4、 真因描述 Describe the root cause Miêu tả nguyên nhân cốt lõi 日期 Date ngày
4.1 8 月 16 日收到客户寄回 3pcs 产品,对产品进行外观确认,具体如下: 2023/8/18
On August 16th, we received 3pcs of products from the customer and checked their appearance. The
details are as follows:
No: 1008960562 No: 10388880355 No: 1038368431
线身有无使用痕迹
PIN 针
编号 Check if Is there any use mark
PIN
on the cable
线身发黄,明显使用痕迹 无异常
1008960562 The cable body turns yellow Normal, No
with obvious usage marks damage
无异常
1038888035 无明显使用痕迹 Normal, No
No obvious signs of use damage
无异常
轻微污渍 Normal, No
1038368431 Mild stains
damage
1008960562
可正常充电
4.4.2 查看大脚开裂现象,焊点焊锡饱满,开裂是焊接后受外力影响导致。
Check the phenomenon of large foot cracking, the solder joint is full, and the cracking is caused by
external force after welding
生产过程中,只有功能第一次测试对插时,才有可能导致大脚 PIN 焊点位置受力。实际模拟测
试大脚 PIN 可承受的最大力为 18.241N,当第一次测试插头倾斜插入时,大脚 PIN 位置受力超
过 18.241 就会导致大脚 PIN 焊点开裂。
During the production process, only when the function is tested for the first time is it possible to cause
stress on the position of the large pin solder joint. The maximum force that the actual simulation test
pin can withstand is 18.241N. When the plug is tilted and inserted for the first time, if the force on the
pin position exceeds 18.241, it will cause the pin solder joint to crack.
4.5.4 取产品测试功能和压降都是 OK 的.
4.5.4 The product testing function and voltage drop are all OK
VBUS 压降 OK GND 压降 OK
VBUS 压降 OK GND 压降 OK
可充电,可传输数
可充电,可传输数 据
据