IEC 60529
Degrees of Protection Provided by Enclosures = Ingress of Water
th
Date of issue...........................................: September 18 , 2009
Testing Laboratory ...............................: TUV Rheinland of North America, Inc
Address...................................................: 12 Commerce Road, Newtown, CT 06470, U.S.A.
Testing location / address .......................: 1819 Aston Avenue, Suite 103, Carlsbad, CA 92008, U.S.A.
Applicant’s name ..................................: SouthWest Windpower
Address...................................................: 1801 West Route 66, Flagstaff, AZ 86001
Test specification:
Standard .................................................: IEC 60529: 1989-11 + A1:1999
EN 60529 :1991-10 (incl. Corrigendum: 1993-05 ) + A1: 2000-02
Test procedure........................................: --
Non-standard test method…………..: N/A
Test Report Form No. ...........................: IEC60529
TRF Originator ........................................: TUV Rheinland of North America, Inc.
Master TRF.............................................: Dated 2008-02
IEC60529
IEC60529
Summary of testing:
The Skystream 3.7 turbine (without the blades) was tested according to IEC60529, category ‘IPX6’. The
purpose of testing was to verify the conformance of the sample to the before mentioned category. In
addition a hipot (dielectric strength-) requested by the customer was performed prior and after the rain test
between the electrical connection (Line / Neutral) and metal enclosure of the turbine.
The test sample was mounted on a pole as shown in the photographs at the end of this report. The IPX6
test apparatus was adjusted as per clause 14.2.6 of IEC 60529 and the surfaces were sprayed from all
practicable directions for a total testing time of 4 min. The sample then was checked for dielectric strength
between the electrical connection and enclosure of the turbine (PE-GND connection) for one minute with
passing results
After the dielectric strength test the sample was opened for inspection and no water intrusion was noted.
IEC60529
IEC60529
Test set-up: The test sample was set-up outside the building of TUV Rheinland of North America,
Carlsbad Office, on a parking lot (leveled); the test was performed with TUV
Rheinland’s Rain Tester using the equipment for category IPX6-testing
(2 bins filled with water [total: 200l ], water pump [gas driven], nozzle [12.5 mm dia]
with flow meter);
The testing was performed in two sessions (2 x 200l for 2 min each session). After the
first session the two water bins were refilled and the testing arrangement was adjusted
to better cover the three remaining sides of the sample. The time between the first and
the second session was approx. 10 min.
The water jet hose nozzle was hold in a distance of 2.5 to 3.0m during the test, all
sides of the test samples were tested for a total time of 4 min. (2 sessions of 2 min.
each), adjusting the water flow rate to 100l +/- 5%.
The reading on the flow meter was verified before the testing by filling a 5 Gallon
bucket (18.9l) within 10.8 – 11.9 seconds.
(For Photographs of test set-up / testing refer to last page)
Result: After the rain test a Hipot test (1.000Vac for basic insulation) was performed.
Then the test sample was carefully opened. No evidence of water / water drops was
found on the gasket of the hatchcover and inside the unit. The inside of the turbine with
all electrical components was carefully checked.
*) For IPX6-testing the gas driven pump was adjusted to show a water flow of approx. 95 to 100 l/min. A
5Gal-bucket (18.75l) was filled with water and the time was measured to be within 10.8 and 11.9s. The test
was repeated 5 times to get an average. This procedure confirms the flowrate of ~100l/min.
**) The hipot test voltage and leakage current during the testing was verified with two digital multimeters for better and
more accurate readings:
Hipot test prior rain test for Hipot test after rain test
verification purpose [5sec]
Hipot voltage at input wiring of 1.025Vac 1.025Vac [60sec]
turbine
Leakage current for ‘passing’ 28mA 28mA
condition
IEC60529
The degree of protection provided by an enclosure is indicated by the IP Code in the following way:
IEC60529
IEC60529
IEC60529
Rain Test
IEC60529
IEC60529
Originally some tape was used to hold the turbine in place but
later was replaced by bungee straps attached to a pallet
IEC60529
IEC60529
Readings show 1030Vac / 28.3mA at the beginning of the 1min. hipot test
IEC60529
IEC60529
IEC60529
IEC60529
IEC60529
IEC60529
IEC60529