the
government agencies of any other countries. Without limiting the I have read, understand, and fully agree to the terms and conditions as
foregoing, Buyer will not sell, re-export or transfer any products or presented for all products purchased from Pentair Flow Technologies,
technical information or services supplied by Pentair to Iran, North LLC and Pentair Filtration Solutions LLC.
Korea, Syria, Cuba and North Sudan, including any entities or
persons in those countries, either directly or indirectly. Any
violation of the above shall be deemed a material breach of this Authorized Signature:________________________________________
Agreement and sufficient basis for Pentair to reject any or all
orders or to terminate this Agreement. Compliance with the above Printed Name: ______________________________________________
is a prerequisite for performance under this Agreement, and if
there is a failure to comply with same, the parties agree that they Company:__________________________________________________
are incapable of meeting the obligations under this Agreement.
Pentair reserves the right to refuse to enter into or perform any Company Mailing Address:____________________________________
order, and to cancel any order, if Pentair in its sole discretion
determines that such order could violate any applicable law or __________________________________________________________
regulation of the United States, or any other governments. The
parties agree that any such refusal or cancellation of any order, or Date:______________________________________________________

Pentair Flow and Filtration Solutions Terms of Sale 06/2016 KC-585 06/2016
Page 31 of 31

You might also like